A well casing for a well constructed by excavation shall:

(a) Extend above the ground surface a minimum of 18 inches or, in areas prone to flooding, to a greater height sufficient to prevent the entrance of surface water into the well;

(b) Have a secure cover with a seal to prevent the entrance of insects or other foreign matter into the well. Wooden covers shall not be used;

(c) Have joints sealed to exclude surface water from entering the well, if the joints are within 6 feet of the ground surface;

(d) Be set on a bed of clean crushed stone or naturally occurring coarse gravel, if present;

(e) Have crushed stone placed around the exterior casing at the bottom section(s) to promote infiltration of water and provide additional storage, if appropriate for the soil conditions at the site; and

(f) Be properly aligned.

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.