Federal Aviation Administration September 25, 2015 – Federal Register Recent Federal Regulation Documents
Results 1 - 8 of 8
Federal Contract Tower Safety Action Program (SAFER-FCT) and Air Traffic Safety Action Program for Engineers & Architects, Staff Support Specialists, Aviation Technical System Specialists (Series 2186) and Flight Procedures Team (ATSAP-X)
This action affirms the order published in the Federal Register on April 3, 2015, regarding the application of Title 14, Code of Federal Regulations (14 CFR) Part 193, Federal Contract Tower SAFER- FCT Program and the Air Traffic Organization Engineers and Architects, Staff Support Specialist (Series 2186) and Flight Procedures Team (hereinafter ``Region X'') ATSAP-X Program. The Notice proposed that safety information provided to the FAA under the SAFER-FCT and ATSAP-X programs be designated by an FAA Order as protected from public disclosure in accordance with the provisions of 14 CFR part 193, Protection of Voluntarily Submitted Information. The designation is intended to encourage persons to voluntarily provide information to the FAA under the SAFER-FCT and ATSAP-X, so the FAA can learn about and address aviation safety hazards and implement, as appropriate corrective measures for events or safety issues.
Airworthiness Directives; The Boeing Company Airplanes
We are revising an earlier proposed airworthiness directive (AD) for The Boeing Company Model 777-200 and -300 series airplanes, equipped with Rolls-Royce Model RB211-Trent 800 engines. The notice of proposed rulemaking (NPRM) proposed to require repetitive inspections of the thrust reverser (T/R) structure and sealant, and related investigative and corrective actions if necessary. The NPRM was prompted by reports of T/R events related to thermal damage of the T/R inner wall. This action revises the NPRM by proposing to add different repetitive inspections requirements for T/R halves with a thermal protective system installed. This action also revises the NPRM by proposing to require installation of serviceable T/R halves, which would terminate the repetitive inspections in this SNPRM. This SNPRM also proposes to revise the inspection or maintenance program by incorporating new airworthiness limitations. We are proposing this SNPRM to detect and correct a degraded T/R inner wall panel, which could lead to failure of the T/R and adjacent components and their consequent separation from the airplane, and which could result in a rejected takeoff (RTO) and cause asymmetric thrust and consequent loss of control of the airplane during reverse thrust operation. If a T/R inner wall overheats, separated components could cause structural damage to the airplane, damage to other airplanes, or possible injury to people on the ground. Since these actions impose an additional burden over that proposed in the NPRM, we are reopening the comment period to allow the public the chance to comment on these proposed changes.
Airworthiness Directives Airbus Helicopters (Previously Eurocopter France)
We propose to supersede airworthiness directive (AD) 2014-12- 51 for Airbus Helicopters (previously Eurocopter France) Model EC130B4 and EC130T2 helicopters. AD 2014-12-51 currently requires repetitively inspecting the tailboom to Fenestron junction frame (junction frame) for a crack. This proposed AD would retain the requirements of AD 2014- 12-51, change the applicability from helicopters with certain hours time-in-service (TIS) to junction frames with certain hours TIS, and add a compliance time for sling cycles to the junction frame inspection interval. These proposed actions are intended to detect a crack and to prevent failure of the junction frame, which could result in loss of the Fenestron and subsequent loss of control of the helicopter.
Proposed Establishment of Class E Airspace; International Falls, MN
This action makes a correction to the NPRM published in the Federal Register of August 27, 2015, proposing to establish Class E en route domestic airspace in the International Falls, MN area. Exclusionary reference to Canadian airspace was omitted from the regulatory text.
Establishment of Class E Airspace; Poplarville-Pearl River County Airport, MS
This action establishes Class E Airspace at Poplarville, MS. to accommodate new Area Navigation (RNAV) Global Positioning System (GPS) Standard Instrument Approach Procedures (SIAPs) serving Poplarville-Pearl River County Airport. Controlled airspace is necessary for the safety and management of instrument flight rules (IFR) operations at the airport. The FAA found that Class E airspace already exists for another airport in Poplarville, MS, and, therefore, is changing the title and airspace designation in this final rule to include the airport name. Also, a minor adjustment is made to the geographic coordinates of the airport.
Amendment of Class E Airspace; Mackall AAF, NC
This action amends Class E Airspace at Mackall Army Airfield (AAF), NC, bringing current the regulatory text under the airspace designation for Mackall AAF, NC, by replacing the acronym ``NCB'' with ``NDB''. This is an administrative change to coincide with the FAA's aeronautical database.
Airworthiness Directives; Alpha Aviation Concept Limited Airplanes
We propose to adopt a new airworthiness directive (AD) for certain Alpha Aviation Concept Limited Model R2160 airplanes that would supersede AD 2008-09-01. This proposed AD results from mandatory continuing airworthiness information (MCAI) originated by an aviation authority of another country to identify and correct an unsafe condition on an aviation product. The MCAI describes the unsafe condition as a need to revise the maintenance program to include the revised airworthiness limitations for the internal wing structure and wing attachment inspections. We are issuing this proposed AD to require actions to address the unsafe condition on these products.
Airworthiness Directives; Sikorsky Aircraft Corporation (Sikorsky) Helicopters
We propose to supersede airworthiness directive (AD) 2014-07- 04R1 for certain Sikorsky Model S-92A helicopters. AD 2014-07-04R1 currently requires repetitive inspections in the upper deck area for incorrectly installed clamps and chafing between the electrical wires and the hydraulic lines and replacing any unairworthy wires or hydraulic lines. Since we issued AD 2014-07-04R1, the manufacturer has developed an alteration that corrects the unsafe condition described in AD 2014-07-04R1. This proposed AD would require altering the wiring system in the upper deck area. These proposed actions are intended to prevent a fire in an area of the helicopter without extinguishing capability and subsequent loss of control of the helicopter.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.