Additional Ambient Aerosol CNC Quantitative Fit Testing Protocols: Respiratory Protection Standard, 50739-50756 [2019-20686]
Download as PDF
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
for the registrant. The standard to use
when determining whether disclosure
would cause competitive harm for the
registrant is the same standard that
would apply when a registrant requests
confidential treatment of confidential
trade secrets or confidential commercial
or financial information pursuant to
Securities Act Rule 406 (17 CFR
230.406) and Exchange Act Rule 24b–2
(17 CFR 240.24b–2), each of which
incorporates the criteria for nondisclosure when relying upon
Exemption 4 of the Freedom of
Information Act (5 U.S.C. 552(b)(4)). A
registrant is not required to seek
confidential treatment under the
procedures in Securities Act Rule 406
and Exchange Act Rule 24b–2 if it
determines that the disclosure would
cause competitive harm in reliance on
this instruction; however, in that case,
the registrant must discuss how difficult
it will be for the executive or how likely
it will be for the registrant to achieve the
undisclosed target levels or other
factors.
*
*
*
*
*
PART 230—GENERAL RULES AND
REGULATIONS, SECURITIES ACT OF
1933
11. In part 230:
a. The general authority citation for
part 230 continues to read as set forth
below; and
■ b. The specific authority citation for
§§ 230.400 to 230.499 is revised; and
■ c. A specific authority citation for
§ 230.457 is added.
The authorities read as follows:
■
■
Authority: 15 U.S.C. 77b, 77b note, 77c,
77d, 77f, 77g, 77h, 77j, 77r, 77s, 77z–3, 77sss,
78c, 78d, 78j, 78l, 78m, 78n, 78o, 78o–7 note,
78t, 78w, 78ll(d), 78mm, 80a–8, 80a–24, 80a–
28, 80a–29, 80a–30, and 80a–37, and Pub. L.
112–106, sec. 201(a), sec. 401, 126 Stat. 313
(2012), unless otherwise noted.
*
*
*
*
*
Sections 230.400 to 230.499 issued under
secs. 6, 8, 10, 19, 48 Stat. 78, 79, 81, and 85,
as amended (15 U.S.C. 77f, 77h, 77j, 77s).
Sec. 230.457 also issued under secs. 6 and
7, 15 U.S.C. 77f and 77g.
*
*
*
*
*
Regulation C—Registration
12. The authority citation under the
undesignated center heading
‘‘Regulation C—Registration’’ is
removed.
■ 13. Amend § 230.406 by:
■ a. Removing preliminary notes (1) and
(2);
■ b. Adding introductory text; and
■ c. Revising paragraph (b)(2)(ii).
The addition and revision read as
follows:
khammond on DSKJM1Z7X2PROD with RULES
■
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
§ 230.406 Confidential treatment of
information filed with the Commission.
Confidential treatment of
supplemental information or other
information not required to be filed
under the Act should be requested
under 17 CFR 200.83 and not under this
rule. All confidential treatment requests
shall be submitted in paper format only,
whether or not the filer is an electronic
filer. See Rule 101(c)(1)(i) of Regulation
S–T (§ 232.101(c)(1)(i) of this chapter).
*
*
*
*
*
(b) * * *
(2) * * *
(ii) A statement of the grounds of the
objection referring to and analyzing the
applicable exemption(s) from disclosure
under the Freedom of Information Act
(5 U.S.C. 552) and a justification of the
period of time for which confidential
treatment is sought;
*
*
*
*
*
PART 240—GENERAL RULES AND
REGULATIONS, SECURITIES ACT OF
1934
14. The general authority citation for
part 240 continues to read as follows:
■
Authority: 15 U.S.C. 77c, 77d, 77g, 77j,
77s, 77z–2, 77z–3, 77eee, 77ggg, 77nnn,
77sss, 77ttt, 78c, 78c–3, 78c–5, 78d, 78e, 78f,
78g, 78i, 78j, 78j–1, 78k, 78k–1, 78l, 78m,
78n, 78n–1, 78o, 78o–4, 78o–10, 78p, 78q,
78q–1, 78s, 78u–5, 78w, 78x, 78ll, 78mm,
80a–20, 80a–23, 80a–29, 80a-–37, 80b–3,
80b–4, 80b–11, 7201 et seq.; and 8302; 7
U.S.C. 2(c)(2)(E); 12 U.S.C. 5221(e)(3); 18
U.S.C. 1350; and Pub. L. 111–203, 939A, 124
Stat. 1887 (2010); and secs. 503 and 602, Pub.
L. 112–106, 126 Stat. 326 (2012), unless
otherwise noted.
*
*
*
*
*
affect in any way, the obligation of any
issuer or any independent accountant to
make all public disclosures required by
law, by any Commission disclosure
item, rule, report, or form, or by any
applicable accounting, auditing, or
professional standard.
*
*
*
*
*
■ 16. Amend § 240.24b–2 by revising
paragraph (b)(2) to read as follows:
§ 240.24b–2 Nondisclosure of information
filed with the Commission and with any
exchange.
*
*
*
*
*
(b) * * *
(2) An application making objection
to the disclosure of the confidential
portion. Such application shall be on a
sheet or sheets separate from the
confidential portion, and shall contain:
(i) An identification of the portion;
(ii) A statement of the grounds of
objection referring to, and containing an
analysis of, the applicable exemption(s)
from disclosure under the Freedom of
Information Act (5 U.S.C. 552(b)), and a
justification of the period of time for
which confidential treatment is sought;
(iii) A written consent to the
furnishing of the confidential portion to
other government agencies, offices or
bodies and to the Congress; and
(iv) The name of each exchange, if
any, with which the material is filed.
*
*
*
*
*
By the Commission.
Dated: September 17, 2019.
Vanessa Countryman,
Secretary.
[FR Doc. 2019–20369 Filed 9–25–19; 8:45 am]
BILLING CODE 8011–01–P
Subpart A—Rules and Regulations
Under the Securities Exchange Act of
1934
15. Amend § 240.10A–1 by revising
paragraph (c) introductory text to read
as follows:
■
DEPARTMENT OF LABOR
Occupational Safety and Health
Administration
29 CFR Part 1910
§ 240.10A–1 Notice to the Commission
Pursuant to Section 10A of the Act.
[Docket No. OSHA–2015–0015]
*
RIN 1218–AC94
*
*
*
*
(c) A notice or report submitted to the
Office of the Chief Accountant in
accordance with paragraphs (a) and (b)
of this section shall be deemed to be an
investigative record and shall be
nonpublic and exempt from disclosure
pursuant to the Freedom of Information
Act to the same extent and for the same
periods of time that the Commission’s
investigative records are nonpublic and
exempt from disclosure under, among
other applicable provisions, 5 U.S.C.
552(b)(7). Nothing in this paragraph,
however, shall relieve, limit, delay, or
PO 00000
Frm 00029
Fmt 4700
Sfmt 4700
50739
Additional Ambient Aerosol CNC
Quantitative Fit Testing Protocols:
Respiratory Protection Standard
Occupational Safety and Health
Administration (OSHA), Department of
Labor.
ACTION: Final rule.
AGENCY:
OSHA is approving two
additional quantitative fit testing
protocols for inclusion in appendix A of
the Respiratory Protection Standard.
These protocols are: The modified
SUMMARY:
E:\FR\FM\26SER1.SGM
26SER1
50740
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
ambient aerosol condensation nuclei
counter (CNC) quantitative fit testing
protocol for full-facepiece and half-mask
elastomeric respirators and the modified
ambient aerosol CNC quantitative fit
testing protocol for filtering facepiece
respirators. The protocols apply to
employers in general industry, shipyard
employment, and the construction
industry. Both protocols are abbreviated
variations of the original OSHAapproved ambient aerosol CNC
quantitative fit testing protocol (often
referred to as the PortaCount® protocol),
but differ from the test by the exercise
sets, exercise duration, and sampling
sequence. These protocols will serve as
alternatives to the four existing
quantitative fit testing protocols already
listed in appendix A of the Respiratory
Protection Standard and will maintain
safety and health protections for
workers while providing additional
flexibility and reducing compliance
burdens.
The final rule becomes effective
on September 26, 2019.
ADDRESSES: In accordance with 28
U.S.C. 2112(a), the agency designates
Edmund Baird, Acting Associate
Solicitor of Labor for Occupational
Safety and Health, Office of the Solicitor
of Labor, Room S–4004, U.S.
Department of Labor, 200 Constitution
Avenue NW, Washington, DC 20210, to
receive petitions for review of the final
rule.
FOR FURTHER INFORMATION CONTACT:
General information and press inquiries:
Frank Meilinger, Director, Office of
Communications; telephone: (202) 693–
1999; email: meilinger.francis2@dol.gov.
Technical inquiries: Natalia Stakhiv,
Directorate of Standards and Guidance;
telephone: (202) 693–2272; email:
stakhiv.natalia@dol.gov.
SUPPLEMENTARY INFORMATION:
DATES:
Table of Contents
khammond on DSKJM1Z7X2PROD with RULES
I. Background
II. Summary and Explanation of the Final
Rule
III. Procedural Determinations
I. Background
Appendix A of OSHA’s Respiratory
Protection Standard (29 CFR 1910.134)
currently contains four quantitative fit
testing protocols: Generated aerosol;
ambient aerosol condensation nuclei
counter (CNC); controlled negative
pressure (CNP); and controlled negative
pressure REDON. TSI Incorporated
(‘‘TSI’’) proposed the ambient aerosol
CNC protocol—often called the
PortaCount® protocol after the CNC
instrument manufactured by TSI—in
1987. OSHA allowed the ambient
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
aerosol CNC protocol for fit testing
under a compliance interpretation
published in 1988. OSHA eventually
incorporated that protocol into
appendix A of the Respiratory
Protection Standard when it revised the
standard in 1998.
In 2006, TSI submitted two additional
quantitative fit testing protocols to
OSHA for approval and inclusion in
appendix A of the Respiratory
Protection Standard. These protocols
were modified, abbreviated versions of
the original ambient aerosol CNC
protocol already approved by OSHA
and listed in appendix A. OSHA
published a notice of proposed
rulemaking (NPRM) on January 21, 2009
(74 FR 3526) to include the two
protocols in its Respiratory Protection
Standard, but later concluded that they
were not sufficiently accurate or
reliable. OSHA withdrew the proposed
rule without prejudice on January 27,
2010 (75 FR 4323), and invited the
developers to resubmit the two
protocols after addressing the issues of
concern listed in the withdrawal
notification. In 2014, TSI submitted
three new quantitative fit testing
protocols for OSHA approval. These
three protocols also were modified,
abbreviated versions of the original
ambient aerosol CNC protocol, but
different from the two protocols TSI
submitted to OSHA in 2006.
Part II of appendix A of OSHA’s
Respiratory Protection Standard
specifies the procedure for adding new
fit testing protocols to the standard.
Under that procedure, if OSHA receives
an application for a new fit testing
protocol meeting certain criteria, it must
commence a rulemaking proceeding to
consider adopting the proposed
protocol. These criteria are: (1) A test
report prepared by an independent
government research laboratory (e.g.,
Lawrence Livermore National
Laboratory, Los Alamos National
Laboratory, the National Institute for
Standards and Technology) stating that
the laboratory tested the protocol and
found it to be accurate and reliable; or
(2) an article published in a peerreviewed industrial hygiene journal
describing the protocol and explaining
how the test data support the protocol’s
accuracy and reliability. TSI’s 2014
application for approval of three new
quantitative fit testing protocols met the
second criterion. OSHA considers such
proposals under the notice-andcomment rulemaking procedures
specified in Section 6(b)(7) of the
Occupational Safety and Health Act of
1970 (the ‘‘Act’’) (29 U.S.C. 655(b)(7)).
PO 00000
Frm 00030
Fmt 4700
Sfmt 4700
II. Summary and Explanation of the
Final Rule
A. Proposed Rulemaking
In July 2014, TSI submitted an
application requesting that OSHA
approve three new quantitative fit
testing protocols for inclusion in
appendix A of OSHA’s Respiratory
Protection Standard (OSHA–2015–
0015–0003). These three protocols were
modified, abbreviated versions of the
original ambient aerosol CNC protocol
approved by OSHA and listed in
appendix A, but different from the ones
submitted to OSHA by TSI in 2006.
TSI’s application included three peerreviewed articles (‘‘the Richardson
studies’’) describing the accuracy and
reliability of TSI’s proposed protocols.1
The application letter also included a
copy of the 2010 ANSI/AIHA (American
National Standards Institute/American
Industrial Hygiene Association) Z88.10
‘‘Respirator Fit Testing Methods’’
standard (‘‘the ANSI standard’’), which
contains ‘‘Annex A2: Criteria for
Evaluating New Fit Test Methods’’ (‘‘the
ANSI annex’’) (OSHA–2015–0015–
0007). TSI also submitted two white
papers: One describing TSI’s analysis of
its talking exercise data and the second
describing TSI’s process and rationale
behind the fit test exercises that were
employed in the Richardson studies
(OSHA–2015–0015–0001, OSHA–2015–
0015–0008). OSHA determined that the
information submitted in TSI’s
application met the criteria required for
initiating a rulemaking to determine
whether OSHA should approve the new
protocols and add them to appendix A
of the Respiratory Protection Standard.
OSHA issued a notice of proposed
rulemaking (NPRM) on October 7, 2016,
proposing to add the new protocols and
inviting public comments.
The three new protocols submitted by
TSI in July 2014 included one for fullfacepiece elastomeric respirators (the
Fast-Full method), one for half-mask
elastomeric respirators (the Fast-Half
method), and one for filtering facepiece
respirators (FFRs) (the Fast-FFR
method). The authors of the Richardson
1 Richardson, A.W. et al. (2014a), ‘‘Evaluation of
a Faster Fit Testing Method for Elastomeric HalfMask Respirators Based on the TSI PortaCount,’’
Journal of the International Society for Respiratory
Protection 31(1): 9–22 (OSHA–2015–0015–0004);
Richardson, A.W. et al. (2013), ‘‘Evaluation of a
Faster Fit Testing Method for Full-Facepiece
Respirators Based on the TSI PortaCount,’’ Journal
of the International Society for Respiratory
Protection 30(2): 116–128 (OSHA–2015–0015–
0005); Richardson, A.W. et al. (2014b), ‘‘Evaluation
of a Faster Fit Testing Method for Filtering
Facepiece Respirators Based on the TSI
PortaCount,’’ Journal of the International Society for
Respiratory Protection 31(1): 43–56 (OSHA–2015–
0015–0006).
E:\FR\FM\26SER1.SGM
26SER1
khammond on DSKJM1Z7X2PROD with RULES
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
studies evaluated each of the three types
of respirators for method performance
separately, but the protocols for the
Fast-Full and Fast-Half methods were
identical. As such, and to prevent
duplicative regulatory text, OSHA
proposed to consolidate the Fast-Full
and Fast-Half methods into a single
protocol for approval: The modified
ambient aerosol condensation nuclei
counter (CNC) quantitative fit testing
protocol for full-facepiece and half-mask
elastomeric respirators. OSHA further
proposed to approve the Fast-FFR
protocol as the modified ambient
aerosol condensation nuclei counter
(CNC) quantitative fit testing protocol
for filtering facepiece respirators. No
commenters objected to the
consolidation and naming of the
protocols during the public comment
period.
The original ambient aerosol CNC
protocol consists of eight test exercises,
performed in the following order:
Normal breathing, deep breathing,
turning head side-to-side, moving head
up-and-down, talking, grimace, bending
over, and normal breathing again. The
modified ambient aerosol CNC protocol
for full-facepiece and half-mask
elastomeric respirators differs as
follows: (1) It includes only three of the
eight original test exercises (bending
over, head side-to-side, and head upand-down); (2) it adds jogging-in-place
as a new exercise; and (3) it reduces the
total test duration from 7.2 to 2.5
minutes. The modified ambient aerosol
CNC protocol for FFRs differs from the
original ambient aerosol CNC protocol
as follows: (1) It includes only four of
the eight original test exercises (bending
over, talking, head side-to-side, and
head up-and-down) and (2) it reduces
the total test duration from 7.2 to 2.5
minutes.
The three Richardson studies (OSHA–
2015–0015–0004, OSHA–2015–0015–
0005, OSHA–2015–0015–0006)
compared the fit factors for the new
protocols to a reference method based
on the approach specified in the ANSI
annex.2 This approach requires the
performance evaluation study to
administer sequential paired tests using
the proposed fit testing method and
reference method during the same
respirator donning. The reference
method consisted of the standard OSHA
exercises listed in Section I.A.14 of
appendix A of the Respiratory
Protection Standard (which are also the
eight test exercises used for the original
2 A fit factor is a quantitative estimate of the fit
of a particular respirator to a specific individual,
and typically estimates the ratio of the
concentration of a substance in ambient air to its
concentration inside the respirator when worn.
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
ambient aerosol CNC protocol), minus
the grimace exercise, in the same order
as described in the standard (i.e., normal
breathing, deep breathing, head side-toside, head up-and-down, talking,
bending over, normal breathing). Each
exercise was performed for 60 seconds.
These protocols will serve as
alternatives to the four existing
quantitative fit testing protocols already
listed in appendix A of the Respiratory
Protection Standard and will maintain
safety and health protections for
workers while providing additional
flexibility and reducing compliance
burdens. This rule is a deregulatory
action under Executive Order 13771 (82
FR 9339 (January 30, 2017)). It has
annualized net cost savings estimated at
$4.1 million. A detailed discussion of
OSHA’s estimates of the rule’s benefits,
costs, and cost savings is included in
the Final Economic Analysis and
Regulatory Flexibility Certification
section.
B. Articles Supporting New Fit Testing
Protocols
TSI supported its application for
adding the new protocols with the three
Richardson studies that indicate
respectively that the proposed Fast-Half,
Fast-Full, and Fast-FFR methods can
identify poorly fitting respirators as well
as the reference method used. Each
article described a study that compared
fit test results using a reference method
specified in the ANSI annex with results
using one of the proposed methods. The
following subsections detail the
methodologies and findings of the three
Richardson studies.
1. Evaluation of the Fast-Half Method
a. Study Methods
The first Richardson study evaluated
the Fast-Half method.3 The study
authors selected three models of
NIOSH-approved, half-mask airpurifying respirators—each available in
three sizes—from ‘‘leading U.S. mask
manufacturers’’ equipped with P100
filters.4 Respirators were probed with a
flush sampling probe located between
the nose and mouth. The study included
9 female and 16 male participants.
Each test subject donned a respirator
for a five-minute comfort assessment
3 Richardson, A.W. et al. (2014a), ‘‘Evaluation of
a Faster Fit Testing Method for Elastomeric HalfMask Respirators Based on the TSI PortaCount,’’
Journal of the International Society for Respiratory
Protection 31(1): 9–22 (OSHA–2015–0015–0004).
4 The authors chose not to identify the specific
respirator models ‘‘because the intentional missizing and lack of performing a user seal check
would misrepresent performance of these
respirators when used as part of a proper
respiratory protection program’’ (OSHA–2015–
0015–0004).
PO 00000
Frm 00031
Fmt 4700
Sfmt 4700
50741
and then performed two sets of fit test
exercises, one using the reference
method and another the Fast-Half
method. The study authors randomized
the order of the two sets of fit test
exercises for each test subject. The
reference method consisted of the eight
standard OSHA exercises listed in
Section I.A.14 of appendix A of the
Respiratory Protection Standard, minus
the grimace exercise, in the same order
as required in the standard (i.e., normal
breathing, deep breathing, head side-toside, head up-and-down, talking,
bending over, normal breathing). The
study subject performed each exercise
for 60 seconds.
The study authors explained that they
decided to exclude the grimace exercise
because it ‘‘is intended to break the
respirator seal to the face’’ which
‘‘potentially results in a shift of the
respirator’’ (OSHA–2015–0015–0004).
TSI submitted an additional explanation
as to why the grimace exercise was
excluded in all three Richardson studies
(OSHA–2015–0015–0008). According to
TSI, ‘‘[l]ittle or no support was found for
the grimace exercise among respirator fit
test experts,’’ and ‘‘[t]he most common
fault expressed by a number of
experienced fit testers and industry
experts was that the grimace cannot be
consistently applied or even defined’’
(Id.). TSI further explained that the
grimace exercise is intended to break
the face seal, which may not reseal in
the same way for subsequent exercises.
As a result, the shift in the respirator
caused by grimacing can potentially
confound comparisons between the fit
test methods. TSI finally noted that the
fit factor from the grimace exercise (if
measured) is not used to calculate the
overall fit factor result under the
original ambient aerosol CNC method.
The Fast-Half method included four
exercises: Bending, jogging-in-place,
head side-to-side, and head up-anddown. Each test subject took two breaths
at each extreme of the head side-to-side
and head up-and-down exercises and at
the bottom of the bend in the bending
exercise.
Although not discussed in the
Richardson study, TSI explained its
rationale for selecting the exercises that
were later utilized in the three
Richardson studies. The exercises were
identified, by TSI, as being the most
rigorous for (i.e., the best at) identifying
poor fitting respirators in two white
papers TSI prepared and submitted to
OSHA (OSHA–2015–0015–0001,
OSHA–2015–0015–0008). TSI reached
its conclusions and selected the
exercises based on a literature review,
informal conversations with industry fit
test experts, and in-house pilot studies.
E:\FR\FM\26SER1.SGM
26SER1
khammond on DSKJM1Z7X2PROD with RULES
50742
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
‘‘Talking out loud,’’ ‘‘bending,’’ and
‘‘moving head up/down’’ were
determined to be the three most critical
exercises in determining the overall fit
factor for abbreviated respirator fit test
methods by Zhuang et al. (OSHA–2015–
0015–0011).5 TSI’s in-house pilot fit
testing studies supported the
conclusions made by Zhuang et al.,
however, additional analysis of the TSI
data by TSI uncovered an unexpected
trend within the data for the talking
exercise (OSHA–2015–0015–0001,
OSHA–2015–0015–0008). TSI collected
fit test data on subjects using
consecutive sets of the seven-exercise
reference method described above. TSI
analyzed the frequency with which each
exercise produced the lowest fit factor.
Fit test data were separated into three
groups: All fit tests, good-fitting fit tests,
and poor-fitting fit tests. A poor-fitting
fit test was defined as any test where at
least one exercise failed, and a goodfitting fit test was defined as one where
no exercises failed.6 TSI’s results
showed that normal breathing, deep
breathing, and talking rarely produced
the lowest fit factor (frequency ≤3
percent) for poor-fitting full-facepiece
respirators. On this basis, these three
less rigorous exercises were eliminated
by TSI for both the Fast-Full and FastHalf methods. The bending exercise was
the most rigorous exercise for poorfitting full-facepiece and half-mask
elastomeric respirators. Talking was the
exercise among the seven exercises that
most often had the lowest fit factor for
good-fitting full-facepiece and half-mask
respirators in the TSI pilot study. None
of the other exercises stood out for halfmask respirators, but TSI reasoned that
there was a lack of data suggesting that
half-mask respirator fit tests should use
different exercises than full-facepiece
respirators (OSHA–2015–0015–0008).
TSI added jogging-in-place for a fourth
rigorous test exercise as part of the
protocol that the Richardson authors
would evaluate, reasoning that jogging
‘‘leverages the weight of the facepiece,
much like bending, but on a different
axis, and also because both OSHA and
ANSI currently include jogging as an
alternative exercise’’ (OSHA–2015–
0015–0008). Jogging-in-place is an
alternate (i.e., elective as opposed to
required) exercise in the ANSI annex.
The study authors stated that jogging is
‘‘aggressive in terms of evaluating the
5 Zhuang et al. (2004) considered those exercises
that had the lowest fit factors as the most critical
in determining the overall fit factor.
6 Pass/fail levels were 500 for full-facepiece
respirators and 100 for half-mask elastomeric
respirators and FFRs.
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
respirator seal’’ (OSHA–2015–0015–
0004).
The study authors conducted the
experiments in a large chamber and
added sodium chloride (NaCl) aerosol to
augment particle concentrations, which
they expected to range between 5,000
and 20,000 particles/cm3 (target =
10,000 p/cm3). The study authors used
a single CPC instrument, the
PortaCount® Model 8030 (TSI
Incorporated, Shoreview MN), for
sampling and valuation. They
connected the instrument to two equallength sampling tubes. The first tube
sampled particle concentrations inside
the facepiece, and the second tube
sampled the ambient particle
concentration. The authors used TSI
software to switch between sampling
lines and to record concentration data.
During the reference method, for each
exercise, the ambient sampling tube was
first purged for four seconds before an
ambient sample was taken for 5
seconds, followed by an 11-second
purge of the in-facepiece sampling tube
and a 40-second in-facepiece sample.
The reference method took a total of 429
seconds (7 minutes 9 seconds) to
complete.
For the reference method, the authors
calculated a fit factor for each exercise
by dividing the mean ambient
concentration for that exercise by the infacepiece concentration taken during
each exercise (average of the five-second
ambient measurements before and after
the exercise). The harmonic mean of the
seven exercise fit factors equaled the
overall fit factor. During the first
exercise of the Fast-Half method
(bending over), the ambient sampling
tube was first purged for 4 seconds
before an ambient sample was taken for
five seconds; the in-facepiece sampling
tube was then purged for 11 seconds
and a sample was then taken from
inside the mask for 30 seconds. No
ambient sample was taken during the
next two exercises (jogging and head
side-to-side)—just one 30-second infacepiece sample was collected for each
exercise. For the last exercise (head upand-down), a 30-second in-facepiece
sample was taken, after which a 4second ambient purge and 5-second
ambient sample were conducted. The
Fast-Half method took a total of 149
seconds (2 minutes 29 seconds) to
complete.
For the Fast-Half method, the ambient
concentration was calculated by taking
the mean of two measurements—one
before the first exercise and one after the
last exercise. The authors calculated fit
factors for each exercise by dividing the
in-facepiece concentration taken during
that exercise by the mean ambient
PO 00000
Frm 00032
Fmt 4700
Sfmt 4700
concentration. As with the reference
method, the harmonic mean of the four
exercise fit factors represented the
overall fit factor. A minimum fit factor
of 100 is required in order to be
regarded as an acceptable fit for halfmask respirators under appendix A of
the Respiratory Protection Standard.
To ensure that respirator fit was not
significantly altered between the two
sets of exercises, a 5-second normal
breathing fit factor assessment was
included before the first exercise set,
between the two sets of exercises and at
the completion of the second exercise
set. If the ratio of the maximum to
minimum of these three fit factors was
greater than 100, this experimental trial
was excluded from data analysis.
b. Richardson Study Results
The ANSI annex specifies that an
exclusion zone within one coefficient of
variation for the reference method must
be determined. The exclusion zone is
the range of measured fit factors around
the pass/fail fit factor of 100 that cannot
be confirmed to be greater than 100 or
less than 100 with adequate confidence
and, therefore, should not be included
in evaluating performance. The study
authors determined the variability
associated with the reference method
using 48 pairs of fit factors from 16
participants. They defined the exclusion
zone as fit factor measurements within
one standard deviation of the 100 pass/
fail value. Six pairs of fit factors were
omitted by the study authors because
the normal breathing fit factor ratio
exceeded 100 and 5 pairs of fit factors
were omitted because they were
identified as outliers (> 3 standard
deviations from the mean of the
remaining data points). The exclusion
zone calculated by the study authors
ranged from 82 to 123 and did not
include the five outliers. During review
of the study methods, OSHA felt that
omitting outliers to define a variabilitybased exclusion zone deviated from the
usual scientific practice. Therefore,
OSHA recalculated the exclusion zone
with the outlier data included in the
analysis (OSHA–2015–0015–0009). The
recalculated exclusion zone was
somewhat wider, ranging from 68 to
146.
The final dataset for the ANSI FastHalf performance evaluation included
134 pairs of fit factors from 25
participants. The respirator models and
sizes were used in nearly equal
proportion. The study authors omitted
eleven pairs of fit factors because the
ratio of maximum to minimum normal
breathing fit factors was greater than
100. They also omitted one pair due to
a methodological error (sample line
E:\FR\FM\26SER1.SGM
26SER1
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
detached from respirator during test). As
such, 122 pairs were included in the
data analysis.
The study authors concluded that
their statistical analysis indicates that
the Fast-Half method met the required
acceptance criteria for test sensitivity,
predictive value of a pass, predictive
value of a fail, test specificity, and
kappa statistic 7 as defined in the ANSI
annex (see Table 1). The same was
indicated by OSHA’s statistical analysis,
utilizing the wider OSHA-recalculated
exclusion zone, which excluded an
additional three pairs for a total of nine
pairs excluded and 119 pairs included
in the analysis. OSHA therefore agrees
with the study authors that the Fast-Half
method can identify poorly fitting
respirators at least as well as the
reference method.
2. Evaluation of Fast-Full Method
a. Study Methods
The second Richardson study
evaluated the Fast-Half method.8 The
study authors selected three models of
NIOSH-approved, full-facepiece airpurifying respirators from ‘‘leading U.S.
mask manufacturers’’ equipped with
P100 filters. Each model was available
in three sizes. Respirators were probed
with a non-flush sampling probe inside
the nose cup, extending 0.6 cm into the
breathing zone. The study included 11
female and 16 male participants. The
reference method, choice of exercises,
PortaCount® instrument, test aerosol,
and sampling sequence were identical
to those used for the Fast-Half method.
Appendix A of the Respiratory
Protection Standard requires a
minimum fit factor of 500 for fullfacepiece respirators.
khammond on DSKJM1Z7X2PROD with RULES
b. Richardson Study Results
The study authors determined the
variability associated with the reference
method using 54 pairs of fit factors from
17 participants. The exclusion zone was
defined as fit factor measurements
within one standard deviation of the
500 pass/fail value. Five pairs of fit
factors were omitted because the normal
breathing fit factor ratio exceeded 100,
and three pairs of fit factors were
7 The kappa statistic is a measure of agreement
between the proposed and reference fit test
methods. It compares the observed proportion of fit
tests that are concordant with the proportion
expected if the two tests were statistically
independent. Kappa values can vary from ¥1 to +1.
Values close to +1 indicate good agreement. ANSI/
AIHA recommends kappa values >0.70.
8 Richardson, A.W. et al. (2013), ‘‘Evaluation of a
Faster Fit Testing Method for Full-Facepiece
Respirators Based on the TSI PortaCount,’’ Journal
of the International Society for Respiratory
Protection 30(2): 116–128 (OSHA–2015–0015–
0005).
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
omitted because they were identified as
outliers (≤ 3 standard deviations from
the mean of the remaining data points).
The exclusion zone calculated by the
study authors ranged from 345 to 726
and did not include the three outliers.
OSHA recalculated the exclusion zone
with the outlier data included in the
analysis (OSHA–2015–0015–0009). The
recalculated exclusion zone determined
by OSHA was somewhat wider ranging
from 321 to 780.
The final dataset for the ANSI FastFull performance evaluation included
148 pairs of fit factors from 27
participants. The respirator models and
sizes were used in nearly equal
proportion. Eleven pairs were omitted
because the ratio of maximum to
minimum normal breathing fit factors
was greater than 100; one pair was
omitted due to an observational
anomaly (a torn piece of a cleaning wipe
was observed in the respirator during
the test); 136 pairs were included in the
data analysis.
The study authors concluded that
their statistical analysis indicates that
the Fast-Full method met the required
acceptance criteria for test sensitivity,
predictive value of a pass, predictive
value of a fail, test specificity, and
kappa statistic as defined in the ANSI
annex (see Table 1). The same was
indicated by OSHA’s statistical analysis,
utilizing the wider OSHA-recalculated
exclusion zone, which excluded an
additional three pairs for a total of 15
pairs excluded and 133 pairs included
in the analysis. OSHA therefore agrees
with the study authors that the Fast-Full
method can identify poorly fitting
respirators at least as well as the
reference method.
3. Evaluation of Fast-FFR (Filtering
Facepiece Respirator) Method
a. Study Methods
The third Richardson article
evaluated the Fast-FFR method.9 Ten
models of NIOSH-approved N95 FFRs
from six ‘‘leading U.S. mask
manufacturers’’ were selected for
study.10 The different models were
selected to represent a range of styles:
six cup-shaped, two horizontal flat-fold,
and two vertical flat-fold models. No
information was provided in the
9 Richardson, A.W. et al. (2014b), ‘‘Evaluation of
a Faster Fit Testing Method for Filtering Facepiece
Respirators Based on the TSI PortaCount,’’ Journal
of the International Society for Respiratory
Protection 31(1): 43–56 (OSHA–2015–0015–0006).
10 The authors chose not to identify the specific
respirator models ‘‘because the intentional missizing and lack of performing a user seal check
would misrepresent performance of these
respirators when used as part of a proper
respiratory protection program’’ (OSHA–2015–
0015–0006).
PO 00000
Frm 00033
Fmt 4700
Sfmt 4700
50743
publication about whether models were
available in different sizes. However, at
OSHA’s request, TSI submitted the
following additional information
regarding the choice of respirators
(OSHA–2015–0015–0010):
The study plan for FFR called for 10 N95
FFR. Unlike elastomeric respirators, FFR
designs vary widely and are typically not
offered in different sizes. The authors felt it
was important to use a variety of designs that
represent the styles currently available in the
US. Of the 10 models used, 6 were cupshaped, 2 were vertical-fold, and 2 were
horizontal-fold designs. The cup-shaped style
is by far the most common, which is why 6
of the 10 model selected have that
fundamental design. Four flat-fold designs (2
vertical-fold and 2 horizontal-fold) models
are also included.
Respirators were probed with a flush
sampling probe located between the
nose and mouth. Lightweight sample
tubing and neck straps were used to
ensure the tubing did not interfere with
respirator fit. Twenty-nine participants
(11 female; 18 male) were included in
the study. The reference method, test
aerosol, and most other study
procedures were analogous to those
used for the Fast-Half and Fast-Full
methods. However, the Fast-FFR
method employed these four exercises:
Bending, talking, head side-to-side, and
head up-and-down with the same
sampling sequence and durations as the
other test protocols. The talking exercise
replaces the jogging exercise used in the
Fast-Half and Fast-Full methods. TSI
decided not to eliminate the talking
exercise for FFRs even though their
pilot study indicated that it rarely
produces the lowest fit factor (OSHA–
2015–0015–0008). They felt from their
own experience that jogging does not
represent the kind of motions that FFR
wearers do when using the respirator
(OSHA–2015–0015–0008). TSI also
indicated that the sampling probe
configured on lightweight FFR
respirators caused the respirator to pull
down and away from the face during
jogging creating unintentional leakage.
A PortaCount® Model 8038 operated in
the N95 mode (TSI Inc., Shoreview MN)
was used to measure aerosol
concentrations throughout the
experiments. The particle
concentrations in the test chamber were
expected to be greater than 400 p/cm3.
A minimum fit factor of 100 is required
in order to be regarded as an acceptable
fit for these types of respirators under
appendix A of the Respiratory
Protection Standard.
b. Richardson Study Results
The study administered sequential
paired fit tests using the Fast-FFR
E:\FR\FM\26SER1.SGM
26SER1
50744
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
method and a reference method
according to the ANSI annex. The study
authors randomized the order of the two
sets of fit test exercises for each test
subject. The study authors determined
the variability associated with the
reference method using 63 pairs of fit
factors from 14 participants. They
defined the exclusion zone as fit factor
measurements within one standard
deviation of the 100 pass/fail value.
Two pairs of fit factors were omitted by
the study authors because the normal
breathing fit factor ratio exceeded 100,
and six pairs of fit factors were omitted
because they were identified as outliers
(>3 standard deviations from the mean
of the remaining data points). The
exclusion zone calculated by the study
authors ranged from 78 to 128 and did
not include the six outliers. OSHA
recalculated the exclusion zone with the
outlier data included in the analysis
(OSHA–2015–0015–0009). The
recalculated exclusion zone was
somewhat wider, ranging from 69 to
144.
The final dataset for the ANSI FastFFR performance evaluation included
114 pairs of fit factors from 29
participants. The respirator models were
used in nearly equal proportion. The
authors omitted two pairs because the
ratio of maximum to minimum normal
breathing fit factors was greater than
100, leaving 112 pairs for the data
analysis.
The study authors concluded that
their statistical analysis indicates that
the Fast-FFR method met the required
acceptance criteria for test sensitivity,
predictive value of a pass, predictive
value of a fail, test specificity, and
kappa statistic as defined in the ANSI
annex (see Table 1). The same was
found by OSHA’s statistical analysis,
utilizing the wider OSHA-recalculated
exclusion zone, which excluded an
additional four pairs for a total of 11
pairs excluded and a 102 pairs included
in the analysis. OSHA therefore agrees
with the study that the Fast-FFR method
can identify poorly fitting respirators at
least as well as the reference method.
TABLE 1—COMPARISON OF FIT TEST PROTOCOLS WITH ANSI CRITERIA
ANSI Z88.10
Sensitivity .........................................................................................................
PV Pass ...........................................................................................................
Specificity .........................................................................................................
PV Fail .............................................................................................................
Kappa ...............................................................................................................
Fast-full
≥0.959
≥0.95
≥0.50
≥0.50
≥0.70
0.98
0.98
0.98
0.98
0.97
Fast-half
0.96
0.97
0.97
0.93
1 0.89
Fast-FFR
1.00
1.00
0.85
0.93
1 0.89
1 The kappa values in the table are those determined using the OSHA recalculated exclusion zone. The kappa values reported by the study
authors using a narrower exclusion zone were 0.90 and 0.87, respectively, for the Fast-Half and Fast-FFR methods.
Other statistical values were the same for both OSHA and study author exclusion zone determinations.
khammond on DSKJM1Z7X2PROD with RULES
C. Consensus Standards
While appendix A of OSHA’s
Respiratory Protection Standard
specifies the procedure for adding new
fit testing protocols to the standard, it
does not specify any particular
method(s) or criteria for evaluating a
new fit test. Section 6(a) of the Act
directs the Secretary of Labor to
promulgate by rule ‘‘as an occupational
safety or health standard any national
consensus standard . . . unless he
determines that the promulgation of
such a standard would not result in
improved safety or health for
specifically designated employees.’’ 29
U.S.C. 655(a). Section 6(b)(8) of the Act
further states: ‘‘Whenever a rule
promulgated by the Secretary differs
substantially from an existing national
consensus standard, the Secretary shall,
at the same time, publish in the Federal
Register a statement of the reasons why
the rule as adopted will better effectuate
the purposes of this Act than the
national consensus standard.’’ 29 U.S.C.
655(b)(8). And OSHA has a long history
of considering national safety and
health consensus standards, such as
ANSI and NFPA (National Fire
Protection Association), in developing
its own standards.
The National Technology Transfer
and Advancement Act of 1995 similarly
endorses agencies’ use of national
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
consensus standards: ‘‘all Federal
agencies and departments shall use
technical standards that are developed
or adopted by voluntary consensus
standards bodies, using such technical
standards as a means to carry out policy
objectives or activities determined by
the agencies and departments.’’ Public
Law 104–113, section 12(d), 110 Stat.
775, 783 (1996), 15 U.S.C. 272 note.
ANSI/AIHA is such a voluntary
consensus standards body, whose
standards, including Z88.10, are widely
recognized and accepted by the
industrial hygiene community. OSHA
concurs with ANSI that ‘‘this annex
[A2] provides a specific procedure for
evaluating fit test methods against the
current body of knowledge.’’ OSHA
therefore considers the annex’s
procedure to be a valid, acceptable
method for evaluating new fit test
protocols (ANSI/AIHA, 2010).
D. Comments to the Proposal
In the October 2016 NPRM, OSHA
preliminarily determined that the new
protocols met the sensitivity, specificity,
predictive value, and other criteria
outlined in the ANSI annex and would,
therefore, provide employees with at
least as much protection as the reference
method. That reference method
consisted of the standard OSHA
exercises listed in Section I.A.14 of
appendix A of the Respiratory
PO 00000
Frm 00034
Fmt 4700
Sfmt 4700
Protection Standard (which are the eight
test exercises used for the original
ambient aerosol CNC protocol), minus
the grimace exercise, in the same order
as described in the standard (i.e., normal
breathing, deep breathing, head side-toside, head up-and-down, talking,
bending over, normal breathing). OSHA
further concluded that it was reasonable
to remove the grimace exercise from the
reference method during the method
comparison testing, because its
inclusion would unpredictably impact
respirator fit (see Question #10 below
for a more detailed discussion). After
having considered the comments
submitted in response to the NPRM
(discussed below), OSHA has concluded
that it is appropriate to amend appendix
A of the Respiratory Protection standard
to include the proposed fit test
protocols.
In the NPRM, OSHA invited public
comment on the accuracy and reliability
of the proposed protocols, their
effectiveness in detecting respirator
leakage, and their usefulness in
selecting respirators that will protect
employees from airborne contaminants
in the workplace. OSHA invited public
comment on the following specific
questions:
1. Were the three studies described in
the peer-reviewed journal articles well
controlled and conducted according to
E:\FR\FM\26SER1.SGM
26SER1
khammond on DSKJM1Z7X2PROD with RULES
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
accepted experimental design practices
and principles?
2. Were the results of the three studies
described in the peer-reviewed journal
articles properly, fully, and fairly
presented and interpreted?
3. Did the three studies treat outliers
appropriately in determination of the
exclusion zone?
4. Will the two proposed protocols
generate reproducible fit testing results?
5. Will the two proposed protocols
reliably identify respirators with
unacceptable fit as effectively as the
quantitative fit testing protocols,
including the OSHA-approved standard
PortaCount® protocol, already listed in
appendix A of the Respiratory
Protection Standard?
6. Did the protocols in the three
studies meet the sensitivity, specificity,
predictive value, and other criteria
contained in the ANSI/AIHA Z88.10–
2010, Annex A2, Criteria for Evaluating
Fit Test Methods?
7. Are the specific respirators selected
in the three studies described in the
peer-reviewed journal articles
representative of the respirators used in
the United States?
8. Does the elimination of certain fit
test exercises (e.g., normal breathing,
deep breathing, talking) required by the
existing OSHA-approved standard
PortaCount® protocol impact the
acceptability of the proposed protocols?
9. Is the test exercise, jogging-in-place,
that has been added to the Fast-Full and
Fast-Half protocols appropriately
selected and adequately explained?
Should the jogging exercise also be
employed for the Fast-FFR protocol? Is
the reasoning for not replacing the
talking exercise with the more rigorous
jogging exercise in the Fast-FFR
protocol (as was done in Fast-Full and
Fast-Half) adequately explained?
10. Was it acceptable to omit the
grimace from the reference method
employed in the studies evaluating
performance of the proposed fit testing
protocols? Is it appropriate to exclude
the grimace completely from the
proposed protocols, given that it is not
used in the calculation of the fit factor
result specified under the existing or
proposed test methods? If not, what
other criteria could be used to assess its
inclusion or exclusion?
11. The protocols in the three studies
specify that participants take two deep
breaths at the extreme of the head sideto-side and head up-and-down exercises
and at the bottom of the bend in the
bend-forward exercise. According to the
developers of these protocols, the deep
breaths are included to make the
exercises more rigorous and
reproducible from one subject to the
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
next. Are these additional breathing
instructions adequately explained in the
studies and in the proposed amendment
to the standard? Are they reasonable
and appropriate?
12. Does OSHA’s proposed regulatory
text for the two new protocols offer clear
instructions for implementing the
protocols accurately?
OSHA received 27 comments from 25
separate individuals, with one
individual submitting three separate
comments (OSHA–2015–0015–0015 to
OSHA–2015–0015–0042). In addition,
TSI submitted a comment several
months after the close of the comment
period (OSHA–2015–0015–0047).
OSHA added TSI’s comment to the
docket as a late submission in the
interest of full disclosure but did not
take it into account.
Of the 27 timely comments, six did
not specifically address any of OSHA’s
specific questions, but were generally in
favor of the proposed protocols (OSHA–
2015–0015–0016, OSHA–2015–0015–
0018, OSHA–2015–0015–0019, OSHA–
2015–0015–0020, OSHA–2015–0015–
0030, OSHA–2015–0015–0039). Among
other things, these comments agreed
that the abbreviated protocols would
save time and resources and would
increase employer compliance with
safety and health regulations.
OSHA addresses below the comments
that addressed the NPRM’s specific
questions:
1. Were the three studies described in
the peer-reviewed journal articles well
controlled and conducted according to
accepted experimental design practices
and principles?
The majority of concerned comments
about the proposed protocols related to
the experimental design and methods
used in the three Richardson studies
supporting the proposed protocols. The
most common of these criticisms was
that the testing was not representative of
‘‘real world’’ settings (OSHA–2015–
0015–0022, OSHA–2015–0015–0025,
OSHA–2015–0015–0026, OSHA–2015–
0015–0027, OSHA–2015–0015–0032,
OSHA–2015–0015–0033, OSHA–2015–
0015–0040, OSHA–2015–0015–0041,
OSHA–2015–0015–0042). For example,
one commenter asserted that the
environment of the test chambers used
in the three Richardson studies was ‘‘too
controlled’’ and that the studies ‘‘did
not allow for variables encountered by
fit test providers when conducting fit
testing in real world settings’’ (OSHA–
2015–0015–0026). Another commenter
stated: ‘‘In an uncontrolled environment
many factors, including but not limited
to, ventilation, doors being opened, and
room temperature can greatly affect the
PO 00000
Frm 00035
Fmt 4700
Sfmt 4700
50745
particle count in a relatively short time’’
(OSHA–2015–0015–0040).
Regarding these comments, OSHA
would like to stress that the proposed
protocols were evaluated using the
criteria outlined in Annex A2 of the
ANSI/AIHA Z88.10–2010 standard,
which does not require uncontrolled
testing conditions with variables such as
fluctuating climate, temperature,
elevation, air currents, ventilation, etc.
OSHA considers the ANSI annex
method to be a valid method for
evaluating new fit test protocols.
Many of these comments related
specifically to the use of generated
aerosols in the three Richardson studies
(OSHA–2015–0015–0022, OSHA–2015–
0015–0026, OSHA–2015–0015–0033,
OSHA–2015–0015–0041). For example,
one commenter stated:
The PortaCount® was designed and
marketed to be used for conducting
quantitative fit tests using room aerosols,
whereas the supporting studies were
conducted in a test chamber using a
generated aerosol. Concentrations of room
aerosols are typically about 1x103 p/cc,
whereas in these studies the average
challenge concentrations were about 2x104
p/cc. . . . I would recommend that the
protocols not be accepted until these
validation tests are conducted using ambient
aerosols. . . . (OSHA–2015–0015–0033).
Another commenter questioned why the
study authors used generated aerosol in
a test chamber when their goal was to
prove the acceptability of a new ambient
aerosol test protocol (OSHA–2015–
0015–0041).
None of the three Richardson studies,
however, employed a ‘‘generated
aerosol’’ atmosphere as described in the
ANSI/AIHA Z88.10 standard; instead,
they used ‘‘the ambient laboratory
aerosol which was augmented by NaCl
particles from a TSI Model 8026 Particle
Generator’’ (OSHA–2015–0015–0004,
OSHA–2015–0015–0005, OSHA–2015–
0015–0006). This approach is allowed
by ANSI/AIHA in Annex A2, which
states that ‘‘a proposed modification to
an accepted QNFT [quantitative fit
testing] protocol can be evaluated using
the accepted protocol for that
instrument as the reference standard.’’
As some commenters noted (OSHA–
2015–0015–0031, OSHA–2015–0015–
0041), it is often necessary to augment
the ambient environment when using
the original OSHA-approved ambient
aerosol CNC fit test method in a
relatively clean office environment. The
TSI particle generator is one of several
approaches commonly used (OSHA–
2015–0015–0051, OSHA–2015–0015–
0050). In fact, as noted by one
commenter, technicians sometimes burn
candles or incense in order to reach and
E:\FR\FM\26SER1.SGM
26SER1
khammond on DSKJM1Z7X2PROD with RULES
50746
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
maintain ambient particle counts
(OSHA–2015–0015–0032). OSHA has
concluded that there is no material
difference between the experimental
atmosphere employed in the three
Richardson studies and the atmosphere
commonly used for quantitative fit
testing with the ambient aerosol CNC
method.
Other commenters expressed
concerns that the ambient and purge
times were too short (OSHA–2015–
0015–0022, OSHA–2015–0015–0026,
OSHA–2015–0015–0027, OSHA–2015–
0015–0032, OSHA–2015–0015–0033,
OSHA–2015–0015–0036, OSHA–2015–
0015–0038, OSHA–2015–0015–0041,
OSHA–2015–0015–0042). For example,
one commenter recommended that the
proposed protocols ‘‘should provide for
suitable ambient and respirator purge
durations to address the full range of
particle concentrations that the device is
recommended for use in instead of
selecting a duration based on the
optimum conditions that were selected
for the studies. . . .’’ (OSHA–2015–
0015–0026). Several commenters were
also concerned that each ambient
sample conducted at the beginning and
end of the new protocols lasted only
five seconds (OSHA–2015–0015–0032,
OSHA–2015–0015–0036, OSHA–2015–
0015–0042).
Regarding these comments, OSHA
notes that for every exercise (except the
grimace), the original OSHA-approved
ambient aerosol CNC protocol involves
a 4-second ambient purge, a 5-second
ambient sample, and an 11-second mask
purge, followed by a 40-second mask
sample. A final 4-second ambient purge
and 5-second ambient sample occur
after the last 40-second exercise (normal
breathing) mask sample. The proposed
protocols employ the same 4-second
ambient purge, 5-second ambient
sample, and 11-second mask purge,
followed by 4 consecutive 30-second
mask samples during each of the 4
exercises, and a final 4-second ambient
purge and 5-second ambient sample.
The ambient purge and sample times are
the same. The new protocols differ from
the original OSHA-approved sampling
protocol in these ways: The ambient
environment is measured only at the
beginning and end of the exercises and
not between each exercise, mask
purging occurs just once (after the first
ambient sample), and mask sampling
time is 30 seconds rather than 40
seconds. Additionally, requirements for
conducting the fit test in an
environment with an adequate particle
concentration also did not change; they
have been standard practice for the
ambient aerosol CNC fit test method
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
since its inception and approval by
OSHA.
Regarding ambient measurements, the
only difference between the new
protocols and the original OSHAapproved protocol is that the new
protocols take measurements at the
beginning and end of the exercises,
while the original protocol does so
between each exercise. Because the total
duration of the new protocols is much
shorter than the original—2.5 minutes
versus 7.2 minutes—OSHA has
concluded that there is no need to take
periodic samples between exercises. In
particular, the time between the two
ambient samples in the proposed
protocol is 2 minutes 15 seconds,
compared to 55 seconds between each
ambient sample in the original protocol.
This minor difference is unlikely to
introduce any significant errors if fit
testers follow standard practice: (1)
Ensure the aerosol concentration falls
between 1,000 and 30,000 particles/cm3
(p/cm3) for filters with a NIOSH
designation of N/R/P–99 or 100, and 30
to 1,500 p/cm3 for filters with a N/R/P–
95 designation; and (2) do not augment
the ambient environment if the
concentration exceeds 8000 p/cm3 or
800 p/cm3 for the 99/100 or the 95
filters, respectively (OSHA–2015–0015–
0049).
Two commenters expressed concern
over eliminating purging between
exercises altogether (OSHA–2015–0015–
0022, OSHA–2015–0015–0038). But
there is no reason for purging between
the different exercises in the proposed
protocol because the instrument
continues to sample from the same
environment (inside the facepiece)
throughout the exercises. Particles
measured during the first few seconds of
transition from one exercise to the next
will have almost no influence on the
average concentration over a 30-second
exercise sampling period.
Purging ensures that the sensing
volume evaluates particles from the
correct environment and is only
necessary when switching between
ambient and mask samples or vice
versa. The proposed protocols do not
switch between ambient and mask
sampling during the exercises, so
purging is not required.
Some commenters requested further
review of the methodology of the three
Richardson studies or further validation
testing by a ‘‘third party’’ (OSHA–2015–
0015–0029, OSHA–2015–0015–0040).
OSHA notes that the studies were
conducted by a third party, Battelle
Memorial Institute, and the study
methods were approved by Battelle’s
Institutional Review Board. In addition,
NIOSH stated that their ‘‘review
PO 00000
Frm 00036
Fmt 4700
Sfmt 4700
determined that the three methods met
the criteria contained in the ANSI/AIHA
Z88.10–2010, Annex A2’’ (OSHA–2015–
0015–0031). And one commenter who
had some concerns about the proposed
protocols conceded that the ‘‘referenced
peer-reviewed articles in J. of
Respiratory Protection appear to meet
the mathematical and statistical criteria
we expect’’ (OSHA–2015–0015–0024).
Finally, the publication of the three
Richardson studies in a peer-reviewed
industrial hygiene journal suggests they
were well-controlled and conducted
according to accepted experimental
design practices and principles. In
summary, OSHA determined that the
public comments did not identify any
significant shortcomings in the
experimental design and methodology
used in the three studies.
2. Were the results of the three studies
described in the peer-reviewed journal
articles properly, fully, and fairly
presented and interpreted?
Although critical of the fact that the
studies were conducted in a test
chamber as opposed to a real world
setting, one commenter stated ‘‘that
under the specific set of conditions that
the tests were performed that they were
presented well’’ (OSHA–2015–0015–
0026). But another commenter
expressed that it was ‘‘impossible to
determine if the articles were properly,
fully, and fairly presented and
interpreted’’ because the articles did not
provide data tables listing ‘‘respirator
make, model, style, size, individuals
tested, and the paired results of the new
test and the reference test’’ as outlined
in the ANSI annex (OSHA–2015–0015–
0038). The annex recommends—but
does not require—such tables, and it is
often difficult to publish a peerreviewed article containing a complete
dataset. Regardless, OSHA reviewed the
full datasets provided by TSI as part of
the review of the study protocols, and
no commenters asked to see the
datasets. In summary, OSHA finds that
the public comments did not identify
any significant shortcomings in the way
that the results of the three journal
articles were presented or interpreted.
3. Did the three studies treat outliers
appropriately in determination of the
exclusion zone?
While OSHA disagreed with the
studies’ omissions of outliers in
calculating exclusion zones, OSHA
recalculated exclusion zones with the
outlier data included, and the results of
the re-analysis did not change any of the
studies’ conclusions. In addition,
NIOSH considered the study authors’
identification of outliers to be ‘‘a
reasonable method for diagnosing/
identifying outliers’’ (OSHA–2015–
E:\FR\FM\26SER1.SGM
26SER1
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
0015–0031). Finally, no commenters
expressed concern about the treatment
of outliers. OSHA concludes that the
treatment of outliers in the studies did
not undermine any of the studies’
results or conclusions.
4. Will the two proposed protocols
generate reproducible fit testing results?
Some commenters questioned the
reproducibility of fit testing results
using the two proposed protocols
(OSHA–2015–0015–0022, OSHA–2015–
0015–0042), but did not offer any
compelling data or research suggesting
their non-reproducibility. One of these
commenters had concerns based on
NIOSH’s recommendation that OSHA
(OSHA–2015–0015–0042) conduct
additional research to gather evidence
for a more informed decision. The
commenter stated:
appendix A of the Respiratory
Protection Standard?
Several commenters questioned not
only the acceptability of the proposed
protocols, but also the validity of the
original ambient aerosol particle
counting quantitative method already
accepted by OSHA and listed in
appendix A (OSHA–2015–0015–0022,
OSHA–2015–0015–0026, OSHA–2015–
0015–0027, OSHA–2015–0015–0029).
Some of these commenters were also of
the opinion that the CNP-based fit
testing methods are superior to other
quantitative fit testing methods. One
commenter (OSHA–2015–0015–0042)
stated that the following NIOSH
‘‘statement raises major concerns to the
ability & proven accuracy of this
proposed protocol to identify respirators
with unacceptable fit’’:
With this recommendation OSHA should
not accept a protocol that still needs further
evidence to show it will produce
reproducible fit testing results. There are too
many respirators and employees in
hazardous conditions to allow a protocol to
move forward that isn’t fully vetted and
accurate (OSHA–2015–0015–0042).
Evidence is not available in the literature
to assess whether the two proposed protocols
reliably identify respirators with
unacceptable fit as effectively as the other
accepted quantitative fit testing protocols
(generated aerosol and controlled negative
pressure (CNP)). It is recommended that
further side-by-side studies be conducted to
test the equivalency of the new PortaCount
Fast-Fit methods in identifying poorly fitting
respirators as effectively as the OSHAaccepted CNP testing; potentially, tests using
other ‘‘generated aerosols’’ would be needed
to determine whether the methods are
equivalent (OSHA–2015–0015–0031).
OSHA believes this commenter took
NIOSH’s comment out of context. The
NIOSH response to this question—in its
entirety—is the following:
khammond on DSKJM1Z7X2PROD with RULES
The studies used the OSHA-accepted
ambient aerosol condensation nuclei counter
(CNC) quantitative fit testing protocol as the
reference method. This method has been
shown to produce reproducible fit testing
results [Zhuang et al. 1998; Coffey et al.
2002]. Using the procedures and
requirements of ANSI Z88.10–2010, the
abbreviated methods provided results
comparable to the reference method.
Therefore, the proposed protocols are
anticipated to generate reproducible results.
NIOSH recommends that additional research
be conducted to provide evidence for a more
informed decision (OSHA–2015–0015–0031).
While additional research is always
valuable, OSHA agrees with NIOSH that
the proposed protocols are anticipated
to generate reproducible results. The
proposed protocols were evaluated
based on the approach specified in the
ANSI annex, which provides a specific
procedure for evaluating fit test methods
‘‘against the current body of knowledge’’
and is considered a valid method by
much of the industrial hygiene
community. Having met the criteria of
the ANSI annex, OSHA concludes that
the proposed protocols will generate
reproducible fit testing results.
5. Will the two proposed protocols
reliably identify respirators with
unacceptable fit as effectively as the
quantitative fit testing protocols,
including the OSHA-approved standard
PortaCount® protocol, already listed in
VerDate Sep<11>2014
17:31 Sep 25, 2019
Jkt 247001
Although NIOSH recommended future
research, it nonetheless recommended
that OSHA accept the proposed
protocols. In its review of the three
Richardson studies, NIOSH also
determined that the proposed protocols
conform to the requirements of the
ANSI annex.
The validity of the original OSHAapproved ambient aerosol CNC fit
testing protocol was never under
question in this rulemaking. Appendix
A of OSHA’s Respiratory Protection
Standard states that quantitative fit
testing using ambient aerosol as the test
agent and appropriate instrumentation
(condensation nuclei counter) to
quantify the respirator fit has ‘‘been
demonstrated to be acceptable.’’ In
addition, the members of the ANSI/
AIHA Z88.10 ‘‘Respirator Fit Testing
Methods’’ committee, who represent
many of the nation’s leading respiratory
protection experts, opted to retain,
rather than reject, this method as an
acceptable quantitative fit testing
method when they updated the national
consensus standard in 2010.
Furthermore, the proposed protocols
were evaluated using the method
described in the ANSI annex, which
does not require a statistical comparison
against the CNP method (OSHA–2015–
PO 00000
Frm 00037
Fmt 4700
Sfmt 4700
50747
0015–0007). Likewise, OSHA’s
Respiratory Protection Standard does
not require that a new fit testing
protocol be compared to the CNP
method, or any other specific fit testing
method. Moreover, just as OSHA does
not rank specific makes and models of
respirators, OSHA also does not rank fit
testing methods. Each fit testing method
has its own advantages and
disadvantages.
In summary, OSHA determined that
the new protocols met the sensitivity,
specificity, predictive value, and other
criteria outlined in the ANSI annex and
will, therefore, provide employees with
protections comparable to protections
afforded to them by the reference
method, which consisted of the
standard OSHA exercises listed in
Section I.A.14 of appendix A of the
Respiratory Protection Standard, minus
the grimace exercise, in the same order
as described in the standard (i.e., normal
breathing, deep breathing, head side-toside, head up-and-down, talking,
bending over, normal breathing). These
are the same test exercises, minus the
grimace, that are utilized for both the
CNC and CNP protocols. OSHA
concluded that it was reasonable to
remove the grimace exercise from the
reference method during the method
comparison testing, because its
inclusion would unpredictably impact
respirator fit within each pair of data
comparing the current and new fit test
protocols (see Question #10 below for a
more detailed discussion).
6. Did the protocols in the three
studies meet the sensitivity, specificity,
predictive value, and other criteria
contained in the ANSI/AIHA Z88.10–
2010, Annex A2, Criteria for Evaluating
Fit Test Methods?
One commenter stated that evaluating
the sensitivity of the new protocols
‘‘presents a quandary because the
sensitivity of the standard PortaCount
protocol has itself not been established’’
(OSHA–2015–0015–0022). As discussed
under question #5, the validity of the
original OSHA-approved ambient
aerosol CNC fit testing protocol is not at
issue in this rulemaking.
OSHA’s evaluation of the proposed
protocols determined that they met the
criteria outlined in the ANSI annex (see
sections A–B above). In addition,
NIOSH stated that their ‘‘review
determined that the three methods met
the criteria contained in the ANSI/AIHA
Z88.10–2010, Annex A2’’ (OSHA–2015–
0015–0031). Another commenter agreed
that ‘‘the submitted request has
followed the defined procedures and the
results fit within the statistical limits set
forth in ANSI Z88.10–2010’’ (OSHA–
2015–0015–0035). Furthermore, OSHA
E:\FR\FM\26SER1.SGM
26SER1
khammond on DSKJM1Z7X2PROD with RULES
50748
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
determined that the public comments
did not provide any substantive data or
information suggesting that the
proposed protocols in the three studies
did not meet the sensitivity, specificity,
predictive value, and other criteria
contained in the ANSI annex.
7. Are the specific respirators selected
in the three studies described in the
peer-reviewed journal articles
representative of the respirators used in
the United States?
One commenter questioned the ‘‘very
small sample of the wide range of tight
sealing respirators that were used in the
[studies]’’ (OSHA–2015–0015–0029),
and another expressed that ‘‘the small
sample size of respirators chosen for
testing lends itself to being less than
ideal’’ (OSHA–2015–0015–0040).
However, neither commenter provided
specific recommendations or statistical
data regarding the numbers and types of
respirators that should have been
selected or why. Further, the industrial
hygiene research community does not
require a specified sample size of
respirators to assess fit testing protocols.
Finally, had the respirator sample size
been too small to produce reliable
results, the studies likely would not
have been accepted for publication in a
peer-reviewed journal.
One commenter questioned why the
Richardson studies included only
filtering facepiece respirators without
exhalation valves, noting that many
users opt to wear filtering facepiece
respirators with exhalation valves for
comfort reasons (OSHA–2015–0015–
0026). But an exhalation valve does not
affect respirator fit. While the study
authors did not explain how they
selected the respirator models and
designs, OSHA has determined that the
public comments did not identify any
significant shortcomings in respirator
selection and believes that the models
and designs selected for the three
experiments were appropriately
representative.
8. Does the elimination of certain fit
test exercises (e.g., normal breathing,
deep breathing, talking) required by the
existing OSHA-approved standard
PortaCount® protocol impact the
acceptability of the proposed protocols?
Several commenters expressed
concern over removing certain fit test
exercises (OSHA–2015–0015–0021,
OSHA–2015–0015–0024, OSHA–2015–
0015–0025, OSHA–2015–0015–0029,
OSHA–2015–0015–0032, OSHA–2015–
0015–0033, OSHA–2015–0015–0038,
OSHA–2015–0015–0041), but did not
provide any peer-reviewed data or
published research to support their
opinions. Three commenters (OSHA–
2015–0015–0021, OSHA–2015–0015–
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
0025, OSHA–2015–0015–0032)
expressed concern about removing the
talking exercise, because they had
experienced fit test failures during the
talking exercise when fit testing
workers. Another commenter felt that
‘‘it doesn’t make sense to eliminate [the
talking] exercise simply because it
wasn’t the worst contributing exercise
with poor fitting respirators’’ (OSHA–
2015–0015–0033). A third suggested
retaining the head side-to-side, head upand-down, and talking exercises
because he believes they are currently
the most rigorous exercises (OSHA–
2015–0015–0024).
Another commenter suggested that
‘‘the conclusion to eliminate Normal
Breathing 2 (NB2) from the Fast Full
Protocol is extremely subjective’’ and
questioned how ‘‘NB2 [normal breathing
#2] could be eliminated and UD
[moving head up and down] kept if
there is no correlation with the study
data?’’ (OSHA–2015–0015–0038). This
commenter suggested increasing the
purge time to improve the ability of the
NB2 exercise to detect poor fits.
Regarding this question, OSHA has
concluded that TSI properly excluded
the second normal breathing exercise. In
TSI’s study of the Fast-Full method, the
second normal breathing exercise had
the lowest fit factor 19% of the time for
poor-fitting respirators. While this score
normally indicates an exercise was
effective at detecting poor-fitting
respirators, TSI concluded that score
was anomalous because the
corresponding score for the first normal
breathing (NB1) exercise was 0%. TSI
reasoned the 19% score was a result of
particles introduced into the facepiece
during the preceding (bending over)
exercise that were not purged (OSHA–
2015–0015–0008). Increasing the purge
time to clear such particles would not,
as the commenter suggests, improve the
ability of the NB2 exercise to detect
poor fits. Instead, NB2 would likely be
as ineffective as NB1, which was never
the lowest fit factor for any poor-fitting
respirators. This is also supported by
the fact that the NB1 and NB2 exercises
produced the lowest fit factors only 2%
and 5% of the time, respectively, for
good-fitting respirators.
One commenter noted that
‘‘[e]limination of the normal breathing,
deep breathing, and talking fit test
exercises from the proposed Fast
protocols has significant potential for
adverse impact on PortaCount fit test
results in the real world’’ (OSHA–2015–
0015–0022). With respect to normal
breathing and talking, the commenter
noted that several studies not
mentioned by the three Richardson
studies indicate that the first normal
PO 00000
Frm 00038
Fmt 4700
Sfmt 4700
breathing exercise fit factor is typically
lower than fit factors from all
subsequent exercises and that the
talking exercise also often results in a
lower fit factor. But this commenter did
not provide any basis to believe
eliminating these exercises will put
workers at risk. Indeed, he conceded
that ‘‘respirator donning has a greater
effect on respirator fit than do fit test
exercises’’ and ‘‘the lower fit factors
produced by the talking exercise appear
to be more consistent with sampling
artifact than with actual exercise
dynamics.’’ And, as TSI explained, fit
factors for the second normal breathing
exercise are likely to be contaminated
by prior exercises (OSHA–2015–0015–
0008). Finally, this commenter offered
no data or published information that
suggest deep breathing is more rigorous
than other exercises or that eliminating
deep breathing will put workers at risk.
One commenter (OSHA–2015–0015–
0029) stated that ‘‘our experience
strongly suggests that the Deep
Breathing and Talking Exercises are
frequently the exercises that see the
lowest fit factors calculated and often
are ‘THE Exercises’ which determine
whether a respirator wear will achieve
a Pass or Failure following the
completion of the fit test series of
exercises.’’ He further suggested ‘‘a more
thorough evaluation of this change by a
third party such as NIOSH–
NPPTL. . . .’’ Another commenter
requested that a review of the studies be
performed by an independent third
party (OSHA–2015–0015–0040).
NIOSH/NPPTL did in fact review and
evaluate the studies. In the comments
NIOSH submitted to OSHA, NIOSH did
not express any concern over the
removal of the talking exercise and
ultimately ‘‘recommend[ed] that OSHA
accept the three protocols’’ (OSHA–
2015–0015–0031).
Regarding all these comments, the
industrial hygiene community has not
come to a consensus as to which test
exercises must be used in a new fit
testing protocol. Neither the ANSI
annex nor OSHA’s appendix requires
any specific test exercise(s) be used in
a new fit testing protocol. Further, in
2004, OSHA approved an abbreviated
version of the CNP protocol, called the
CNP REDON protocol, which excludes
the deep breathing and talking
exercises, and includes only the facing
forward (same as normal breathing),
bending over, and head shaking
exercises. In sum, the information
submitted in the public comments did
not convince OSHA that the elimination
of the deep breathing and talking
exercises adversely impacted the
acceptability of the proposed protocols,
E:\FR\FM\26SER1.SGM
26SER1
khammond on DSKJM1Z7X2PROD with RULES
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
which met the sensitivity, specificity,
predictive value, and other criteria
contained in the ANSI annex.
9. Is the test exercise, jogging-in-place,
that has been added to the Fast-Full and
Fast-Half protocols appropriately
selected and adequately explained?
Should the jogging exercise also be
employed for the Fast-FFR protocol? Is
the reasoning for not replacing the
talking exercise with the more rigorous
jogging exercise in the Fast-FFR protocol
(as was done in Fast-Full and Fast-Half)
adequately explained?
One commenter was of the opinion
that ‘‘[t]he jogging exercise, while
rigorous, is not representative of real-life
civilian activities’’ (OSHA–2015–0015–
0024). NIOSH stated that it would have
liked to have seen references to support
that the jogging-in-place exercise used
in the protocols for elastomeric
respirators was aggressive in evaluating
the respirator seal. However, this did
not prevent NIOSH from recommending
that OSHA approve the proposed
protocols (OSHA–2015–0015–0031).
Furthermore, as stated above under
question #8, the industrial hygiene
community has not come to a consensus
as to which test exercise(s) must be
included in new fit testing protocols.
More importantly, neither the ANSI
annex nor OSHA’s appendix requires
that any specific test exercise(s) be used
in a new fit testing protocol.
10. Was it acceptable to omit the
grimace from the reference method
employed in the studies evaluating
performance of the proposed fit testing
protocols? Is it appropriate to exclude
the grimace completely from the
proposed protocols, given that it is not
used in the calculation of the fit factor
result specified under the existing or
proposed test methods? If not, what
other criteria could be used to assess its
inclusion or exclusion?
One commenter (OSHA–2015–0015–
0026) stated that he ‘‘seriously
question[s] the choice of the study and
protocol authors in removing the
Grimace exercise.’’ While he ‘‘concur[s]
with their statement that it cannot be
consistently applied and with their
statement that the fit factor if measured
should not be used in calculation of the
fit factor,’’ his ‘‘interpretation is that the
importance of the grimace is not in the
fit factor achieved during this step of the
protocol but instead in the ability of the
mask to re-seal after this exercise which
goes to the respirator[’s] proper fit.’’
While NIOSH (OSHA–2015–0015–
0031) ‘‘recommends that the grimace
test be included in the abbreviated
protocols when used in the workplace
since it is part of the currently accepted
protocols,’’ NIOSH agrees that the new
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
‘‘protocols provide a valid reason for not
including [the grimace] in the method
comparison testing since it would add a
non-controlled variable.’’ Similarly,
another commenter stated:
The Grimace exercise is intended to break
the face seal and then measure the recovery
of the seal in the following exercises. By
breaking the seal in the Grimace exercise
during the reference protocol you have now
altered the original fit of the mask and
compromised the second fit test data.
Therefore it makes logical sense that this
exercise was eliminated from the test
procedure for both the reference test and the
proposed test. The fit of the mask as
originally donned is consistent for both the
reference test and the proposed protocol test
(OSHA–2015–0015–0035).
OSHA agrees that it is reasonable to
remove the grimace exercise from the
reference method during the method
comparison testing, because its
inclusion would unpredictably impact
respirator fit. Some respirator fit test
protocols include the grimace exercise
because it is believed that it will unseat
the respirator facepiece; whether this
occurs is assessed, however, only during
the subsequent exercise—fit measured
during the grimace exercise is not
included in the calculation of overall fit.
Because method comparison requires a
range of fit factors (from poor- to wellfitting respirators), OSHA believes that
excluding the short grimace exercise
allows for a more consistent assessment
of fit between the reference and new fit
test protocols.
Finally, neither the ANSI annex nor
the OSHA appendix specifies which
exercises must be used in a new fit
testing protocol. The 2010 ANSI Z88.10
standard specifically considers the
grimace exercise to be elective for the
particle-counting instrument
quantitative fit test procedure that it
describes (see Table I). And although
OSHA requires the grimace exercise as
part of the original ambient aerosol CNC
protocol, OSHA approved an
abbreviated CNP REDON protocol in
2004 that excluded the grimace exercise
among four other exercises. As such,
OSHA concludes that it is not necessary
to add the grimace exercise to the
proposed protocols.
11. The protocols in the three studies
specify that participants take two deep
breaths at the extreme of the head sideto-side and head up-and-down exercises
and at the bottom of the bend in the
bend-forward exercise. According to the
developers of these protocols, the deep
breaths are included to make the
exercises more rigorous and
reproducible from one subject to the
next. Are these additional breathing
instructions adequately explained in the
PO 00000
Frm 00039
Fmt 4700
Sfmt 4700
50749
studies and in the proposed amendment
to the standard? Are they reasonable
and appropriate?
OSHA received no comments
regarding these questions, which
suggests that the breathing instructions
were adequately explained in both the
studies and in the proposed amendment
to the standard, and that stakeholders
were not concerned about this issue.
12. Does OSHA’s proposed regulatory
text for the two new protocols offer clear
instructions for implementing the
protocols accurately?
Neither TSI nor any commenters
expressed concern about the clarity of
OSHA’s proposed regulatory text
instructions for implementing the
protocols. In the absence of such
comments, the only changes that OSHA
has made to the proposed regulatory
text include an expansion of the titles of
Tables A–1 and A–2 to match the names
of the new protocols exactly. OSHA did
this solely for clarity, so employers
correctly correlate these two new tables
with the two new proposed protocols.
Several commenters expressed
miscellaneous concerns that did not fall
directly under any of OSHA’s specific
questions for public comment. OSHA
addresses each in turn. One commenter
was not in favor of any quantitative fit
testing methods because, in his view,
qualitative fit tests are more convincing
to the respirator wearers themselves
(OSHA–2015–0015–0017):
[p]assing quantitative measurements may
be literally orders of magnitude apart. If the
machine says a 13 is passing, and a 400 is
passing as well, how are the wearers of the
respirators supposed to feel when they
compare their numbers? (I have literally seen
those numbers before entering a CBRN
Defense Training Facility (CDTF) with live
nerve and mustard agent; each individual
was concerned that his/her mask was not as
‘‘good’’ as the other’s, as they had no idea
what the numbers meant.
As an initial matter, this rulemaking
was not intended to compare qualitative
fit tests to quantitative fit tests—
employers are free to choose such tests
as appropriate under appendix A of the
Respiratory Protection Standard. The
two new protocols will serve only as
additional quantitative fit testing
options to employers. That said,
qualitative fit testing is not appropriate
for certain respirators. In fact, the
individuals described by the commenter
could not have used qualitative fit
testing because proper protection
against CBRN (chemical, biological,
radiological and nuclear) exposures
E:\FR\FM\26SER1.SGM
26SER1
50750
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
requires a full-facepiece, which must be
fit tested using a quantitative method.11
Another commenter was concerned
about shortening the protocols to less
than an eight-minute period, because
she thought that symptoms of
claustrophobia/panic attacks might not
manifest before eight minutes (OSHA–
2015–0015–0021). However, the risk of
claustrophobia/panic attacks is already
addressed when the wearer is required,
under § 1910.134(e)(1) of the
Respiratory Protection Standard, to
undergo a mandatory medical
evaluation ‘‘to determine the employee’s
ability to use a respirator, before the
employee is fit tested or required to use
the respirator in the workplace.’’ And
the mandatory medical questionnaire in
Appendix C of the standard includes a
question regarding claustrophobia. In
addition, OSHA is unaware of this
having been an issue for respirator
wearers fit tested using the CNP REDON
protocol, which also lasts less than eight
minutes and was approved by OSHA in
2004.
Two commenters who favored shorter
protocols expressed interest in making
the new protocols available on all
ambient aerosol CNC-based fit testing
instruments, particularly the older
PortaCount® (model 8020) machines
(OSHA–2015–0015–0028, OSHA–2015–
0015–0030). OSHA notes that the new
protocols are not restricted to any
particular testing instrument because
OSHA only approves fit testing
protocols, not specific fit testing
machines.12 OSHA has no authority to
require specific fit testing machines or
models for new protocols. Employers
must contact the manufacturers of CNC
fit testing machines to determine which
models support the new protocols.
khammond on DSKJM1Z7X2PROD with RULES
E. Conclusions
After reviewing the comments
submitted to the record, OSHA finds
that the two proposed modified ambient
aerosol CNC quantitative fit testing
protocols are supported by peerreviewed studies that were conducted
according to accepted experimental
design practices and principles and that
produced results that were properly,
fully, and fairly presented and
interpreted. In addition, based on the
peer-reviewed studies and comments
submitted to the record, OSHA finds
that the two proposed protocols meet
11 Qualitative fit tests are limited to negative
pressure air-purifying respirators that must achieve
a fit factor of 100 or less, i.e., they may only be used
to fit test half-mask, not full-facepiece, respirators.
29 CFR 1910.134(f)(6).
12 TSI informed OSHA that the new protocols
would not be available on the now-discontinued
8020 models (OSHA–2015–0010).
VerDate Sep<11>2014
17:37 Sep 25, 2019
Jkt 247001
the sensitivity, specificity, predictive
value, and other criteria contained in
the ANSI annex. Moreover, the
proposed protocols met the criteria of
the ANSI annex, and in the absence of
any compelling data or research in the
record that would suggest that the
proposed protocols would not generate
reproducible fit testing results, OSHA
concludes that the proposed protocols
will generate reproducible fit testing
results. In summary, OSHA concludes
that the two proposed protocols are
sufficiently accurate and reliable to
approve and include in appendix A of
its Respiratory Protection Standard.
F. N95-CompanionTM Technology
The original TSI PortaCount®
machine (model 8020) could only be
used to fit test respirators equipped with
≥99% efficient filter media (i.e., N–,
R–, or P–99 and 100 NIOSH filter
designations). In 1998, TSI introduced
the N95-CompanionTM Technology,
which, when combined with the
PortaCount® 8020 model, could be used
to fit test respirators equipped with
<99% efficient filter media (e.g., N95
NIOSH filter designation). TSI no longer
manufactures the 8020 model, which
was replaced by a second generation of
PortaCount® instruments (models 8030
and 8038). TSI introduced a third
generation of PortaCount® instruments
(models 8040 and 8048) in November
2017. Models 8030 and 8040 can only
test the most efficient filters (i.e., 99 and
100 NIOSH filter designations), while
models 8038 and 8048, which include
the N95 CompanionTM Technology
already built into the machine, can test
any type of filter by selecting the
appropriate operating mode. Because
employers are sometimes confused by
this distinction, OSHA considered using
this rulemaking to propose additional
language to Part I.C.3 of appendix A of
the Respiratory Protection Standard to
reflect this technological development.
The additional language proposed by
OSHA did not alter the fit testing
protocol or impose any new
requirements on employers; it was
merely intended for clarification
purposes.
One commenter expressed concern
over the use of the brand name
‘‘Portacount®’’ within the regulatory
text, stating that ‘‘[t]his seems to
exclude other potential CNC providers’’
(OSHA–2015–0015–0024). Regarding
this comment, the original OSHAapproved ambient aerosol CNC protocol
is often commonly referred to as the
PortaCount® protocol because of the
name of the CNC machines
manufactured by the company (i.e., TSI)
that proposed the original protocol.
PO 00000
Frm 00040
Fmt 4700
Sfmt 4700
OSHA is aware of only one other
manufacturer that produces CNC
instrumentation that is sold in the U.S.
at this time. This new CNC
instrumentation was only recently
introduced into the market, so OSHA
estimates that the overwhelming
majority of the CNC instruments used in
the U.S. at this time are still TSI
PortaCount® machines. As such, OSHA
determined that it is in the best interests
of worker health and safety to retain the
PortaCount® name within the regulatory
text, as it has appeared in appendix A
since 1998. This language is not
intended to be exclude other
manufacturers. It is intended merely to
reflect that TSI’s machines are those
typically used for this test at this point
in time. OSHA does not approve any
safety equipment or require employers
to use specific brands of safety
equipment. However, it does sometimes
refer to company or brand names when
it is in the interest of safety and health.
For example, appendix A of the
Respiratory Protection Standard also
includes the brand name (i.e., Bitrex®)
for the substance (i.e., denatonium
benzoate solution aerosol)
overwhelmingly used for one of the
OSHA-approved qualitative fit testing
protocols. In addition, appendix A
refers to the name of the company (i.e.,
Occupational Health Dynamics) that
proposed the original CNP protocol and
manufacturers CNP instrumentation.
OSHA has, however, decided not to
add the clarifying information about the
different types of PortaCount®
machines, due to commenter concerns
that the inclusion of such information
could create the appearance of a product
endorsement. Since OSHA approves fit
testing protocols rather than machines,
OSHA feels that employers can contact
fit testing instrument manufacturers for
product specificity and capabilities.
III. Procedural Determinations
A. Legal Considerations
OSHA’s Respiratory Protection
Standard is based on evidence that fit
testing is necessary to ensure proper
respirator fit for employees, which
protects them against excessive
exposure to airborne contaminants in
the workplace. Employers covered by
this revision already must comply with
the fit testing requirements specified in
paragraph (f) of OSHA’s Respiratory
Protection Standard at 29 CFR 1910.134.
OSHA has determined that the
additional modified ambient aerosol
CNC protocols provide employees with
protection that is comparable to the
protection afforded them by the existing
fit testing provisions. The additional
E:\FR\FM\26SER1.SGM
26SER1
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
modified ambient aerosol CNC protocols
do not replace existing fit testing
protocols, but instead are alternatives to
them. Therefore, OSHA finds that the
final standard does not directly increase
or decrease the protection afforded to
employees, nor does it increase
employers’ compliance burden. The
additional modified ambient aerosol
CNC protocols reduce the total fit test
duration, and therefore may reduce the
compliance burden for employers that
elect to use one of these protocols.
B. Final Economic Analysis and
Regulatory Flexibility Certification
khammond on DSKJM1Z7X2PROD with RULES
The rule is not economically
significant under Executive Order 12866
(58 FR 51735) or a ‘‘major rule’’ under
Section 804 of the Small Business
Regulatory Enforcement Fairness Act of
1996 (5 U.S.C. 804). The rule imposes
no additional costs on any private- or
public-sector entity and is not a
significant or major rule under
Executive Order 12866 or other relevant
statutes or executive orders. This
rulemaking increases employers’
flexibility in choosing fit testing
methods for employees, and the final
rule does not require an employer to
update or replace its current fit testing
method(s) if the fit testing method(s)
currently in use meets existing
standards. Furthermore, because the
rule offers additional options that
employers would be expected to select
only if those options did not impose any
net cost burdens on them, the rule will
not have a significant impact on a
substantial number of small entities.
OSHA received several comments in
response to the NPRM related to the
time savings anticipated by the
proposal. As discussed in the
‘‘Summary and Explanation,’’ a number
of commenters noted that time savings
of the proposed fit testing protocols
would increase efficiency and be
substantial when aggregated across a
large number of employees (OSHA–
2015–0015–0018, OSHA–2015–0015–
0020). No comments indicated that the
time savings estimates would be
significantly different from those put
forth in the Preliminary Economic
Analysis (PEA).13 As a result, OSHA has
not changed its methodology for
13 As discussed in the ‘‘Summary and
Explanation,’’ several comments (OSHA–2015–
0015–0022, OSHA–2015–0015–0032, OSHA–2015–
0015–0042) expressed concern about the estimated
decrease in total ambient test time included as part
of the protocol. The ‘‘Summary and Explanation’’
explains why this test time is reasonable and
sufficient in this context. However, the comments
did not question the total estimated time savings for
the new protocols, per se.
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
calculating the potential cost savings of
implementing the new protocols.
The new quantitative fit testing
(QNFT) protocols will provide
employers additional options to fit test
their employees for respirator use.
While OSHA approves fit testing
protocols rather than fit testing
machines, OSHA understands that,
currently, the market for fit testing
machines using the original ambient
aerosol CNC protocol is dominated by
TSI’s PortaCount® machines (Models
8020, 8030, 8038, 8040, 8048).14 As
such, OSHA’s Final Economic Analysis
(FEA) focuses specifically on TSI’s
PortaCount® machines. Employers
already using the original ambient
aerosol CNC protocol with a
PortaCount® machine (with the
exception of the now-discontinued
8020) may switch from the original
ambient aerosol CNC protocol to the
new protocols. OSHA estimates
switching saves approximately 5
minutes per fit test, and grants the
employer corresponding cost savings.
According to TSI, ‘‘[e]xisting owners
of the PortaCount® Respirator Fit Tester
Pro Model 8030 and/or PortaCount®
Pro+ Model 8038 will be able to utilize
the new protocols without additional
expense. It will be necessary for fit
testers to obtain a firmware and FitPro
software upgrade, which TSI will be
providing as a free download. As an
alternative to the free download,
PortaCount® Models 8030 and 8038
returned for annual service will be
upgraded without additional charge.
Owners of the PortaCount® Plus Model
8020 with or without the N95CompanionTM Technology (both
discontinued in 2008) will be limited to
the current 8-exercise OSHA fit test
protocol’’ (OSHA–2015–0015–0010).15
There are approximately 12,000 Model
8030 or 8038 units in the field.16
Existing PortaCount® users may adopt
the new protocols with minimal effort:
The fit tester will be able to select the
new protocol after taking an estimated
less than five minutes to download
TSI’s firmware and software updates.
The individual being fit tested is also
likely to learn the new protocols with
14 TSI indicated that as of the beginning of 2018,
there were no active competitors, but that at least
one company may be entering the market later in
the year (OSHA–2015–0015–0046).
15 TSI later confirmed this information still
applied in 2018, even after the introduction of their
new models (OSHA–2015–0015–0046).
16 As indicated by TSI in 2015 (OSHA–2015–
0015–0012). As explained later on in this FEA, the
aggregate cost savings were based on estimates of
current use of the 8030 and 8038 models. As the
market is now being augmented with the 8040 and
8048 models, it is likely a conservative estimate of
the potential cost savings.
PO 00000
Frm 00041
Fmt 4700
Sfmt 4700
50751
minimal time. In fact, information about
the new protocols could be imparted
during the annual training mandated by
OSHA’s respiratory protection rule
(OSHA–2015–0015–0012). As a
practical matter, the new protocols
contain fewer exercises requiring
mastery. And Part I.A.12 of appendix A
of OSHA’s Respiratory Protection
Standard already requires the fit tester
to describe the fit test to the respirator
wearer, regardless of which fit test it is
or how often it is used. Thus, there
should be no additional burden to the
employer or employee.
OSHA anticipates many employers
who currently use the original ambient
aerosol CNC protocol will adopt the
new protocols because they could be
adopted at negligible cost to the
employer and would take less time to
administer. OSHA expects that the new
protocols are less likely to be adopted
by employers who currently perform fit
testing using other quantitative or
qualitative fit tests because of the
significant equipment and training
investment that they already have made
to administer these fit tests. For
example, OSHA estimates, based on
information from TSI, that switching
from qualitative to quantitative fit
testing would require upfront costs of
$8,700 to $12,000 per machine (OSHA–
2015–0015–0012).
OSHA has estimates of the number of
users of the PortaCount® technology at
the establishment level, both from the
manufacturer and from the 2001 NIOSH
Respirator Survey. However, what is not
known is how many respirator wearers,
that is, employees, are fit tested using a
PortaCount® device. As described in the
PEA, OSHA expects that economies of
scale will apply in this situation—larger
establishments will be more likely to
encounter situations needing QNFT, but
will also have more employees over
which to spread the capital costs. OSHA
received no comments about its
understanding of employer size in
relation to QNFT use. Once employers
have invested capital in a quantitative
fit testing device, they have more of an
incentive to perform QNFT in a given
situation, even if not technically
required to use QNFT in every situation.
Also, some QNFT devices are acquired
by third parties, or ‘‘fit testing houses,’’
that provide fit testing services to
employers. In short, as put forth in the
PEA, OSHA believes that employers
using PortaCount® QNFT will process
more respirator wearers than the average
establishment. OSHA received no
comments about this conclusion.
As set forth in the PEA, if one started
with an estimate of 12,000
establishments using PortaCount®
E:\FR\FM\26SER1.SGM
26SER1
50752
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
khammond on DSKJM1Z7X2PROD with RULES
models 8030 and 8038 annually for all
of their employees and assumed an
average of 100 respirator wearers fit
tested annually per establishment, this
yielded an estimate of 1.2 million
respirator wearers that could potentially
benefit from the new QNFT protocols.17
Alternatively, as also set out in the PEA,
a similar estimate would have been
obtained if one assumed, employing
data from the 2001 NIOSH Respirator
Survey, that 50 percent of the devices
requiring QNFT (such as full-facepiece
elastomeric negative pressure
respirators) use PortaCount® currently,
as well as 25 percent of half-mask
elastomeric respirators, and 10 percent
of filtering facepieces.18 These estimates
in the PEA were not questioned in
public comment. In the intervening
period between the PEA and the FEA,
the total number of employees and
estimated respirator wearers increased
somewhat, raising the estimated number
of respirator wearers affected by the
rulemaking, based on survey data, to
approximately 1.3 million.
If applied to approximately 1.3
million respirators wearers, an
estimated savings of 5 minutes per
respirator wearer would equal over
100,000 hours of employee time saved
annually. Consistent with Department of
Labor policy for translating the labor
time savings into dollar cost savings for
this FEA, OSHA included an overhead
rate when estimating the marginal cost
of labor in its primary cost calculation.
Overhead costs are indirect expenses
that cannot be tied to producing a
specific product or service. Common
examples include rent, utilities, and
office equipment. Unfortunately, there
is no general consensus on the cost
elements that fit this definition. The
lack of a common definition has led to
a wide range of overhead estimates.
Consequently, the treatment of overhead
costs needs to be case-specific. OSHA
17 TSI estimated the number of users of their
devices at over 12,000 establishments (OSHA–
2015–0015–0012). As indicated in the PEA, this
was consistent with data from the 2001 NIOSH
respirator survey (OSHA–2015–0015–0045), which,
if benchmarked to a 2012 count of establishments
(OSHA–2015–0015–0048) and containing fit testing
methods to include ambient aerosol, generated
aerosol, and a proportionally allocated percentage
of the ‘‘don’t know’’ respondents, would provide an
estimate of 12,458 establishments using
PortaCount® currently. Based on information from
TSI, the large majority of these are estimated to be
the newer 8030 and 8038 devices.
18 Based on the 2001 NIOSH respirator survey
(OSHA–2015–0015–0045), benchmarked to 2015
County Business Patterns (OSHA–2015–0015–
0048), OSHA estimates 1,273,616 (or approximately
1.3 million) employees will be affected by the
rulemaking. These estimates are based only on
private employers. Accounting for governmental
entities would result in an even larger number of
total estimated respirator users affected.
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
adopted an overhead rate of 17 percent
of base wages, consistent with overhead
rates used for other regulatory
compliance rules.19 For example, this is
consistent with the overhead rate used
for sensitivity analyses in the 2017
Improved Tracking FEA and the FEA in
support of OSHA’s 2016 final standard
on Occupational Exposure to Respirable
Crystalline Silica. For example, in this
case, to calculate the total labor cost for
a typical respirator wearer, based on the
mean worker wage, three components
are added together: Base wage ($23.86)
+ fringe benefits ($10.42—43.7% of
$23.86); 20 and the applicable overhead
costs ($4.06—17% of $23.86). This
results in an hourly labor cost of a
respirator wearing employee to $38.34.
This implies an estimated cost savings
of $4.1 million attributable to the
adoption of the new fit testing protocols.
Because the $4.1 million represents
annual cost savings, the final estimate is
the same when discounted at either 3 or
7 percent. For the same reason, when
the Department of Labor uses a
perpetual time horizon to allow for cost
comparisons under E.O. 13771, the
annualized cost savings of the final rule
are also $4.1 million with 7 percent
discounting. As indicated earlier, this
final estimate includes an overhead
factor in the labor costs. This is
estimated to add an additional savings
of approximately 12%, or over
$400,000, on what would have been an
estimated savings of $3.6 million.
In addition to costs related to the
respirator wearer’s time, there will also
likely be time savings for the person
administering the fit tests. However,
OSHA did not include this cost savings
element in the PEA because it lacked
specific empirical information on this
point at the time of the proposal. OSHA
requested comment on this question,
but did not receive any. While OSHA
believes this element of the cost savings
is potentially substantial, it is not a
critical element for the FEA, as it is
simply a question of how large the cost
savings are, and not required, for
example, to determine economic
feasibility. Therefore, OSHA is
19 The methodology was modeled after an
approach used by the Environmental Protection
Agency. More information on this approach can be
found at: U.S. Environmental Protection Agency,
‘‘Wage Rates for Economic Analyses of the Toxics
Release Inventory Program,’’ June 10, 2002. This
analysis itself was based on a survey of several large
chemical manufacturing plants: Heiden Associates,
Final Report: A Study of Industry Compliance Costs
Under the Final Comprehensive Assessment
Information Rule, Prepared for the Chemical
Manufacturers Association, December 14, 1989.
20 Mean wage rate of $23.86 (OSHA–2015–0015–
0043), assuming fringe benefits are 30.4 percent of
total compensation (OSHA–2015–0015–0043), or by
extension, 43.7% of base wages (1/(1–bw)).
PO 00000
Frm 00042
Fmt 4700
Sfmt 4700
maintaining in the final analysis the
same analytical approach used in the
PEA.21
In addition, as discussed, this FEA
does not account for potential
conversions from testing methods other
than the original ambient aerosol CNC
protocol. While such conversions could
further increase time and cost savings,
OSHA cannot predict the number of
conversions with confidence. In short,
while certain factors could change the
precise cost savings estimates in the
FEA, OSHA believes its estimates
reasonably capture the direction and
order of magnitude of the rulemaking’s
economic effects.
Regulatory Flexibility Certification
In accordance with the Regulatory
Flexibility Act, 5 U.S.C. 601 et seq. (as
amended), OSHA has examined the
regulatory requirements of the final rule
to determine whether these
requirements will have a significant
economic impact on a substantial
number of small entities. This rule will
impose no required costs and could
provide a cost savings in excess of $4
million per year to regulated entities.
While measureable in the aggregate,
these savings will be dispersed widely,
and therefore are not estimated to have
a substantial economic impact on any
small entity, although the impacts are
estimated to be positive. The Assistant
Secretary for Occupational Safety and
Health therefore certifies that the final
rule will not have a significant
economic impact on a substantial
number of small entities.
C. Paperwork Reduction Act
Overview
The Paperwork Reduction Act (PRA)
requires that agencies obtain approval
from OMB before conducting any
collection of information (44 U.S.C.
3507). The PRA defines ‘‘collection of
information’’ to mean ‘‘the obtaining,
causing to be obtained, soliciting, or
requiring the disclosure to third parties
or the public, of facts or opinions by or
for an agency, regardless of form or
format’’ (44 U.S.C. 3502(3)(A)).
In accordance with the PRA, 44 U.S.C.
3506(c)(2), OSHA solicited public
comments on proposed revisions to the
Respiratory Protection Standard
Information Collection Request (ICR)
(paperwork burden hour and cost
21 For example, in the PEA OSHA posited that the
time saved may potentially be as much as a 1:1 ratio
between the tester and those being tested. But, for
purposes of argument, if the ratio was only 1:4 (or
the equivalent of 1 minute 15 seconds of tester’s
time per employee tested), OSHA estimates the cost
savings related to the tester would be an additional
$1.3 million.
E:\FR\FM\26SER1.SGM
26SER1
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
khammond on DSKJM1Z7X2PROD with RULES
analysis) for the information collection
requirements associated with the
Additional PortaCount® Quantitative
Fit-Testing Protocols: Amendment to
Respiratory Protection Standard
proposed rule (81 FR 69747). The
Department submitted this ICR to OMB
for review in accordance with 44 U.S.C.
3507(d) on October 7, 2016. A copy of
the ICR for the proposed rule is
available to the public at: https://
www.reginfo.gov/public/do/
PRAViewICR?ref_nbr=201511-1218-005.
Solicitation of Comments
On November 22, 2016, OMB issued
a Notice of Action withholding its
approval of the ICR. OMB requested
that, ‘‘[p]rior to publication of the final
rule, the agency should provide a
summary of any comments related to
the information collection and their
response, including any changes made
to the ICR as a result of comments. In
addition, the agency must enter the
correct burden estimates.’’
No public comments were received
specifically in response to the proposed
ICR submitted to OMB for review.
However, several public comments
submitted in response to the NPRM,
described earlier in this preamble,
substantively addressed provisions
containing collections of information
and included information relevant to
the burden hour and costs analysis.
These comments are addressed in the
preamble, and OSHA considered them
when it developed the revised ICR
associated with this final rule. See the
comment analysis in section II.D above.
Under the PRA, a Federal agency
cannot conduct or sponsor a collection
of information unless it is approved by
OMB under the PRA, and the collection
of information notice displays a
currently valid OMB control number (44
U.S.C. 3507(a)(3)). Also,
notwithstanding any other provision of
law, no employer shall be subject to
penalty for failing to comply with a
collection of information if the
collection of information does not
display a currently valid OMB control
number (44 U.S.C. 3512). The revised
information collection requirements
found in the final rule are summarized
below.
The Department of Labor has
submitted the final ICR concurrent with
the publication of this final rule. The
ICR contains a full analysis and
description of the burden hours and
costs associated with the information
collection requirements of the final rule
to OMB for approval. A copy of the ICR
is available to the public at https://
www.reginfo.gov/public/do/
PRAViewICR?ref_nbr=201904-1218-002.
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
OSHA will publish a separate notice in
the Federal Register announcing the
results of OMB’s review. That notice
will also include a list of OMBapproved information collection
requirements and the total burden hours
and costs imposed by the final rule.
The additional protocols adopted in
this final rule revise the information
collection in a way that reduces existing
burden hours and costs. In particular,
the information collection requirement
specified in paragraph (m)(2) of OSHA’s
Respiratory Protection Standard, at 29
CFR 1910.134, states that employers
must document and maintain the
following information on quantitative fit
tests administered to employees: The
name or identification of the employee
tested; the type of fit test performed; the
specific make, model, style, and size of
respirator tested; the date of the test;
and the test results. The employer must
maintain this record until the next fit
test is administered. While the
information on the fit test record
remains the same, the time to obtain the
necessary information for the fit test
record is reduced since the additional
PortaCount® protocols will take an
employer less time to administer than
those currently approved in appendix A
of the Respiratory Protection Standard.
As a result, the total estimated burden
hours decrease by 201,640 hours, from
7,622,100 to 7,420,460 hours. This
decrease is a result of the more efficient
protocols established under the final
rule. OSHA accounts for this burden
under the Information Collection
Request, or paperwork analysis, for the
Respiratory Protection Standard (OMB
Control Number 1218–0099). Note that
OSHA cannot require compliance with
the information collection requirements
for the new information collection in
this final rule until OMB has approved
the information collection requirements.
Title of Collection: Respiratory
Protection Standard (29 CFR1910.134).
OMB Control Number: 1218–0099.
Affected Public: Private Sector—
business or other for-profits.
Total Estimated Number of
Respondents: 24,710,469.
Total Estimated Number of
Responses: 25,042,236.
Total Estimated Annual Time Burden
Hours: 7,420,460.
Total Estimated Annual Other
Burden: $316,906,665.
D. Federalism
OSHA reviewed this rulemaking
according to the Executive Order on
Federalism (E.O. 13132, 64 FR 43255,
Aug. 10, 1999), which requires that
Federal agencies, to the extent possible,
refrain from limiting state policy
PO 00000
Frm 00043
Fmt 4700
Sfmt 4700
50753
options, consult with states before
taking actions that would restrict states’
policy options and take such actions
only when clear constitutional authority
exists and the problem is of national
scope. The Executive Order provides for
preemption of state law only with the
expressed consent of Congress. Federal
agencies must limit any such
preemption to the extent possible.
Under section 18 of the Occupational
Safety and Health Act (the ‘‘Act,’’ 29
U.S.C. 651 et seq.), Congress expressly
provides that states may adopt, with
Federal approval, a plan for the
development and enforcement of
occupational safety and health
standards (29 U.S.C. 667). OSHA refers
to states that obtain Federal approval for
such a plan as ‘‘State Plan states.’’
Occupational safety and health
standards developed by State Plan states
must be at least as effective in providing
safe and healthful employment and
places of employment as the Federal
standards. Subject to these
requirements, State Plan states are free
to develop and enforce under state law
their own requirements for occupational
safety and health standards. With
respect to states that do not have OSHAapproved plans, OSHA concludes that
this standard conforms to the
preemption provisions of the Act.
Section 18 of the Act prohibits states
without approved plans from issuing
citations for violations of OSHA
standards. OSHA finds that the rule
does not expand this limitation.
Therefore, for States that do not have
approved occupational safety and health
plans, the rule will not affect the
preemption provisions of Section 18 of
the Act.
OSHA’s rulemaking to adopt
additional fit testing protocols under its
Respiratory Protection Standard at 29
CFR 1910.134 is consistent with
Executive Order 13132 because the
problems addressed by these fit testing
requirements are national in scope.
OSHA concludes that the fit testing
protocols adopted by this rulemaking
provide employers in every state with
procedures that will assist them in
protecting their employees from the
risks of exposure to atmospheric
hazards. In this regard, the rule offers
thousands of employers across the
nation an opportunity to use additional
protocols to assess respirator fit among
their employees. Therefore, the rule
provides employers in every state with
an alternative means of complying with
the fit testing requirements specified by
paragraph (f) of OSHA’s Respiratory
Protection Standard.
Section 18(c)(2) of the Act (29 U.S.C.
667(c)(2)) requires State Plan states to
E:\FR\FM\26SER1.SGM
26SER1
50754
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
adopt an OSHA standard, or to develop
and enforce an alternative that is at least
as effective as the OSHA standard.
However, the new fit testing protocols
adopted by this rulemaking provide
employers with alternatives to the
existing fit testing protocols specified in
the Respiratory Protection Standard;
therefore, the alternative is not, itself, a
mandatory standard. Accordingly, states
with OSHA-approved State Plans are
not obligated to adopt the additional fit
testing protocols adopted here.
Nevertheless, OSHA strongly
encourages them to adopt the final
provisions to provide additional
compliance options to employers in
their states.
In summary, this rulemaking
complies with Executive Order 13132.
In states without OSHA-approved State
Plans, this rulemaking limits state
policy options in the same manner as
other OSHA standards. In State Plan
states, this rulemaking does not
significantly limit state policy options.
khammond on DSKJM1Z7X2PROD with RULES
E. State Plan States
Section 18(c)(2) of the Act (29 U.S.C.
667(c)(2)) requires State Plan states to
adopt mandatory standards promulgated
by OSHA, or to develop and enforce an
alternative that is at least as effective as
the OSHA standard. However, as noted
in the previous section of this preamble,
states with OSHA-approved State Plans
are not obligated to adopt the provisions
of this final rule. Nevertheless, OSHA
strongly encourages them to adopt the
final provisions to provide compliance
options to employers in their States. In
this regard, OSHA concludes that the fit
testing protocols adopted by this
rulemaking provide employers in the
State Plan states with procedures that
protect the safety and health of
employees who use respirators against
hazardous airborne substances in their
workplace at least as well as the
quantitative fit testing protocols in
appendix A of the Respiratory
Protection Standard.
There are 28 states and U.S. territories
that have their own OSHA-approved
occupational safety and health programs
called State Plans. The following 22
State Plans cover state and local
government employers and privatesector employers: Alaska, Arizona,
California, Hawaii, Indiana, Iowa,
Kentucky, Maryland, Michigan,
Minnesota, Nevada, New Mexico, North
Carolina, Oregon, Puerto Rico, South
Carolina, Tennessee, Utah, Vermont,
Virginia, Washington, and Wyoming.
The following six State Plans cover state
and local government employers only:
Connecticut, Illinois, Maine, New
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
Jersey, New York, and the Virgin
Islands.
F. Unfunded Mandates Reform Act
OSHA reviewed this rulemaking
according to the Unfunded Mandates
Reform Act of 1995 (UMRA) (2 U.S.C.
1501–1507) and Executive Order 12875
(58 FR 58093 (1993)). As discussed
above in section III.B of this preamble
(‘‘Final Economic Analysis and
Regulatory Flexibility Certification’’),
OSHA has determined that the rule
imposes no additional costs on any
private-sector or public-sector entity.
The substantive content of the rule
applies only to employers whose
employees use respirators for protection
against airborne contaminants, and
compliance with the protocols
contained in the final rule are strictly
optional for these employers.
Accordingly, the final rule does not
require additional expenditures by
either public or private employers.
Therefore, this rulemaking is not a
significant regulatory action within the
meaning of Section 202 of the UMRA,
2 U.S.C. 1532.
As noted above under Section E
(‘‘State Plan States’’) of this preamble,
OSHA standards do not apply to state or
local governments except in states that
have voluntarily elected to adopt an
OSHA-approved State Plan.
Consequently, this final rulemaking
does not meet the definition of a
‘‘Federal intergovernmental mandate’’
(see 2 U.S.C. 658(5)). Therefore, for the
purposes of the UMRA, the Assistant
Secretary for Occupational Safety and
Health certifies that this rulemaking
does not mandate that state, local, or
tribal governments adopt new,
unfunded regulatory obligations, or
increase expenditures by the private
sector of more than $100 million in any
year.
G. Applicability of Existing Consensus
Standards
Section 6(b)(8) of the Act (29 U.S.C.
655(b)(8)) requires OSHA to explain
‘‘why a rule promulgated by the
Secretary differs substantially from an
existing national consensus standard,’’
by publishing ‘‘a statement of the
reasons why the rule as adopted will
better effectuate the purposes of the Act
than the national consensus standard.’’
The American National Standards
Institute (ANSI) developed a national
consensus standard on fit testing
protocols (‘‘Respirator Fit Testing
Methods,’’ ANSI Z88.10–2001) as an
adjunct to its national consensus
standard on respiratory protection
programs. ANSI/AIHA updated the
Z88.10 standard in 2010 (‘‘Respirator Fit
PO 00000
Frm 00044
Fmt 4700
Sfmt 4700
Testing Methods,’’ ANSI Z88.10–2010)
(OSHA–2015–0015–0007).
Paragraph 7.2 of ANSI/AIHA Z88.10–
2010 specifies the requirements for
conducting a particle-countinginstrument (e.g., PortaCount®)
quantitative fit test. The modified CNC
protocols adopted by the final rule are
variations of this national consensus
standard’s particle counting-instrument
quantitative fit test procedures: The new
protocols require the same 30-second
duration for fit testing exercises, but not
the same exercises as ANSI/AIHA.
However, Annex A2 of ANSI/AIHA
Z88.10–2010 recognizes that a
universally accepted measurement
standard for respirator fit testing does
not exist and provides specific
requirements for evaluating new fit
testing methods. OSHA has concluded
that the modified CNC protocols
submitted by TSI meet the evaluation
criteria outlined in ANSI/AIHA Z88.10–
2010, Annex A2.
H. Advisory Committee for Construction
Safety and Health (ACCSH) Review of
the Proposed Standard
The Contract Work Hours and Safety
Standards Act (Construction Safety Act)
(40 U.S.C. 3704), OSHA regulations
governing the Advisory Committee for
Construction Safety and Health
(ACCSH) (i.e., 29 CFR 1912.3), and
provisions governing OSHA rulemaking
(i.e., 29 CFR 1911.10) require OSHA to
consult with the ACCSH whenever
OSHA proposes a rule involving
construction activities. Specifically, 29
CFR 1911.10 requires that the Assistant
Secretary provide the ACCSH with ‘‘any
proposal of his own,’’ together with ‘‘all
pertinent factual information available
to him, including the results of research,
demonstrations, and experiments.’’
The addition of two quantitative fit
test protocols to appendix A of OSHA’s
Respiratory Protection Standard affects
the construction industry because it
revises the fit testing procedures used in
that industry (see 29 CFR 1926.103).
Accordingly, OSHA provided the
ACCSH members with TSI’s application
letter, supporting documents, and other
relevant information, prior to the
December 4, 2014 ACCSH meeting.
OSHA explained its proposal to add
new protocols to the ACCSH at that
meeting, and the ACCSH unanimously
approved proceeding with a proposed
rule.
List of Subjects in 29 CFR Part 1910
Fit testing, Hazardous substances,
Health, Occupational safety and health,
Respirators, Respiratory protection,
Toxic substances.
E:\FR\FM\26SER1.SGM
26SER1
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
Authority and Signature
Loren Sweatt, Acting Assistant
Secretary of Labor for Occupational
Safety and Health, U.S. Department of
Labor, authorized the preparation of this
document pursuant to Sections 4, 6, and
8 of the Occupational Safety and Health
Act of 1970 (29 U.S.C. 653, 655, 657),
29 CFR part 1911, and Secretary’s Order
1–2012 (77 FR 3912).
Signed at Washington, DC, on September
19, 2019.
Loren Sweatt,
Principal Deputy Assistant Secretary of Labor
for Occupational Safety and Health.
Amendments to the Standard
For the reasons stated in the
preamble, the agency amends 29 CFR
part 1910 as follows:
e. In newly redesignated Section C.7:
i. Revise paragraph (a) and paragraph
(b) introductory text; and
■ ii. Redesignate Table A–1 as Table A–
3; and
The revisions and additions read as
follows:
■
■
§ 1910.134
Respiratory protection.
*
*
Subpart I—[Amended]
1. Revise the authority citation for
subpart I of part 1910 to read as follows:
■
Authority: 29 U.S.C. 653, 655, 657;
Secretary of Labor’s Order No. 12–71 (36 FR
8754), 8–76 (41 FR 25059), 9–83 (48 FR
35736), 1–90 (55 FR 9033), 6–96 (62 FR 111),
3–2000 (65 FR 50017), 5–2002 (67 FR 65008),
5–2007 (72 FR 31160), 4–2010 (75 FR 55355),
or 1–2012 (77 FR 3912), as applicable, and
29 CFR part 1911.
2. Amend Part I in appendix A to
§ 1910.134 as follows:
■ a. Revise Section A.14(a) introductory
text;
■ b. In Section C.3:
■ i. Revise the introductory text; and
■ ii. Remove the terms ‘‘PortacountTM’’
and ‘‘Portacount’’ and add in their place
the term ‘‘PortaCount®’’;
■ c. Redesignate Sections C.4 and 5 of
as Sections C.6 and 7;
■ d. Add new Sections C.4 and 5; and
■
*
*
APPENDIX A to § 1910.134—FIT
TESTING PROCEDURES
(MANDATORY)
Part I. OSHA—Accepted Fit Test Protocols
A. Fit Testing Procedures—General
Requirements
*
PART 1910—[AMENDED]
*
*
*
*
*
14. Test Exercises. (a) Employers must
perform the following test exercises for all fit
testing methods prescribed in this appendix,
except for the two modified ambient aerosol
CNC quantitative fit testing protocols, the
CNP quantitative fit testing protocol, and the
CNP REDON quantitative fit testing protocol.
For the modified ambient aerosol CNC
quantitative fit testing protocols, employers
shall ensure that the test subjects (i.e.,
employees) perform the exercise procedure
specified in Part I.C.4(b) of this appendix for
full-facepiece and half-mask elastomeric
respirators, or the exercise procedure
specified in Part I.C.5(b) for filtering
facepiece respirators. Employers shall ensure
that the test subjects (i.e., employees)
perform the exercise procedure specified in
Part I.C.6(b) of this appendix for the CNP
quantitative fit testing protocol, or the
exercise procedure described in Part I.C.7(b)
of this appendix for the CNP REDON
quantitative fit testing protocol. For the
remaining fit testing methods, employers
shall ensure that the test exercises are
performed in the appropriate test
environment in the following manner:
*
*
*
*
*
C. Quantitative Fit Test (QNFT) Protocols
*
*
*
*
*
50755
3. Ambient aerosol condensation nuclei
counter (CNC) quantitative fit testing
protocol.
The ambient aerosol condensation nuclei
counter (CNC) quantitative fit testing
(PortaCount®) protocol quantitatively fit tests
respirators with the use of a probe. The
probed respirator is only used for
quantitative fit tests. A probed respirator has
a special sampling device, installed on the
respirator, that allows the probe to sample
the air from inside the mask. A probed
respirator is required for each make, style,
model, and size that the employer uses and
can be obtained from the respirator
manufacturer or distributor. The primary
CNC instrument manufacturer, TSI
Incorporated, also provides probe
attachments (TSI mask sampling adapters)
that permit fit testing in an employee’s own
respirator. A minimum fit factor pass level of
at least 100 is necessary for a half-mask
respirator (elastomeric or filtering facepiece),
and a minimum fit factor pass level of at least
500 is required for a full-facepiece
elastomeric respirator. The entire screening
and testing procedure shall be explained to
the test subject prior to the conduct of the
screening test.
*
*
*
*
*
4. Modified ambient aerosol condensation
nuclei counter (CNC) quantitative fit testing
protocol for full-facepiece and half-mask
elastomeric respirators.
(a) When administering this protocol to test
subjects, employers shall comply with the
requirements specified in Part I.C.3 of this
appendix (ambient aerosol condensation
nuclei counter (CNC) quantitative fit testing
protocol), except they shall use the test
exercises described below in paragraph (b) of
this protocol instead of the test exercises
specified in section I.C.3(a)(6) of this
appendix.
(b) Employers shall ensure that each test
subject being fit tested using this protocol
follows the exercise and duration procedures,
including the order of administration,
described in Table A–1 of this appendix.
TABLE A–1— MODIFIED AMBIENT AEROSAL CNC QUANTITATIVE FIT TESTING PROTOCOL FOR FULL FACEPIECE AND
HALF–MASK ELASTOMERIC RESPIRATORS
Exercises 1
Exercise procedure
Measurement procedure
Bending Over ...........
The test subject shall bend at the waist, as if going to touch his/her toes for 50
seconds and inhale 2 times at the bottom 2.
The test subject shall jog in place comfortably for 30 seconds ...........................
The test subject shall stand in place, slowly turning his/her head from side to
side for 30 seconds and inhale 2 times at each extreme 2.
The test subject shall stand in place, slowly moving his/her head up and down
for 39 seconds and inhale 2 times at each extreme 2.
A 20 second ambient sample, followed
by a 30 second mask sample.
A 30 second mask sample.
A 30 second mask sample.
Jogging-in-Place .......
Head Side-to-Side ....
Head Up-and-Down
A 30 second mask sample followed by
a 9 second ambient sample.
1 Exercises
khammond on DSKJM1Z7X2PROD with RULES
2 It
are listed in the order in which they are to be administered.
is optional for test subjects to take additional breaths at other times during this exercise.
5. Modified ambient aerosol condensation
nuclei counter (CNC) quantitative fit testing
protocol for filtering facepiece respirators.
(a) When administering this protocol to test
subjects, employers shall comply with the
requirements specified in Part I.C.3 of this
appendix (ambient aerosol condensation
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
nuclei counter (CNC) quantitative fit testing
protocol), except they shall use the test
exercises described below in paragraph (b) of
this protocol instead of the test exercises
specified in section I.C.3(a)(6) of this
appendix.
PO 00000
Frm 00045
Fmt 4700
Sfmt 4700
(b) Employers shall ensure that each test
subject being fit tested using this protocol
follows the exercise and duration procedures,
including the order of administration,
described in Table A–2 of this appendix.
E:\FR\FM\26SER1.SGM
26SER1
50756
Federal Register / Vol. 84, No. 187 / Thursday, September 26, 2019 / Rules and Regulations
TABLE A–2— MODIFIED AMBIENT AEROSAL CNC QUANTITATIVE FIT TESTING PROTOCOL FOR FILTERING FACEPIECE
RESPIRATORS
Exercises 1
Exercise
procedure
Measurement
procedure
Bending Over ...........
The test subject shall bend at the waist, as if going to touch his/her toes for 50
seconds and inhale 2 times at the bottom 2.
The test subject shall talk out loud slowly and loud enough so as to be heard
clearly by the test conductor for 30 seconds. He/she will either read from a
prepared text such as the Rainbow Passage, count backward from 100, or
recite a memorized poem or song.
The test subject shall stand in place, slowly turning his/her head from side to
side for 30 seconds and inhale 2 times at each extreme 2.
The test subject shall stand in place, slowly moving his/her head up and down
for 39 seconds and inhale 2 times at each extreme 2.
A 20 second ambient sample, followed
by a 30 second mask sample.
A 30 second mask sample.
Talking ......................
Head Side-to-Side ....
Head Up-and-Down
A 30 second mask sample.
A 30 second mask sample followed by
a 9 second ambient sample.
1 Exercises
2 It
*
are listed in the order in which they are to be administered.
is optional for test subjects to take additional breaths at other times during this exercise.
*
*
*
*
7. Controlled negative pressure (CNP)
REDON quantitative fit testing protocol.
(a) When administering this protocol to test
subjects, employers must comply with the
requirements specified in paragraphs (a) and
(c) of part I.C.6 of this appendix (‘‘Controlled
negative pressure (CNP) quantitative fit
testing protocol,’’) as well as use the test
exercises described below in paragraph (b) of
this protocol instead of the test exercises
specified in paragraph (b) of part I.C.6 of this
appendix.
(b) Employers must ensure that each test
subject being fit tested using this protocol
follows the exercise and measurement
procedures, including the order of
administration described in Table A–3 of this
appendix.
*
*
*
*
*
[FR Doc. 2019–20686 Filed 9–25–19; 8:45 am]
BILLING CODE 4510–26–P
DEPARTMENT OF HOMELAND
SECURITY
Coast Guard
33 CFR Part 165
I. Table of Abbreviations
[Docket Number USCG–2019–0756]
CFR Code of Federal Regulations
DHS Department of Homeland Security
FR Federal Register
NPRM Notice of proposed rulemaking
§ Section
U.S.C. United States Code
RIN 1625–AA00
Safety Zone, Wilmington River,
Savannah, GA
Coast Guard, DHS.
Temporary final rule.
AGENCY:
ACTION:
The Coast Guard is
establishing a temporary safety zone for
navigable waters on the Wilmington
River 1,000 feet on the north and south
side of the Islands Expressway Bridge in
Savannah, GA. The safety zone is
needed to protect personnel, vessels,
and the marine environment from
potential hazards created by the
placement of multiple spans for the new
Islands Expressway Bridge. Entry of
vessels or persons into this zone is
khammond on DSKJM1Z7X2PROD with RULES
SUMMARY:
VerDate Sep<11>2014
17:19 Sep 25, 2019
Jkt 247001
prohibited unless specifically
authorized by the Captain of the Port
(COTP) Savannah or a designated
representative.
DATES: This rule is effective without
actual notice from September 26, 2019
to 2:00 p.m. on October 22, 2019. For
the purposes of enforcement, actual
notice will be used from 8:00 a.m. on
September 18, 2019 through September
26, 2019.
ADDRESSES: To view documents
mentioned in this preamble as being
available in the docket, go to https://
www.regulations.gov, type USCG–2019–
0756 in the ‘‘SEARCH’’ box and click
‘‘SEARCH.’’ Click on Open Docket
Folder on the line associated with this
rule.
FOR FURTHER INFORMATION CONTACT: If
you have questions on this rule, call or
email MST1 Rachel Crowe, Marine
Safety Unit Savannah Office of
Waterways Management, Coast Guard;
telephone 912–652–4353, extension
243, or email Rachel.M.Crowe@uscg.mil.
SUPPLEMENTARY INFORMATION:
II. Background Information and
Regulatory History
The Coast Guard is issuing this
temporary rule without prior notice and
opportunity to comment pursuant to
authority under section 4(a) of the
Administrative Procedure Act (APA) (5
U.S.C. 553(b)). This provision
authorizes an agency to issue a rule
without prior notice and opportunity to
comment when the agency for good
cause finds that those procedures are
‘‘impracticable, unnecessary, or contrary
to the public interest.’’ Under 5 U.S.C.
PO 00000
Frm 00046
Fmt 4700
Sfmt 4700
553(b)(B), the Coast Guard finds that
good cause exists for not publishing a
notice of proposed rulemaking (NPRM)
with respect to this rule because doing
so would be impracticable. Immediate
action is needed to respond to the
potential safety hazards created by the
placement of multiple spans for the new
Islands Expressway Bridge. The Coast
Guard received information on August
27, 2019 regarding the operations
beginning on September 18, 2019. The
operation would begin before the
rulemaking process would be
completed. Because of the dangers
posed by the placement of multiple
spans, the safety zone is necessary to
provide for the safety of persons,
vessels, and the marine environment in
the event area.
Under 5 U.S.C. 553(d)(3), the Coast
Guard finds that good cause exists for
making this rule effective less than 30
days after publication in the Federal
Register. Delaying the effective date of
this rule would be impracticable
because immediate action is needed to
respond to the potential safety hazards
associated with the construction and
placement of multiple spans.
III. Legal Authority and Need for Rule
The Coast Guard is issuing this rule
under authority in 46 U.S.C. 70034. The
COTP Savannah has determined that
potential hazards associated with the
placement of multiple spans for the new
Islands Expressway Bridge starting
September 18, 2019, will be a safety
concern for anyone within 1,000 feet of
the north and south side of the Islands
Expressway Bridge. This rule is needed
to protect personnel, vessels, and the
marine environment in the navigable
waters within the safety zone during
bridge construction.
IV. Discussion of the Rule
This rule establishes a safety zone
from 8:00 a.m. on September 18, 2019
E:\FR\FM\26SER1.SGM
26SER1
Agencies
[Federal Register Volume 84, Number 187 (Thursday, September 26, 2019)]
[Rules and Regulations]
[Pages 50739-50756]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2019-20686]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF LABOR
Occupational Safety and Health Administration
29 CFR Part 1910
[Docket No. OSHA-2015-0015]
RIN 1218-AC94
Additional Ambient Aerosol CNC Quantitative Fit Testing
Protocols: Respiratory Protection Standard
AGENCY: Occupational Safety and Health Administration (OSHA),
Department of Labor.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: OSHA is approving two additional quantitative fit testing
protocols for inclusion in appendix A of the Respiratory Protection
Standard. These protocols are: The modified
[[Page 50740]]
ambient aerosol condensation nuclei counter (CNC) quantitative fit
testing protocol for full-facepiece and half-mask elastomeric
respirators and the modified ambient aerosol CNC quantitative fit
testing protocol for filtering facepiece respirators. The protocols
apply to employers in general industry, shipyard employment, and the
construction industry. Both protocols are abbreviated variations of the
original OSHA-approved ambient aerosol CNC quantitative fit testing
protocol (often referred to as the PortaCount[supreg] protocol), but
differ from the test by the exercise sets, exercise duration, and
sampling sequence. These protocols will serve as alternatives to the
four existing quantitative fit testing protocols already listed in
appendix A of the Respiratory Protection Standard and will maintain
safety and health protections for workers while providing additional
flexibility and reducing compliance burdens.
DATES: The final rule becomes effective on September 26, 2019.
ADDRESSES: In accordance with 28 U.S.C. 2112(a), the agency designates
Edmund Baird, Acting Associate Solicitor of Labor for Occupational
Safety and Health, Office of the Solicitor of Labor, Room S-4004, U.S.
Department of Labor, 200 Constitution Avenue NW, Washington, DC 20210,
to receive petitions for review of the final rule.
FOR FURTHER INFORMATION CONTACT: General information and press
inquiries: Frank Meilinger, Director, Office of Communications;
telephone: (202) 693-1999; email: [email protected].
Technical inquiries: Natalia Stakhiv, Directorate of Standards and
Guidance; telephone: (202) 693-2272; email: [email protected].
SUPPLEMENTARY INFORMATION:
Table of Contents
I. Background
II. Summary and Explanation of the Final Rule
III. Procedural Determinations
I. Background
Appendix A of OSHA's Respiratory Protection Standard (29 CFR
1910.134) currently contains four quantitative fit testing protocols:
Generated aerosol; ambient aerosol condensation nuclei counter (CNC);
controlled negative pressure (CNP); and controlled negative pressure
REDON. TSI Incorporated (``TSI'') proposed the ambient aerosol CNC
protocol--often called the PortaCount[supreg] protocol after the CNC
instrument manufactured by TSI--in 1987. OSHA allowed the ambient
aerosol CNC protocol for fit testing under a compliance interpretation
published in 1988. OSHA eventually incorporated that protocol into
appendix A of the Respiratory Protection Standard when it revised the
standard in 1998.
In 2006, TSI submitted two additional quantitative fit testing
protocols to OSHA for approval and inclusion in appendix A of the
Respiratory Protection Standard. These protocols were modified,
abbreviated versions of the original ambient aerosol CNC protocol
already approved by OSHA and listed in appendix A. OSHA published a
notice of proposed rulemaking (NPRM) on January 21, 2009 (74 FR 3526)
to include the two protocols in its Respiratory Protection Standard,
but later concluded that they were not sufficiently accurate or
reliable. OSHA withdrew the proposed rule without prejudice on January
27, 2010 (75 FR 4323), and invited the developers to resubmit the two
protocols after addressing the issues of concern listed in the
withdrawal notification. In 2014, TSI submitted three new quantitative
fit testing protocols for OSHA approval. These three protocols also
were modified, abbreviated versions of the original ambient aerosol CNC
protocol, but different from the two protocols TSI submitted to OSHA in
2006.
Part II of appendix A of OSHA's Respiratory Protection Standard
specifies the procedure for adding new fit testing protocols to the
standard. Under that procedure, if OSHA receives an application for a
new fit testing protocol meeting certain criteria, it must commence a
rulemaking proceeding to consider adopting the proposed protocol. These
criteria are: (1) A test report prepared by an independent government
research laboratory (e.g., Lawrence Livermore National Laboratory, Los
Alamos National Laboratory, the National Institute for Standards and
Technology) stating that the laboratory tested the protocol and found
it to be accurate and reliable; or (2) an article published in a peer-
reviewed industrial hygiene journal describing the protocol and
explaining how the test data support the protocol's accuracy and
reliability. TSI's 2014 application for approval of three new
quantitative fit testing protocols met the second criterion. OSHA
considers such proposals under the notice-and-comment rulemaking
procedures specified in Section 6(b)(7) of the Occupational Safety and
Health Act of 1970 (the ``Act'') (29 U.S.C. 655(b)(7)).
II. Summary and Explanation of the Final Rule
A. Proposed Rulemaking
In July 2014, TSI submitted an application requesting that OSHA
approve three new quantitative fit testing protocols for inclusion in
appendix A of OSHA's Respiratory Protection Standard (OSHA-2015-0015-
0003). These three protocols were modified, abbreviated versions of the
original ambient aerosol CNC protocol approved by OSHA and listed in
appendix A, but different from the ones submitted to OSHA by TSI in
2006. TSI's application included three peer-reviewed articles (``the
Richardson studies'') describing the accuracy and reliability of TSI's
proposed protocols.\1\ The application letter also included a copy of
the 2010 ANSI/AIHA (American National Standards Institute/American
Industrial Hygiene Association) Z88.10 ``Respirator Fit Testing
Methods'' standard (``the ANSI standard''), which contains ``Annex A2:
Criteria for Evaluating New Fit Test Methods'' (``the ANSI annex'')
(OSHA-2015-0015-0007). TSI also submitted two white papers: One
describing TSI's analysis of its talking exercise data and the second
describing TSI's process and rationale behind the fit test exercises
that were employed in the Richardson studies (OSHA-2015-0015-0001,
OSHA-2015-0015-0008). OSHA determined that the information submitted in
TSI's application met the criteria required for initiating a rulemaking
to determine whether OSHA should approve the new protocols and add them
to appendix A of the Respiratory Protection Standard. OSHA issued a
notice of proposed rulemaking (NPRM) on October 7, 2016, proposing to
add the new protocols and inviting public comments.
---------------------------------------------------------------------------
\1\ Richardson, A.W. et al. (2014a), ``Evaluation of a Faster
Fit Testing Method for Elastomeric Half-Mask Respirators Based on
the TSI PortaCount,'' Journal of the International Society for
Respiratory Protection 31(1): 9-22 (OSHA-2015-0015-0004);
Richardson, A.W. et al. (2013), ``Evaluation of a Faster Fit Testing
Method for Full-Facepiece Respirators Based on the TSI PortaCount,''
Journal of the International Society for Respiratory Protection
30(2): 116-128 (OSHA-2015-0015-0005); Richardson, A.W. et al.
(2014b), ``Evaluation of a Faster Fit Testing Method for Filtering
Facepiece Respirators Based on the TSI PortaCount,'' Journal of the
International Society for Respiratory Protection 31(1): 43-56 (OSHA-
2015-0015-0006).
---------------------------------------------------------------------------
The three new protocols submitted by TSI in July 2014 included one
for full-facepiece elastomeric respirators (the Fast-Full method), one
for half-mask elastomeric respirators (the Fast-Half method), and one
for filtering facepiece respirators (FFRs) (the Fast-FFR method). The
authors of the Richardson
[[Page 50741]]
studies evaluated each of the three types of respirators for method
performance separately, but the protocols for the Fast-Full and Fast-
Half methods were identical. As such, and to prevent duplicative
regulatory text, OSHA proposed to consolidate the Fast-Full and Fast-
Half methods into a single protocol for approval: The modified ambient
aerosol condensation nuclei counter (CNC) quantitative fit testing
protocol for full-facepiece and half-mask elastomeric respirators. OSHA
further proposed to approve the Fast-FFR protocol as the modified
ambient aerosol condensation nuclei counter (CNC) quantitative fit
testing protocol for filtering facepiece respirators. No commenters
objected to the consolidation and naming of the protocols during the
public comment period.
The original ambient aerosol CNC protocol consists of eight test
exercises, performed in the following order: Normal breathing, deep
breathing, turning head side-to-side, moving head up-and-down, talking,
grimace, bending over, and normal breathing again. The modified ambient
aerosol CNC protocol for full-facepiece and half-mask elastomeric
respirators differs as follows: (1) It includes only three of the eight
original test exercises (bending over, head side-to-side, and head up-
and-down); (2) it adds jogging-in-place as a new exercise; and (3) it
reduces the total test duration from 7.2 to 2.5 minutes. The modified
ambient aerosol CNC protocol for FFRs differs from the original ambient
aerosol CNC protocol as follows: (1) It includes only four of the eight
original test exercises (bending over, talking, head side-to-side, and
head up-and-down) and (2) it reduces the total test duration from 7.2
to 2.5 minutes.
The three Richardson studies (OSHA-2015-0015-0004, OSHA-2015-0015-
0005, OSHA-2015-0015-0006) compared the fit factors for the new
protocols to a reference method based on the approach specified in the
ANSI annex.\2\ This approach requires the performance evaluation study
to administer sequential paired tests using the proposed fit testing
method and reference method during the same respirator donning. The
reference method consisted of the standard OSHA exercises listed in
Section I.A.14 of appendix A of the Respiratory Protection Standard
(which are also the eight test exercises used for the original ambient
aerosol CNC protocol), minus the grimace exercise, in the same order as
described in the standard (i.e., normal breathing, deep breathing, head
side-to-side, head up-and-down, talking, bending over, normal
breathing). Each exercise was performed for 60 seconds.
---------------------------------------------------------------------------
\2\ A fit factor is a quantitative estimate of the fit of a
particular respirator to a specific individual, and typically
estimates the ratio of the concentration of a substance in ambient
air to its concentration inside the respirator when worn.
---------------------------------------------------------------------------
These protocols will serve as alternatives to the four existing
quantitative fit testing protocols already listed in appendix A of the
Respiratory Protection Standard and will maintain safety and health
protections for workers while providing additional flexibility and
reducing compliance burdens. This rule is a deregulatory action under
Executive Order 13771 (82 FR 9339 (January 30, 2017)). It has
annualized net cost savings estimated at $4.1 million. A detailed
discussion of OSHA's estimates of the rule's benefits, costs, and cost
savings is included in the Final Economic Analysis and Regulatory
Flexibility Certification section.
B. Articles Supporting New Fit Testing Protocols
TSI supported its application for adding the new protocols with the
three Richardson studies that indicate respectively that the proposed
Fast-Half, Fast-Full, and Fast-FFR methods can identify poorly fitting
respirators as well as the reference method used. Each article
described a study that compared fit test results using a reference
method specified in the ANSI annex with results using one of the
proposed methods. The following subsections detail the methodologies
and findings of the three Richardson studies.
1. Evaluation of the Fast-Half Method
a. Study Methods
The first Richardson study evaluated the Fast-Half method.\3\ The
study authors selected three models of NIOSH-approved, half-mask air-
purifying respirators--each available in three sizes--from ``leading
U.S. mask manufacturers'' equipped with P100 filters.\4\ Respirators
were probed with a flush sampling probe located between the nose and
mouth. The study included 9 female and 16 male participants.
---------------------------------------------------------------------------
\3\ Richardson, A.W. et al. (2014a), ``Evaluation of a Faster
Fit Testing Method for Elastomeric Half-Mask Respirators Based on
the TSI PortaCount,'' Journal of the International Society for
Respiratory Protection 31(1): 9-22 (OSHA-2015-0015-0004).
\4\ The authors chose not to identify the specific respirator
models ``because the intentional mis-sizing and lack of performing a
user seal check would misrepresent performance of these respirators
when used as part of a proper respiratory protection program''
(OSHA-2015-0015-0004).
---------------------------------------------------------------------------
Each test subject donned a respirator for a five-minute comfort
assessment and then performed two sets of fit test exercises, one using
the reference method and another the Fast-Half method. The study
authors randomized the order of the two sets of fit test exercises for
each test subject. The reference method consisted of the eight standard
OSHA exercises listed in Section I.A.14 of appendix A of the
Respiratory Protection Standard, minus the grimace exercise, in the
same order as required in the standard (i.e., normal breathing, deep
breathing, head side-to-side, head up-and-down, talking, bending over,
normal breathing). The study subject performed each exercise for 60
seconds.
The study authors explained that they decided to exclude the
grimace exercise because it ``is intended to break the respirator seal
to the face'' which ``potentially results in a shift of the
respirator'' (OSHA-2015-0015-0004). TSI submitted an additional
explanation as to why the grimace exercise was excluded in all three
Richardson studies (OSHA-2015-0015-0008). According to TSI, ``[l]ittle
or no support was found for the grimace exercise among respirator fit
test experts,'' and ``[t]he most common fault expressed by a number of
experienced fit testers and industry experts was that the grimace
cannot be consistently applied or even defined'' (Id.). TSI further
explained that the grimace exercise is intended to break the face seal,
which may not reseal in the same way for subsequent exercises. As a
result, the shift in the respirator caused by grimacing can potentially
confound comparisons between the fit test methods. TSI finally noted
that the fit factor from the grimace exercise (if measured) is not used
to calculate the overall fit factor result under the original ambient
aerosol CNC method.
The Fast-Half method included four exercises: Bending, jogging-in-
place, head side-to-side, and head up-and-down. Each test subject took
two breaths at each extreme of the head side-to-side and head up-and-
down exercises and at the bottom of the bend in the bending exercise.
Although not discussed in the Richardson study, TSI explained its
rationale for selecting the exercises that were later utilized in the
three Richardson studies. The exercises were identified, by TSI, as
being the most rigorous for (i.e., the best at) identifying poor
fitting respirators in two white papers TSI prepared and submitted to
OSHA (OSHA-2015-0015-0001, OSHA-2015-0015-0008). TSI reached its
conclusions and selected the exercises based on a literature review,
informal conversations with industry fit test experts, and in-house
pilot studies.
[[Page 50742]]
``Talking out loud,'' ``bending,'' and ``moving head up/down'' were
determined to be the three most critical exercises in determining the
overall fit factor for abbreviated respirator fit test methods by
Zhuang et al. (OSHA-2015-0015-0011).\5\ TSI's in-house pilot fit
testing studies supported the conclusions made by Zhuang et al.,
however, additional analysis of the TSI data by TSI uncovered an
unexpected trend within the data for the talking exercise (OSHA-2015-
0015-0001, OSHA-2015-0015-0008). TSI collected fit test data on
subjects using consecutive sets of the seven-exercise reference method
described above. TSI analyzed the frequency with which each exercise
produced the lowest fit factor. Fit test data were separated into three
groups: All fit tests, good-fitting fit tests, and poor-fitting fit
tests. A poor-fitting fit test was defined as any test where at least
one exercise failed, and a good-fitting fit test was defined as one
where no exercises failed.\6\ TSI's results showed that normal
breathing, deep breathing, and talking rarely produced the lowest fit
factor (frequency <=3 percent) for poor-fitting full-facepiece
respirators. On this basis, these three less rigorous exercises were
eliminated by TSI for both the Fast-Full and Fast-Half methods. The
bending exercise was the most rigorous exercise for poor-fitting full-
facepiece and half-mask elastomeric respirators. Talking was the
exercise among the seven exercises that most often had the lowest fit
factor for good-fitting full-facepiece and half-mask respirators in the
TSI pilot study. None of the other exercises stood out for half-mask
respirators, but TSI reasoned that there was a lack of data suggesting
that half-mask respirator fit tests should use different exercises than
full-facepiece respirators (OSHA-2015-0015-0008). TSI added jogging-in-
place for a fourth rigorous test exercise as part of the protocol that
the Richardson authors would evaluate, reasoning that jogging
``leverages the weight of the facepiece, much like bending, but on a
different axis, and also because both OSHA and ANSI currently include
jogging as an alternative exercise'' (OSHA-2015-0015-0008). Jogging-in-
place is an alternate (i.e., elective as opposed to required) exercise
in the ANSI annex. The study authors stated that jogging is
``aggressive in terms of evaluating the respirator seal'' (OSHA-2015-
0015-0004).
---------------------------------------------------------------------------
\5\ Zhuang et al. (2004) considered those exercises that had the
lowest fit factors as the most critical in determining the overall
fit factor.
\6\ Pass/fail levels were 500 for full-facepiece respirators and
100 for half-mask elastomeric respirators and FFRs.
---------------------------------------------------------------------------
The study authors conducted the experiments in a large chamber and
added sodium chloride (NaCl) aerosol to augment particle
concentrations, which they expected to range between 5,000 and 20,000
particles/cm\3\ (target = 10,000 p/cm\3\). The study authors used a
single CPC instrument, the PortaCount[supreg] Model 8030 (TSI
Incorporated, Shoreview MN), for sampling and valuation. They connected
the instrument to two equal-length sampling tubes. The first tube
sampled particle concentrations inside the facepiece, and the second
tube sampled the ambient particle concentration. The authors used TSI
software to switch between sampling lines and to record concentration
data.
During the reference method, for each exercise, the ambient
sampling tube was first purged for four seconds before an ambient
sample was taken for 5 seconds, followed by an 11-second purge of the
in-facepiece sampling tube and a 40-second in-facepiece sample. The
reference method took a total of 429 seconds (7 minutes 9 seconds) to
complete.
For the reference method, the authors calculated a fit factor for
each exercise by dividing the mean ambient concentration for that
exercise by the in-facepiece concentration taken during each exercise
(average of the five-second ambient measurements before and after the
exercise). The harmonic mean of the seven exercise fit factors equaled
the overall fit factor. During the first exercise of the Fast-Half
method (bending over), the ambient sampling tube was first purged for 4
seconds before an ambient sample was taken for five seconds; the in-
facepiece sampling tube was then purged for 11 seconds and a sample was
then taken from inside the mask for 30 seconds. No ambient sample was
taken during the next two exercises (jogging and head side-to-side)--
just one 30-second in-facepiece sample was collected for each exercise.
For the last exercise (head up-and-down), a 30-second in-facepiece
sample was taken, after which a 4-second ambient purge and 5-second
ambient sample were conducted. The Fast-Half method took a total of 149
seconds (2 minutes 29 seconds) to complete.
For the Fast-Half method, the ambient concentration was calculated
by taking the mean of two measurements--one before the first exercise
and one after the last exercise. The authors calculated fit factors for
each exercise by dividing the in-facepiece concentration taken during
that exercise by the mean ambient concentration. As with the reference
method, the harmonic mean of the four exercise fit factors represented
the overall fit factor. A minimum fit factor of 100 is required in
order to be regarded as an acceptable fit for half-mask respirators
under appendix A of the Respiratory Protection Standard.
To ensure that respirator fit was not significantly altered between
the two sets of exercises, a 5-second normal breathing fit factor
assessment was included before the first exercise set, between the two
sets of exercises and at the completion of the second exercise set. If
the ratio of the maximum to minimum of these three fit factors was
greater than 100, this experimental trial was excluded from data
analysis.
b. Richardson Study Results
The ANSI annex specifies that an exclusion zone within one
coefficient of variation for the reference method must be determined.
The exclusion zone is the range of measured fit factors around the
pass/fail fit factor of 100 that cannot be confirmed to be greater than
100 or less than 100 with adequate confidence and, therefore, should
not be included in evaluating performance. The study authors determined
the variability associated with the reference method using 48 pairs of
fit factors from 16 participants. They defined the exclusion zone as
fit factor measurements within one standard deviation of the 100 pass/
fail value. Six pairs of fit factors were omitted by the study authors
because the normal breathing fit factor ratio exceeded 100 and 5 pairs
of fit factors were omitted because they were identified as outliers (>
3 standard deviations from the mean of the remaining data points). The
exclusion zone calculated by the study authors ranged from 82 to 123
and did not include the five outliers. During review of the study
methods, OSHA felt that omitting outliers to define a variability-based
exclusion zone deviated from the usual scientific practice. Therefore,
OSHA recalculated the exclusion zone with the outlier data included in
the analysis (OSHA-2015-0015-0009). The recalculated exclusion zone was
somewhat wider, ranging from 68 to 146.
The final dataset for the ANSI Fast-Half performance evaluation
included 134 pairs of fit factors from 25 participants. The respirator
models and sizes were used in nearly equal proportion. The study
authors omitted eleven pairs of fit factors because the ratio of
maximum to minimum normal breathing fit factors was greater than 100.
They also omitted one pair due to a methodological error (sample line
[[Page 50743]]
detached from respirator during test). As such, 122 pairs were included
in the data analysis.
The study authors concluded that their statistical analysis
indicates that the Fast-Half method met the required acceptance
criteria for test sensitivity, predictive value of a pass, predictive
value of a fail, test specificity, and kappa statistic \7\ as defined
in the ANSI annex (see Table 1). The same was indicated by OSHA's
statistical analysis, utilizing the wider OSHA-recalculated exclusion
zone, which excluded an additional three pairs for a total of nine
pairs excluded and 119 pairs included in the analysis. OSHA therefore
agrees with the study authors that the Fast-Half method can identify
poorly fitting respirators at least as well as the reference method.
---------------------------------------------------------------------------
\7\ The kappa statistic is a measure of agreement between the
proposed and reference fit test methods. It compares the observed
proportion of fit tests that are concordant with the proportion
expected if the two tests were statistically independent. Kappa
values can vary from -1 to +1. Values close to +1 indicate good
agreement. ANSI/AIHA recommends kappa values >0.70.
---------------------------------------------------------------------------
2. Evaluation of Fast-Full Method
a. Study Methods
The second Richardson study evaluated the Fast-Half method.\8\ The
study authors selected three models of NIOSH-approved, full-facepiece
air-purifying respirators from ``leading U.S. mask manufacturers''
equipped with P100 filters. Each model was available in three sizes.
Respirators were probed with a non-flush sampling probe inside the nose
cup, extending 0.6 cm into the breathing zone. The study included 11
female and 16 male participants. The reference method, choice of
exercises, PortaCount[supreg] instrument, test aerosol, and sampling
sequence were identical to those used for the Fast-Half method.
Appendix A of the Respiratory Protection Standard requires a minimum
fit factor of 500 for full-facepiece respirators.
---------------------------------------------------------------------------
\8\ Richardson, A.W. et al. (2013), ``Evaluation of a Faster Fit
Testing Method for Full-Facepiece Respirators Based on the TSI
PortaCount,'' Journal of the International Society for Respiratory
Protection 30(2): 116-128 (OSHA-2015-0015-0005).
---------------------------------------------------------------------------
b. Richardson Study Results
The study authors determined the variability associated with the
reference method using 54 pairs of fit factors from 17 participants.
The exclusion zone was defined as fit factor measurements within one
standard deviation of the 500 pass/fail value. Five pairs of fit
factors were omitted because the normal breathing fit factor ratio
exceeded 100, and three pairs of fit factors were omitted because they
were identified as outliers (> 3 standard deviations from the mean of
the remaining data points). The exclusion zone calculated by the study
authors ranged from 345 to 726 and did not include the three outliers.
OSHA recalculated the exclusion zone with the outlier data included in
the analysis (OSHA-2015-0015-0009). The recalculated exclusion zone
determined by OSHA was somewhat wider ranging from 321 to 780.
The final dataset for the ANSI Fast-Full performance evaluation
included 148 pairs of fit factors from 27 participants. The respirator
models and sizes were used in nearly equal proportion. Eleven pairs
were omitted because the ratio of maximum to minimum normal breathing
fit factors was greater than 100; one pair was omitted due to an
observational anomaly (a torn piece of a cleaning wipe was observed in
the respirator during the test); 136 pairs were included in the data
analysis.
The study authors concluded that their statistical analysis
indicates that the Fast-Full method met the required acceptance
criteria for test sensitivity, predictive value of a pass, predictive
value of a fail, test specificity, and kappa statistic as defined in
the ANSI annex (see Table 1). The same was indicated by OSHA's
statistical analysis, utilizing the wider OSHA-recalculated exclusion
zone, which excluded an additional three pairs for a total of 15 pairs
excluded and 133 pairs included in the analysis. OSHA therefore agrees
with the study authors that the Fast-Full method can identify poorly
fitting respirators at least as well as the reference method.
3. Evaluation of Fast-FFR (Filtering Facepiece Respirator) Method
a. Study Methods
The third Richardson article evaluated the Fast-FFR method.\9\ Ten
models of NIOSH-approved N95 FFRs from six ``leading U.S. mask
manufacturers'' were selected for study.\10\ The different models were
selected to represent a range of styles: six cup-shaped, two horizontal
flat-fold, and two vertical flat-fold models. No information was
provided in the publication about whether models were available in
different sizes. However, at OSHA's request, TSI submitted the
following additional information regarding the choice of respirators
(OSHA-2015-0015-0010):
---------------------------------------------------------------------------
\9\ Richardson, A.W. et al. (2014b), ``Evaluation of a Faster
Fit Testing Method for Filtering Facepiece Respirators Based on the
TSI PortaCount,'' Journal of the International Society for
Respiratory Protection 31(1): 43-56 (OSHA-2015-0015-0006).
\10\ The authors chose not to identify the specific respirator
models ``because the intentional mis-sizing and lack of performing a
user seal check would misrepresent performance of these respirators
when used as part of a proper respiratory protection program''
(OSHA-2015-0015-0006).
The study plan for FFR called for 10 N95 FFR. Unlike elastomeric
respirators, FFR designs vary widely and are typically not offered
in different sizes. The authors felt it was important to use a
variety of designs that represent the styles currently available in
the US. Of the 10 models used, 6 were cup-shaped, 2 were vertical-
fold, and 2 were horizontal-fold designs. The cup-shaped style is by
far the most common, which is why 6 of the 10 model selected have
that fundamental design. Four flat-fold designs (2 vertical-fold and
---------------------------------------------------------------------------
2 horizontal-fold) models are also included.
Respirators were probed with a flush sampling probe located between
the nose and mouth. Lightweight sample tubing and neck straps were used
to ensure the tubing did not interfere with respirator fit. Twenty-nine
participants (11 female; 18 male) were included in the study. The
reference method, test aerosol, and most other study procedures were
analogous to those used for the Fast-Half and Fast-Full methods.
However, the Fast-FFR method employed these four exercises: Bending,
talking, head side-to-side, and head up-and-down with the same sampling
sequence and durations as the other test protocols. The talking
exercise replaces the jogging exercise used in the Fast-Half and Fast-
Full methods. TSI decided not to eliminate the talking exercise for
FFRs even though their pilot study indicated that it rarely produces
the lowest fit factor (OSHA-2015-0015-0008). They felt from their own
experience that jogging does not represent the kind of motions that FFR
wearers do when using the respirator (OSHA-2015-0015-0008). TSI also
indicated that the sampling probe configured on lightweight FFR
respirators caused the respirator to pull down and away from the face
during jogging creating unintentional leakage. A PortaCount[supreg]
Model 8038 operated in the N95 mode (TSI Inc., Shoreview MN) was used
to measure aerosol concentrations throughout the experiments. The
particle concentrations in the test chamber were expected to be greater
than 400 p/cm\3\. A minimum fit factor of 100 is required in order to
be regarded as an acceptable fit for these types of respirators under
appendix A of the Respiratory Protection Standard.
b. Richardson Study Results
The study administered sequential paired fit tests using the Fast-
FFR
[[Page 50744]]
method and a reference method according to the ANSI annex. The study
authors randomized the order of the two sets of fit test exercises for
each test subject. The study authors determined the variability
associated with the reference method using 63 pairs of fit factors from
14 participants. They defined the exclusion zone as fit factor
measurements within one standard deviation of the 100 pass/fail value.
Two pairs of fit factors were omitted by the study authors because the
normal breathing fit factor ratio exceeded 100, and six pairs of fit
factors were omitted because they were identified as outliers (>3
standard deviations from the mean of the remaining data points). The
exclusion zone calculated by the study authors ranged from 78 to 128
and did not include the six outliers. OSHA recalculated the exclusion
zone with the outlier data included in the analysis (OSHA-2015-0015-
0009). The recalculated exclusion zone was somewhat wider, ranging from
69 to 144.
The final dataset for the ANSI Fast-FFR performance evaluation
included 114 pairs of fit factors from 29 participants. The respirator
models were used in nearly equal proportion. The authors omitted two
pairs because the ratio of maximum to minimum normal breathing fit
factors was greater than 100, leaving 112 pairs for the data analysis.
The study authors concluded that their statistical analysis
indicates that the Fast-FFR method met the required acceptance criteria
for test sensitivity, predictive value of a pass, predictive value of a
fail, test specificity, and kappa statistic as defined in the ANSI
annex (see Table 1). The same was found by OSHA's statistical analysis,
utilizing the wider OSHA-recalculated exclusion zone, which excluded an
additional four pairs for a total of 11 pairs excluded and a 102 pairs
included in the analysis. OSHA therefore agrees with the study that the
Fast-FFR method can identify poorly fitting respirators at least as
well as the reference method.
Table 1--Comparison of Fit Test Protocols With ANSI Criteria
----------------------------------------------------------------------------------------------------------------
ANSI Z88.10 Fast-full Fast-half Fast-FFR
----------------------------------------------------------------------------------------------------------------
Sensitivity..................................... >=0.959 0.98 0.96 1.00
PV Pass......................................... >=0.95 0.98 0.97 1.00
Specificity..................................... >=0.50 0.98 0.97 0.85
PV Fail......................................... >=0.50 0.98 0.93 0.93
Kappa........................................... >=0.70 0.97 \1\ 0.89 \1\ 0.89
----------------------------------------------------------------------------------------------------------------
\1\ The kappa values in the table are those determined using the OSHA recalculated exclusion zone. The kappa
values reported by the study authors using a narrower exclusion zone were 0.90 and 0.87, respectively, for the
Fast-Half and Fast-FFR methods.
Other statistical values were the same for both OSHA and study author exclusion zone determinations.
C. Consensus Standards
While appendix A of OSHA's Respiratory Protection Standard
specifies the procedure for adding new fit testing protocols to the
standard, it does not specify any particular method(s) or criteria for
evaluating a new fit test. Section 6(a) of the Act directs the
Secretary of Labor to promulgate by rule ``as an occupational safety or
health standard any national consensus standard . . . unless he
determines that the promulgation of such a standard would not result in
improved safety or health for specifically designated employees.'' 29
U.S.C. 655(a). Section 6(b)(8) of the Act further states: ``Whenever a
rule promulgated by the Secretary differs substantially from an
existing national consensus standard, the Secretary shall, at the same
time, publish in the Federal Register a statement of the reasons why
the rule as adopted will better effectuate the purposes of this Act
than the national consensus standard.'' 29 U.S.C. 655(b)(8). And OSHA
has a long history of considering national safety and health consensus
standards, such as ANSI and NFPA (National Fire Protection
Association), in developing its own standards.
The National Technology Transfer and Advancement Act of 1995
similarly endorses agencies' use of national consensus standards: ``all
Federal agencies and departments shall use technical standards that are
developed or adopted by voluntary consensus standards bodies, using
such technical standards as a means to carry out policy objectives or
activities determined by the agencies and departments.'' Public Law
104-113, section 12(d), 110 Stat. 775, 783 (1996), 15 U.S.C. 272 note.
ANSI/AIHA is such a voluntary consensus standards body, whose
standards, including Z88.10, are widely recognized and accepted by the
industrial hygiene community. OSHA concurs with ANSI that ``this annex
[A2] provides a specific procedure for evaluating fit test methods
against the current body of knowledge.'' OSHA therefore considers the
annex's procedure to be a valid, acceptable method for evaluating new
fit test protocols (ANSI/AIHA, 2010).
D. Comments to the Proposal
In the October 2016 NPRM, OSHA preliminarily determined that the
new protocols met the sensitivity, specificity, predictive value, and
other criteria outlined in the ANSI annex and would, therefore, provide
employees with at least as much protection as the reference method.
That reference method consisted of the standard OSHA exercises listed
in Section I.A.14 of appendix A of the Respiratory Protection Standard
(which are the eight test exercises used for the original ambient
aerosol CNC protocol), minus the grimace exercise, in the same order as
described in the standard (i.e., normal breathing, deep breathing, head
side-to-side, head up-and-down, talking, bending over, normal
breathing). OSHA further concluded that it was reasonable to remove the
grimace exercise from the reference method during the method comparison
testing, because its inclusion would unpredictably impact respirator
fit (see Question #10 below for a more detailed discussion). After
having considered the comments submitted in response to the NPRM
(discussed below), OSHA has concluded that it is appropriate to amend
appendix A of the Respiratory Protection standard to include the
proposed fit test protocols.
In the NPRM, OSHA invited public comment on the accuracy and
reliability of the proposed protocols, their effectiveness in detecting
respirator leakage, and their usefulness in selecting respirators that
will protect employees from airborne contaminants in the workplace.
OSHA invited public comment on the following specific questions:
1. Were the three studies described in the peer-reviewed journal
articles well controlled and conducted according to
[[Page 50745]]
accepted experimental design practices and principles?
2. Were the results of the three studies described in the peer-
reviewed journal articles properly, fully, and fairly presented and
interpreted?
3. Did the three studies treat outliers appropriately in
determination of the exclusion zone?
4. Will the two proposed protocols generate reproducible fit
testing results?
5. Will the two proposed protocols reliably identify respirators
with unacceptable fit as effectively as the quantitative fit testing
protocols, including the OSHA-approved standard PortaCount[supreg]
protocol, already listed in appendix A of the Respiratory Protection
Standard?
6. Did the protocols in the three studies meet the sensitivity,
specificity, predictive value, and other criteria contained in the
ANSI/AIHA Z88.10-2010, Annex A2, Criteria for Evaluating Fit Test
Methods?
7. Are the specific respirators selected in the three studies
described in the peer-reviewed journal articles representative of the
respirators used in the United States?
8. Does the elimination of certain fit test exercises (e.g., normal
breathing, deep breathing, talking) required by the existing OSHA-
approved standard PortaCount[supreg] protocol impact the acceptability
of the proposed protocols?
9. Is the test exercise, jogging-in-place, that has been added to
the Fast-Full and Fast-Half protocols appropriately selected and
adequately explained? Should the jogging exercise also be employed for
the Fast-FFR protocol? Is the reasoning for not replacing the talking
exercise with the more rigorous jogging exercise in the Fast-FFR
protocol (as was done in Fast-Full and Fast-Half) adequately explained?
10. Was it acceptable to omit the grimace from the reference method
employed in the studies evaluating performance of the proposed fit
testing protocols? Is it appropriate to exclude the grimace completely
from the proposed protocols, given that it is not used in the
calculation of the fit factor result specified under the existing or
proposed test methods? If not, what other criteria could be used to
assess its inclusion or exclusion?
11. The protocols in the three studies specify that participants
take two deep breaths at the extreme of the head side-to-side and head
up-and-down exercises and at the bottom of the bend in the bend-forward
exercise. According to the developers of these protocols, the deep
breaths are included to make the exercises more rigorous and
reproducible from one subject to the next. Are these additional
breathing instructions adequately explained in the studies and in the
proposed amendment to the standard? Are they reasonable and
appropriate?
12. Does OSHA's proposed regulatory text for the two new protocols
offer clear instructions for implementing the protocols accurately?
OSHA received 27 comments from 25 separate individuals, with one
individual submitting three separate comments (OSHA-2015-0015-0015 to
OSHA-2015-0015-0042). In addition, TSI submitted a comment several
months after the close of the comment period (OSHA-2015-0015-0047).
OSHA added TSI's comment to the docket as a late submission in the
interest of full disclosure but did not take it into account.
Of the 27 timely comments, six did not specifically address any of
OSHA's specific questions, but were generally in favor of the proposed
protocols (OSHA-2015-0015-0016, OSHA-2015-0015-0018, OSHA-2015-0015-
0019, OSHA-2015-0015-0020, OSHA-2015-0015-0030, OSHA-2015-0015-0039).
Among other things, these comments agreed that the abbreviated
protocols would save time and resources and would increase employer
compliance with safety and health regulations.
OSHA addresses below the comments that addressed the NPRM's
specific questions:
1. Were the three studies described in the peer-reviewed journal
articles well controlled and conducted according to accepted
experimental design practices and principles?
The majority of concerned comments about the proposed protocols
related to the experimental design and methods used in the three
Richardson studies supporting the proposed protocols. The most common
of these criticisms was that the testing was not representative of
``real world'' settings (OSHA-2015-0015-0022, OSHA-2015-0015-0025,
OSHA-2015-0015-0026, OSHA-2015-0015-0027, OSHA-2015-0015-0032, OSHA-
2015-0015-0033, OSHA-2015-0015-0040, OSHA-2015-0015-0041, OSHA-2015-
0015-0042). For example, one commenter asserted that the environment of
the test chambers used in the three Richardson studies was ``too
controlled'' and that the studies ``did not allow for variables
encountered by fit test providers when conducting fit testing in real
world settings'' (OSHA-2015-0015-0026). Another commenter stated: ``In
an uncontrolled environment many factors, including but not limited to,
ventilation, doors being opened, and room temperature can greatly
affect the particle count in a relatively short time'' (OSHA-2015-0015-
0040).
Regarding these comments, OSHA would like to stress that the
proposed protocols were evaluated using the criteria outlined in Annex
A2 of the ANSI/AIHA Z88.10-2010 standard, which does not require
uncontrolled testing conditions with variables such as fluctuating
climate, temperature, elevation, air currents, ventilation, etc. OSHA
considers the ANSI annex method to be a valid method for evaluating new
fit test protocols.
Many of these comments related specifically to the use of generated
aerosols in the three Richardson studies (OSHA-2015-0015-0022, OSHA-
2015-0015-0026, OSHA-2015-0015-0033, OSHA-2015-0015-0041). For example,
one commenter stated:
The PortaCount[supreg] was designed and marketed to be used for
conducting quantitative fit tests using room aerosols, whereas the
supporting studies were conducted in a test chamber using a
generated aerosol. Concentrations of room aerosols are typically
about 1x10\3\ p/cc, whereas in these studies the average challenge
concentrations were about 2x10\4\ p/cc. . . . I would recommend that
the protocols not be accepted until these validation tests are
conducted using ambient aerosols. . . . (OSHA-2015-0015-0033).
Another commenter questioned why the study authors used generated
aerosol in a test chamber when their goal was to prove the
acceptability of a new ambient aerosol test protocol (OSHA-2015-0015-
0041).
None of the three Richardson studies, however, employed a
``generated aerosol'' atmosphere as described in the ANSI/AIHA Z88.10
standard; instead, they used ``the ambient laboratory aerosol which was
augmented by NaCl particles from a TSI Model 8026 Particle Generator''
(OSHA-2015-0015-0004, OSHA-2015-0015-0005, OSHA-2015-0015-0006). This
approach is allowed by ANSI/AIHA in Annex A2, which states that ``a
proposed modification to an accepted QNFT [quantitative fit testing]
protocol can be evaluated using the accepted protocol for that
instrument as the reference standard.'' As some commenters noted (OSHA-
2015-0015-0031, OSHA-2015-0015-0041), it is often necessary to augment
the ambient environment when using the original OSHA-approved ambient
aerosol CNC fit test method in a relatively clean office environment.
The TSI particle generator is one of several approaches commonly used
(OSHA-2015-0015-0051, OSHA-2015-0015-0050). In fact, as noted by one
commenter, technicians sometimes burn candles or incense in order to
reach and
[[Page 50746]]
maintain ambient particle counts (OSHA-2015-0015-0032). OSHA has
concluded that there is no material difference between the experimental
atmosphere employed in the three Richardson studies and the atmosphere
commonly used for quantitative fit testing with the ambient aerosol CNC
method.
Other commenters expressed concerns that the ambient and purge
times were too short (OSHA-2015-0015-0022, OSHA-2015-0015-0026, OSHA-
2015-0015-0027, OSHA-2015-0015-0032, OSHA-2015-0015-0033, OSHA-2015-
0015-0036, OSHA-2015-0015-0038, OSHA-2015-0015-0041, OSHA-2015-0015-
0042). For example, one commenter recommended that the proposed
protocols ``should provide for suitable ambient and respirator purge
durations to address the full range of particle concentrations that the
device is recommended for use in instead of selecting a duration based
on the optimum conditions that were selected for the studies. . . .''
(OSHA-2015-0015-0026). Several commenters were also concerned that each
ambient sample conducted at the beginning and end of the new protocols
lasted only five seconds (OSHA-2015-0015-0032, OSHA-2015-0015-0036,
OSHA-2015-0015-0042).
Regarding these comments, OSHA notes that for every exercise
(except the grimace), the original OSHA-approved ambient aerosol CNC
protocol involves a 4-second ambient purge, a 5-second ambient sample,
and an 11-second mask purge, followed by a 40-second mask sample. A
final 4-second ambient purge and 5-second ambient sample occur after
the last 40-second exercise (normal breathing) mask sample. The
proposed protocols employ the same 4-second ambient purge, 5-second
ambient sample, and 11-second mask purge, followed by 4 consecutive 30-
second mask samples during each of the 4 exercises, and a final 4-
second ambient purge and 5-second ambient sample. The ambient purge and
sample times are the same. The new protocols differ from the original
OSHA-approved sampling protocol in these ways: The ambient environment
is measured only at the beginning and end of the exercises and not
between each exercise, mask purging occurs just once (after the first
ambient sample), and mask sampling time is 30 seconds rather than 40
seconds. Additionally, requirements for conducting the fit test in an
environment with an adequate particle concentration also did not
change; they have been standard practice for the ambient aerosol CNC
fit test method since its inception and approval by OSHA.
Regarding ambient measurements, the only difference between the new
protocols and the original OSHA-approved protocol is that the new
protocols take measurements at the beginning and end of the exercises,
while the original protocol does so between each exercise. Because the
total duration of the new protocols is much shorter than the original--
2.5 minutes versus 7.2 minutes--OSHA has concluded that there is no
need to take periodic samples between exercises. In particular, the
time between the two ambient samples in the proposed protocol is 2
minutes 15 seconds, compared to 55 seconds between each ambient sample
in the original protocol. This minor difference is unlikely to
introduce any significant errors if fit testers follow standard
practice: (1) Ensure the aerosol concentration falls between 1,000 and
30,000 particles/cm\3\ (p/cm\3\) for filters with a NIOSH designation
of N/R/P-99 or 100, and 30 to 1,500 p/cm\3\ for filters with a N/R/P-95
designation; and (2) do not augment the ambient environment if the
concentration exceeds 8000 p/cm\3\ or 800 p/cm\3\ for the 99/100 or the
95 filters, respectively (OSHA-2015-0015-0049).
Two commenters expressed concern over eliminating purging between
exercises altogether (OSHA-2015-0015-0022, OSHA-2015-0015-0038). But
there is no reason for purging between the different exercises in the
proposed protocol because the instrument continues to sample from the
same environment (inside the facepiece) throughout the exercises.
Particles measured during the first few seconds of transition from one
exercise to the next will have almost no influence on the average
concentration over a 30-second exercise sampling period.
Purging ensures that the sensing volume evaluates particles from
the correct environment and is only necessary when switching between
ambient and mask samples or vice versa. The proposed protocols do not
switch between ambient and mask sampling during the exercises, so
purging is not required.
Some commenters requested further review of the methodology of the
three Richardson studies or further validation testing by a ``third
party'' (OSHA-2015-0015-0029, OSHA-2015-0015-0040). OSHA notes that the
studies were conducted by a third party, Battelle Memorial Institute,
and the study methods were approved by Battelle's Institutional Review
Board. In addition, NIOSH stated that their ``review determined that
the three methods met the criteria contained in the ANSI/AIHA Z88.10-
2010, Annex A2'' (OSHA-2015-0015-0031). And one commenter who had some
concerns about the proposed protocols conceded that the ``referenced
peer-reviewed articles in J. of Respiratory Protection appear to meet
the mathematical and statistical criteria we expect'' (OSHA-2015-0015-
0024). Finally, the publication of the three Richardson studies in a
peer-reviewed industrial hygiene journal suggests they were well-
controlled and conducted according to accepted experimental design
practices and principles. In summary, OSHA determined that the public
comments did not identify any significant shortcomings in the
experimental design and methodology used in the three studies.
2. Were the results of the three studies described in the peer-
reviewed journal articles properly, fully, and fairly presented and
interpreted?
Although critical of the fact that the studies were conducted in a
test chamber as opposed to a real world setting, one commenter stated
``that under the specific set of conditions that the tests were
performed that they were presented well'' (OSHA-2015-0015-0026). But
another commenter expressed that it was ``impossible to determine if
the articles were properly, fully, and fairly presented and
interpreted'' because the articles did not provide data tables listing
``respirator make, model, style, size, individuals tested, and the
paired results of the new test and the reference test'' as outlined in
the ANSI annex (OSHA-2015-0015-0038). The annex recommends--but does
not require--such tables, and it is often difficult to publish a peer-
reviewed article containing a complete dataset. Regardless, OSHA
reviewed the full datasets provided by TSI as part of the review of the
study protocols, and no commenters asked to see the datasets. In
summary, OSHA finds that the public comments did not identify any
significant shortcomings in the way that the results of the three
journal articles were presented or interpreted.
3. Did the three studies treat outliers appropriately in
determination of the exclusion zone?
While OSHA disagreed with the studies' omissions of outliers in
calculating exclusion zones, OSHA recalculated exclusion zones with the
outlier data included, and the results of the re-analysis did not
change any of the studies' conclusions. In addition, NIOSH considered
the study authors' identification of outliers to be ``a reasonable
method for diagnosing/identifying outliers'' (OSHA-2015-
[[Page 50747]]
0015-0031). Finally, no commenters expressed concern about the
treatment of outliers. OSHA concludes that the treatment of outliers in
the studies did not undermine any of the studies' results or
conclusions.
4. Will the two proposed protocols generate reproducible fit
testing results?
Some commenters questioned the reproducibility of fit testing
results using the two proposed protocols (OSHA-2015-0015-0022, OSHA-
2015-0015-0042), but did not offer any compelling data or research
suggesting their non-reproducibility. One of these commenters had
concerns based on NIOSH's recommendation that OSHA (OSHA-2015-0015-
0042) conduct additional research to gather evidence for a more
informed decision. The commenter stated:
With this recommendation OSHA should not accept a protocol that
still needs further evidence to show it will produce reproducible
fit testing results. There are too many respirators and employees in
hazardous conditions to allow a protocol to move forward that isn't
fully vetted and accurate (OSHA-2015-0015-0042).
OSHA believes this commenter took NIOSH's comment out of context. The
NIOSH response to this question--in its entirety--is the following:
The studies used the OSHA-accepted ambient aerosol condensation
nuclei counter (CNC) quantitative fit testing protocol as the
reference method. This method has been shown to produce reproducible
fit testing results [Zhuang et al. 1998; Coffey et al. 2002]. Using
the procedures and requirements of ANSI Z88.10-2010, the abbreviated
methods provided results comparable to the reference method.
Therefore, the proposed protocols are anticipated to generate
reproducible results. NIOSH recommends that additional research be
conducted to provide evidence for a more informed decision (OSHA-
2015-0015-0031).
While additional research is always valuable, OSHA agrees with
NIOSH that the proposed protocols are anticipated to generate
reproducible results. The proposed protocols were evaluated based on
the approach specified in the ANSI annex, which provides a specific
procedure for evaluating fit test methods ``against the current body of
knowledge'' and is considered a valid method by much of the industrial
hygiene community. Having met the criteria of the ANSI annex, OSHA
concludes that the proposed protocols will generate reproducible fit
testing results.
5. Will the two proposed protocols reliably identify respirators
with unacceptable fit as effectively as the quantitative fit testing
protocols, including the OSHA-approved standard PortaCount[supreg]
protocol, already listed in appendix A of the Respiratory Protection
Standard?
Several commenters questioned not only the acceptability of the
proposed protocols, but also the validity of the original ambient
aerosol particle counting quantitative method already accepted by OSHA
and listed in appendix A (OSHA-2015-0015-0022, OSHA-2015-0015-0026,
OSHA-2015-0015-0027, OSHA-2015-0015-0029). Some of these commenters
were also of the opinion that the CNP-based fit testing methods are
superior to other quantitative fit testing methods. One commenter
(OSHA-2015-0015-0042) stated that the following NIOSH ``statement
raises major concerns to the ability & proven accuracy of this proposed
protocol to identify respirators with unacceptable fit'':
Evidence is not available in the literature to assess whether
the two proposed protocols reliably identify respirators with
unacceptable fit as effectively as the other accepted quantitative
fit testing protocols (generated aerosol and controlled negative
pressure (CNP)). It is recommended that further side-by-side studies
be conducted to test the equivalency of the new PortaCount Fast-Fit
methods in identifying poorly fitting respirators as effectively as
the OSHA-accepted CNP testing; potentially, tests using other
``generated aerosols'' would be needed to determine whether the
methods are equivalent (OSHA-2015-0015-0031).
Although NIOSH recommended future research, it nonetheless recommended
that OSHA accept the proposed protocols. In its review of the three
Richardson studies, NIOSH also determined that the proposed protocols
conform to the requirements of the ANSI annex.
The validity of the original OSHA-approved ambient aerosol CNC fit
testing protocol was never under question in this rulemaking. Appendix
A of OSHA's Respiratory Protection Standard states that quantitative
fit testing using ambient aerosol as the test agent and appropriate
instrumentation (condensation nuclei counter) to quantify the
respirator fit has ``been demonstrated to be acceptable.'' In addition,
the members of the ANSI/AIHA Z88.10 ``Respirator Fit Testing Methods''
committee, who represent many of the nation's leading respiratory
protection experts, opted to retain, rather than reject, this method as
an acceptable quantitative fit testing method when they updated the
national consensus standard in 2010. Furthermore, the proposed
protocols were evaluated using the method described in the ANSI annex,
which does not require a statistical comparison against the CNP method
(OSHA-2015-0015-0007). Likewise, OSHA's Respiratory Protection Standard
does not require that a new fit testing protocol be compared to the CNP
method, or any other specific fit testing method. Moreover, just as
OSHA does not rank specific makes and models of respirators, OSHA also
does not rank fit testing methods. Each fit testing method has its own
advantages and disadvantages.
In summary, OSHA determined that the new protocols met the
sensitivity, specificity, predictive value, and other criteria outlined
in the ANSI annex and will, therefore, provide employees with
protections comparable to protections afforded to them by the reference
method, which consisted of the standard OSHA exercises listed in
Section I.A.14 of appendix A of the Respiratory Protection Standard,
minus the grimace exercise, in the same order as described in the
standard (i.e., normal breathing, deep breathing, head side-to-side,
head up-and-down, talking, bending over, normal breathing). These are
the same test exercises, minus the grimace, that are utilized for both
the CNC and CNP protocols. OSHA concluded that it was reasonable to
remove the grimace exercise from the reference method during the method
comparison testing, because its inclusion would unpredictably impact
respirator fit within each pair of data comparing the current and new
fit test protocols (see Question #10 below for a more detailed
discussion).
6. Did the protocols in the three studies meet the sensitivity,
specificity, predictive value, and other criteria contained in the
ANSI/AIHA Z88.10-2010, Annex A2, Criteria for Evaluating Fit Test
Methods?
One commenter stated that evaluating the sensitivity of the new
protocols ``presents a quandary because the sensitivity of the standard
PortaCount protocol has itself not been established'' (OSHA-2015-0015-
0022). As discussed under question #5, the validity of the original
OSHA-approved ambient aerosol CNC fit testing protocol is not at issue
in this rulemaking.
OSHA's evaluation of the proposed protocols determined that they
met the criteria outlined in the ANSI annex (see sections A-B above).
In addition, NIOSH stated that their ``review determined that the three
methods met the criteria contained in the ANSI/AIHA Z88.10-2010, Annex
A2'' (OSHA-2015-0015-0031). Another commenter agreed that ``the
submitted request has followed the defined procedures and the results
fit within the statistical limits set forth in ANSI Z88.10-2010''
(OSHA-2015-0015-0035). Furthermore, OSHA
[[Page 50748]]
determined that the public comments did not provide any substantive
data or information suggesting that the proposed protocols in the three
studies did not meet the sensitivity, specificity, predictive value,
and other criteria contained in the ANSI annex.
7. Are the specific respirators selected in the three studies
described in the peer-reviewed journal articles representative of the
respirators used in the United States?
One commenter questioned the ``very small sample of the wide range
of tight sealing respirators that were used in the [studies]'' (OSHA-
2015-0015-0029), and another expressed that ``the small sample size of
respirators chosen for testing lends itself to being less than ideal''
(OSHA-2015-0015-0040). However, neither commenter provided specific
recommendations or statistical data regarding the numbers and types of
respirators that should have been selected or why. Further, the
industrial hygiene research community does not require a specified
sample size of respirators to assess fit testing protocols. Finally,
had the respirator sample size been too small to produce reliable
results, the studies likely would not have been accepted for
publication in a peer-reviewed journal.
One commenter questioned why the Richardson studies included only
filtering facepiece respirators without exhalation valves, noting that
many users opt to wear filtering facepiece respirators with exhalation
valves for comfort reasons (OSHA-2015-0015-0026). But an exhalation
valve does not affect respirator fit. While the study authors did not
explain how they selected the respirator models and designs, OSHA has
determined that the public comments did not identify any significant
shortcomings in respirator selection and believes that the models and
designs selected for the three experiments were appropriately
representative.
8. Does the elimination of certain fit test exercises (e.g., normal
breathing, deep breathing, talking) required by the existing OSHA-
approved standard PortaCount[supreg] protocol impact the acceptability
of the proposed protocols?
Several commenters expressed concern over removing certain fit test
exercises (OSHA-2015-0015-0021, OSHA-2015-0015-0024, OSHA-2015-0015-
0025, OSHA-2015-0015-0029, OSHA-2015-0015-0032, OSHA-2015-0015-0033,
OSHA-2015-0015-0038, OSHA-2015-0015-0041), but did not provide any
peer-reviewed data or published research to support their opinions.
Three commenters (OSHA-2015-0015-0021, OSHA-2015-0015-0025, OSHA-2015-
0015-0032) expressed concern about removing the talking exercise,
because they had experienced fit test failures during the talking
exercise when fit testing workers. Another commenter felt that ``it
doesn't make sense to eliminate [the talking] exercise simply because
it wasn't the worst contributing exercise with poor fitting
respirators'' (OSHA-2015-0015-0033). A third suggested retaining the
head side-to-side, head up-and-down, and talking exercises because he
believes they are currently the most rigorous exercises (OSHA-2015-
0015-0024).
Another commenter suggested that ``the conclusion to eliminate
Normal Breathing 2 (NB2) from the Fast Full Protocol is extremely
subjective'' and questioned how ``NB2 [normal breathing #2] could be
eliminated and UD [moving head up and down] kept if there is no
correlation with the study data?'' (OSHA-2015-0015-0038). This
commenter suggested increasing the purge time to improve the ability of
the NB2 exercise to detect poor fits. Regarding this question, OSHA has
concluded that TSI properly excluded the second normal breathing
exercise. In TSI's study of the Fast-Full method, the second normal
breathing exercise had the lowest fit factor 19% of the time for poor-
fitting respirators. While this score normally indicates an exercise
was effective at detecting poor-fitting respirators, TSI concluded that
score was anomalous because the corresponding score for the first
normal breathing (NB1) exercise was 0%. TSI reasoned the 19% score was
a result of particles introduced into the facepiece during the
preceding (bending over) exercise that were not purged (OSHA-2015-0015-
0008). Increasing the purge time to clear such particles would not, as
the commenter suggests, improve the ability of the NB2 exercise to
detect poor fits. Instead, NB2 would likely be as ineffective as NB1,
which was never the lowest fit factor for any poor-fitting respirators.
This is also supported by the fact that the NB1 and NB2 exercises
produced the lowest fit factors only 2% and 5% of the time,
respectively, for good-fitting respirators.
One commenter noted that ``[e]limination of the normal breathing,
deep breathing, and talking fit test exercises from the proposed Fast
protocols has significant potential for adverse impact on PortaCount
fit test results in the real world'' (OSHA-2015-0015-0022). With
respect to normal breathing and talking, the commenter noted that
several studies not mentioned by the three Richardson studies indicate
that the first normal breathing exercise fit factor is typically lower
than fit factors from all subsequent exercises and that the talking
exercise also often results in a lower fit factor. But this commenter
did not provide any basis to believe eliminating these exercises will
put workers at risk. Indeed, he conceded that ``respirator donning has
a greater effect on respirator fit than do fit test exercises'' and
``the lower fit factors produced by the talking exercise appear to be
more consistent with sampling artifact than with actual exercise
dynamics.'' And, as TSI explained, fit factors for the second normal
breathing exercise are likely to be contaminated by prior exercises
(OSHA-2015-0015-0008). Finally, this commenter offered no data or
published information that suggest deep breathing is more rigorous than
other exercises or that eliminating deep breathing will put workers at
risk.
One commenter (OSHA-2015-0015-0029) stated that ``our experience
strongly suggests that the Deep Breathing and Talking Exercises are
frequently the exercises that see the lowest fit factors calculated and
often are `THE Exercises' which determine whether a respirator wear
will achieve a Pass or Failure following the completion of the fit test
series of exercises.'' He further suggested ``a more thorough
evaluation of this change by a third party such as NIOSH-NPPTL. . . .''
Another commenter requested that a review of the studies be performed
by an independent third party (OSHA-2015-0015-0040). NIOSH/NPPTL did in
fact review and evaluate the studies. In the comments NIOSH submitted
to OSHA, NIOSH did not express any concern over the removal of the
talking exercise and ultimately ``recommend[ed] that OSHA accept the
three protocols'' (OSHA-2015-0015-0031).
Regarding all these comments, the industrial hygiene community has
not come to a consensus as to which test exercises must be used in a
new fit testing protocol. Neither the ANSI annex nor OSHA's appendix
requires any specific test exercise(s) be used in a new fit testing
protocol. Further, in 2004, OSHA approved an abbreviated version of the
CNP protocol, called the CNP REDON protocol, which excludes the deep
breathing and talking exercises, and includes only the facing forward
(same as normal breathing), bending over, and head shaking exercises.
In sum, the information submitted in the public comments did not
convince OSHA that the elimination of the deep breathing and talking
exercises adversely impacted the acceptability of the proposed
protocols,
[[Page 50749]]
which met the sensitivity, specificity, predictive value, and other
criteria contained in the ANSI annex.
9. Is the test exercise, jogging-in-place, that has been added to
the Fast-Full and Fast-Half protocols appropriately selected and
adequately explained? Should the jogging exercise also be employed for
the Fast-FFR protocol? Is the reasoning for not replacing the talking
exercise with the more rigorous jogging exercise in the Fast-FFR
protocol (as was done in Fast-Full and Fast-Half) adequately explained?
One commenter was of the opinion that ``[t]he jogging exercise,
while rigorous, is not representative of real-life civilian
activities'' (OSHA-2015-0015-0024). NIOSH stated that it would have
liked to have seen references to support that the jogging-in-place
exercise used in the protocols for elastomeric respirators was
aggressive in evaluating the respirator seal. However, this did not
prevent NIOSH from recommending that OSHA approve the proposed
protocols (OSHA-2015-0015-0031). Furthermore, as stated above under
question #8, the industrial hygiene community has not come to a
consensus as to which test exercise(s) must be included in new fit
testing protocols. More importantly, neither the ANSI annex nor OSHA's
appendix requires that any specific test exercise(s) be used in a new
fit testing protocol.
10. Was it acceptable to omit the grimace from the reference method
employed in the studies evaluating performance of the proposed fit
testing protocols? Is it appropriate to exclude the grimace completely
from the proposed protocols, given that it is not used in the
calculation of the fit factor result specified under the existing or
proposed test methods? If not, what other criteria could be used to
assess its inclusion or exclusion?
One commenter (OSHA-2015-0015-0026) stated that he ``seriously
question[s] the choice of the study and protocol authors in removing
the Grimace exercise.'' While he ``concur[s] with their statement that
it cannot be consistently applied and with their statement that the fit
factor if measured should not be used in calculation of the fit
factor,'' his ``interpretation is that the importance of the grimace is
not in the fit factor achieved during this step of the protocol but
instead in the ability of the mask to re-seal after this exercise which
goes to the respirator['s] proper fit.''
While NIOSH (OSHA-2015-0015-0031) ``recommends that the grimace
test be included in the abbreviated protocols when used in the
workplace since it is part of the currently accepted protocols,'' NIOSH
agrees that the new ``protocols provide a valid reason for not
including [the grimace] in the method comparison testing since it would
add a non-controlled variable.'' Similarly, another commenter stated:
The Grimace exercise is intended to break the face seal and then
measure the recovery of the seal in the following exercises. By
breaking the seal in the Grimace exercise during the reference
protocol you have now altered the original fit of the mask and
compromised the second fit test data. Therefore it makes logical
sense that this exercise was eliminated from the test procedure for
both the reference test and the proposed test. The fit of the mask
as originally donned is consistent for both the reference test and
the proposed protocol test (OSHA-2015-0015-0035).
OSHA agrees that it is reasonable to remove the grimace exercise
from the reference method during the method comparison testing, because
its inclusion would unpredictably impact respirator fit. Some
respirator fit test protocols include the grimace exercise because it
is believed that it will unseat the respirator facepiece; whether this
occurs is assessed, however, only during the subsequent exercise--fit
measured during the grimace exercise is not included in the calculation
of overall fit. Because method comparison requires a range of fit
factors (from poor- to well-fitting respirators), OSHA believes that
excluding the short grimace exercise allows for a more consistent
assessment of fit between the reference and new fit test protocols.
Finally, neither the ANSI annex nor the OSHA appendix specifies
which exercises must be used in a new fit testing protocol. The 2010
ANSI Z88.10 standard specifically considers the grimace exercise to be
elective for the particle-counting instrument quantitative fit test
procedure that it describes (see Table I). And although OSHA requires
the grimace exercise as part of the original ambient aerosol CNC
protocol, OSHA approved an abbreviated CNP REDON protocol in 2004 that
excluded the grimace exercise among four other exercises. As such, OSHA
concludes that it is not necessary to add the grimace exercise to the
proposed protocols.
11. The protocols in the three studies specify that participants
take two deep breaths at the extreme of the head side-to-side and head
up-and-down exercises and at the bottom of the bend in the bend-forward
exercise. According to the developers of these protocols, the deep
breaths are included to make the exercises more rigorous and
reproducible from one subject to the next. Are these additional
breathing instructions adequately explained in the studies and in the
proposed amendment to the standard? Are they reasonable and
appropriate?
OSHA received no comments regarding these questions, which suggests
that the breathing instructions were adequately explained in both the
studies and in the proposed amendment to the standard, and that
stakeholders were not concerned about this issue.
12. Does OSHA's proposed regulatory text for the two new protocols
offer clear instructions for implementing the protocols accurately?
Neither TSI nor any commenters expressed concern about the clarity
of OSHA's proposed regulatory text instructions for implementing the
protocols. In the absence of such comments, the only changes that OSHA
has made to the proposed regulatory text include an expansion of the
titles of Tables A-1 and A-2 to match the names of the new protocols
exactly. OSHA did this solely for clarity, so employers correctly
correlate these two new tables with the two new proposed protocols.
Several commenters expressed miscellaneous concerns that did not
fall directly under any of OSHA's specific questions for public
comment. OSHA addresses each in turn. One commenter was not in favor of
any quantitative fit testing methods because, in his view, qualitative
fit tests are more convincing to the respirator wearers themselves
(OSHA-2015-0015-0017):
[p]assing quantitative measurements may be literally orders of
magnitude apart. If the machine says a 13 is passing, and a 400 is
passing as well, how are the wearers of the respirators supposed to
feel when they compare their numbers? (I have literally seen those
numbers before entering a CBRN Defense Training Facility (CDTF) with
live nerve and mustard agent; each individual was concerned that
his/her mask was not as ``good'' as the other's, as they had no idea
what the numbers meant.
As an initial matter, this rulemaking was not intended to compare
qualitative fit tests to quantitative fit tests--employers are free to
choose such tests as appropriate under appendix A of the Respiratory
Protection Standard. The two new protocols will serve only as
additional quantitative fit testing options to employers. That said,
qualitative fit testing is not appropriate for certain respirators. In
fact, the individuals described by the commenter could not have used
qualitative fit testing because proper protection against CBRN
(chemical, biological, radiological and nuclear) exposures
[[Page 50750]]
requires a full-facepiece, which must be fit tested using a
quantitative method.\11\
---------------------------------------------------------------------------
\11\ Qualitative fit tests are limited to negative pressure air-
purifying respirators that must achieve a fit factor of 100 or less,
i.e., they may only be used to fit test half-mask, not full-
facepiece, respirators. 29 CFR 1910.134(f)(6).
---------------------------------------------------------------------------
Another commenter was concerned about shortening the protocols to
less than an eight-minute period, because she thought that symptoms of
claustrophobia/panic attacks might not manifest before eight minutes
(OSHA-2015-0015-0021). However, the risk of claustrophobia/panic
attacks is already addressed when the wearer is required, under Sec.
1910.134(e)(1) of the Respiratory Protection Standard, to undergo a
mandatory medical evaluation ``to determine the employee's ability to
use a respirator, before the employee is fit tested or required to use
the respirator in the workplace.'' And the mandatory medical
questionnaire in Appendix C of the standard includes a question
regarding claustrophobia. In addition, OSHA is unaware of this having
been an issue for respirator wearers fit tested using the CNP REDON
protocol, which also lasts less than eight minutes and was approved by
OSHA in 2004.
Two commenters who favored shorter protocols expressed interest in
making the new protocols available on all ambient aerosol CNC-based fit
testing instruments, particularly the older PortaCount[supreg] (model
8020) machines (OSHA-2015-0015-0028, OSHA-2015-0015-0030). OSHA notes
that the new protocols are not restricted to any particular testing
instrument because OSHA only approves fit testing protocols, not
specific fit testing machines.\12\ OSHA has no authority to require
specific fit testing machines or models for new protocols. Employers
must contact the manufacturers of CNC fit testing machines to determine
which models support the new protocols.
---------------------------------------------------------------------------
\12\ TSI informed OSHA that the new protocols would not be
available on the now-discontinued 8020 models (OSHA-2015-0010).
---------------------------------------------------------------------------
E. Conclusions
After reviewing the comments submitted to the record, OSHA finds
that the two proposed modified ambient aerosol CNC quantitative fit
testing protocols are supported by peer-reviewed studies that were
conducted according to accepted experimental design practices and
principles and that produced results that were properly, fully, and
fairly presented and interpreted. In addition, based on the peer-
reviewed studies and comments submitted to the record, OSHA finds that
the two proposed protocols meet the sensitivity, specificity,
predictive value, and other criteria contained in the ANSI annex.
Moreover, the proposed protocols met the criteria of the ANSI annex,
and in the absence of any compelling data or research in the record
that would suggest that the proposed protocols would not generate
reproducible fit testing results, OSHA concludes that the proposed
protocols will generate reproducible fit testing results. In summary,
OSHA concludes that the two proposed protocols are sufficiently
accurate and reliable to approve and include in appendix A of its
Respiratory Protection Standard.
F. N95-CompanionTM Technology
The original TSI PortaCount[supreg] machine (model 8020) could only
be used to fit test respirators equipped with >=99% efficient filter
media (i.e., N-, R-, or P-99 and 100 NIOSH filter designations). In
1998, TSI introduced the N95-CompanionTM Technology, which,
when combined with the PortaCount[supreg] 8020 model, could be used to
fit test respirators equipped with <99% efficient filter media (e.g.,
N95 NIOSH filter designation). TSI no longer manufactures the 8020
model, which was replaced by a second generation of PortaCount[supreg]
instruments (models 8030 and 8038). TSI introduced a third generation
of PortaCount[supreg] instruments (models 8040 and 8048) in November
2017. Models 8030 and 8040 can only test the most efficient filters
(i.e., 99 and 100 NIOSH filter designations), while models 8038 and
8048, which include the N95 CompanionTM Technology already
built into the machine, can test any type of filter by selecting the
appropriate operating mode. Because employers are sometimes confused by
this distinction, OSHA considered using this rulemaking to propose
additional language to Part I.C.3 of appendix A of the Respiratory
Protection Standard to reflect this technological development. The
additional language proposed by OSHA did not alter the fit testing
protocol or impose any new requirements on employers; it was merely
intended for clarification purposes.
One commenter expressed concern over the use of the brand name
``Portacount[supreg]'' within the regulatory text, stating that
``[t]his seems to exclude other potential CNC providers'' (OSHA-2015-
0015-0024). Regarding this comment, the original OSHA-approved ambient
aerosol CNC protocol is often commonly referred to as the
PortaCount[supreg] protocol because of the name of the CNC machines
manufactured by the company (i.e., TSI) that proposed the original
protocol. OSHA is aware of only one other manufacturer that produces
CNC instrumentation that is sold in the U.S. at this time. This new CNC
instrumentation was only recently introduced into the market, so OSHA
estimates that the overwhelming majority of the CNC instruments used in
the U.S. at this time are still TSI PortaCount[supreg] machines. As
such, OSHA determined that it is in the best interests of worker health
and safety to retain the PortaCount[supreg] name within the regulatory
text, as it has appeared in appendix A since 1998. This language is not
intended to be exclude other manufacturers. It is intended merely to
reflect that TSI's machines are those typically used for this test at
this point in time. OSHA does not approve any safety equipment or
require employers to use specific brands of safety equipment. However,
it does sometimes refer to company or brand names when it is in the
interest of safety and health. For example, appendix A of the
Respiratory Protection Standard also includes the brand name (i.e.,
Bitrex[supreg]) for the substance (i.e., denatonium benzoate solution
aerosol) overwhelmingly used for one of the OSHA-approved qualitative
fit testing protocols. In addition, appendix A refers to the name of
the company (i.e., Occupational Health Dynamics) that proposed the
original CNP protocol and manufacturers CNP instrumentation.
OSHA has, however, decided not to add the clarifying information
about the different types of PortaCount[supreg] machines, due to
commenter concerns that the inclusion of such information could create
the appearance of a product endorsement. Since OSHA approves fit
testing protocols rather than machines, OSHA feels that employers can
contact fit testing instrument manufacturers for product specificity
and capabilities.
III. Procedural Determinations
A. Legal Considerations
OSHA's Respiratory Protection Standard is based on evidence that
fit testing is necessary to ensure proper respirator fit for employees,
which protects them against excessive exposure to airborne contaminants
in the workplace. Employers covered by this revision already must
comply with the fit testing requirements specified in paragraph (f) of
OSHA's Respiratory Protection Standard at 29 CFR 1910.134.
OSHA has determined that the additional modified ambient aerosol
CNC protocols provide employees with protection that is comparable to
the protection afforded them by the existing fit testing provisions.
The additional
[[Page 50751]]
modified ambient aerosol CNC protocols do not replace existing fit
testing protocols, but instead are alternatives to them. Therefore,
OSHA finds that the final standard does not directly increase or
decrease the protection afforded to employees, nor does it increase
employers' compliance burden. The additional modified ambient aerosol
CNC protocols reduce the total fit test duration, and therefore may
reduce the compliance burden for employers that elect to use one of
these protocols.
B. Final Economic Analysis and Regulatory Flexibility Certification
The rule is not economically significant under Executive Order
12866 (58 FR 51735) or a ``major rule'' under Section 804 of the Small
Business Regulatory Enforcement Fairness Act of 1996 (5 U.S.C. 804).
The rule imposes no additional costs on any private- or public-sector
entity and is not a significant or major rule under Executive Order
12866 or other relevant statutes or executive orders. This rulemaking
increases employers' flexibility in choosing fit testing methods for
employees, and the final rule does not require an employer to update or
replace its current fit testing method(s) if the fit testing method(s)
currently in use meets existing standards. Furthermore, because the
rule offers additional options that employers would be expected to
select only if those options did not impose any net cost burdens on
them, the rule will not have a significant impact on a substantial
number of small entities.
OSHA received several comments in response to the NPRM related to
the time savings anticipated by the proposal. As discussed in the
``Summary and Explanation,'' a number of commenters noted that time
savings of the proposed fit testing protocols would increase efficiency
and be substantial when aggregated across a large number of employees
(OSHA-2015-0015-0018, OSHA-2015-0015-0020). No comments indicated that
the time savings estimates would be significantly different from those
put forth in the Preliminary Economic Analysis (PEA).\13\ As a result,
OSHA has not changed its methodology for calculating the potential cost
savings of implementing the new protocols.
---------------------------------------------------------------------------
\13\ As discussed in the ``Summary and Explanation,'' several
comments (OSHA-2015-0015-0022, OSHA-2015-0015-0032, OSHA-2015-0015-
0042) expressed concern about the estimated decrease in total
ambient test time included as part of the protocol. The ``Summary
and Explanation'' explains why this test time is reasonable and
sufficient in this context. However, the comments did not question
the total estimated time savings for the new protocols, per se.
---------------------------------------------------------------------------
The new quantitative fit testing (QNFT) protocols will provide
employers additional options to fit test their employees for respirator
use. While OSHA approves fit testing protocols rather than fit testing
machines, OSHA understands that, currently, the market for fit testing
machines using the original ambient aerosol CNC protocol is dominated
by TSI's PortaCount[supreg] machines (Models 8020, 8030, 8038, 8040,
8048).\14\ As such, OSHA's Final Economic Analysis (FEA) focuses
specifically on TSI's PortaCount[supreg] machines. Employers already
using the original ambient aerosol CNC protocol with a
PortaCount[supreg] machine (with the exception of the now-discontinued
8020) may switch from the original ambient aerosol CNC protocol to the
new protocols. OSHA estimates switching saves approximately 5 minutes
per fit test, and grants the employer corresponding cost savings.
---------------------------------------------------------------------------
\14\ TSI indicated that as of the beginning of 2018, there were
no active competitors, but that at least one company may be entering
the market later in the year (OSHA-2015-0015-0046).
---------------------------------------------------------------------------
According to TSI, ``[e]xisting owners of the PortaCount[supreg]
Respirator Fit Tester Pro Model 8030 and/or PortaCount[supreg] Pro+
Model 8038 will be able to utilize the new protocols without additional
expense. It will be necessary for fit testers to obtain a firmware and
FitPro software upgrade, which TSI will be providing as a free
download. As an alternative to the free download, PortaCount[supreg]
Models 8030 and 8038 returned for annual service will be upgraded
without additional charge. Owners of the PortaCount[supreg] Plus Model
8020 with or without the N95-CompanionTM Technology (both
discontinued in 2008) will be limited to the current 8-exercise OSHA
fit test protocol'' (OSHA-2015-0015-0010).\15\ There are approximately
12,000 Model 8030 or 8038 units in the field.\16\ Existing
PortaCount[supreg] users may adopt the new protocols with minimal
effort: The fit tester will be able to select the new protocol after
taking an estimated less than five minutes to download TSI's firmware
and software updates. The individual being fit tested is also likely to
learn the new protocols with minimal time. In fact, information about
the new protocols could be imparted during the annual training mandated
by OSHA's respiratory protection rule (OSHA-2015-0015-0012). As a
practical matter, the new protocols contain fewer exercises requiring
mastery. And Part I.A.12 of appendix A of OSHA's Respiratory Protection
Standard already requires the fit tester to describe the fit test to
the respirator wearer, regardless of which fit test it is or how often
it is used. Thus, there should be no additional burden to the employer
or employee.
---------------------------------------------------------------------------
\15\ TSI later confirmed this information still applied in 2018,
even after the introduction of their new models (OSHA-2015-0015-
0046).
\16\ As indicated by TSI in 2015 (OSHA-2015-0015-0012). As
explained later on in this FEA, the aggregate cost savings were
based on estimates of current use of the 8030 and 8038 models. As
the market is now being augmented with the 8040 and 8048 models, it
is likely a conservative estimate of the potential cost savings.
---------------------------------------------------------------------------
OSHA anticipates many employers who currently use the original
ambient aerosol CNC protocol will adopt the new protocols because they
could be adopted at negligible cost to the employer and would take less
time to administer. OSHA expects that the new protocols are less likely
to be adopted by employers who currently perform fit testing using
other quantitative or qualitative fit tests because of the significant
equipment and training investment that they already have made to
administer these fit tests. For example, OSHA estimates, based on
information from TSI, that switching from qualitative to quantitative
fit testing would require upfront costs of $8,700 to $12,000 per
machine (OSHA-2015-0015-0012).
OSHA has estimates of the number of users of the PortaCount[supreg]
technology at the establishment level, both from the manufacturer and
from the 2001 NIOSH Respirator Survey. However, what is not known is
how many respirator wearers, that is, employees, are fit tested using a
PortaCount[supreg] device. As described in the PEA, OSHA expects that
economies of scale will apply in this situation--larger establishments
will be more likely to encounter situations needing QNFT, but will also
have more employees over which to spread the capital costs. OSHA
received no comments about its understanding of employer size in
relation to QNFT use. Once employers have invested capital in a
quantitative fit testing device, they have more of an incentive to
perform QNFT in a given situation, even if not technically required to
use QNFT in every situation. Also, some QNFT devices are acquired by
third parties, or ``fit testing houses,'' that provide fit testing
services to employers. In short, as put forth in the PEA, OSHA believes
that employers using PortaCount[supreg] QNFT will process more
respirator wearers than the average establishment. OSHA received no
comments about this conclusion.
As set forth in the PEA, if one started with an estimate of 12,000
establishments using PortaCount[supreg]
[[Page 50752]]
models 8030 and 8038 annually for all of their employees and assumed an
average of 100 respirator wearers fit tested annually per
establishment, this yielded an estimate of 1.2 million respirator
wearers that could potentially benefit from the new QNFT protocols.\17\
Alternatively, as also set out in the PEA, a similar estimate would
have been obtained if one assumed, employing data from the 2001 NIOSH
Respirator Survey, that 50 percent of the devices requiring QNFT (such
as full-facepiece elastomeric negative pressure respirators) use
PortaCount[supreg] currently, as well as 25 percent of half-mask
elastomeric respirators, and 10 percent of filtering facepieces.\18\
These estimates in the PEA were not questioned in public comment. In
the intervening period between the PEA and the FEA, the total number of
employees and estimated respirator wearers increased somewhat, raising
the estimated number of respirator wearers affected by the rulemaking,
based on survey data, to approximately 1.3 million.
---------------------------------------------------------------------------
\17\ TSI estimated the number of users of their devices at over
12,000 establishments (OSHA-2015-0015-0012). As indicated in the
PEA, this was consistent with data from the 2001 NIOSH respirator
survey (OSHA-2015-0015-0045), which, if benchmarked to a 2012 count
of establishments (OSHA-2015-0015-0048) and containing fit testing
methods to include ambient aerosol, generated aerosol, and a
proportionally allocated percentage of the ``don't know''
respondents, would provide an estimate of 12,458 establishments
using PortaCount[supreg] currently. Based on information from TSI,
the large majority of these are estimated to be the newer 8030 and
8038 devices.
\18\ Based on the 2001 NIOSH respirator survey (OSHA-2015-0015-
0045), benchmarked to 2015 County Business Patterns (OSHA-2015-0015-
0048), OSHA estimates 1,273,616 (or approximately 1.3 million)
employees will be affected by the rulemaking. These estimates are
based only on private employers. Accounting for governmental
entities would result in an even larger number of total estimated
respirator users affected.
---------------------------------------------------------------------------
If applied to approximately 1.3 million respirators wearers, an
estimated savings of 5 minutes per respirator wearer would equal over
100,000 hours of employee time saved annually. Consistent with
Department of Labor policy for translating the labor time savings into
dollar cost savings for this FEA, OSHA included an overhead rate when
estimating the marginal cost of labor in its primary cost calculation.
Overhead costs are indirect expenses that cannot be tied to producing a
specific product or service. Common examples include rent, utilities,
and office equipment. Unfortunately, there is no general consensus on
the cost elements that fit this definition. The lack of a common
definition has led to a wide range of overhead estimates. Consequently,
the treatment of overhead costs needs to be case-specific. OSHA adopted
an overhead rate of 17 percent of base wages, consistent with overhead
rates used for other regulatory compliance rules.\19\ For example, this
is consistent with the overhead rate used for sensitivity analyses in
the 2017 Improved Tracking FEA and the FEA in support of OSHA's 2016
final standard on Occupational Exposure to Respirable Crystalline
Silica. For example, in this case, to calculate the total labor cost
for a typical respirator wearer, based on the mean worker wage, three
components are added together: Base wage ($23.86) + fringe benefits
($10.42--43.7% of $23.86); \20\ and the applicable overhead costs
($4.06--17% of $23.86). This results in an hourly labor cost of a
respirator wearing employee to $38.34. This implies an estimated cost
savings of $4.1 million attributable to the adoption of the new fit
testing protocols.
---------------------------------------------------------------------------
\19\ The methodology was modeled after an approach used by the
Environmental Protection Agency. More information on this approach
can be found at: U.S. Environmental Protection Agency, ``Wage Rates
for Economic Analyses of the Toxics Release Inventory Program,''
June 10, 2002. This analysis itself was based on a survey of several
large chemical manufacturing plants: Heiden Associates, Final
Report: A Study of Industry Compliance Costs Under the Final
Comprehensive Assessment Information Rule, Prepared for the Chemical
Manufacturers Association, December 14, 1989.
\20\ Mean wage rate of $23.86 (OSHA-2015-0015-0043), assuming
fringe benefits are 30.4 percent of total compensation (OSHA-2015-
0015-0043), or by extension, 43.7% of base wages (1/(1-bw)).
---------------------------------------------------------------------------
Because the $4.1 million represents annual cost savings, the final
estimate is the same when discounted at either 3 or 7 percent. For the
same reason, when the Department of Labor uses a perpetual time horizon
to allow for cost comparisons under E.O. 13771, the annualized cost
savings of the final rule are also $4.1 million with 7 percent
discounting. As indicated earlier, this final estimate includes an
overhead factor in the labor costs. This is estimated to add an
additional savings of approximately 12%, or over $400,000, on what
would have been an estimated savings of $3.6 million.
In addition to costs related to the respirator wearer's time, there
will also likely be time savings for the person administering the fit
tests. However, OSHA did not include this cost savings element in the
PEA because it lacked specific empirical information on this point at
the time of the proposal. OSHA requested comment on this question, but
did not receive any. While OSHA believes this element of the cost
savings is potentially substantial, it is not a critical element for
the FEA, as it is simply a question of how large the cost savings are,
and not required, for example, to determine economic feasibility.
Therefore, OSHA is maintaining in the final analysis the same
analytical approach used in the PEA.\21\
---------------------------------------------------------------------------
\21\ For example, in the PEA OSHA posited that the time saved
may potentially be as much as a 1:1 ratio between the tester and
those being tested. But, for purposes of argument, if the ratio was
only 1:4 (or the equivalent of 1 minute 15 seconds of tester's time
per employee tested), OSHA estimates the cost savings related to the
tester would be an additional $1.3 million.
---------------------------------------------------------------------------
In addition, as discussed, this FEA does not account for potential
conversions from testing methods other than the original ambient
aerosol CNC protocol. While such conversions could further increase
time and cost savings, OSHA cannot predict the number of conversions
with confidence. In short, while certain factors could change the
precise cost savings estimates in the FEA, OSHA believes its estimates
reasonably capture the direction and order of magnitude of the
rulemaking's economic effects.
Regulatory Flexibility Certification
In accordance with the Regulatory Flexibility Act, 5 U.S.C. 601 et
seq. (as amended), OSHA has examined the regulatory requirements of the
final rule to determine whether these requirements will have a
significant economic impact on a substantial number of small entities.
This rule will impose no required costs and could provide a cost
savings in excess of $4 million per year to regulated entities. While
measureable in the aggregate, these savings will be dispersed widely,
and therefore are not estimated to have a substantial economic impact
on any small entity, although the impacts are estimated to be positive.
The Assistant Secretary for Occupational Safety and Health therefore
certifies that the final rule will not have a significant economic
impact on a substantial number of small entities.
C. Paperwork Reduction Act
Overview
The Paperwork Reduction Act (PRA) requires that agencies obtain
approval from OMB before conducting any collection of information (44
U.S.C. 3507). The PRA defines ``collection of information'' to mean
``the obtaining, causing to be obtained, soliciting, or requiring the
disclosure to third parties or the public, of facts or opinions by or
for an agency, regardless of form or format'' (44 U.S.C. 3502(3)(A)).
In accordance with the PRA, 44 U.S.C. 3506(c)(2), OSHA solicited
public comments on proposed revisions to the Respiratory Protection
Standard Information Collection Request (ICR) (paperwork burden hour
and cost
[[Page 50753]]
analysis) for the information collection requirements associated with
the Additional PortaCount[supreg] Quantitative Fit-Testing Protocols:
Amendment to Respiratory Protection Standard proposed rule (81 FR
69747). The Department submitted this ICR to OMB for review in
accordance with 44 U.S.C. 3507(d) on October 7, 2016. A copy of the ICR
for the proposed rule is available to the public at: https://www.reginfo.gov/public/do/PRAViewICR?ref_nbr=201511-1218-005.
Solicitation of Comments
On November 22, 2016, OMB issued a Notice of Action withholding its
approval of the ICR. OMB requested that, ``[p]rior to publication of
the final rule, the agency should provide a summary of any comments
related to the information collection and their response, including any
changes made to the ICR as a result of comments. In addition, the
agency must enter the correct burden estimates.''
No public comments were received specifically in response to the
proposed ICR submitted to OMB for review. However, several public
comments submitted in response to the NPRM, described earlier in this
preamble, substantively addressed provisions containing collections of
information and included information relevant to the burden hour and
costs analysis. These comments are addressed in the preamble, and OSHA
considered them when it developed the revised ICR associated with this
final rule. See the comment analysis in section II.D above.
Under the PRA, a Federal agency cannot conduct or sponsor a
collection of information unless it is approved by OMB under the PRA,
and the collection of information notice displays a currently valid OMB
control number (44 U.S.C. 3507(a)(3)). Also, notwithstanding any other
provision of law, no employer shall be subject to penalty for failing
to comply with a collection of information if the collection of
information does not display a currently valid OMB control number (44
U.S.C. 3512). The revised information collection requirements found in
the final rule are summarized below.
The Department of Labor has submitted the final ICR concurrent with
the publication of this final rule. The ICR contains a full analysis
and description of the burden hours and costs associated with the
information collection requirements of the final rule to OMB for
approval. A copy of the ICR is available to the public at https://www.reginfo.gov/public/do/PRAViewICR?ref_nbr=201904-1218-002. OSHA will
publish a separate notice in the Federal Register announcing the
results of OMB's review. That notice will also include a list of OMB-
approved information collection requirements and the total burden hours
and costs imposed by the final rule.
The additional protocols adopted in this final rule revise the
information collection in a way that reduces existing burden hours and
costs. In particular, the information collection requirement specified
in paragraph (m)(2) of OSHA's Respiratory Protection Standard, at 29
CFR 1910.134, states that employers must document and maintain the
following information on quantitative fit tests administered to
employees: The name or identification of the employee tested; the type
of fit test performed; the specific make, model, style, and size of
respirator tested; the date of the test; and the test results. The
employer must maintain this record until the next fit test is
administered. While the information on the fit test record remains the
same, the time to obtain the necessary information for the fit test
record is reduced since the additional PortaCount[supreg] protocols
will take an employer less time to administer than those currently
approved in appendix A of the Respiratory Protection Standard. As a
result, the total estimated burden hours decrease by 201,640 hours,
from 7,622,100 to 7,420,460 hours. This decrease is a result of the
more efficient protocols established under the final rule. OSHA
accounts for this burden under the Information Collection Request, or
paperwork analysis, for the Respiratory Protection Standard (OMB
Control Number 1218-0099). Note that OSHA cannot require compliance
with the information collection requirements for the new information
collection in this final rule until OMB has approved the information
collection requirements.
Title of Collection: Respiratory Protection Standard (29
CFR1910.134).
OMB Control Number: 1218-0099.
Affected Public: Private Sector--business or other for-profits.
Total Estimated Number of Respondents: 24,710,469.
Total Estimated Number of Responses: 25,042,236.
Total Estimated Annual Time Burden Hours: 7,420,460.
Total Estimated Annual Other Burden: $316,906,665.
D. Federalism
OSHA reviewed this rulemaking according to the Executive Order on
Federalism (E.O. 13132, 64 FR 43255, Aug. 10, 1999), which requires
that Federal agencies, to the extent possible, refrain from limiting
state policy options, consult with states before taking actions that
would restrict states' policy options and take such actions only when
clear constitutional authority exists and the problem is of national
scope. The Executive Order provides for preemption of state law only
with the expressed consent of Congress. Federal agencies must limit any
such preemption to the extent possible.
Under section 18 of the Occupational Safety and Health Act (the
``Act,'' 29 U.S.C. 651 et seq.), Congress expressly provides that
states may adopt, with Federal approval, a plan for the development and
enforcement of occupational safety and health standards (29 U.S.C.
667). OSHA refers to states that obtain Federal approval for such a
plan as ``State Plan states.'' Occupational safety and health standards
developed by State Plan states must be at least as effective in
providing safe and healthful employment and places of employment as the
Federal standards. Subject to these requirements, State Plan states are
free to develop and enforce under state law their own requirements for
occupational safety and health standards. With respect to states that
do not have OSHA-approved plans, OSHA concludes that this standard
conforms to the preemption provisions of the Act. Section 18 of the Act
prohibits states without approved plans from issuing citations for
violations of OSHA standards. OSHA finds that the rule does not expand
this limitation. Therefore, for States that do not have approved
occupational safety and health plans, the rule will not affect the
preemption provisions of Section 18 of the Act.
OSHA's rulemaking to adopt additional fit testing protocols under
its Respiratory Protection Standard at 29 CFR 1910.134 is consistent
with Executive Order 13132 because the problems addressed by these fit
testing requirements are national in scope. OSHA concludes that the fit
testing protocols adopted by this rulemaking provide employers in every
state with procedures that will assist them in protecting their
employees from the risks of exposure to atmospheric hazards. In this
regard, the rule offers thousands of employers across the nation an
opportunity to use additional protocols to assess respirator fit among
their employees. Therefore, the rule provides employers in every state
with an alternative means of complying with the fit testing
requirements specified by paragraph (f) of OSHA's Respiratory
Protection Standard.
Section 18(c)(2) of the Act (29 U.S.C. 667(c)(2)) requires State
Plan states to
[[Page 50754]]
adopt an OSHA standard, or to develop and enforce an alternative that
is at least as effective as the OSHA standard. However, the new fit
testing protocols adopted by this rulemaking provide employers with
alternatives to the existing fit testing protocols specified in the
Respiratory Protection Standard; therefore, the alternative is not,
itself, a mandatory standard. Accordingly, states with OSHA-approved
State Plans are not obligated to adopt the additional fit testing
protocols adopted here. Nevertheless, OSHA strongly encourages them to
adopt the final provisions to provide additional compliance options to
employers in their states.
In summary, this rulemaking complies with Executive Order 13132. In
states without OSHA-approved State Plans, this rulemaking limits state
policy options in the same manner as other OSHA standards. In State
Plan states, this rulemaking does not significantly limit state policy
options.
E. State Plan States
Section 18(c)(2) of the Act (29 U.S.C. 667(c)(2)) requires State
Plan states to adopt mandatory standards promulgated by OSHA, or to
develop and enforce an alternative that is at least as effective as the
OSHA standard. However, as noted in the previous section of this
preamble, states with OSHA-approved State Plans are not obligated to
adopt the provisions of this final rule. Nevertheless, OSHA strongly
encourages them to adopt the final provisions to provide compliance
options to employers in their States. In this regard, OSHA concludes
that the fit testing protocols adopted by this rulemaking provide
employers in the State Plan states with procedures that protect the
safety and health of employees who use respirators against hazardous
airborne substances in their workplace at least as well as the
quantitative fit testing protocols in appendix A of the Respiratory
Protection Standard.
There are 28 states and U.S. territories that have their own OSHA-
approved occupational safety and health programs called State Plans.
The following 22 State Plans cover state and local government employers
and private-sector employers: Alaska, Arizona, California, Hawaii,
Indiana, Iowa, Kentucky, Maryland, Michigan, Minnesota, Nevada, New
Mexico, North Carolina, Oregon, Puerto Rico, South Carolina, Tennessee,
Utah, Vermont, Virginia, Washington, and Wyoming. The following six
State Plans cover state and local government employers only:
Connecticut, Illinois, Maine, New Jersey, New York, and the Virgin
Islands.
F. Unfunded Mandates Reform Act
OSHA reviewed this rulemaking according to the Unfunded Mandates
Reform Act of 1995 (UMRA) (2 U.S.C. 1501-1507) and Executive Order
12875 (58 FR 58093 (1993)). As discussed above in section III.B of this
preamble (``Final Economic Analysis and Regulatory Flexibility
Certification''), OSHA has determined that the rule imposes no
additional costs on any private-sector or public-sector entity. The
substantive content of the rule applies only to employers whose
employees use respirators for protection against airborne contaminants,
and compliance with the protocols contained in the final rule are
strictly optional for these employers. Accordingly, the final rule does
not require additional expenditures by either public or private
employers. Therefore, this rulemaking is not a significant regulatory
action within the meaning of Section 202 of the UMRA, 2 U.S.C. 1532.
As noted above under Section E (``State Plan States'') of this
preamble, OSHA standards do not apply to state or local governments
except in states that have voluntarily elected to adopt an OSHA-
approved State Plan. Consequently, this final rulemaking does not meet
the definition of a ``Federal intergovernmental mandate'' (see 2 U.S.C.
658(5)). Therefore, for the purposes of the UMRA, the Assistant
Secretary for Occupational Safety and Health certifies that this
rulemaking does not mandate that state, local, or tribal governments
adopt new, unfunded regulatory obligations, or increase expenditures by
the private sector of more than $100 million in any year.
G. Applicability of Existing Consensus Standards
Section 6(b)(8) of the Act (29 U.S.C. 655(b)(8)) requires OSHA to
explain ``why a rule promulgated by the Secretary differs substantially
from an existing national consensus standard,'' by publishing ``a
statement of the reasons why the rule as adopted will better effectuate
the purposes of the Act than the national consensus standard.'' The
American National Standards Institute (ANSI) developed a national
consensus standard on fit testing protocols (``Respirator Fit Testing
Methods,'' ANSI Z88.10-2001) as an adjunct to its national consensus
standard on respiratory protection programs. ANSI/AIHA updated the
Z88.10 standard in 2010 (``Respirator Fit Testing Methods,'' ANSI
Z88.10-2010) (OSHA-2015-0015-0007).
Paragraph 7.2 of ANSI/AIHA Z88.10-2010 specifies the requirements
for conducting a particle-counting-instrument (e.g.,
PortaCount[supreg]) quantitative fit test. The modified CNC protocols
adopted by the final rule are variations of this national consensus
standard's particle counting-instrument quantitative fit test
procedures: The new protocols require the same 30-second duration for
fit testing exercises, but not the same exercises as ANSI/AIHA.
However, Annex A2 of ANSI/AIHA Z88.10-2010 recognizes that a
universally accepted measurement standard for respirator fit testing
does not exist and provides specific requirements for evaluating new
fit testing methods. OSHA has concluded that the modified CNC protocols
submitted by TSI meet the evaluation criteria outlined in ANSI/AIHA
Z88.10-2010, Annex A2.
H. Advisory Committee for Construction Safety and Health (ACCSH) Review
of the Proposed Standard
The Contract Work Hours and Safety Standards Act (Construction
Safety Act) (40 U.S.C. 3704), OSHA regulations governing the Advisory
Committee for Construction Safety and Health (ACCSH) (i.e., 29 CFR
1912.3), and provisions governing OSHA rulemaking (i.e., 29 CFR
1911.10) require OSHA to consult with the ACCSH whenever OSHA proposes
a rule involving construction activities. Specifically, 29 CFR 1911.10
requires that the Assistant Secretary provide the ACCSH with ``any
proposal of his own,'' together with ``all pertinent factual
information available to him, including the results of research,
demonstrations, and experiments.''
The addition of two quantitative fit test protocols to appendix A
of OSHA's Respiratory Protection Standard affects the construction
industry because it revises the fit testing procedures used in that
industry (see 29 CFR 1926.103). Accordingly, OSHA provided the ACCSH
members with TSI's application letter, supporting documents, and other
relevant information, prior to the December 4, 2014 ACCSH meeting. OSHA
explained its proposal to add new protocols to the ACCSH at that
meeting, and the ACCSH unanimously approved proceeding with a proposed
rule.
List of Subjects in 29 CFR Part 1910
Fit testing, Hazardous substances, Health, Occupational safety and
health, Respirators, Respiratory protection, Toxic substances.
[[Page 50755]]
Authority and Signature
Loren Sweatt, Acting Assistant Secretary of Labor for Occupational
Safety and Health, U.S. Department of Labor, authorized the preparation
of this document pursuant to Sections 4, 6, and 8 of the Occupational
Safety and Health Act of 1970 (29 U.S.C. 653, 655, 657), 29 CFR part
1911, and Secretary's Order 1-2012 (77 FR 3912).
Signed at Washington, DC, on September 19, 2019.
Loren Sweatt,
Principal Deputy Assistant Secretary of Labor for Occupational Safety
and Health.
Amendments to the Standard
For the reasons stated in the preamble, the agency amends 29 CFR
part 1910 as follows:
PART 1910--[AMENDED]
Subpart I--[Amended]
0
1. Revise the authority citation for subpart I of part 1910 to read as
follows:
Authority: 29 U.S.C. 653, 655, 657; Secretary of Labor's Order
No. 12-71 (36 FR 8754), 8-76 (41 FR 25059), 9-83 (48 FR 35736), 1-90
(55 FR 9033), 6-96 (62 FR 111), 3-2000 (65 FR 50017), 5-2002 (67 FR
65008), 5-2007 (72 FR 31160), 4-2010 (75 FR 55355), or 1-2012 (77 FR
3912), as applicable, and 29 CFR part 1911.
0
2. Amend Part I in appendix A to Sec. 1910.134 as follows:
0
a. Revise Section A.14(a) introductory text;
0
b. In Section C.3:
0
i. Revise the introductory text; and
0
ii. Remove the terms ``PortacountTM'' and ``Portacount'' and
add in their place the term ``PortaCount[supreg]'';
0
c. Redesignate Sections C.4 and 5 of as Sections C.6 and 7;
0
d. Add new Sections C.4 and 5; and
0
e. In newly redesignated Section C.7:
0
i. Revise paragraph (a) and paragraph (b) introductory text; and
0
ii. Redesignate Table A-1 as Table A-3; and
The revisions and additions read as follows:
Sec. 1910.134 Respiratory protection.
* * * * *
APPENDIX A to Sec. 1910.134--FIT TESTING PROCEDURES (MANDATORY)
Part I. OSHA--Accepted Fit Test Protocols
A. Fit Testing Procedures--General Requirements
* * * * *
14. Test Exercises. (a) Employers must perform the following
test exercises for all fit testing methods prescribed in this
appendix, except for the two modified ambient aerosol CNC
quantitative fit testing protocols, the CNP quantitative fit testing
protocol, and the CNP REDON quantitative fit testing protocol. For
the modified ambient aerosol CNC quantitative fit testing protocols,
employers shall ensure that the test subjects (i.e., employees)
perform the exercise procedure specified in Part I.C.4(b) of this
appendix for full-facepiece and half-mask elastomeric respirators,
or the exercise procedure specified in Part I.C.5(b) for filtering
facepiece respirators. Employers shall ensure that the test subjects
(i.e., employees) perform the exercise procedure specified in Part
I.C.6(b) of this appendix for the CNP quantitative fit testing
protocol, or the exercise procedure described in Part I.C.7(b) of
this appendix for the CNP REDON quantitative fit testing protocol.
For the remaining fit testing methods, employers shall ensure that
the test exercises are performed in the appropriate test environment
in the following manner:
* * * * *
C. Quantitative Fit Test (QNFT) Protocols
* * * * *
3. Ambient aerosol condensation nuclei counter (CNC)
quantitative fit testing protocol.
The ambient aerosol condensation nuclei counter (CNC)
quantitative fit testing (PortaCount[supreg]) protocol
quantitatively fit tests respirators with the use of a probe. The
probed respirator is only used for quantitative fit tests. A probed
respirator has a special sampling device, installed on the
respirator, that allows the probe to sample the air from inside the
mask. A probed respirator is required for each make, style, model,
and size that the employer uses and can be obtained from the
respirator manufacturer or distributor. The primary CNC instrument
manufacturer, TSI Incorporated, also provides probe attachments (TSI
mask sampling adapters) that permit fit testing in an employee's own
respirator. A minimum fit factor pass level of at least 100 is
necessary for a half-mask respirator (elastomeric or filtering
facepiece), and a minimum fit factor pass level of at least 500 is
required for a full-facepiece elastomeric respirator. The entire
screening and testing procedure shall be explained to the test
subject prior to the conduct of the screening test.
* * * * *
4. Modified ambient aerosol condensation nuclei counter (CNC)
quantitative fit testing protocol for full-facepiece and half-mask
elastomeric respirators.
(a) When administering this protocol to test subjects, employers
shall comply with the requirements specified in Part I.C.3 of this
appendix (ambient aerosol condensation nuclei counter (CNC)
quantitative fit testing protocol), except they shall use the test
exercises described below in paragraph (b) of this protocol instead
of the test exercises specified in section I.C.3(a)(6) of this
appendix.
(b) Employers shall ensure that each test subject being fit
tested using this protocol follows the exercise and duration
procedures, including the order of administration, described in
Table A-1 of this appendix.
Table A-1-- Modified Ambient Aerosal CNC Quantitative Fit Testing Protocol for Full Facepiece and Half-Mask
Elastomeric Respirators
----------------------------------------------------------------------------------------------------------------
Exercises \1\ Exercise procedure Measurement procedure
----------------------------------------------------------------------------------------------------------------
Bending Over....................... The test subject shall bend at the waist, as if A 20 second ambient
going to touch his/her toes for 50 seconds and sample, followed by a 30
inhale 2 times at the bottom \2\. second mask sample.
Jogging-in-Place................... The test subject shall jog in place comfortably A 30 second mask sample.
for 30 seconds.
Head Side-to-Side.................. The test subject shall stand in place, slowly A 30 second mask sample.
turning his/her head from side to side for 30
seconds and inhale 2 times at each extreme \2\.
Head Up-and-Down................... The test subject shall stand in place, slowly A 30 second mask sample
moving his/her head up and down for 39 seconds followed by a 9 second
and inhale 2 times at each extreme \2\. ambient sample.
----------------------------------------------------------------------------------------------------------------
\1\ Exercises are listed in the order in which they are to be administered.
\2\ It is optional for test subjects to take additional breaths at other times during this exercise.
5. Modified ambient aerosol condensation nuclei counter (CNC)
quantitative fit testing protocol for filtering facepiece
respirators.
(a) When administering this protocol to test subjects, employers
shall comply with the requirements specified in Part I.C.3 of this
appendix (ambient aerosol condensation nuclei counter (CNC)
quantitative fit testing protocol), except they shall use the test
exercises described below in paragraph (b) of this protocol instead
of the test exercises specified in section I.C.3(a)(6) of this
appendix.
(b) Employers shall ensure that each test subject being fit
tested using this protocol follows the exercise and duration
procedures, including the order of administration, described in
Table A-2 of this appendix.
[[Page 50756]]
Table A-2-- Modified Ambient Aerosal CNC Quantitative Fit Testing Protocol for Filtering Facepiece Respirators
----------------------------------------------------------------------------------------------------------------
Exercises \1\ Exercise procedure Measurement procedure
----------------------------------------------------------------------------------------------------------------
Bending Over....................... The test subject shall bend at the waist, as if A 20 second ambient
going to touch his/her toes for 50 seconds and sample, followed by a 30
inhale 2 times at the bottom \2\. second mask sample.
Talking............................ The test subject shall talk out loud slowly and A 30 second mask sample.
loud enough so as to be heard clearly by the
test conductor for 30 seconds. He/she will
either read from a prepared text such as the
Rainbow Passage, count backward from 100, or
recite a memorized poem or song.
Head Side-to-Side.................. The test subject shall stand in place, slowly A 30 second mask sample.
turning his/her head from side to side for 30
seconds and inhale 2 times at each extreme \2\.
Head Up-and-Down................... The test subject shall stand in place, slowly A 30 second mask sample
moving his/her head up and down for 39 seconds followed by a 9 second
and inhale 2 times at each extreme \2\. ambient sample.
----------------------------------------------------------------------------------------------------------------
\1\ Exercises are listed in the order in which they are to be administered.
\2\ It is optional for test subjects to take additional breaths at other times during this exercise.
* * * * *
7. Controlled negative pressure (CNP) REDON quantitative fit
testing protocol.
(a) When administering this protocol to test subjects, employers
must comply with the requirements specified in paragraphs (a) and
(c) of part I.C.6 of this appendix (``Controlled negative pressure
(CNP) quantitative fit testing protocol,'') as well as use the test
exercises described below in paragraph (b) of this protocol instead
of the test exercises specified in paragraph (b) of part I.C.6 of
this appendix.
(b) Employers must ensure that each test subject being fit
tested using this protocol follows the exercise and measurement
procedures, including the order of administration described in Table
A-3 of this appendix.
* * * * *
[FR Doc. 2019-20686 Filed 9-25-19; 8:45 am]
BILLING CODE 4510-26-P