DEPARTMENT OF TRANSPORTATION
National Highway Traffic Safety
Administration
49 CFR Part 572
[Docket No. NHTSA–2013–0118]
RIN 2127–AL04
Anthropomorphic Test Devices; Q3s 3Year-Old Child Side Impact Test
Dummy, Incorporation by Reference
National Highway Traffic
Safety Administration (NHTSA),
Department of Transportation (DOT).
ACTION: Notice of proposed rulemaking
(NPRM).
AGENCY:
This document proposes to
amend our regulations to add
specifications and qualification
requirements for an anthropomorphic
test device (ATD) representing a 3-yearold child, called the ‘‘Q3s’’ side impact
test dummy. The agency plans to use
the Q3s to test child restraint systems to
new side impact performance
requirements which NHTSA will
propose to adopt into the Federal motor
vehicle safety standard for child
restraint systems by way of a separate
NPRM. Adopting side impact protection
requirements is consistent with a
statutory provision set forth in the
‘‘Moving Ahead for Progress in the 21st
Century Act’’ (July 6, 2012), that the
agency issue a final rule to improve the
protection of children seated in child
restraint systems during side impacts.
DATES: You should submit your
comments early enough to ensure that
Docket Management receives them not
later than January 21, 2014. Proposed
effective date: The CFR would be
amended on the date 60 days after date
of publication of the final rule.
ADDRESSES: You may submit comments
to the docket number identified in the
heading of this document by any of the
following methods:
• Federal eRulemaking Portal: Go to
https://www.regulations.gov. Follow the
online instructions for submitting
comments.
• Mail: Docket Management Facility,
M–30, U.S. Department of
Transportation, West Building, Ground
Floor, Rm. W12–140, 1200 New Jersey
Avenue SE., Washington, DC 20590.
• Hand Delivery or Courier: West
Building Ground Floor, Room W12–140,
1200 New Jersey Avenue SE., between
9 a.m. and 5 p.m. Eastern Standard
Time, Monday through Friday, except
Federal holidays.
• Fax: (202) 493–2251.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
SUMMARY:
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Regardless of how you submit your
comments, you should mention the
docket number of this document.
You may call the Docket at 202–366–
9324.
Instructions: For detailed instructions
on submitting comments and additional
information on the rulemaking process,
see the Public Participation heading of
the Supplementary Information section
of this document. Note that all
comments received will be posted
without change to https://
www.regulations.gov, including any
personal information provided. Please
see the Privacy Act discussion below.
Privacy Act: Anyone is able to search
the electronic form of all comments
received into any of our dockets by the
name of the individual submitting the
comment (or signing the comment, if
submitted on behalf of an association,
business, labor union, etc.). You may
review DOT’s complete Privacy Act
Statement in the Federal Register
published on April 11, 2000 (65 FR
19477–78).
FOR FURTHER INFORMATION CONTACT: For
technical issues: Peter Martin, NHTSA
Office of Crashworthiness Standards
(telephone 202–366–5668) (fax 202–
493–2990). For legal issues: Deirdre
Fujita, NHTSA Office of Chief Counsel
(telephone 202–366–2992) (fax 202–
366–3820). Mailing address: National
Highway Traffic Safety Administration,
U.S. Department of Transportation, 1200
New Jersey Avenue SE., West Building,
Washington, DC 20590.
SUPPLEMENTARY INFORMATION:
Table of Contents
I. Introduction
II. Background
a. Evolution of the Dummy
b. Developments
c. Build Level D
III. Description
a. General Construction
b. Instrumentation
IV. Biofidelity
a. Anthropometry
b. Biofidelity Assessment Under Dynamic
Loading
V. Repeatability and Reproducibility
a. R&R in Sled Tests
b. R&R in Component Qualification Tests
VI. Qualification Tests
a. Overview of Proposed Corridors
b. Rationale for the Tests
c. New and Modified Part 572 Tests and
Equipment
d. Proposed Test Specifications and
Performance Requirements
VII. Durability
a. High-Energy Component Tests
b. Q3s Servicing and Maintenance
VIII. Drawings and Patents
IX. Consideration of Alternatives
X. Rulemaking Analyses and Notices
XI. Public Participation
PO 00000
Frm 00002
Fmt 4701
Sfmt 4702
I. Introduction
This document proposes to amend 49
CFR Part 572 to add specifications and
qualification requirements for a test
dummy representing a 3-year-old child,
called the ‘‘Q3s’’ side impact test
dummy. The Q3s is a modified version
of a European side impact dummy. In
accordance with the ‘‘Moving Ahead for
Progress in the 21st Century Act’’
(MAP–21) (Pub. L. 112–141), NHTSA
will be issuing a proposal, which we
expect to publish shortly, to amend
Federal Motor Vehicle Safety Standard
(FMVSS) No. 213, ‘‘Child restraint
systems’’ (49 CFR 571.213), to adopt
side impact protection requirements for
child restraints.1 The agency is
considering a proposal that incorporates
the Q3s in the side impact compliance
test procedure.
This document proposes to
incorporate specifications and
qualification requirements for the Q3s
into 49 CFR Part 572,
‘‘Anthropomorphic test devices.’’ The
Q3s would be specified in a new
subpart W. This NPRM proposes
incorporating by reference a parts list, a
set of design drawings, and a
‘‘Procedures for Assembly, Disassembly
and Inspection (PADI)’’ document, to
ensure that all Q3s dummies are the
same in their design and construction.2
Subpart W of 49 CFR Part 572 would
specify performance tests that serve to
assure that the Q3s responses are within
the established qualification corridors
and further assure the uniformity of
dummy assembly, structural integrity,
consistency of response, and adequacy
of instrumentation. These specifications
ensure the repeatability and
reproducibility of the dummy’s impact
response in child restraint compliance
tests.
The agency plans to propose adding a
side impact test to FMVSS No. 213, one
in which child restraint systems (CRSs)
sold for children weighing up to 18
kilograms (kg) (40 pounds (lb)) must
protect the child occupant in a dynamic
sled test simulating a vehicle-to-vehicle
side impact.3 We are considering using
1 Subtitle E of MAP–21, entitled ‘‘Child Safety
Standards,’’ includes § 31501(a) which states that,
not later than 2 years after the date of enactment
of the Act, the Secretary shall issue a final rule
amending Federal Motor Vehicle Safety Standard
Number 213 to improve the protection of children
seated in child restraint systems during side impact
crashes.
2 Drawings and the PADI for the Q3s are available
for examination in the docket for this NPRM.
3 A discussion of NHTSA’s research evaluating
and developing the side impact test procedure can
be found in Sullivan et al., ‘‘NHTSA’s Evaluation
of a Potential Child Side Impact Test Procedures,’’
22nd International Technical Conference on the
Enhanced Safety of Vehicles, Paper No. 2011–0227
(2011).
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
the Q3s to test child restraints
recommended for children in a weight
range that includes 10 kg to 18 kg (22
to 40 lb). Among other things, we are
considering a proposal that would
require those child restraints to limit the
risk of head and chest injury to children
in a side impact. We are considering
using the Q3s to measure the risk of
head injury by way of a head injury
criterion (HIC) (computed within a
specified timeframe, e.g., 15 millisecond
(ms) (HIC15)), and the risk of chest
injury using thorax deflection as a
criterion.
NHTSA seeks to adopt side impact
protection requirements in FMVSS No.
213 that would be evaluated in a
dynamic test simulating an actual
vehicle crash. Our goal has been to use
an anthropomorphic test device (ATD)
that has a sound biofidelic response
under lateral loading, with internal
instrumentation sufficient to record
injurious body loads. We seek to adopt
an ATD that is suitable for use in
regulatory tests with demonstrated
repeatability, reproducibility, and
durability. Within a test laboratory, the
ATD would be practical to handle and
maintain. The dummy would be
available at a reasonable cost.
The Q3s test dummy appears to have
all of the above attributes. As discussed
in this NPRM, NHTSA is satisfied with
the overall biofidelity of the Q3s and we
have found that it exhibits repeatable
and reproducible performance in CRS
side impact sled testing and in
component-level qualification testing.
The Q3s demonstrates sufficient
durability in high-energy qualification
tests and in CRS side impact sled
testing. The agency has tentatively
concluded that the dummy is a reliable
test device that will provide valuable
data in assessing the potential for injury
in side impacts and is suitable for
incorporation into Part 572.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
II. Background
a. Evolution of the Dummy
The Q3s evolved from predecessor
P-series test dummies developed by the
Netherlands Organization for Applied
Scientific Research (TNO). The P-series
first was introduced into European CRS
standards in 1981 with the adoption of
United Nations Economic Commission
for Europe (UNECE) Regulation No. 44,
‘‘Uniform Provisions Concerning the
Approval of Restraining Devices for
Child Occupants of Power-Driven
Vehicles (Child Restraint Systems).’’
Initially, the P-series of dummies served
only as CRS loading devices to assure
CRS integrity in a frontal dynamic sled
test.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
In 1993, the European Commission
formed a child dummy working group
to develop a successor series of
dummies called the Q-series. It was
envisioned that the Q-series dummies
would be used in frontal and side
impact tests, and would be more
anthropometrically correct than the Pseries, and instrumented to enable
injury assessment for the head, neck,
and chest. The conceptual dummy
design was led by TNO, while working
group members as a whole established
the anthropometry, biofidelity, and
measurement requirements for the new
Q-series. In late 1997, the specifications
for the first dummy of the Q-series, the
three-year-old version known as the
‘‘Q3,’’ were reported by TNO.
In 1999, a dummy manufacturer then
named First Technology Safety Systems
(FTSS) 4 acquired the dummy
development and manufacturing
business of TNO. At that time, testing
indicated that the Q3 dummy’s
performance was suboptimal in frontal
testing and even more so in lateral.5
Around 2001, FTSS initiated the design
cycle for the Q3s, which was an
improved side impact version of the Q3.
In early 2002, NHTSA tested a
prototype version of the Q3s.6 NHTSA
evaluated this Q3s unit using
qualification-style pendulum and
impactor tests to assess functionality,
durability, and biofidelity. We
determined that the thorax of the
prototype appeared biofidelic and
repeatable, but the shoulder and pelvis
were much too stiff. Moreover, the neck
was a single-piece rubber column (i.e.,
it was not segmented by aluminum
discs as is typical in other dummy
necks), and we found its biofidelity to
be marginal in frontal and lateral
flexion. In our tests, we observed that
the rubber neck material tended to
bunch together at maximum flexion,
which appeared to improperly restrict
the neck bending.
4 In 2010, FTSS was merged into a new company,
Humanetics Innovative Solutions (Humanetics). In
this preamble, when we discuss work done by the
company prior to 2010, we use the name FTSS.
When we refer to the company’s activities after
2010, we will refer to the name ‘‘Humanetics.’’
5 The Q3 was assessed in: Berliner et al. (2000),
Comparative evaluation of the Q3 and Hybrid III 3Year-Old dummies in biofidelity and static out-ofposition airbag tests, Stapp Car Crash Journal, V44:
25–50. Since the Q3 had yet to show it was suitable
for side impact testing, NHTSA chose to use the
HIII–3C in child restraint side impact testing the
agency conducted following on the Transportation
Recall Enhancement, Accountability and
Documentation Act of 2000 (TREAD Act). The
testing led up to an advance notice of proposed
rulemaking (ANPRM) which NHTSA published on
May 2, 2002, 67 FR 21836.
6 The unit was a modified Q3 that NHTSA had
owned.
PO 00000
Frm 00003
Fmt 4701
Sfmt 4702
69945
Other organizations acquiring
prototype Q3s units included Transport
Canada and Takata Holdings (Takata).
Transport Canada explored the
biofidelity of the Q3s through impacts
delivered by pendulums and impactor
testing. Takata exercised the dummy by
performing several sets of sled tests with
the ATD seated within a CRS.7 Both
Transport Canada and Takata found
problems with their Q3s units similar to
those found by NHTSA. These problems
were conveyed to FTSS through public
critiques, and through committee
meetings of the International
Organization for Standardization (ISO)
and SAE International (SAE).8
Meanwhile, SAE developed new
biofidelity response targets for childsized side impact ATDs, including a
three-year-old child dummy, to support
work on side impact protection for
children.9 The new child targets were
determined by scaling adult biofidelity
targets previously established by ISO.10
These targets became a new set of
criteria for FTSS to incorporate into the
dummy design, in addition to solving
the functionality and durability
problems noted by NHTSA and the
other organizations.
FTSS continued to work on the Q3s
and in April 2006, released the Q3s
Build Level A, its first production
version of a new, Q3s-specific design.
Within a year, several additional
upgrades were incorporated into the
design and by July 2007 Build Level C
was released.
b. Developments
In 2007, the Occupant Safety Research
Partnership (OSRP),11 together with
7 Takata was developing a ‘‘sled-on-sled’’ test
methodology. Takata was also involved with the
International Organization for Standardization (ISO)
and UNECE Reg. No. 44 committees on CRS sled
test development, and for this purpose Takata also
tested the P3, Q3, and the HIII–3C on its sled
system.
8 ISO is a worldwide standards-setting
organization. The Q3s dummy was discussed in the
meetings of ISO Technical Committee TC 22, Road
vehicles, Subcommittee SC 12, Passive safety crash
protection systems. SAE is also a worldwide
standards-setting organization.
9 The work of SAE to establish biofidelity targets
for child ATDs was overseen by the Biomechanics
and Simulation Standards Committee. The targets
and methodologies are published in Irwin AL,
Mertz HJ, Elhagediab AM, Moss S (2002),
Guidelines for Assessing Biofidelity of Side Impact
Dummies of Various Sizes and Ages. Stapp Car
Crash Journal V46: 297–319.
10 ISO/TR 9790:1999 Road vehicles—
Anthropomorphic side impact dummy—Lateral
impact response requirements to assess the
biofidelity of the dummy.
11 OSRP is an organization of the ‘‘United States
Council for Automotive Research (USCAR),’’ which
is a collaborative technology organization of
Chrysler Group LLC, Ford Motor Company and
General Motors Company.
E:\FR\FM\21NOP2.SGM
21NOP2
69946
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
Transport Canada (TC), tested Q3s Build
Level C units to evaluate the biofidelity
and durability of the dummy, as did
NHTSA. Extensive testing was
conducted to evaluate the biofidelity of
the head, neck, shoulder, thorax, and
pelvis against the new SAE side impact
response corridors. In addition, the
dummy was evaluated against targets for
the response of the neck in flexion and
the response of the shoulder under
lateral loading.12
As a result of the OSRP/TC and
NHTSA evaluations of Build Level C
units, three key deficiencies emerged:
(1) The neck did not provide biofidelic
responses in the lateral bending mode;
(2) the upper femur ball could dislodge
from the hip socket during sled tests;
and (3) the thorax exhibited cracks near
the spine box following typical lateral
impacts.
c. Build Level D
Over the next several years, FTSS
(hereinafter ‘‘Humanetics’’) improved
the performance of the Q3s as a result
of the findings of OSRP/TC and NHTSA.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Neck and Femur and Hip Redesigns
Although Humanetics had
incorporated a redesign of the neck into
Build Level C, the OSRP/TC and
NHTSA tests indicated that the neck
was in need of further work. Previously,
NHTSA had designed a head and neck
retrofit for side impact applications for
the Hybrid III 3-year-old child dummy
(HIII–3C). Tests of this redesigned neck
showed that it provided a more
biofidelic response in lateral flexion,
and better limited the amount of axial
twist than the neck of the Q3s Build
Level C.13 The NHTSA-developed neck
specifications 14 were applied by
12 The fore-aft neck targets had previously served
as design targets for the Q-series (Irwin, AL and
Mertz, HJ (1997), ‘‘Biomechanical Basis for the
CRABI and Hybrid III Child Dummies,’’ Stapp Car
Crash Journal V41: 1–12, SAE International,
Warrendale, PA), while the shoulder targets were
newly developed (Bolte, JH et al., (2003), ‘‘Shoulder
impact response and injury due to lateral and
oblique loading,’’ Stapp Car Crash Journal, V47,
SAE International, Warrendale, PA). NHTSA’s test
results were reported in: Rhule, R (2008), Side
impact child dummy development, 2008 SAE
Government/Industry Meeting, Washington DC,
May 2008. Download at: https://www.nhtsa.gov/
Research/Public+Meetings/SAE+2008+Government
+Industry+Meeting (last accessed March 25, 2013).
OSRP results were reported in ISO committee
meetings.
13 Test results were reported in: Wang, ZJ (2009),
Q3s improvement and Q6s development, 2009 SAE
Government/Industry Meeting, Washington DC,
Feb. 2009. Download at: https://www.sae.org/events/
gim/presentations/2009/jerrywang.pdf (last
accessed March 25, 2013).
14 NHTSA’s retrofit package included highly
detailed specifications, including engineering
drawings for fabrication of the neck component and
response specifications for its dynamic
performance.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Humanetics to the Q3s, and the new
neck was incorporated into the Q3s in
2009, with subsequent revisions by
NHTSA to the neck center cable in
2012.
NHTSA also contributed to the
redesign of the femur and hip and
several other minor parts of the dummy.
The revisions were undertaken to
resolve the problem of the upper femur
ball becoming dislodged from the pelvis
hip cup. This was accomplished by
replacing the femur ball and plastic hip
cup with hardened aluminum
components. The new pelvis design was
incorporated into the Q3s in 2009.
Thorax Material Selection
The thorax of the Q3s is a one-piece
plastic casting. The cracks near the
spine box have been addressed by a
change to a new castable polyurethane
resin material known by its trade name,
Adiprene.
To assess the durability of the Q3s,
NHTSA had established thorax
durability criteria consisting of 100
lateral impacts conducted using the
qualification test parameters (3.8 kg (8.4
lb) impactor at 3.3 meters per second
(m/s)) and ten additional high-severity
impacts at 4.2 m/s. In 2011, Humanetics
incorporated Adiprene into the
production level Q3s. Test dummies
with the new thorax material were able
to meet the agency’s thorax durability
criteria.
Built Level D Retrofit
The above revisions have been
incorporated in a production version of
the Q3s dummy that is commercially
available from Humanetics. Humanetics’
latest version of the Q3s, Build Level D,
was released in December 2010 and
updated in 2011 with the Adiprene
thorax, and again in 2012 with a
revision to the neck center cable. The
latest revisions have been retrofitted to
the four Q3s units owned by NHTSA. In
the agency’s subsequent tests—
including CRS sled testing and
qualification-style impact testing—the
revised neck was demonstrated to meet
NHTSA’s performance criteria, and the
revised pelvis and thorax have shown
no signs of failure and no degradation
of performance.15
III. Description
The Q3s weighs 14.5 kg (32.0 lb). The
539 millimeter (mm) seated height of
the dummy is representative of a 50th
15 NHTSA has prepared and docketed a technical
report, ‘‘Evaluation of the Q3s Three Year Old Child
Side Impact Dummy: Repeatability,
Reproducibility, and Durability (2012),’’ which
includes a section that demonstrates the durability
of the Q3s.
PO 00000
Frm 00004
Fmt 4701
Sfmt 4702
percentile 3-year-old child. The cost of
an uninstrumented Q3s unit is about
$48,750. The cost of a minimum set of
instruments needed for qualification
and compliance testing adds
approximately $18,200, for a total cost
of about $66,950.
a. General Construction
With the exception of fasteners,
instrument mounting plates, and
stiffeners for the femurs, the Q3s is
almost completely devoid of steel. The
Q3s has about half the number of parts
as the HIII–3C, which eases its assembly
and disassembly compared to the
Hybrid III child dummies. The main
parts of the dummy are described
below.16
Head
The Q3s head is a fiberglass mold and
consists of the skull and a removable
rear skull cap. Both parts are covered
with a softer plastic material that
simulates flesh and provides a biofidelic
response to impact. The Q3s has a
featureless face. The flesh is bonded
directly to the skull and skull cap to
ensure a proper fit and cannot be
separated. The head cavity is large
enough to allow use of several
instruments, including linear
accelerometers and angular velocity
sensors.
Thorax
The thorax of the Q3s consists of a
one-piece solid ribcage molded of
polyurethane with a thin layer of
polyvinyl chloride (PVC) ‘‘skin’’ bonded
to the outer aspect. The ribcage is bolted
to an aluminum spine. The molded part
is contoured to take the shape of a
human. The variable thickness of the
part is purposefully designed so that,
together with a properly selected
polyurethane density, the thorax
provides a biofidelic response to impact
loading. An internally mounted IR–
TRACC 17 measures the deflection of the
16 The Q3s leg femur bone is constructed of
polyurethane molded around a steel rod that
reinforces the bone. The lower leg bone is made of
polyurethane. Both the upper and lower leg bones
are surrounded by moldings that simulate flesh.
The feet have no bone structure or articulation. The
Q3s’s arms are a combination of plastics and metal.
The elbow joint can be adjusted and set in a
selected position. Vinyl/foam coverings surround
the bones and hands are part of the lower arm
covering.
17 The Infra Red Telescoping Rod for Assessment
of Chest Compression (IR–TRACC) was developed
by General Motors, and first presented in: Rouhana
SW., Elhagediab AM, Chapp JJ (1998), ‘‘A highspeed sensor for measuring chest deflection in crash
test dummies,’’ Proceedings of the 16th
International Technical Conference on the
Enhanced Safety of Vehicles, Windsor, Ontario,
Canada, May 31–June 4, 1998, Paper Number 98–
S9–O–15, 1998.
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
lateral aspect of the ribcage relative to
the spine. A neoprene suit fits over the
torso, similar to a wetsuit.
Neck
The Q3s neck is a segmented design
that consists of a column of three
natural rubber segments bonded to four
aluminum disks. A six-axis upper neck
load cell is mounted at the neck/head
interface. The rubber segments have an
oval-like shape with circumferential Vshaped grooves. A safety cable made
from wire rope runs through the center
of the neck and provides axial
resistance.
Shoulder
The Q3s shoulder design is molded
from natural rubber into a hollowed,
rectangular structure that allows
controlled buckling when the shoulder
is struck on the lateral aspect. The
shoulder joint itself consists of a ball
and socket in order to simulate the
humerus-scapula joint. The upper arm
has urethane flesh covering the entire
outer surface of the arm which helps
reduce the inertial peak from a
pendulum impact. A string
potentiometer is built into the shoulder
assembly to measure the lateral
deflection of the shoulder socket joint
relative to the spine.
Spine
A short interface block connects the
lower neck to the upper thoracic spine.
The thoracic spine itself is a rectangular
column machined from aluminum and
about 140 mm long. It interfaces with a
rubber cylindrical prism in the upper
lumbar region. A short block connects
the rubber lumbar column to the pelvis
assembly.
Abdomen
The abdomen is similar to other ATDs
in that it consists of a molded, foamfilled shell with a PVC outer skin. This
shell is uninstrumented and fits
between the ribcage and the pelvis.
Pelvis
The pelvis has two parts: A pelvic
bone casting made of a zinc alloy
encased snuggly within a molded
polyurethane flesh. The pelvis casting is
configured to accept an accelerometer
array and a pubic subassembly
accommodating a pubic load cell. The
hip cups and femur heads are hardened
aluminum.
Reversibility
The Q3s design incorporates
reversibility features to accommodate
the dummy’s use for both left and right
side impacts. In NHTSA’s proposed
69947
upgrade to FMVSS No. 213, the Q3s
could be used to test forward-facing and
rear-facing CRSs. The sled system
proposed for use by NHTSA would
position the dummy for a left side
impact when testing forward-facing
CRSs, and for a right side impact when
testing rear-facing CRSs. The PADI
manual describes the steps to convert
the instrumentation from a left to a right
side impact.
b. Instrumentation
Table 1 contains a list of
instrumentation needed to qualify the
Q3s, i.e., the instrumentation needed for
the dummy to meet the qualification
requirements included in the proposed
subpart W. Note that the FMVSS No.
213 side impact test that NHTSA is
considering focuses on measuring head
acceleration, using the three uni-axial
accelerometers at the head center of
gravity (C.G.), and chest deflection,
using the IR–TRACC in the thorax.
Nonetheless, the other instrumentation
listed in the table would be needed for
the qualification test to assess the
performance of significant parts of the
dummy and to ensure the soundness of
the dummy as a whole. The Q3s accepts
additional instrumentation other than
that listed below, such as angular rate
sensors in the dummy’s head.
TABLE 1—REQUIRED INSTRUMENTATION TO QUALIFY THE Q3S DUMMY UNDER PART 572
Location
Measurement
Q3s head C.G. ..............................................................
Q3s upper neck ............................................................
Q3s thorax ....................................................................
Q3s shoulder ................................................................
Q3s lumbar spine .........................................................
Q3s pubic symphysis ....................................................
Qualification test equipment .........................................
Acceleration ..................................................................
Forces and moments ...................................................
Deflection .....................................................................
Deflection .....................................................................
Forces and moments ...................................................
Force ............................................................................
Neck, lumbar rotation ...................................................
IV. Biofidelity
tkelley on DSK3SPTVN1PROD with PROPOSALS2
a. Anthropometry
The anthropometry and dummy
segment mass properties of the Q3s
were defined in the early design stage of
the original Q3 based on TNO’s data in
its Child Anthropometric Database
(CANDAT).18 For the most part, the
18 According to TNO publications (Beusenberg et
al., 1993; Van Ratingen, et al., 1997), CANDAT is
built upon various anthropometry surveys
conducted in the United States, the Netherlands,
Germany, and Japan from 1970–1993 of external
dimensions and overall mass of children from birth
up to 18 years old. Each survey source examined
a different age group, and each had its own set of
unique collection parameters. To handle gaps and
inconsistencies within the source data, TNO
applied regression routines and interpolation
techniques to derive the anthropometry of a
particular body segment size as a function of age or
total body mass. Regression was based on the
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
same anthropometry and mass
distributions have been retained all the
way through to the Build Level D
production version of the Q3s. The Q3s
represents a 50th percentile three-yearold child, based on the data derived
from CANDAT.
Biofidelity targets for a particular
dummy are a function of its
anthropometry and mass. Our
assessment of the Q3s made use of
biofidelity targets derived by SAE.
These response targets were derived
specifically for side impact dummies
that have the same characteristic
dimensions and masses as the Hybrid III
assumption that growth is a smooth and continuous
process. The anthropometry surveys identified by
TNO as the basis of CANDAT were performed by
organizations other than TNO. CANDAT is the
property of TNO and Humanetics.
PO 00000
Frm 00005
Fmt 4701
Sfmt 4702
Instrument
Accelerometer (3 req.).
Load cell.
IR–TRACC.
String potentiometer.
Load cell.
Load cell.
Angular rate sensor (2 req.).
family of dummies. Unlike the TNO
studies used for the Q3s, the
anthropometric basis of the Hybrid III
three-year-old child dummy was
derived by SAE using survey data of
children in the United States only
(Irwin and Mertz, 1997).19 SAE also
used slightly different assumptions to
specify the body segment mass
properties. Nonetheless, the SAE
specifications for the anthropometry
and mass of a three-year-old are very
similar to those based on CANDAT. The
Q3s generally matches up with SAE
specifications as well as it does with
CANDAT specifications.
19 Irwin and Mertz (1997). Biomechanical Basis
for the CRABI and Hybrid III Child Dummies. Stapp
Car Crash Journal V41: 1–12, SAE International,
Warrendale, PA.
E:\FR\FM\21NOP2.SGM
21NOP2
69948
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
There are small differences in body
segment mass properties between the
two ATDs due to differences in the
manner in which TNO and SAE
apportioned the segments. For instance,
the TNO torso does not include parts of
the thighs, whereas the SAE target does
(the HIII–3C’s thighs are included in a
sitting form pelvis consistent with other
Hybrid III dummies, which are built
with a one-piece vinyl covering that fits
around the pelvis and extends midthigh). Since the Q3s is not constructed
in this way, its torso mass is lower than
the SAE target because it includes only
the torso, not part of the thighs.
Conversely, the Q3s thigh mass is higher
than the SAE target, since it includes
more of the thigh segment.
The total body mass of the Q3s
matches that of the HIII–3C, and is very
close to the most recent Centers for
Disease Control (CDC) growth charts.20
Table 2, below, provides the
anthropometry and mass of various
body segments for the Q3s along with
the reference specifications of both
CANDAT (TNO) and SAE. For
reference, CDC data for height and total
mass are footnoted in the table. (Note
that, unlike the erect posture of CDC
subjects, the reference posture of the
Q3s is reclined and the pelvis angle
reflects a child’s seating position in a
CRS. Also, the neck of the Q3s is angled
such that the head is leveled when the
dummy is seated. Thus, the Q3s height
measurement is an approximation only
because the dummy cannot be
positioned in the same fully erect
posture taken by children when their
height is measured.)
The TNO and SAE specifications for
anthropometry appear essentially the
same. The anthropometry of the Q3s is
also close to these specifications, with
the exception of the chest depth and the
waist circumference (both larger in the
Q3s). As compared to a human, the Q3s
torso is more rounded in order to
provide greater internal space for the
installation of the IR–TRACC. When
struck laterally, the rounded torso also
helps to give the dummy a biofidelic
response in terms of the force needed to
achieve proper chest deflection. For the
waist, the difference reflects the seated
reference posture of the Q3s as
compared to the standing posture of
children represented in CANDAT.
When comparing mass, Table 2 shows
that the Q3s head is close to the TNO
target, but it is light in comparison to
the SAE target. For the neck, the Q3s
also is aligned with the TNO target, but
is light in comparison to the SAE. As
discussed in the section below, these
differences in anthropometry
specifications are not significant in
terms of the biofidelity of the Q3s under
impact loading.
The other body segment masses
shown in Table 2 (in italics) do not
reflect a one-to-one comparison because
of differences in apportioning. We note
also that the mass of the upper
extremities is lighter than the SAE value
to compensate for the cumulative excess
mass of the other dummy segments, to
enable the total mass of the Q3s to be
on target.
TABLE 2—Q3S ANTHROPOMETRY AND MASS COMPARED TO TNO AND SAE TARGETS
ANTHROPOMETRY (mm)
TNO
Standing height* ........................................................................................
Sitting height ..............................................................................................
Shoulder height, sitting ..............................................................................
Shoulder breadth (max) .............................................................................
Hip breadth (seated) ..................................................................................
Head depth ................................................................................................
Head breadth .............................................................................................
Head circumference ...................................................................................
Chest breadth ............................................................................................
Chest depth ...............................................................................................
Chest circumference, axilla .......................................................................
Waist circumference ..................................................................................
Thigh height, sitting ...................................................................................
Buttock-knee length ...................................................................................
Shoulder-elbow distance ...........................................................................
Elbow to tip of finger ..................................................................................
SAE
954
551
340
246
194
177
134
500
161
122
508
475
78
293
190
250
% Difference,
Q3s vs. SAE
Q3s
953
546
334
246
193
177
135
498
173
122
505
480
84
284
193
254
986
556
340
247
202
180
138
502
174
151
523
521
86
305
186
240
+3
+2
+2
0
+5
+2
+2
+1
+1
+24
+4
+9
+2
+7
¥4
¥6
MASS (kg)
Total mass** ..............................................................................................
14.5
Head ..........................................................................................................
Neck ...........................................................................................................
Torso assembly .........................................................................................
Upper extremities .......................................................................................
Lower extremities .......................................................................................
14.5
2.90
0.30
6.20
3.50
1.50
3.05
0.40
6.61
1.82
2.63
14.26
¥2
2.81
0.31
5.78
1.41
3.55
¥8
¥23
¥13
¥22
+35
tkelley on DSK3SPTVN1PROD with PROPOSALS2
* Comparable reference: CDC 2000, 50th percentile three-year-old, standing fully erect:
boys: height=950 mm; total mass=14.3 kg
girls: height=940 mm; total mass=13.8 kg
**Total mass of Q3s includes its body suit, 0.40 kg.
20 CDC growth charts for year 2000 are reported
by Kuczmarski RJ, et al. (2002), 2000 CDC growth
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
charts for the United States: Methods and
PO 00000
Frm 00006
Fmt 4701
Sfmt 4702
development. National Center for Health
Statistics.Vital Health Stat 11(246), 2002.
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
b. Biofidelity Assessment Under
Dynamic Loading
Our assessment of the Q3s is based
primarily on biofidelity targets
established by SAE 21 for the head, neck,
shoulder, thorax, and pelvis of a threeyear-old. (A biofidelity target is the
desired performance that a dummy
should attain to be considered
replicating the biomechanical response
of a human.) In addition, we assessed
the Q3s against additional shoulder
targets based on tests carried out at Ohio
State University (Bolte, 2003),22 and
against abdominal targets formulated by
TNO.23 For the most part, the biofidelity
targets are based on pendulum impacts
to body segments using cylindrical test
probes suspended by wire.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Scaling of Adult Human Response Data
Biofidelity targets are based on
observed human responses to impact
loading. Generally, to assess a dummy’s
biofidelity, the human’s response
characteristics must be known. To
assess adult dummies, adult post
mortem human subjects (PMHS) are
exposed to controlled forces, loads, and
impacts and their responses are
measured. However, biomechanical
response data on children under impact
loading is nonexistent or very limited,
so other means must be used to estimate
the human child’s response
characteristics.
Scaling adult PMHS data to the
child’s size using mass, anthropometry,
and stiffness ratios represents the best
available method of estimating the
human child’s response characteristics
(see Irwin and Mertz, 1997 and Irwin,
2002, for details on the scaling theory
and assumptions applied by SAE).
21 NHTSA has evaluated the SAE targets and is
satisfied with the technical bases underlying them.
The SAE targets were derived systematically using
a defined process. The scaling theories as well as
the underlying anthropometric and biomechanical
test data have all been vetted and released to the
public domain. SAE methods have been used by
NHTSA to assess the biofidelity of the majority of
Part 572 ATDs and we find them to be sound, datadriven, and well-founded scientifically.
22 The test procedure and biofidelity targets are
described in: Bolte JH, Hines NH, Herriot RG,
Donnelly BR, McFadden JD (2003). Shoulder impact
response and injury due to lateral and oblique
loading, Stapp Car Crash Journal, V47, SAE
International, Warrendale, PA.
23 We have used this TNO biofidelity target
because there is none for the Q3s abdomen
developed by the SAE. We have not used the TNO
biofidelity targets for the head, neck, shoulder,
thorax, and pelvis because they are derived from
assumptions and underlying data within CANDAT,
some of which have not been made fully accessible
to the public. Thus, due to the transparency and
reliability of the SAE targets and because the TNO
targets cannot be fully judged to the same degree
that SAE targets can be, we have decided to use
primarily the SAE targets in assessing the
biofidelity of the Q3s.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Thus, scaling techniques were used to
derive a set of biomechanical targets for
the Q3s whereby adult PMHS data were
scaled to a three-year-old child. The
targets were determined by scaling the
biomechanical responses observed for
various body segments of the midsize
adult male down to a three-year-old.
Given the lack of pediatric
biomechanical data and the many
assumptions made in the scaling
process, there is greater uncertainty
associated with child biofidelity targets
compared to the adult targets from
which they were derived. Therefore,
NHTSA does not consider the
biofidelity targets applied herein to be
strict prerequisites to accept the
dummy. Although biofidelity targets are
central to evaluating the dummy, we
have had to carefully analyze the
findings to assess the biofidelity of the
child ATD, judging, among other
factors, the extent to which the child
ATD met or missed the scaled target,
and whether this would affect the
usefulness of the ATD in its intended
application.
Q3s Biofidelity Assessment
The agency has prepared a supporting
document, ‘‘Biofidelity Assessment of
the Q3s Three-Year-Old Child Side
Impact Dummy (July 2012),’’ which
provides a detailed discussion of the
agency’s biofidelity assessment, which
is summarized below. A copy of the
report has been placed in the docket for
this NPRM. The report discusses the
performance of the Q3s relative to the
biofidelity targets.
A body part-by-body part synopsis of
the biofidelity performance of the Q3s
under dynamic loading is given below.
For pendulum impacts, biofidelity is
generally assessed as ‘‘external’’ or
‘‘internal.’’ External biofidelity is related
to the force generated on the face of a
pendulum impact probe upon striking a
subject. In other words, probe forces
generated by dummies are compared
against probe forces generated by
PMHS. Internal biofidelity is related to
a measurement on or within the subject
itself, such as shoulder deflection or
spine acceleration, for which
corresponding measurements are made
on both the PMHS and the dummy.
Head
Given that the use of the Q3s in the
FMVSS No. 213 side impact test under
consideration would be to measure risk
of head injury (using a linear
acceleration-based head injury criterion,
HIC), we consider head biofidelity to be
highly important for the ATD. For the
Q3s, we assessed head biofidelity in
both frontal (Irwin and Mertz, 1997) and
PO 00000
Frm 00007
Fmt 4701
Sfmt 4702
69949
lateral (Irwin, 2002) orientations using
Part 572-style head drop procedures.
The responses of the Q3s head are well
within the SAE corridors for both
frontal and lateral drops, i.e., the
responses wholly met the biofidelity
target for the head.
Neck
The behavior of the neck in lateral
flexion affects the overall motion of the
head. We tested the Q3s neck to lateral
flexion according to the SAE protocol
(Irwin, et al., 2002), which uses a
standard Part 572 neck pendulum to
observe the moment-angle relationship.
The Q3s neck response is entirely
within the SAE corridors, completely
meeting the biofidelity target.
We also assessed the biofidelity of the
Q3s neck in frontal flexion (Irwin and
Mertz, 1997). In the frontal flexion
assessment, we found that the Q3s neck
data generally follows the shape of the
corridor of the biofidelity target,
although the curve is not completely
contained within the corridor. Given
that neck flexion occurs mainly in the
lateral direction under the intended use
of the dummy, a slight nonconformity in
frontal flexion is not disconcerting. On
balance, we find the biofidelity of the
Q3s neck to be satisfactory for use in our
CRS side impact safety standard under
consideration.
Shoulder
Although there is no shoulder IARV
being contemplated for the Q3s, the
shoulder does interact with the CRS
during the test procedure under
consideration for FMVSS No. 213. In
view of this, NHTSA evaluated the
biofidelity of the Q3s shoulder in
component testing under the loading of
a pendulum.
The unpadded test involved the SAE
protocol (Irwin, 2002), which uses a
rigid pendulum in a pure lateral
direction. Response criteria included
corridors for lateral shoulder
displacement and for probe force. The
Q3s shoulder showed high stiffness
with respect to lateral shoulder
displacement and probe force under this
test protocol.
Next we reexamined shoulder
biofidelity under conditions that
correspond more closely to the intended
use of the Q3s in the FMVSS No. 213
test procedure being contemplated:
Those of the Ohio State protocol (Bolte
et al., 2003), which uses the same
impactor mass and speed as the SAE
test but with foam padding attached to
the impactor face. The latter condition
was considered because the FMVSS No.
213 impact being contemplated exposes
the Q3s to the padded side structure
E:\FR\FM\21NOP2.SGM
21NOP2
69950
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
(‘‘wing’’) of the child restraint in the
test.
Under the Ohio State protocol, test
results also indicate that the shoulder of
the Q3s is stiff when assessed for
biofidelity as measured by its internal
deflection. However, the force response
of the padded probe (external
biofidelity) nearly matches the target. As
such, the Q3s shoulder appears to be
biofidelic in the manner in which it
would exert force on the child restraint
system. This loading of the child
restraint, which would affect the overall
motion of the dummy’s upper torso and
head (through which the FMVSS No.
213 injury criteria under consideration
would be measured), appears
representative of an actual human.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Thorax
The biofidelity of the thorax under
lateral loading is an important
performance target for the Q3s since the
agency is considering a proposal to
adopt thorax deflection as an injury
assessment reference value (IARV) in
the FMVSS No. 213 side impact test.
Thorax biofidelity is assessed via high
(6.0 m/s) and low (4.3 m/s) speed
pendulum impacts prescribed by SAE.
Pendulum force corridors are used to
assess the external biofidelity of the
dummy, and upper torso (T1)
acceleration is used to assess internal
biofidelity. (SAE did not develop a
biofidelity target based on thorax
deflection because PMHS in the
underlying tests were not instrumented
as such.)
Test results indicate that the
pendulum forces generated by the Q3s
are within the corridors for both high
and low speed tests. The magnitude of
the internal T1 acceleration is also on
target, though it is slightly out of phase
with the biofidelity corridor (i.e., the
peak magnitude is within the limit
afforded by the corridor, but it occurs
about 10 ms too early). We believe this
phase difference, which is related to the
mechanics of human thoracic tissues vs.
the Q3s polymer thorax, is an acceptable
compromise in producing a dummy that
is affordable, durable, and otherwise
practicable for use as a regulatory tool.
Abdomen
We assessed the biofidelity of the
abdomen in an oblique pendulum
impact using probe force targets
established by TNO. This assessment
was carried out with the probe striking
the antero-lateral aspect of the dummy
rather than the full lateral aspect
because neither TNO nor SAE had
established biofidelity targets for the
latter. Furthermore, abdominal
biofidelity is important mostly in frontal
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
impacts in relation to lap belt loading.
Since the Q3s would primarily be used
in side impacts to test CRSs having an
internal harness, abdominal loads are
not expected to be excessive.
Nonetheless, the loading to the
abdomen in the FMVSS No. 213 testing
under consideration may have some
frontal component, with the resultant
loading being oblique. Therefore, the
biofidelity assessment was performed
with an oblique impact. The Q3s
performed very favorably when
examined against the TNO established
targets.24
Moreover, noting that an assumption
was made by TNO that the child
abdomen is stiffer than the adult,
NHTSA re-formulated the corridor by
assuming that abdomen stiffness is a
function of the elastic modulus of soft
tissue, and that child and adult moduli
are the same. (This assumption was also
employed in developing the SAE
corridors for other body regions.) When
compared against the re-formulated
corridor, the Q3s performs a little less
favorably, but still follows along the
upper bound of the corridor. Details of
this comparison are provided in our
supporting document, ‘‘Biofidelity
Assessment of the Q3s Three-Year-Old
Child Side Impact Dummy,’’ supra at p.
17.
Pelvis
The external biofidelity of the pelvis
was assessed using an SAE pendulum
impact protocol (lateral impact of 2.27
kg rigid impact probe at 4.5 m/s) and
pendulum force limits. The test results
indicate that the Q3s pelvis appears stiff
relative to a child. The dummy had been
redesigned with hardened aluminum
hips replacing plastic ones to improve
its durability, and this change may have
resulted in a greater force response.
Nonetheless, in our repeatability and
reproducibility testing with Cozy Cline
CRSs (discussed later), the wide scatter
in pelvis response did not seem to have
any effect on HIC15 and chest
deflection. Further, the tradeoff in
biofidelity for improved durability may
be necessary for use of the dummy in a
regulatory environment.
24 The TNO targets are based on a scaling of adult
PMHS data in which subjects were struck in the
abdomen by a pendulum aligned 30 degrees from
lateral (i.e., an oblique impact). The PMHS data is
from a test series where subjects initially underwent
thoracic impacts and then were re-used for
abdominal impacts. The thoracic impact data were
used to establish thorax corridors in the ISO 9790
Technical Report, the underlying source document
upon which the SAE three-year-old targets have
been derived. The repeat abdominal tests, however,
were not used by ISO and thus no SAE targets are
provided for abdominal biofidelity subjected to
pendulum impacts.
PO 00000
Frm 00008
Fmt 4701
Sfmt 4702
Summary
Our biofidelity assessment of the Q3s
is based on head drops and pendulum
tests, which have demonstrated the
biofidelity of the test dummy. Our test
results indicate that the biofidelity of
the Q3s is most satisfactory for the head,
thorax, and neck. It is in these three
body segments where proper biofidelity
is most critical for the intended use of
the dummy in the FMVSS No. 213 test
procedure under consideration.
Relative to humans, the dummy
appears to be stiff in the shoulder and
pelvis. For a CRS under test, the
shoulder and pelvis could conceivably
act as load paths such that the thorax
deflection in the Q3s may be
unrealistically low relative to a human.
However, it may not be feasible to
engineer a biofidelic design into the
shoulder and pelvis at this time without
sacrificing some other critical
performance features, such as
durability. While a child test dummy
with a more biofidelic shoulder and
pelvis may be developed in the future,
the agency tentatively concludes that
the Q3s is a suitable and valuable test
device for use in child restraint side
impact testing at this time. On balance,
the agency is satisfied with the overall
biofidelity of the Q3s.
V. Repeatability and Reproducibility
A test dummy’s repeatability and
reproducibility (R&R) is demonstrated
in sled tests and component tests. Sled
tests establish the consistency of the
dummy’s kinematics, its impact
response as an assembly, and the
integrity of the dummy’s structure and
instrumentation under controlled and
representative crash environment test
conditions. In component tests, the
impact input as well as the test
equipment is carefully controlled to
minimize external effects on the
dummy’s responses. NHTSA has
assessed the repeatability and
reproducibility of the Q3s in CRS side
impact sled tests and in component
tests.
Repeatability is defined as the
similarity of responses from a single
dummy when subjected to multiple
repeats of a given test condition.
Reproducibility is defined as the
similarity of test responses from
multiple dummies when subjected to
multiple repeats of a given test
condition. A quantitative assessment of
R&R is achieved using a statistical
analysis of variance. The percent
coefficient of variation (%CV) is a
measure of variability expressed as a
percentage of the mean. The %CV is
calculated as follows:
E:\FR\FM\21NOP2.SGM
21NOP2
69951
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
Where s = standard deviation of responses 25
X = mean of responses
We have used a %CV scale shown in
Table 3 to assess the quality of
repeatability and reproducibility of the
Q3s. This approach was first introduced
by NHTSA as a means of evaluating
dummy repeatability when the original
subpart B Hybrid II 50th percentile male
ATD was proposed (40 FR 33466,
August 8, 1975). Since then, the agency
has used this approach for other 49 CFR
Part 572 rulemakings, including those to
adopt side impact dummies such as the
ES–2re midsize adult male side impact
dummy (subpart U, 71 FR 75304,
December 14, 2006) and the SID–IIs 5th
percentile adult female side impact
dummy (subpart V, 71 FR 75342,
December 14, 2006).
TABLE 3—%CV SCORE CATEGORIZATION FOR REPEATABILITY AND REPRODUCIBILITY
Repeatability
% CV Score
Reproducibility
% CV Score
%CV ≤ 5 ....................................................................................
5 < %CV ≤ 8 ..............................................................................
8 < %CV ≤ 10 ............................................................................
%CV > 10 ..................................................................................
%CV ≤ 6 ...................................................................................
6 < %CV ≤ 11 ...........................................................................
11 < %CV ≤ 15 .........................................................................
%CV > 15 .................................................................................
For repeatability and reproducibility
assessments, acceptable limits are
‘‘MARGINAL’’ and above. For
repeatability, the MARGINAL limit is
set at a %CV value of 10 percent. For
MARGINAL reproducibility, a slightly
greater %CV of 15 percent is used since
multiple dummies produce a wider
dispersion of response measurement
than in testing a single dummy for
repeatability. These limits were most
recently used in adopting the HIII–10C
10-year-old child dummy into 49 CFR
Part 572 (subpart T, 77 FR 11651,
February 27, 2012). All R&R values in
the ‘‘POOR’’ category were investigated
to assess the cause of the high variance.
If needed, corrective measures were
made to the dummy.
a. R&R in Sled Tests
In the sled tests, a CRS was mounted
on a generic bench seat which was
allowed to slide into a padded wall,
generating lateral impact loading on the
CRS and the Q3s dummy. The
deceleration pulse of the sliding bench
seat was controlled by the crush of
aluminum honeycomb. The peak lateral
acceleration of the test buck was
approximately 25.4 g and the peak
velocity was 31.4 km/h (19.5 mph).26
The configuration and sled pulse
generally corresponded to the procedure
under consideration for the FMVSS No.
213 side impact test, except the
loadwall had a uniform surface.
To assess the R&R of the Q3s in sled
tests, two dummies were each tested
five times using the sliding seat sled
buck. The simulated wall padding was
replaced after each test. Two sets of seat
padding for the sliding bench were
alternated after each test. The locations
of multiple dummy landmarks were
measured before each test to minimize
test-to-test variation in the dummy’s
seated position.
All tests were performed with
identical forward-facing Graco Cozy
Cline child restraints, with a new child
restraint used for each test. These child
restraints were sold for children
weighing 9 to 18 kg (20 to 40 lb). In CRS
tests performed in support of NHTSA’s
proposed rulemaking to add a side
Assessment
EXCELLENT.
GOOD.
MARGINAL.
POOR.
impact test to FMVSS No. 213, the Cozy
Cline child restraint produced Q3s
metrics that were generally high relative
to those produced by other CRSs. Thus,
we chose to evaluate the R&R of the Q3s
with the Cozy Cline child restraint
because the data indicated that these
child restraints more vigorously
exercised the dummy’s assessment of
the injury criteria of interest compared
to other CRSs we have tested.
The sled test results indicated
‘‘GOOD’’ to ‘‘EXCELLENT’’ repeatability
and reproducibility.27 The statistical
analysis of select measurements in all
tests for each dummy and both
dummies combined is summarized in
Table 4. NHTSA has prepared and
docketed a technical report, ‘‘Evaluation
of the Q3s Three Year Old Child Side
Impact Dummy: Repeatability,
Reproducibility, and Durability (2012),’’
which discusses the test procedures and
results in greater detail. The report also
provides references for the location of
the test data including sensor signals
and videography.
TABLE 4—SUMMARY OF SLED TEST RESPONSES FOR SELECT CHANNELS
Parameter
Std
dev
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Avg
FMVSS 1 ............................
P572 2 & FMVSS 1 ............
Part 572 2 ..........................
R&D 3 ................................
Part 572 2 ..........................
Part 572 2 ..........................
R&D 3 ................................
R&D 3 ................................
R&D 3 ................................
HIC15 ...............................
Thorax Y-Disp, mm ..........
Head Res-Accel, g ...........
Neck Y-force, N ................
Neck X-Moment, Nm ........
Shoulder Y-Disp, mm .......
Up spine Res-Accel, g ......
Lumbar Y-Force, N ...........
Pelvis Res-Accel, g ..........
25 Standard deviations are based on a sample and
calculated using the ‘‘n-1’’ method.
26 The acceleration of the test buck is intended to
mimic the impulse experienced by a CRS installed
in the rear seat of a small passenger vehicle
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
700
34
97
744
31
24
65
324
101
Dummy S/N 007
% CV
14.8
0.8
2.1
56.5
3.8
1.0
3.3
20.7
15.8
2
2
2
8
12
4
5
6
16
Avg
708
33
96
687
28
24
65
343
106
subjected to a side impact by a moving deformable
barrier as specified in FMVSS No. 214, ‘‘Side
impact protection.’’
27 Qualification tests were performed on each
dummy before and after the sled test series to
PO 00000
Frm 00009
Fmt 4701
Sfmt 4702
Std
dev
Combined Data
% CV
19.4
2.8
2.0
57.3
2.3
0.8
8.2
38.8
22.9
3
9
2
8
8
3
13
11
22
Avg
704
34
96
716
29
24
65
333
104
Std
dev
16.8
2.0
2.0
61.4
3.4
0.8
5.9
31.0
18.7
% CV
2
6
2
9
12
4
9
9
18
evaluate the Q3s’s durability. The dummies met all
of the preliminary qualification response
requirements, both before and after the sled series.
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.000
Dummy S/N 006
Used for:
69952
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE 4—SUMMARY OF SLED TEST RESPONSES FOR SELECT CHANNELS—Continued
Dummy S/N 006
Used for:
Parameter
Std
dev
Avg
Part 572 2 ..........................
Pubic Y-Force, N ..............
388
Dummy S/N 007
% CV
43.4
11
Avg
324
Std
dev
Combined Data
% CV
75.5
23
Avg
356
Std
dev
67.1
% CV
19
1 CRS
requirement under consideration for a FMVSS No. 213 side impact test.
2 Qualification for proposed Part 572.
3 Injury assessment for research and development (R&D) only.
The following discusses the sled test
results that relate to responses of
primary importance to the dummy’s use
in side impact, i.e., primarily
measurements under consideration for
use in the FMVSS No. 213 side impact
test, and measurements that would
serve as Part 572 qualification targets.
Other measurements commonly
examined in research efforts are also
discussed below.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Head Acceleration and HIC15
As seen in Table 4, head acceleration
and HIC15 both displayed
‘‘EXCELLENT’’ repeatability and
reproducibility. Since these responses
are being considered as injury criteria
for our CRS side impact requirements,
we believe it is very important for these
responses to exhibit a high degree of
repeatability. It is notable that the
average HIC15 value was 704. This
value exceeds the IARVs under
consideration for our CRS requirements,
thus demonstrating that the dummy has
very good R&R up to and beyond the
expected pass/fail limit.
Thorax Deflection
Thorax deflection (labeled ‘‘Thorax YDisp’’ in Table 4), as measured by the
IR–TRACC, also displayed
‘‘EXCELLENT’’ reproducibility when
the responses of both dummies were
combined. The average measurement of
34 mm exceeds the IARVs under
consideration for our CRS requirements,
which attests to the reliable
performance of the dummy at pass/fail
limits.
We note that for dummy serial
number 007, the thorax y-displacement
is only ‘‘MARGINAL.’’ Closer inspection
of the lateral thorax displacement data
indicates that the response for one of the
tests was quite different than that of the
previous four tests. Our review of the
pre-test positioning data revealed that in
test 5, the dummy’s elbow location
relative to other body landmarks was
farthest away from the average location.
We believe that the elbow position
relative to the dummy’s torso played a
critical role in the amount of subsequent
lateral thorax displacement. Because
these data show an apparent sensitivity
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
to elbow positioning, the agency has
developed a procedure to position the
elbow at a specific angle relative to the
thorax.
Neck Y-Force and X-Moment
Neck Y-force and X-moment
responses exhibited ‘‘GOOD’’ and
‘‘MARGINAL’’ reproducibility,
respectively. A closer inspection of the
data indicates that the peak neck force
in one of the tests for dummy serial
number 006 was about 40 percent lower
than the other four tests, for reasons that
could not be determined by the test
technicians. If test 3 were removed from
the dataset, the repeatability of dummy
006 for neck X-moment becomes
‘‘EXCELLENT’’ and the overall
reproducibility becomes ‘‘GOOD.’’
Shoulder Y-Displacement
The shoulder displacement, as
measured by the Q3s’s internal string
potentiometer, also displayed
‘‘EXCELLENT’’ repeatability in both
dummies as well as in its overall
reproducibility when the responses of
both dummies are combined. Although
there is no IARV associated with
shoulder displacement, the average
measurement of 24 mm is fairly high in
comparison to the values obtained in
research tests from other tested CRSs.
Again, this attests to the good
performance of the dummy in
conditions beyond those to which the
ATD will typically be exposed in an
FMVSS No. 213 compliance test.
Upper Spine Acceleration
The overall reproducibility of both
dummies combined was ‘‘GOOD,’’
although the upper spine resultant
acceleration for dummy 007 displayed
‘‘POOR’’ repeatability. However, as with
the lateral thorax displacement
responses, the upper spine acceleration
for test 5 of dummy 007 was anomalous
as compared to the previous four tests.
We believe that this result is related to
the issue of arm position. We note that
if test 5 were removed from the dataset,
the ‘‘POOR’’ repeatability of dummy 007
for upper spine acceleration becomes
‘‘EXCELLENT’’ and the overall
PO 00000
Frm 00010
Fmt 4701
Sfmt 4702
reproducibility also becomes
‘‘EXCELLENT.’’
Pelvis Resultant-Acceleration, Lumbar
Y-Force, and Pubic Y-Force
Poor repeatability was observed in the
pelvic and lumbar responses. Pelvis
resultant acceleration response curves
revealed a sharp spike in the data
around 90 ms. These spikes obscured
the true data peaks, which occurred
around 85 ms, and therefore present a
negative effect on the repeatability
analysis. A similar spike, of lesser
magnitude, was evident in the lumbar
Y-force responses, also around the 90
ms mark of the event.
The source of the data spikes were
subsequently determined by NHTSA to
emanate from ‘‘knee knock.’’ The
dummy’s knees are hard plastic
components, and they contacted each
other precisely at the instant that the
spikes occurred in the pelvis
acceleration and lumbar Y-force
channels. This condition has since been
mitigated in the final Q3s design which
incorporates a padded covering over the
medial aspect of the knees to dampen
the force of impact.
The repeatability of the pubic Y-force
measurement was also shown to be
‘‘POOR.’’ This rating is not attributed to
the knee knock condition. Rather, pubic
Y-force appears to be a measurement
that is highly sensitive to any variation
in the test conditions. Nonetheless,
variations in pubic Y-force do not
appear to affect the dummy’s head
acceleration and thorax Y-displacement
(the IARVs we are exploring for the
FMVSS No. 213 side impact test under
consideration), which exhibited low
variability despite the scatter in pubic
force.
Supplemental Tests
In consideration of the ‘‘MARGINAL’’
performance observed for some of the
responses in the previous sled test
series, we ran another series of Cozy
Cline tests with the final version of the
Q3s. The final Q3s incorporated the
aforementioned pads on the medial
surfaces of the knees as well as a
simplified design of the neck center
cable. The older cable design was
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
thought to contribute to the nonuniformity observed in the earlier sled
tests. Additionally, we added a padded
door panel and positioned the arm at 25
degrees to be more consistent with what
is under consideration for the proposed
side impact test protocol.
The results for this supplemental test
series are shown in Table 5. As
compared to the previous set of tests
shown in Table 4, the supplemental
series demonstrate improved
repeatability in measurements of
shoulder and thorax deflection, neck
loads, and pelvis acceleration. These
improvements are directly related to a
new arm positioning protocol, the
69953
revised neck center cable, and the
elimination of knee knock, respectively.
Pubic force repeatability was again
rated as ‘‘POOR.’’ Since the revisions to
the dummy and test protocol were not
aimed at improving this measure, the
‘‘POOR’’ rating was not unexpected.
TABLE 5—SUMMARY OF SUPPLEMENTAL SLED TEST RESPONSES FOR SELECT CHANNELS
Dummy S/N 004
Used for:
Parameter
Avg
FMVSS 1 ..............................................................
P572 2 & FMVSS 1 ..............................................
Part 572 2 ............................................................
R&D 3 ..................................................................
Part 572 2 ............................................................
Part 572 2 ............................................................
R&D 3 ..................................................................
R&D 3 ..................................................................
R&D 3 ..................................................................
Part 572 2 ............................................................
HIC15 .................................................................
Thorax Y-Disp, mm ............................................
Head Res-Accel, g .............................................
Neck Y-force, N ..................................................
Neck X-Moment, Nm ..........................................
Shoulder Y-Disp, mm .........................................
Up spine Res-Accel, g .......................................
Lumbar Y-Force, N ............................................
Pelvis Res-Accel, g ............................................
Pubic Y-Force, N ................................................
795
17.8
110
630
28.0
24.3
129
765
97.1
557
Std dev
% CV
22.2
0.7
3.6
42
1.9
0.5
6.8
69
8.5
118
3
4
3
7
7
2
5
9
9
21
1 CRS
requirement under consideration for a FMVSS No. 213 side impact test.
for proposed Part 572.
3 Injury assessment for research and development (R&D) only.
2 Qualification
tkelley on DSK3SPTVN1PROD with PROPOSALS2
b. R&R in Component Qualification
Tests
Test dummies specified in 49 CFR
Part 572 are subjected to a series of
qualification tests to ensure that their
components are functioning properly.
The qualification tests proposed for the
Q3s are discussed further in a later
section. We have proposed qualification
tests for the dummy’s head, neck,
shoulder, thorax, lumbar, and pelvis,
assessing 35 response mechanisms for
the dummy.
We tested NHTSA’s four Q3s units to
the proposed qualification tests,
assessing among other matters the
performance of the units when tested to
the qualification tests, and the
repeatability and reproducibility of the
dummies. The findings are discussed in
the technical report, ‘‘Evaluation of the
Q3s Three Year-Old Child Side Impact
Dummy: Repeatability, Reproducibility,
and Durability,’’ supra.
R&R in the component qualification
tests were assessed by testing the four
Q3s dummies, all conforming to the
latest available revision level. Tests
were run for both right and left side
impacts. Average, standard deviation,
and coefficient of variation were
computed for each required
measurement parameter of each
qualification procedure. We used the
same guidelines to rate R&R as was used
previously in our R&R evaluation using
sled tests (see Table 3, supra).
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Head Drop Tests
Head qualification consisted of two
test components: Frontal and lateral
head drops. The frontal head drop was
conducted from a height of 376 mm,
while the lateral head drop was
conducted at 200 mm.
Four Q3s dummy heads were each
subjected to six frontal head drops, five
left-side lateral drops, and five rightside lateral drops. The responses are
summarized in Table 6 for frontal drops
and in Table 7 with left- and right-side
tests combined. Each individual head
was rated as having ‘‘EXCELLENT’’
repeatability in both the frontal and
lateral modes. When combining the
responses, the reproducibility of all four
heads was also rated as ‘‘EXCELLENT’’
in both the frontal and lateral test
modes.
TABLE 6—SUMMARY OF FRONTAL
HEAD DROP RESPONSES
Resultant
accel (g)
Dummy S/N
004 ................
006 ................
007 ................
008 ................
All ..................
PO 00000
Frm 00011
avg ..............
stdev ...........
%CV ............
avg ..............
stdev ...........
%CV ............
avg ..............
stdev ...........
%CV ............
avg ..............
stdev ...........
%CV ............
avg ..............
Fmt 4701
Sfmt 4702
273.0
3.86
1.41
276.5
2.48
0.90
282.0
4.35
1.54
263.5
5.12
1.94
273.8
TABLE 6—SUMMARY OF FRONTAL
HEAD DROP RESPONSES—Continued
Resultant
accel (g)
Dummy S/N
stdev ...........
%CV ............
7.68
2.80
TABLE 7—SUMMARY OF LATERAL
HEAD DROP RESPONSES
Dummy S/N
Orientation
L&R
004 ................
Avg ..............
Stdev ...........
%CV ............
Avg ..............
Stdev ...........
%CV ............
Avg ..............
Stdev ...........
%CV ............
avg ..............
stdev ...........
%CV ............
avg ..............
stdev ...........
%CV ............
006 ................
007 ................
008 ................
All ..................
Resultant
accel (g)
131.3
3.50
2.67
124.7
3.64
2.92
127.1
3.92
3.08
123.2
4.08
3.31
126.6
4.78
3.78
Neck Pendulum Tests
Flexion Tests. The two flexion tests
utilized the Part 572 neck pendulum
and a headform designed to mimic the
inertial properties of the head (Part 572,
Subpart E, Figure 22). The frontal
flexion test was at a 4.7 m/s impact
speed and the lateral test was at a 3.8
m/s speed. Both tests prescribed a
deceleration pulse. For the frontal
E:\FR\FM\21NOP2.SGM
21NOP2
69954
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
flexion tests, four Q3s dummy necks
were subjected to five tests. For lateral
flexion, each of the four necks was
subjected to five left-side tests and five
right-side tests.
The responses are summarized in
Table 8 (frontal flexion) and Table 9
(lateral flexion). For the frontal flexion
and lateral flexion tests, each individual
neck provided ‘‘EXCELLENT’’
repeatability for all criteria considered.
Reproducibility was also ‘‘EXCELLENT’’
for all four necks combined.
Neck Torsion. During CRS testing, the
Q3s neck may flex with varying degrees
of neck twist. We have therefore
developed a procedure to assure that the
neck is repeatable under twist. The new
neck torsion test uses a special test
fixture attached to the Part 572
pendulum, which imparts a pure torsion
moment to the isolated neck. The test
specifies a 3.6 m/s impact speed with a
defined deceleration pulse. Each of the
four Q3s dummy necks was subjected to
five left-side tests and five right-side
tests. The responses are summarized in
Table 10 with left- and right-side tests
combined. Each individual neck
provided ‘‘EXCELLENT’’ repeatability
for all criteria considered.
Reproducibility was also ‘‘EXCELLENT’’
for all four necks combined.
TABLE 8—SUMMARY OF FRONTAL FLEXION NECK PENDULUM TEST RESPONSES
Max angle
Dummy S/N
004 ..................................
006 ..................................
007 ..................................
008 ..................................
All ....................................
angle
deg
Avg ................................
stdev .............................
%CV ..............................
Avg ................................
stdev .............................
%CV ..............................
Avg ................................
stdev .............................
%CV ..............................
Avg ................................
stdev .............................
%CV ..............................
Avg ................................
stdev .............................
%CV ..............................
Peak Y-moment
time
ms
77.1
0.42
0.55
77.5
0.74
0.96
74.3
0.79
1.07
74.8
0.69
0.92
76.1
1.77
2.33
moment
N-m
58.5
0.62
1.06
59.3
0.84
1.42
58.3
0.70
1.20
57.9
0.65
1.12
58.7
1.12
1.90
Head rotation
decay time, ms
time
ms
47.1
0.63
1.35
46.0
1.10
2.40
46.8
0.71
1.51
46.9
1.90
4.04
46.4
1.50
3.23
54.3
1.02
1.88
56.1
1.89
3.38
55.7
1.47
2.64
54.2
1.10
2.03
55.5
2.00
3.61
52.2
0.10
0.20
52.2
0.20
0.38
51.3
0.17
0.34
51.2
0.23
0.45
51.7
0.48
0.93
TABLE 9—SUMMARY OF LATERAL FLEXION NECK PENDULUM TEST RESPONSES
Max angle
Dummy S/N
Orientation
L&R
004 ..................................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
006 ..................................
007 ..................................
008 ..................................
All ....................................
angle
deg
Peak X-moment
time
ms
83.3
0.53
0.63
85.2
0.32
0.37
81.0
0.44
0.55
81.7
0.73
0.89
82.8
1.69
2.04
moment
N-m
68.8
0.60
0.87
69.9
0.64
0.91
68.0
0.79
1.16
67.7
0.56
0.82
68.6
1.08
1.57
Head rotation
decay time, ms
time
ms
28.4
1.48
5.23
28.8
0.82
2.84
27.7
0.59
2.14
27.9
0.71
2.53
28.2
1.05
3.72
69.5
0.78
1.13
70.6
0.55
0.77
69.4
0.90
1.29
68.8
0.70
1.02
69.6
0.98
1.41
66.6
0.53
0.79
66.8
0.68
1.01
65.5
0.60
0.92
65.8
0.87
1.32
66.2
0.86
1.30
TABLE 10—SUMMARY OF TORSIONAL NECK PENDULUM TEST RESPONSES
Max angle
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Dummy S/N
Orientation
L&R
004 ..................................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
006 ..................................
007 ..................................
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
PO 00000
angle
deg
Peak Z-moment
time
ms
84.9
0.39
0.46
89.7
0.53
0.59
80.7
1.22
1.51
Frm 00012
Fmt 4701
moment
N-m
102.3
0.51
0.50
108.4
0.52
0.48
98.7
0.60
0.61
Sfmt 4702
time
ms
9.0
0.03
0.28
8.3
0.07
0.84
9.2
0.31
3.35
E:\FR\FM\21NOP2.SGM
21NOP2
96.2
0.82
0.85
102.1
2.03
1.99
90.8
1.39
1.53
Head rotation
decay time, ms
93.8
0.64
0.68
99.0
0.51
0.52
89.8
1.05
1.17
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
69955
TABLE 10—SUMMARY OF TORSIONAL NECK PENDULUM TEST RESPONSES—Continued
Max angle
Dummy S/N
Orientation
L&R
008 ..................................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
All ....................................
Shoulder Impact
This test assures that the shoulder
acts uniformly in the way it deforms
under load and distributes the load
under a direct lateral impact, thus
helping to assure that whole-body
kinematics of the ATD are consistent.
angle
deg
Peak Z-moment
time
ms
81.3
1.50
1.85
84.2
3.71
4.40
moment
N-m
99.3
0.72
0.72
102.2
3.89
3.80
Shoulder tests consisted of a lateral
impact to the shoulder using a 3.8 kg
probe at an impact speed of 3.6 m/s.
Each of the four Q3s dummies was
impacted five times on both their left
and right shoulders. The responses are
summarized in Table 11 with left- and
Head rotation
decay time, ms
time
ms
9.0
0.08
0.84
8.9
0.37
4.21
91.9
0.78
0.85
95.2
4.64
4.87
90.9
0.77
0.84
93.4
3.62
3.88
right-side tests combined. The shoulder
responses for each individual dummy
were rated as having ‘‘EXCELLENT’’
repeatability. The reproducibility of
shoulder responses for all four dummies
combined was also rated as
‘‘EXCELLENT.’’
TABLE 11—SUMMARY OF SHOULDER TEST RESPONSES
Shoulder
displacement
(mm)
Dummy S/N
Orientation
L&R
004 ..............................................................................
Avg .............................................................................
Stdev ..........................................................................
%CV ...........................................................................
Avg .............................................................................
Stdev ..........................................................................
%CV ...........................................................................
Avg .............................................................................
Stdev ..........................................................................
%CV ...........................................................................
Avg .............................................................................
Stdev ..........................................................................
%CV ...........................................................................
Avg .............................................................................
Stdev ..........................................................................
%CV ...........................................................................
006 ..............................................................................
007 ..............................................................................
008 ..............................................................................
All ................................................................................
Thorax Impacts
The thorax qualification tests were
conducted two ways: Without arm
interaction (as in the SAE test) and with
the arm attached and down such that
the impact probe strikes the upper arm.
Both tests utilized a lateral impact with
a 3.8 kg probe.
In the ‘‘thorax without arm’’ test, the
arm was completely removed from the
dummy. The 3.8 kg test probe was
aligned with the thorax displacement
IR–TRACC and impacted the thorax
18.4
0.47
2.57
19.0
0.35
1.84
18.8
0.46
2.46
18.6
0.83
4.48
18.7
0.58
3.12
Probe force
(N)
1281.5
27.99
2.18
1270.3
12.91
1.02
1295.0
13.55
1.05
1280.1
10.75
0.84
1281.7
19.16
1.50
laterally at a speed of 3.3 m/s. Each of
the agency’s four dummies was
impacted five times on both the left and
right sides. Table 12 below provides a
summary of the responses with left- and
right-side tests combined.
TABLE 12—SUMMARY OF THORAX WITHOUT ARM QUALIFICATION TEST RESPONSES
Thorax
displacement
(mm)
Dummy S/N
Orientation
L&R
004 ..............................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
006 ..............................................................................
007 ..............................................................................
008 ..............................................................................
All ................................................................................
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
PO 00000
Frm 00013
Fmt 4701
Sfmt 4702
E:\FR\FM\21NOP2.SGM
21NOP2
27.3
0.45
1.66
28.6
0.77
2.69
28.1
0.19
0.67
26.3
0.19
0.70
27.6
Probe force
(N)
705.2
15.52
2.20
665.1
27.83
4.18
692.1
22.92
3.31
710.9
19.51
2.74
693.3
69956
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE 12—SUMMARY OF THORAX WITHOUT ARM QUALIFICATION TEST RESPONSES—Continued
Thorax
displacement
(mm)
Orientation
L&R
Dummy S/N
stdev ...........................................................................
%CV ...........................................................................
For the ‘‘arm attached’’ test, the upper
arm was positioned vertically and
aligned with the dummy’s thorax. The
lower arm was positioned to make a 90
degree angle with the upper arm. The
impact speed of the probe was 5.0 m/
s.
Each of the four test dummies was
impacted five times on both the left and
right sides. Table 13 provides a
1.00
3.63
Probe force
(N)
27.63
3.99
summary of the test results with leftand right-side tests combined.
TABLE 13—SUMMARY OF THORAX WITH ARM ATTACHED QUALIFICATION TEST RESPONSES
Thorax
displacement
(mm)
Dummy S/N
Orientation
L&R
004 ..............................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
006 ..............................................................................
007 ..............................................................................
008 ..............................................................................
All ................................................................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
For thorax impacts both with and
without the arm, each dummy was rated
as having ‘‘EXCELLENT’’ repeatability.
Furthermore, the responses of all four
dummies combined produced a rating of
‘‘EXCELLENT’’ reproducibility.
Note that the peak probe force was
taken after 5 ms to separate the probe’s
initial inertial response during arm
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
contact from the probe’s response due to
its interaction with the thorax. The
typical probe force response curve
exhibited dual peaks of nearly equal
magnitude, with the first peak occurring
upon initial impact of the probe with
the arm and the second peak occurring
as the arm loaded the thorax (see Figure
PO 00000
Frm 00014
Fmt 4701
Sfmt 4702
26.0
0.63
2.41
26.3
0.55
2.09
25.9
0.37
1.44
25.2
0.48
1.92
25.9
0.64
2.46
Peak probe
force after 5 ms
(N)
1527.5
28.58
1.87
1567.1
46.47
2.97
1512.7
60.32
3.99
1542.3
45.96
2.98
1537.4
49.28
3.21
1 below). Analysis of the response
curves indicated that the first peak
typically occurred before 5 ms, and the
second peak occurred after 5 ms.
Because the second peak is more closely
related to the resistive force of the
thorax, we concluded that the first peak
was not determinative.
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
Lumbar Pendulum Tests
Lumbar testing consisted of two types
of pendulum tests: A frontal test and a
lateral test. For both tests, the lumbar
spine element containing the flexible
column was removed from the dummy
similar to the neck qualification tests.
Lumbar tests were conducted using the
same Part 572 neck pendulum and the
headform device utilized in the neck
qualification tests. Frontal and lateral
tests were conducted at an impact speed
of 4.4 m/s.
Five frontal tests were carried out on
lumbar elements from each of the four
test dummies. For the lateral tests, five
were conducted on the left side and five
on the right side. The results are
69957
summarized in Table 14 (frontal) and
Table 15 (lateral) with left- and rightside tests combined. The repeatability of
each lumbar element was rated as either
‘‘EXCELLENT’’ or ‘‘GOOD’’ for all test
measurements. The reproducibility of
responses of all four lumbar elements
combined was ‘‘EXCELLENT’’ for all
measurements.
TABLE 14—SUMMARY OF FRONTAL LUMBAR PENDULUM TEST RESPONSES
004 ..................................
006 ..................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
007 ..................................
008 ..................................
All ....................................
VerDate Mar<15>2010
angle
deg
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
17:18 Nov 20, 2013
Jkt 232001
PO 00000
Peak Y-moment
time
ms
52.8
1.05
1.99
52.5
1.79
3.40
53.4
1.41
2.65
51.4
1.13
2.19
52.5
1.47
2.79
Frm 00015
Fmt 4701
moment
N-m
55.1
0.89
1.61
54.8
0.81
1.48
56.1
0.89
1.58
54.4
0.71
1.31
55.1
0.99
1.79
Sfmt 4702
84.2
1.46
1.74
87.1
0.85
0.97
84.2
1.38
1.64
88.5
2.21
2.49
86.0
2.39
2.78
E:\FR\FM\21NOP2.SGM
Head rotation
decay time, ms
time
ms
21NOP2
51.2
3.75
7.31
51.4
2.81
5.48
51.4
3.02
5.88
50.8
2.06
4.06
51.2
2.74
5.35
53.8
0.34
0.63
52.7
0.61
1.15
53.9
0.68
1.26
52.3
0.27
0.52
53.2
0.85
1.60
ep21no13.001
Max angle
Dummy S/N
69958
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE 15—SUMMARY OF LATERAL LUMBAR PENDULUM TEST RESPONSES
Max angle
Dummy S/N
Orientation
L&R
004 ..................................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
avg ................................
stdev .............................
%CV ..............................
006 ..................................
007 ..................................
008 ..................................
All ....................................
Pelvis Impact
A lateral impact with the 3.8 kg probe
at 4.0 m/s was used to test the pelvis.
Repeat tests were conducted according
to the test procedures described in the
technical report, ‘‘Qualification
Procedures for the Q3s Child Side
Impact Crash Test Dummy,’’ supra. For
each dummy in the evaluation, NHTSA
conducted five impacts to both the left
and right side of the pelvis. A summary
angle
deg
Peak X-moment
time
ms
52.7
1.58
3.01
53.5
2.05
3.82
51.7
1.75
3.39
54.2
1.51
2.79
53.0
1.93
3.63
moment
N-m
54.3
1.47
2.71
54.6
1.30
2.38
54.5
1.13
2.07
55.6
1.04
1.88
54.7
1.29
2.36
of the test results can be found in Table
16 with left- and right-side tests
combined.
The repeatability of each individual
dummy’s response was rated as
‘‘EXCELLENT’’ except for the peak
pubic force response of dummy serial
number 006, which was rated as
‘‘GOOD.’’ For this particular dummy,
the pubic force was about 75 N higher
for right side impacts than left side
Head rotation
decay time, ms
time
ms
86.2
2.23
2.59
89.2
3.01
3.38
88.4
2.57
2.91
86.7
3.26
3.76
87.6
2.96
3.38
50.2
3.75
7.47
51.1
2.38
4.67
52.7
2.74
5.20
51.2
2.29
4.47
51.3
2.89
5.63
53.4
0.88
1.66
52.8
0.83
1.56
54.8
2.17
3.96
51.6
2.07
4.01
53.1
1.94
3.66
impacts. For the other three dummies,
the difference was only 50–60 N.
Despite the differences, repeatability—
when assessed by combining right and
left impacts—only fell out of the
‘‘EXCELLENT’’ category for dummy
serial number 006. When left and right
impacts for all dummies were
combined, reproducibility was rated as
‘‘EXCELLENT’’ for both the peak pubic
force and the peak probe force.
TABLE 16—SUMMARY OF PELVIS QUALIFICATION TEST RESPONSES
Dummy S/N
Orientation
L&R
004 ..............................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
avg ..............................................................................
stdev ...........................................................................
%CV ...........................................................................
006 ..............................................................................
007 ..............................................................................
008 ..............................................................................
All ................................................................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
VI. Qualification Tests
This NPRM proposes a set of
qualification tests for the Q3s. In
general, Part 572 qualification tests
assess the components that play a key
role in the dummy’s performance in the
intended regulatory application. The
tests qualify the dummy as an objective
and suitable test device for the
assessment of occupant safety in
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
compliance tests specified in Federal
motor vehicle safety standards, and for
other testing purposes. Performance
within these corridors assures that the
dummy is capable of responding
properly in a compliance or research
test, while performance outside of these
corridors indicates the need for
adjustment, repair or replacement.
PO 00000
Frm 00016
Fmt 4701
Sfmt 4702
Pubic force
(N)
745.3
31.33
4.20
782.3
41.07
5.25
801.0
29.31
3.66
822.3
27.02
3.29
787.7
42.48
5.39
Probe force
(N)
1651.0
22.78
1.38
1698.9
20.68
1.22
1679.1
25.59
1.52
1738.1
20.69
1.19
1691.8
38.71
2.29
a. Overview of Proposed Corridors
Proposed qualification requirements
for the Q3s are shown in Table 16.
NHTSA has published a technical
document, ‘‘Qualification Procedures
for the Q3s Child Side Impact Crash
Test Dummy (NHTSA, 2013),’’
describing the equipment, test set-ups
and procedures. A copy of the report
has been placed in the docket.
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
69959
TABLE 17—PROPOSED Q3S QUALIFICATION REQUIREMENTS
Test
Measurement
Head—Frontal ...........
Head—Lateral ...........
Neck—Flexion ...........
Resultant acceleration .....................................................................
Resultant acceleration .....................................................................
Maximum rotation ............................................................................
Time of max rotation ........................................................................
Peak moment (My) ..........................................................................
Time of peak My ..............................................................................
Decay time to 0 from peak angle ....................................................
Maximum rotation ............................................................................
Time of max rotation ........................................................................
Peak moment (Mx) ..........................................................................
Time of peak Mx ..............................................................................
Decay time to 0 from peak angle ....................................................
Maximum rotation ............................................................................
Time of max rotation ........................................................................
Peak moment (Mz) ..........................................................................
Time of peak Mz ..............................................................................
Decay time to 0 from peak angle ....................................................
Lateral displacement ........................................................................
Peak probe force .............................................................................
Lateral displacement ........................................................................
Peak probe force .............................................................................
Lateral displacement ........................................................................
Peak probe force .............................................................................
Maximum rotation ............................................................................
Time of max rotation ........................................................................
Peak moment (My) ..........................................................................
Time of peak My ..............................................................................
Decay time to 0 from peak angle ....................................................
Maximum rotation ............................................................................
Time of max rotation ........................................................................
Peak moment (Mx) ..........................................................................
Time of peak Mx ..............................................................................
Decay time to 0 from peak angle ....................................................
Peak pubic load ...............................................................................
Peak probe force .............................................................................
Neck—Lateral ............
Neck—Torsion ...........
Shoulder ....................
Thorax with Arm ........
Thorax without Arm ...
Lumbar—Flexion .......
Lumbar—Lateral ........
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Pelvis .........................
The bounds we have proposed for the
qualification targets (the corridors) are
wide enough to account for normal
variations in dummy and laboratory
differences, and narrow enough to
assure consistent and repeatable
measurements in compliance testing.
Our proposed bounds are based on tests
conducted at a single laboratory,
NHTSA’s Vehicle Research and Test
Center (VRTC). The data were collected
using four Q3s units. For each
measurement, performance targets were
derived using either ±3 standard
deviations from the mean or 10 percent
from the mean, whichever is narrower.
Upper and lower bounds were rounded
to the next whole number away from the
mean using three significant digits.
We recognize that from a probabilistic
standpoint, three standard deviations is
an unusually wide bound. A bound of
10 percent around a target is typical of
most Part 572 ATD qualifications. Our
reason for initially setting the bounds to
be wide for this NPRM stem from a
current lack of test data for the Q3s.28
28 For other Part 572 ATDs, we set qualification
bounds by examining data from multiple test labs,
several dummies, and dummies built by different
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Units
Given that all Q3s qualification data
were collected from a single laboratory
(VRTC), we could not factor into
account unknown variability associated
with different labs, operators, dummies,
and other allowable variances such as
temperature and humidity that may not
be present in our dataset. We will
continue to collect qualification data,
and we will examine all qualification
data provided to us by commenters. We
anticipate that when new qualification
data are combined with our current set
of data, in a final rule our bounds will
be narrowed as reasonably possible and
may be no greater than two standard
deviations.
b. Rationale for the Tests
The technical document cited earlier
in this preamble, ‘‘Evaluation of the Q3s
Three Year-Old Child Side Impact
Dummy, Repeatability, Reproducibility,
dummy manufacturers. For example, the
qualification bounds for the HIII–10C (the most
recent test dummy to be incorporated into part 572)
were derived from tests on about 30 different
dummies, with data supplied from about 10
different laboratories. On average, the bound widths
for the HIII–10C are about 10% of the mean, with
a low of 7.4% and a high of 16.3%.
PO 00000
Frm 00017
Fmt 4701
Sfmt 4702
Corridor
G
G
deg
msec
N-m
msec
msec
deg
msec
N-m
msec
msec
deg
msec
N-m
msec
msec
mm
kN
mm
kN
mm
N
deg
msec
N-m
msec
msec
deg
msec
N-m
msec
msec
N
kN
250–297
113–140
70–82
55–63
41–51
49–62
50–54
77–88
65–72
25–32
66–73
63–69
75–93
91–113
8–10
85–105
84–103
16–21
1.24–1.35
23–28
1.38–1.69
24–31
620–770
48–57
52–59
78–94
46–57
50–56
47–59
50–59
78–97
46–57
47–59
700–870
1.57–1.81
and Durability,’’ discusses how the
agency’s four Q3s units conform to the
qualification requirements. This report
also discusses our rationale for the tests
and proposed response requirements
needed to qualify the Q3s. For each test,
the impact energy level and the
selection of the targeted measurements
were chosen by balancing multiple
criteria, as described below.
Dummy Functionality
For each test, certain dummy sensors
and signal characteristics (such as the
magnitude and timing) have been
specified as qualification targets. By
monitoring these sensors, the
qualification tests assure that the
dummy is functioning properly. Loose
or damaged dummy hardware is often
manifested in a signal that does not
conform to the qualification
requirements, thus alerting test
technicians that dummy maintenance
may be needed. Conformity also assures
that the sensors themselves are working
properly.
Test protocols are also designed to
properly demonstrate dummy
functionality by mirroring dummy
loading patterns seen in CRS sled tests
E:\FR\FM\21NOP2.SGM
21NOP2
69960
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
conducted in support of the FMVSS No.
213 side impact test under
consideration. For example, we have
observed the Q3s undergoing
asymmetric motion as the dummy
simultaneously moves forward and
laterally. In doing so, the motion of the
dummy is such that it may twist itself
around the edge of the CRS so that the
head may strike the door panel near its
forehead. The degree to which the
dummy wraps around the seat can vary
widely depending upon the design of
the CRS. Thus, we have included
separate frontal and lateral qualification
requirements for the head.
We have also included separate
requirements for the neck and lumbar
spine elements of the dummy, which
are flexible rubber components that
experience both frontal and lateral
flexion during a CRS test.
Additionally, a torsion test is
prescribed for the neck since the neck
also twists along its long axis to some
degree.
For the shoulder, thorax, and pelvis,
we believe that only pure lateral
qualification requirements are needed,
since almost all loads pass through their
lateral aspects even in cases where the
dummy twists within the CRS during
testing.
Assure Biofidelity
Many of the qualification test
protocols are very similar to the
dynamic tests used to assess biofidelity.
This helps to assure that a qualified
dummy is also a biofidelic dummy.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Sufficient Energy
The impact speeds and probe masses
have been selected to demonstrate that
the various body segments of the Q3s
are working properly at energy levels at
or near those associated with injury
thresholds. These include pass/fail
thresholds that we are considering for
the FMVSS No. 213 side impact test. For
measurements not associated with
IARVs, such as the neck torsion
requirement, the energy levels are
chosen to be consistent with high-end
responses observed in CRS testing. In
general, the energy level is chosen to
exercise the dummy but without
causing damage.
Proven Soundness of Part 572
To the extent possible, we have based
the proposed test protocols and devices
on qualification tests set forth for other
test dummies in Part 572. The
qualification tests have been proven
reliable and sound in qualifying
NHTSA’s other test dummies. Moreover,
using the same basic tests minimizes the
amount of new qualification equipment
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
needed by test laboratories that may
already have such equipment in place
for qualifying other ATDs.
c. New and Modified Part 572 Tests and
Equipment
This NPRM proposes only one new
test not found elsewhere in Part 572, a
method to assure the functionality of the
Q3s neck under torsion. This is a fairly
simple procedure added to assure that
the neck is repeatable under twist. The
test involves the use of a special test
fixture attached to the Part 572
pendulum which imparts a pure torsion
moment to the isolated neck.
Additionally, a few minor changes to
established Part 572 protocol and
equipment have been introduced to
improve the ease and consistency of the
qualification tests. The pendulum probe
used to qualify the Q3s is specified to
be 3.81 kg, which is about twice as large
as the 1.70 kg probe used for the HIII–
3C, Subpart P qualifications (Hybrid III
3-year-old child test dummy used for
frontal testing). This probe was chosen
to enable the same probe to be used for
all Q3s qualification tests that use a
probe. The heavier probe allows a range
of reasonable test speeds to be used to
attain the desired response level. Tests
speeds range from 3.6 m/s (shoulder
impact) up to 5.0 m/s (thorax with arm).
In contrast, the test speed for the thorax
test of the HIII–3C with the lighter probe
is 6.0 m/s.
We have also proposed a new test
instrument for the flexion tests of the
neck and the lumbar spine. These tests
measure relative rotation by means of
two angular rate sensors (ARSs). The
ARSs that we specify represent a
relatively new technology. For similar
tests with all other Part 572 dummies,
relative rotation is measured using a
system of rotary potentiometers and a
linking rod. Because the potentiometer
system is mounted off-axis, it creates an
asymmetry that can create problems
with a small dummy like the Q3s. We
are concerned that the added mass and
inertia of a potentiometer system can
introduce twisting of the head
simulator, which may affect the
accuracy of the measurements.
ARS units, on the other hand, are
lightweight and compact. They do not
require a connecting rod and they can
be mounted very near to the headform’s
axis of symmetry so that their
propensity to twist during a test due to
the added mass is greatly reduced.
Furthermore, throughout our testing of
the Q3s the angular rate sensors have
been observed to produce very accurate
measures of rotation. We tentatively
conclude that use of the ARS units in
PO 00000
Frm 00018
Fmt 4701
Sfmt 4702
this application would be an
improvement over potentiometers.
d. Proposed Test Specifications and
Performance Requirements
NHTSA proposes the following
performance specifications for the head
in drop tests, and for the neck, shoulder,
thorax, lumbar spine, and pelvis in
pendulum tests. Performance
requirements in the lateral direction
must be met by carrying out the tests in
the direction opposing the primary load
vector of the ensuing full scale test for
which the dummy is being qualified.
For example, if the dummy is to be used
in an impact to the left side of a CRS,
qualification tests on the left aspect of
the dummy’s head, neck, shoulder,
thorax, lumber spine, and pelvis are
carried out. The fore-aft performance
requirements for the head, neck, and
lumbar spine must be met for all impact
tests. That is, in addition to the lateral
tests, the fore-aft tests are conducted on
the ATD regardless of which side of the
CRS is tested.
Head Drop Tests
The correct kinematic response of the
head-neck system is of substantial
importance to quantify the protection
offered by CRSs in terms of head motion
and acceleration during an impact. This
test serves to assure the uniformity of
the impact response. Head qualification
consists of two test components: Frontal
and lateral head drops. The frontal head
drop is conducted from a height of 376
mm, while the lateral head drop is
conducted at 200 mm.
The head must respond with peak
resultant acceleration between: 250 g
and 297 g when dropped from 376 mm
height such that the forehead lands onto
a flat rigid surface; and between 113 g
and 140 g when dropped from a 200 mm
height such that the side of the head
lands onto a flat rigid surface.
Neck Pendulum Test
We believe that a repeatable
kinematic response of the head-neck
system is important to quantify the
protection offered by CRSs in terms of
limiting head excursion and head
acceleration in both a head impact and
a non-impact situation. Under the CRS
test protocol under consideration by the
agency, the primary kinematic motion of
the head is in the lateral direction, but
the head also twists and turns in other
directions to a lesser extent. Given the
importance of head motion, we believe
a full set of neck qualification
requirements is warranted to assure
uniformity. Therefore, our proposed
neck qualification consists of three test
components: Frontal flexion, lateral
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
For the ‘‘arm attached’’ test, the upper
arm is positioned vertically and aligned
with the dummy’s thorax. The lower
arm is positioned to make a 90 degree
angle with the upper arm. The loading
of the ribcage goes through the arm. The
impact speed of the probe is 5.0 m/s.
This test assures uniformity of the arm
in the way it absorbs energy and
interacts with the thorax under a direct
lateral impact.
The thorax exposed to a pendulum
impact:
• At 3.3 m/s, without arm, is to
exhibit a peak thorax deflection between
24 mm and 31 mm, and a peak
resistance force between 620 N and 770
N; and,
• at 5.0 m/s, with arm attached, is to
exhibit a peak thorax deflection between
23 mm and 28 mm, and a peak
resistance force between 1,380 N and
1,690 N occurring after 5 ms from time
zero.
As explained previously, the peak
probe force is taken after 5 ms to
separate the probe’s initial inertial
response during arm contact from its
response due to its interaction with the
thorax. The net effect of recording the
peak probe force after 5 ms is the
elimination of the first peak.
Shoulder Impact Test
Though injury assessment is not
generally associated with the shoulder,
the way the shoulder absorbs energy can
affect the overall kinematics of the
dummy. This test assures that the
shoulder acts uniformly in the way it
distributes the load under a direct
lateral impact.
The shoulder exposed to a pendulum
impact at 3.6 m/s is to exhibit a peak
shoulder deflection between 16 mm and
21 mm, and a peak resistance force
between 1,240 N and 1,350 N.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
flexion, and torsion neck pendulum
tests.
The neck would have to allow the
headform to articulate in pendulum
tests at:
• 4.7 m/s in frontal flexion, at
between 70 degrees and 82 degrees
occurring between 55 ms and 63 ms
from time zero and decaying back to the
zero angle between 50 ms and 54 ms
after the peak rotation; the value of the
maximum moment must be between 41
N-m and 51 N-m occurring between 49
ms and 62 ms from time zero,
• 3.8 m/s in lateral flexion, at
between 77 degrees and 88 degrees
occurring between 65 ms and 72 ms
from time zero and decaying back to the
zero angle between 63 ms and 69 ms
after the peak rotation; the value of the
maximum moment must be between 25
N-m and 32 N-m occurring between 66
ms and 73 ms from time zero, and
• 3.6 m/s in torsion, at between 75
degrees and 93 degrees occurring
between 91 ms and 113 ms from time
zero and decaying back to the zero angle
between 84 ms and 103 ms after the
peak rotation; the value of the maximum
moment must be between 8 N-m and 10
N-m occurring between 84 ms and 103
ms from time zero.
Lumbar Tests
Thorax Impact Tests
The thorax qualification tests are very
similar to the SAE test used to assess
lateral thorax biofidelity. For
qualification, however, the test is
conducted two ways: Without arm
interaction (as in the SAE test) and with
the arm attached such that the impact
probe strikes the upper arm. Both tests
utilize a lateral impact with a 3.8 kg
probe.
The thorax ‘‘without arm’’ test assures
uniformity of the thorax structure,
including its mount to the spine, and its
response to a direct impact in terms of
rib deflection. The arm is completely
removed from the dummy. The 3.8 kg
test probe is aligned with the thorax
displacement IR–TRACC and impacts
the thorax laterally at a speed of 3.3
m/s.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
The rubber lumbar column bends to
some extent during a CRS side impact
test. This bending might affect the
overall kinematics of the dummy,
including the excursion of the head. It
could also affect lateral loads and the
deflection of the thorax. We believe that
this rubber element can be a source of
variability, so we have included a
qualification test to assure the
uniformity and integrity of this
component.
Lumbar testing would consist of two
types of pendulum tests: A frontal test
and a lateral test. For both tests, the
lumbar spine element containing the
flexible column is removed from the
dummy, similar to the neck
qualification tests. Lumbar tests are
conducted using the same Part 572 neck
pendulum and headform device utilized
in the neck qualification tests. In the
case of lumbar qualification, the
headform is not intended to represent
the inertial properties of any particular
body region, but merely provides an
apparatus that helps to ensure a
repeatable test condition. The frontal
and lateral pendulum tests are
conducted at the same impact speed of
4.4 m/s and specify the same pendulum
impulse.
We propose that the lumbar spine
must allow the headform to articulate:
PO 00000
Frm 00019
Fmt 4701
Sfmt 4702
69961
• In frontal flexion, at not less than
between 48 degrees and 57 degrees
occurring between 52 ms and 59 ms
from time zero and decaying back to
zero angle between 50 ms and 56 ms
after the peak rotation; the value of the
maximum moment must be between 78
N-m and 94 N-m occurring between 46
ms and 57 ms from time zero; and,
• in lateral flexion, at not less than
between 47 degrees and 59 degrees
occurring between 50 ms and 59 ms
from time zero and decaying back to
zero angle between 47 ms and 59 ms
after the peak rotation; the value of the
maximum moment must be between 78
N-m and 97 N-m occurring between 46
ms and 57 ms from time zero.
Pelvis Impact
A lateral impact with the 3.8 kg probe
at 4.0 m/s is used to test the pelvis. This
test protocol is very similar to the SAE
biofidelity test. The pelvis exposed to a
pendulum impact at 4.0 m/s is to
exhibit a peak pubic load between 700
N and 870 N, and a peak force measured
by the pendulum between 1570 N and
1810 N.
Other
We have not included a qualification
test aimed specifically at the Q3s
abdomen. We tentatively believe that
any non-uniformity in stiffness due to
the absence of a qualification
requirement for the abdomen would
have an insignificant effect on the
overall kinematics of the dummy in a
side impact test. Also, the abdomen of
the Q3s is uninstrumented and is thus
not generally used to assess injury
potential in a side impact.
Nevertheless, comments are requested
on the need for a qualification test for
the abdomen. The abdomen is made of
a high density, compressible foam
material, whose compressive
characteristics can vary from one
abdomen to another and whose
properties can change with aging and
other factors. We request comments on
an abdominal test protocol similar to
that which we used to assess the
biofidelity of the Q3s abdomen.
VII. Durability
No durability problems arose with the
Q3s dummies in any of the sled tests or
component tests.
a. High-Energy Component Tests
We also conducted high-energy
component tests to assess durability and
no durability problems arose in those. In
these tests, we raised the kinetic energy
of the impact to levels that exposed the
dummy to loading conditions slightly
greater than those that might be
E:\FR\FM\21NOP2.SGM
21NOP2
69962
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
expected in the dummy’s regulatory
application. High-energy tests were
conducted for the head, neck, shoulder,
thorax (with and without arm), lumbar,
and pelvis. As discussed below, we
found no damage to the dummy’s
structural components or
instrumentation.
High-Energy Head Drop Tests
We performed frontal and lateral head
drop tests using the qualification test
setup procedures, except the drop
heights were increased to achieve
kinetic energy increases of 10 percent,
20 percent, and 30 percent, as compared
to the standard qualification test.
Frontal head drop responses are
summarized in Table 18. The peak
resultant head acceleration at 30 percent
increased energy was 318.5 g. This
impact resulted in a HIC15 value of
1732.5, which is well above the
proposed injury criterion limit of 700
and demonstrates the severity of the
test. Post-test inspection of the head
revealed no structural damage to the
synthetic skull material or to the vinyl
skin.
Lateral head drop responses are
summarized in Table 19. For the most
severe condition, the peak resultant
head acceleration was 146.6 g. No
structural damage of the head was
observed in the post-test inspection of
the head assembly.
TABLE 18—HIGH-ENERGY FRONTAL HEAD DROP TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
Baseline .......................................................................................................................................
1 ...................................................................................................................................................
2 ...................................................................................................................................................
3 ...................................................................................................................................................
Drop height
(mm)
0
10
20
30
376
414
451
489
Peak
resultant
accel
(g)
265.5
284.6
304.4
318.5
TABLE 19—HIGH-ENERGY LATERAL HEAD DROP TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
Baseline .......................................................................................................................................
1 ...................................................................................................................................................
2 ...................................................................................................................................................
3 ...................................................................................................................................................
High-Energy Neck Pendulum Tests
We conducted frontal, lateral, and
torsional neck pendulum tests at the
increased impact speeds. Tests were
conducted according to the qualification
procedures, except for the increase in
impact speeds.
Frontal Flexion Tests. The results of
the high-energy frontal neck flexion
tests are summarized in Table 20. Three
repeat tests were run at 5.5 m/s. This
speed represents a 34 percent increase
in energy over the qualification speed.
We chose this condition because it is
consistent with the test protocol used to
qualify the HIII–3C (a frontal impact
dummy). We found no signs of damage
or unusual wear to the Q3s neck or neck
cable at the elevated speed. The
response curves were smooth,
indicating that no unusual contact
occurred during the tests. The tests also
demonstrate that the Q3s neck would be
repeatable if the dummy were used in
a frontal impact mode.
Lateral Flexion Tests. The results of
the high-energy lateral neck flexion tests
are summarized in Table 21.
Drop height
(mm)
0
10
20
30
200
220
240
260
Peak
resultant
accel
(g)
121.5
127.3
141.6
146.6
Incremental tests were run at impact
speeds needed to achieve increases in
kinetic energy of 10 percent, 20 percent,
and 30 percent. In all cases, the
response signals were smooth with no
indication of damage.
Torsion Tests. The high-energy neck
torsion tests were also run at impact
speeds needed to achieve energy
increases of 10 percent, 20 percent, and
30 percent. The responses are
summarized in Table 22. In all cases,
the response signals were smooth with
no indication of damage.
TABLE 20—FRONTAL FLEXION NECK PENDULUM TEST RESPONSES
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Test No.
Energy
increase
(nominal)
(percent)
Baseline .......................
1 ...................................
2 ...................................
3 ...................................
VerDate Mar<15>2010
17:18 Nov 20, 2013
Max angle
Impact
speed, m/s
0
34
34
34
Jkt 232001
4.7
5.5
5.5
5.5
PO 00000
Frm 00020
angle deg
time ms
74.0
78.8
80.1
79.4
Fmt 4701
Peak Y-moment
Sfmt 4702
moment
N-m
58.2
55.9
55.4
57.0
E:\FR\FM\21NOP2.SGM
44.9
62.3
66.0
63.2
21NOP2
time ms
54.1
53.0
52.7
53.2
Head
rotation
decay
time, m/s
51.5
48.0
47.7
47.6
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
69963
TABLE 21—LATERAL FLEXION NECK PENDULUM TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
baseline ........................
1 ...................................
2 ...................................
3 ...................................
Max angle
Impact
speed, m/s
0
10
20
30
angle deg
3.8
4.0
4.2
4.3
Peak Y-moment
moment
N-m
time ms
80.9
82.3
85.1
86.8
68.7
68.9
67.2
66.8
Head
rotation
decay
time, m/s
time ms
26.9
27.1
31.9
34.3
70.2
70.1
66.8
66.3
64.8
65.5
63.2
62.3
TABLE 22—NECK TORSION PENDULUM TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
baseline ....................................................
1 ...............................................................
2 ...............................................................
3 ...............................................................
Impact
speed
angle
0
10
20
30
High-Energy Shoulder Impact Tests
The agency conducted shoulder
impacts according to the qualification
test setup procedures, except the impact
speeds were increased to achieve
increases in kinetic energy of
3.6
3.8
3.9
4.1
time
moment
time
Head
rotation
decay time
Deg
m/s
Max angle
Peak Z-Moment
Ms
N-m
ms
ms
80.9
83.3
83.8
87.4
99.5
102.9
101.5
103.1
approximately 10 percent, 20 percent,
and 30 percent as compared to the
qualification test. Table 23 provides a
summary of the responses for the highenergy shoulder impact tests. At the 30
percent increased energy level, the peak
lateral shoulder deflection was 20.4 mm
9.35
9.35
9.40
9.73
92.1
95.5
95.0
96.9
88.7
91.7
91.2
91.0
and the response curve was smooth,
indicating that the shoulder string pot
did not reach its maximum allowable
stroke. The peak probe force was 1450
N. Post-test inspections revealed no
structural damage to the dummy or
instrumentation.
TABLE 23—HIGH-ENERGY SHOULDER IMPACT TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
baseline ............................................................................................
1 .......................................................................................................
2 .......................................................................................................
3 .......................................................................................................
High-Energy Thorax Impact Tests
We conducted high-energy thorax
impact tests with and without the arm.
We followed the set-up procedures used
in the qualification tests, except we
increased the probe impact speeds to
supply a corresponding increase in the
kinetic energy.
For the ‘‘with arm’’ tests, we
conducted one impact at 20 percent
increased kinetic energy and two at a 30
percent increase. Table 24 summarizes
the responses for the high-energy thorax
with arm impacts. The highest lateral
thorax displacement was 28.7 mm and
the response curve was smooth. Posttest inspections demonstrated that no
damage occurred to any portion of the
dummy’s torso.
For the thorax ‘‘without arm’’ test
condition (Table 25), because thorax
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Impact speed
(m/s)
0.0
10
20
30
durability was a concern with earlier
versions of the Q3s, we conducted tests
at higher severity levels to provide a
rigorous assessment of the durability of
the thorax. For the thorax ‘‘without
arm’’ test condition, we conducted an
impact at 50 percent increased kinetic
energy and another impact at a 70
percent increase. No structural damage
was observed during post-test
inspections of the dummy’s thorax and
IR–TRACC displacement transducer.
In addition, for the thorax ‘‘without
arm’’ test condition, we conducted tests
at increased severity levels to assess
further the durability of the IR–TRACC
device. The maximum allowable lateral
thorax displacement before damage
occurs to the IR–TRACC displacement
measurement device is approximately
40 mm. Considering this physical
PO 00000
Frm 00021
Fmt 4701
Sfmt 4702
Shoulder
displacement
(mm)
3.6
3.8
4.0
4.1
17.6
19.7
20.1
20.4
Probe force
(N)
1269
1348
1443
1450
limitation, we increased the probe
impact speed until the lateral
displacement approached 38 mm. We
found that the impact speed
corresponding to roughly 38 mm of
displacement was 4.4 m/s
(approximately an 80 percent increase
in kinetic energy). Accordingly, we
conducted two additional impact tests
at that speed. For the three tests
conducted at 80 percent increased
kinetic energy, the lateral thorax
displacement ranged from 37.1–37.9
mm and the response curves were
smooth, indicating that the transducer
did not exceed its maximum allowable
stroke. No structural damage was
observed during post-test inspections of
the dummy’s thorax and IR–TRACC
displacement transducer.
E:\FR\FM\21NOP2.SGM
21NOP2
69964
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE 24—HIGH-ENERGY THORAX WITH ARM IMPACT TEST RESPONSES
Test No.
Energy
increase
(nominal)
(percent)
Impact speed
(m/s)
baseline ............................................................................................
1 .......................................................................................................
2 .......................................................................................................
3 .......................................................................................................
0
20
30
............................
5.0
5.5
5.7
............................
Thorax
displacement
(mm)
Probe force
(N)
25.0
27.0
28.3
28.7
1526
1663
1625
1652
TABLE 25—HIGH-ENERGY THORAX WITHOUT ARM IMPACT TEST RESPONSES
Test No.
Energy
increase
(nominal)
(percent)
Impact speed
(m/s)
baseline ............................................................................................
1 .......................................................................................................
2 .......................................................................................................
3 .......................................................................................................
4 .......................................................................................................
5 .......................................................................................................
0
50
70
80
............................
............................
3.3
4.0
4.3
4.4
............................
............................
High-Energy Lumbar Pendulum Tests
We conducted high-energy frontal and
lateral lumbar pendulum tests according
to the qualification test set-up
procedures, except the impact speeds
were increased. For frontal pendulum
tests, the impact energy was increased
up to approximately 30 percent greater
than the qualification test, while lateral
tests were increased up to
approximately 40 percent greater than
the qualification test.
The frontal test results are
summarized in Table 26 and the lateral
results are summarized in Table 27. The
Thorax
displacement
(mm)
Probe force
(N)
26.0
32.8
36.2
37.9
37.3
37.1
732
784
772
799
814
815
lumbar moment and rotation responses
did not indicate any unusual issues
with the lumbar spine element or load
cell in either of the test conditions. No
damage or delamination was observed
in post-test inspections of the lumbar
components.
TABLE 26—HIGH-ENERGY FRONTAL LUMBAR PENDULUM TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
Baseline .............................................................................
1 .........................................................................................
2 .........................................................................................
Max angle
Impact
speed, m/s
0
20
30
4.4
4.8
5.0
Angle
deg
53.3
57.5
60.3
Peak Y-moment
Time
ms
Moment
N-m
56.6
56.8
57.5
85.7
88.6
95.6
Time
ms
53.9
51.9
53.5
Head rotation
decay time,
ms
54.2
55.0
55.0
TABLE 27—HIGH-ENERGY LATERAL LUMBAR PENDULUM TEST RESPONSES
Energy
increase
(nominal)
(percent)
Test No.
Baseline .............................................................................
1 .........................................................................................
2 .........................................................................................
3 .........................................................................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
High-Energy Pelvis Impact Tests
We conducted high-energy pelvis
impacts in accordance with the
qualification test set-up procedures,
except we increased impact speeds to
achieve increases in kinetic energy of
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Max angle
Impact
speed, m/s
0
20
30
40
4.4
4.8
5.0
5.2
Angle
deg
53.9
59.0
60.7
62.9
approximately 15 percent, 40 percent,
and 55 percent. The responses for the
high-energy pelvis impact tests are
summarized in Table 28. At the highest
energy level, the lateral pubic load was
1057 N (well beyond the 450 N
maximum observed in the Cozy Cline
PO 00000
Frm 00022
Fmt 4701
Sfmt 4702
Peak Y-moment
Time
ms
Moment
N-m
56.0
57.3
57.4
56.6
83.5
95.7
100.8
107.7
Time
ms
50.3
54.0
54.0
53.3
Head rotation
decay time,
ms
49.2
54.0
54.0
53.3
R&R series) and the probe force was
2357 N. Analysis of the lateral pubic
load response revealed a smooth curve,
indicating no unusual contact internal
to the dummy. No damage to the pelvis
region was observed during post-test
inspections.
E:\FR\FM\21NOP2.SGM
21NOP2
69965
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE 28—HIGH-ENERGY PELVIS IMPACT TEST RESPONSES
Energy
Increase
(nominal)
(percent)
Test No.
baseline ..................................................................................................................................................
1 .............................................................................................................................................................
2 .............................................................................................................................................................
3 .............................................................................................................................................................
b. Q3s Servicing and Maintenance
In our experience with other Part 572
ATDs, deformable parts typically have
the shortest service lives. The two most
often replaced parts are the ribcage and
the molded neck. For example, we have
found the typical service life for HIII–
10C rib sets and neck assemblies to be
about thirty sled tests. Vinyl flesh
materials—particularly the chest flesh—
are also replaced on a recurring basis as
they become aged, abraded, or torn.
NHTSA owns four Q3s units of the
final Build Level D version, which
include the updated parts to improve
the durability of the thorax, neck, and
pelvis. There have been no durability
problems with the ATDs since they have
been upgraded to the latest build level.
Given the record of low maintenance to
our own Q3s units, we consider the
dummy to be highly suitable for
proposed use in FMVSS No. 213 in
terms of its durability. Our records
indicate that we have had relatively few
instances of Q3s part replacements of
any sort.
VIII. Drawings and Patents
Throughout the notice and comment
period of this Part 572 rulemaking, the
Q3s dummy will be available from
Humanetics. The Q3s engineering
drawings used to fabricate the dummy
are available in the docket for public
review and comment. The Q3s
engineering drawings are a proprietary
product owned by Humanetics,29 with
the exceptions noted in this section.
Thus, during the comment period most
drawings will display the Humanetics
name in the title block and will have the
following restrictive note:
This drawing is the sole property of
Humanetics Innovative Solutions, Inc. and is
being provided to NHTSA and other related
organizations for evaluation and comment
related to NHTSA’s rulemaking process.
Except for commenting purposes pursuant to
this process, the drawing shall not be copied
or used for any other purpose without the
written consent of Humanetics Innovative
Solutions, Inc.
For the final rule, the note will be
removed and the dummy drawings and
designs will be free from any
restrictions. This includes their use in
fabrication and in building computer
simulation models of the dummy.
During this comment period, some
drawings will not have the Humanetics
name in the title block and will not have
the restrictive note on them. In these
cases, NHTSA contracted with
Humanetics to provide the part or
expressly contributed to the design of
the part. As described earlier in this
preamble, Humanetics fabricated the
Impact
speed
(m/s)
0.0
15
40
55
4.0
4.3
4.7
5.0
Pubic
force
(N)
796
843
1001
1057
Probe
force
(N)
1712
1896
2209
2357
Build Level D neck using detailed
specifications provided by NHTSA.
These specifications included detailed
engineering drawings and a prototype of
the neck itself. In addition, NHTSA also
contributed to the design of the femur,
hip, and several other minor parts of the
dummy.
The list of drawings related to those
agency’s efforts is shown in Table 29.
On these drawings, the NHTSA name
appears in the title block and the
restrictive note does not appear. These
drawings are available to the public for
use during this NPRM stage without
restriction.
NHTSA is aware that Humanetics has
filed a patent application with the
United States Patent and Trademark
Office covering certain parts of the Q3s
dummy. Prior to the publication of any
final rule, NHTSA plans to meet with
Humanetics and come to some
agreement that ensures the continued
availability of the Q3s dummy to the
general public at a reasonable price.
Notwithstanding the intellectual
property issues identified in this
section, NHTSA emphasizes that
readers should take this opportunity to
review the information provided in this
NPRM and provide responses on the
substantive aspects of the proposal.
TABLE 29—LIST OF Q3S DRAWINGS FOR WHICH NO RESTRICTIVE NOTE APPEARS
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Drawing No.
020–2400
020–2401
020–2402
020–2403
020–2404
020–2405
020–2406
020–2407
020–2408
020–2409
020–9611
020–9511
020–9607
Description
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
Neck assembly, Q3s ............................................................................................
Molded neck, Q3s ................................................................................................
Neck plate, top Q3s .............................................................................................
Neck plate, middle, Q3s .......................................................................................
Neck plate, bottom, Q3s ......................................................................................
Retaining ring, Q3s neck .....................................................................................
Square crimp, Q3s neck ......................................................................................
Bottom crimp, Q3s neck cable .............................................................................
Neck cable assembly, Q3s ..................................................................................
Retaining nut, Q3s neck ......................................................................................
Femur, Right ........................................................................................................
Femur, Left ...........................................................................................................
Femur reinforcement, Right .................................................................................
29 FTSS/Humanetics’ development of the Q3s
dummy was not performed directly under a
government research and development contract.
NHTSA procured its Q3s units under a standard
purchase order in which the FTSS/Humanetics
products were listed within a catalog with a price
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Used on
schedule. Using this same purchase mechanism,
our units were periodically sent back to FTSS/
Humanetics for warranty maintenance and
upgrades. As we performed subsequent tests on our
Q3s units, we routinely shared our results with
FTSS/Humanetics, and concurrently reported them
PO 00000
Frm 00023
Fmt 4701
Sfmt 4702
020–2400
020–2400
020–2400
020–2400
020–2400
020–2400
020–2400
020–2400
020–2400
020–2400
020–9616
020–9516
020–9616
in public and in SAE and ISO committee meetings,
providing test results, identifying problems, and
suggesting ways to correct problems. FTSS/
Humanetics produced parts based on this
information, and periodically provided new
components to NHTSA for evaluation.
E:\FR\FM\21NOP2.SGM
21NOP2
69966
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE 29—LIST OF Q3S DRAWINGS FOR WHICH NO RESTRICTIVE NOTE APPEARS—Continued
Drawing No.
020–9507
020–3537
020–9903
020–7116
020–7113
020–7115
020–7114
020–7117
020–7118
020–7103
020–7104
020–9000
020–9001
020–9002
020–9003
020–9004
020–9005
Description
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
..............................................
Femur reinforcement, Left ....................................................................................
Ball shoulder ........................................................................................................
End stop ...............................................................................................................
Hip joint assembly, Right .....................................................................................
Hip joint assembly, Left ........................................................................................
Hip cup assembly, Right ......................................................................................
Hip cup assembly, Left ........................................................................................
Hip cup, upper ......................................................................................................
Hip cup, lower ......................................................................................................
Detent peg ............................................................................................................
Spring retainer plate .............................................................................................
Q3s positioning tool .............................................................................................
Indicator arm ........................................................................................................
Extension bracket .................................................................................................
Cross beam ..........................................................................................................
Knee spacer .........................................................................................................
Pivot screw ...........................................................................................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
IX. Consideration of Alternatives
We considered the merits of
alternative test dummies for use in the
side impact test under consideration for
FMVSS No. 213. The closest viable
alternatives were the modified Hybrid
III 3-year-old child test dummy (HIII–
3C) and the Q3.
Consideration of the Modified HIII–3C
(‘‘3Cs’’)
The HIII–3C was originally developed
in 1992. It is used in FMVSS No. 208,
‘‘Occupant crash protection,’’ to
evaluate air bag aggressiveness or air bag
suppression when a child is close to a
deploying air bag, and in FMVSS No.
213’s frontal sled test for the evaluation
of child restraint performance. The HIII–
3C was not designed for lateral impacts.
Under lateral loading, the shoulder and
torso exhibit highly stiff behavior and
do not fully replicate a child’s
kinematics. NHTSA considered using
the HIII–3C in the 2002 FMVSS No. 213
ANPRM published in response to the
TREAD Act (see footnote 4, supra), but
concluded that the ATD was not
acceptable for use in side impact testing.
After the agency assessed the HIII–3C
in side impacts, NHTSA developed a
retrofit package for the dummy to install
a new head and neck with better lateral
biofidelity. The retrofitted dummy is
referred to as the ‘‘3Cs.’’
NHTSA evaluated the 3Cs and the
Q3s concurrently. Based on our
biofidelity evaluations, the 3Cs did not
achieve nearly as good a ranking as the
Q3s. The technical report, ‘‘Biofidelity
Assessment of the Q3s Three-Year-Old
Child Side Impact Dummy,’’ supra,
discusses the performance of the two
ATDs. The Q3s outperformed or is
equivalent to the 3Cs in every aspect of
biofidelity related to a dummy’s
response in a side impact. Given the
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
Used on
superior biofidelity of the Q3s, we
believe that it more accurately
represents the response expected of a
human child.
In addition, the Q3s has thorax
deflection instrumentation, which the
3Cs does not. We tentatively conclude
that the Q3s is a better dummy than the
3Cs to measure injury assessment values
in side impacts and is a preferable ATD
for use in the proposed side impact
upgrade to FMVSS No. 213.
Consideration of the Q3
As discussed in section II of this
preamble, the design of the Q3s was
derived from the original Q3 dummy
developed by the European community.
The Q3 is intended for use in frontal,
side, and rear impacts.
Around the same time Humanetics
was working to bring the Q3s up to
production level, the Q3 underwent a
significant design revision. Starting in
2003, a ‘‘new’’ Q3 took shape. Many of
the new design concepts included in the
Q3s were also built into the Q3 as
Humanetics worked concurrently on
both dummies (e.g., thorax string
potentiometers were replaced by IR–
TRACCs in both dummies). Still, as
reported by the European Enhanced
Vehicle-Safety Committee (Wismans, et
al., 2008), the new Q3 does not respond
well in lateral biofidelity tests.
Furthermore, the thorax of the new Q3
has become even less biofidelic than the
original. Therefore, NHTSA does not
consider the Q3 preferable to the Q3s.
Conclusion
The agency tentatively concludes that
the improved biofidelity and additional
injury assessment capability of the Q3s
compared to the other commercially
available child side impact test
dummies supports a decision to adopt
PO 00000
Frm 00024
Fmt 4701
Sfmt 4702
020–9516
020–9616,
020–9616,
020–7116
020–7113
020–7116,
020–7116,
020–7116,
020–7116,
020–7116,
020–7116,
020–9000
020–9000
020–9000
020–9000
020–9000
020–9000
020–9516
020–9516
020–7113
020–7113
020–7113
020–7113
020–7113
020–7113
the Q3s into 49 CFR Part 572. The Q3s
dummy is a state-of-the-art device that
would allow for a better assessment of
the risk of injury to child occupants
than the alternative test dummies. The
availability of Q3s’s injury measuring
capability also is important to the
design, development and evaluation of
the side impact protection of child
restraint systems. The Q3s test dummy
is available today, and has been
thoroughly evaluated for suitable
reproducibility and repeatability of
results.
X. Rulemaking Analyses and Notices
Executive Order (E.O.) 12866 and E.O.
13563, and DOT Regulatory Policies and
Procedures
NHTSA has considered the impacts of
this regulatory action under E.O. 12866
and E.O. 13563. This rulemaking action
was not reviewed by the Office of
Management and Budget under E.O.
12866. The rulemaking has also been
determined to be non-significant under
DOT’s regulatory policies and
procedures.
This document would amend 49 CFR
Part 572 by adding design and
performance specifications for a test
dummy representative of a 3-year-old
child that the agency would possibly
use in FMVSS No. 213 side impact
compliance tests and possibly for
research purposes. This Part 572
proposed rule would not impose any
requirements on anyone. Businesses are
affected only if they choose to
manufacture or test with the dummy.
Because the economic impacts of this
proposed rule are minimal, no further
regulatory evaluation is necessary.
There are benefits associated with this
rulemaking but they cannot be
quantified. The incorporation of the test
dummy into 49 CFR Part 572 would
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
tkelley on DSK3SPTVN1PROD with PROPOSALS2
enable NHTSA to use the ATD in a new
dynamic side impact test that we are
considering adopting into FMVSS No.
213. Adoption of side impact protection
requirements in FMVSS No. 213
enhances child passenger safety and
accords with MAP–21. In addition, the
availability of this dummy in a
regulated format would be beneficial by
providing a suitable, stabilized, and
objective test tool to the safety
community for use in better protecting
children in side impacts.
The cost of an uninstrumented Q3s
dummy is approximately $48,750. The
minimum set of instrumentation needed
for qualification and compliance type
testing includes three uni-axial
accelerometers (part no. SA572–S4), one
neck/spine load cell (SA572–S8), one
shoulder potentiometer set (SA572–S38
and S39), one single axis IR–TRACC
(SA572–S37), and one pubic load cell
(SA572–S7). The cost of this
instrumentation adds approximately
$18,200 for a total cost of about $66,950.
We have not estimated the costs of the
equipment needed to perform the
qualification tests other than the
instrumentation needed (two angular
rate sensors, $1,230 apiece; one test
probe accelerometer, $500; one rotary
potentiometer, $500.) With the
exception of the neck torsion fixture, the
angular rate sensors, and the 3.8 kg test
probe, all fixtures and instruments are
common with those used to qualify
other Part 572 dummies.
We recognize that dummy
refurbishments and part replacements
are an inherent part of ATD testing.
Various parts will likely have to be
refurbished or replaced, but we do not
know which parts are likely to be
worked on the most. However, since the
dummies are designed to be reusable,
costs of the dummies and of parts can
be amortized over a number of tests.
Regulatory Flexibility Act
Pursuant to the Regulatory Flexibility
Act (5 U.S.C. 601 et seq., as amended by
the Small Business Regulatory
Enforcement Fairness Act (SBREFA) of
1996), whenever an agency is required
to publish a proposed or final rule, it
must prepare and make available for
public comment a regulatory flexibility
analysis that describes the effect of the
rule on small entities (i.e., small
businesses, small organizations, and
small governmental jurisdictions),
unless the head of the agency certifies
the rule will not have a significant
economic impact on a substantial
number of small entities. The Small
Business Administration’s regulations at
13 CFR Part 121 define a small business,
in part, as a business entity ‘‘which
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
operates primarily within the United
States.’’ (13 CFR 121.105(a)).
We have considered the effects of this
rulemaking under the Regulatory
Flexibility Act. I hereby certify that this
rulemaking action would not have a
significant economic impact on a
substantial number of small entities.
This action would not have a significant
economic impact on a substantial
number of small entities because the
addition of the test dummy to Part 572
would not impose any requirements on
anyone. NHTSA would use the ATD in
agency testing but would not require
anyone to manufacture the dummy or to
test motor vehicles or motor vehicle
equipment with it.
National Environmental Policy Act
NHTSA has analyzed this proposed
rule for the purposes of the National
Environmental Policy Act and
determined that it would not have any
significant impact on the quality of the
human environment.
Executive Order 13045 and 13132
(Federalism)
Executive Order 13045 (62 FR 19885,
April 23, 1997) applies to any rule that:
(1) Is determined to be ‘‘economically
significant’’ as defined under E.O.
12866, and (2) concerns an
environmental, health, or safety risk that
NHTSA has reason to believe may have
a disproportionate effect on children. If
the regulatory action meets both criteria,
we must evaluate the environmental
health or safety effects of the planned
rule on children, and explain why the
planned regulation is preferable to other
potentially effective and reasonably
feasible alternatives considered by us.
This proposed rule is not subject to
the Executive Order because it is not
economically significant as defined in
E.O. 12866.
NHTSA has examined today’s
proposed rule pursuant to Executive
Order 13132 (64 FR 43255, August 10,
1999) and concluded that no additional
consultation with States, local
governments or their representatives is
mandated beyond the rulemaking
process. The agency has concluded that
the proposed rule would not have
federalism implications because the
proposed rule would not have
‘‘substantial direct effects on the States,
on the relationship between the national
government and the States, or on the
distribution of power and
responsibilities among the various
levels of government.’’ This proposed
rule would not impose any
requirements on anyone. Businesses
will be affected only if they choose to
manufacture or test with the dummy.
PO 00000
Frm 00025
Fmt 4701
Sfmt 4702
69967
Further, no consultation is needed to
discuss the preemptive effect of today’s
proposed rule. NHTSA’s safety
standards can have preemptive effect in
two ways. This proposed rule would
amend 49 CFR Part 572 and is not a
safety standard.30 This Part 572
proposed rule would not impose any
requirements on anyone.
Civil Justice Reform
With respect to the review of the
promulgation of a new regulation,
section 3(b) of Executive Order 12988,
‘‘Civil Justice Reform’’ (61 FR 4729,
February 7, 1996) requires that
Executive agencies make every
reasonable effort to ensure that the
regulation: (1) Clearly specifies the
preemptive effect; (2) clearly specifies
the effect on existing Federal law or
regulation; (3) provides a clear legal
standard for affected conduct, while
promoting simplification and burden
reduction; (4) clearly specifies the
retroactive effect, if any; (5) adequately
defines key terms; and (6) addresses
other important issues affecting clarity
and general draftsmanship under any
guidelines issued by the Attorney
General. This document is consistent
with that requirement.
Pursuant to this Order, NHTSA notes
as follows.
The issue of preemption is discussed
above in connection with E.O. 13132.
NHTSA notes further that there is no
requirement that individuals submit a
petition for reconsideration or pursue
other administrative proceeding before
they may file suit in court.
Paperwork Reduction Act
Under the Paperwork Reduction Act
of 1995, a person is not required to
respond to a collection of information
by a Federal agency unless the
collection displays a valid control
number from the Office of Management
and Budget (OMB). This proposed rule
would not have any requirements that
are considered to be information
30 With respect to the safety standards, the
National Traffic and Motor Vehicle Safety Act
contains an express preemptive provision: ‘‘When
a motor vehicle safety standard is in effect under
this chapter, a State or a political subdivision of a
State may prescribe or continue in effect a standard
applicable to the same aspect of performance of a
motor vehicle or motor vehicle equipment only if
the standard is identical to the standard prescribed
under this chapter.’’ 49 U.S.C. 30103(b)(1). Second,
the Supreme Court has recognized the possibility of
implied preemption: State requirements imposed
on motor vehicle manufacturers, including
sanctions imposed by State tort law, can stand as
an obstacle to the accomplishment and execution of
a NHTSA safety standard. When such a conflict
exists, the Supremacy Clause of the Constitution
makes the State requirements unenforceable. See
Geier v. American Honda Motor Co., 529 U.S. 861
(2000).
E:\FR\FM\21NOP2.SGM
21NOP2
69968
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
collection requirements as defined by
the OMB in 5 CFR Part 1320.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
National Technology Transfer and
Advancement Act
Section 12(d) of the National
Technology Transfer and Advancement
Act of 1995 (NTTAA), Public Law 104–
113, section 12(d) (15 U.S.C. 272)
directs NHTSA to use voluntary
consensus standards in its regulatory
activities unless doing so would be
inconsistent with applicable law or
otherwise impractical. Voluntary
consensus standards are technical
standards (e.g., materials specifications,
test methods, sampling procedures, and
business practices) that are developed or
adopted by voluntary consensus
standards bodies. The NTTAA directs
NHTSA to provide Congress, through
OMB, explanations when the agency
decides not to use available and
applicable voluntary consensus
standards.
The following voluntary consensus
standards have been used in developing
the Q3s:
• SAE Recommended Practice J211,
Rev. Mar 95, ‘‘Instrumentation for
Impact Tests—Part 1—Electronic
Instrumentation’’; and,
• SAE J1733 of 1994–12 ‘‘Sign
Convention for Vehicle Crash Testing.’’
Unfunded Mandates Reform Act
Section 202 of the Unfunded
Mandates Reform Act of 1995 (UMRA),
Public Law 104–4, requires Federal
agencies to prepare a written assessment
of the costs, benefits, and other effects
of proposed or final rules that include
a Federal mandate likely to result in the
expenditure by State, local, or tribal
governments, in the aggregate, or by the
private sector, of more than $100
million annually (adjusted for inflation
with base year of 1995). Before
promulgating a NHTSA rule for which
a written statement is needed, section
205 of the UMRA generally requires the
agency to identify and consider a
reasonable number of regulatory
alternatives and adopt the least costly,
most cost-effective, or least burdensome
alternative that achieves the objectives
of the rule.
This proposed rule would not impose
any unfunded mandates under the
UMRA. This proposed rule does not
meet the definition of a Federal mandate
because it does not impose requirements
on anyone. It amends 49 CFR Part 572
by adding design and performance
specifications for a 3-year-old child side
impact test dummy that the agency
could use in FMVSS No. 213 and for
research purposes. This proposed rule
would affect only those businesses that
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
choose to manufacture or test with the
dummy. It would not result in costs of
$100 million or more to either State,
local, or tribal governments, in the
aggregate, or to the private sector.
Plain Language
Executive Order 12866 requires each
agency to write all rules in plain
language. Application of the principles
of plain language includes consideration
of the following questions:
Has the agency organized the material
to suit the public’s needs?
Are the requirements in the rule
clearly stated?
Does the rule contain technical
language or jargon that is not clear?
Would a different format (grouping
and order of sections, use of headings,
paragraphing) make the rule easier to
understand?
Would more (but shorter) sections be
better?
Could the agency improve clarity by
adding tables, lists, or diagrams?
What else could the agency do to
make this rulemaking easier to
understand?
If you have any responses to these
questions, please send them to NHTSA.
Regulation Identifier Number
The Department of Transportation
assigns a regulation identifier number
(RIN) to each regulatory action listed in
the Unified Agenda of Federal
Regulations. The Regulatory Information
Service Center publishes the Unified
Agenda in April and October of each
year. You may use the RIN contained in
the heading at the beginning of this
document to find this action in the
Unified Agenda.
XI. Public Participation
How do I prepare and submit
comments?
Your comments must be written and
in English. To ensure better that your
comments are correctly filed in the
Docket, please include the docket
number of this document in your
comments.
Your comments must not be more
than 15 pages long. (49 CFR 553.21). We
established this limit to encourage you
to write your primary comments in a
concise fashion. However, you may
attach necessary additional documents
to your comments. There is no limit on
the length of the attachments.
Comments may also be submitted to
the docket electronically by logging into
https://www.regulations.gov. Follow the
online instructions for submitting
comments.
Please note that pursuant to the Data
Quality Act, in order for substantive
PO 00000
Frm 00026
Fmt 4701
Sfmt 4702
data to be relied upon and used by the
agency, it must meet the information
quality standards set forth in the OMB
and DOT Data Quality Act guidelines.
Accordingly, we encourage you to
consult the guidelines in preparing your
comments. OMB’s guidelines may be
accessed at https://www.whitehouse.gov/
omb/fedreg/reproducible.html.
How can I be sure that my comments
were received?
If you wish the Docket Management
Facility to notify you upon its receipt of
your comments, enclose a selfaddressed, stamped postcard in the
envelope containing your comments.
Upon receiving your comments, the
Docket Management Facility will return
the postcard by mail.
How do I submit confidential business
information?
If you wish to submit any information
under a claim of confidentiality, you
should submit three copies of your
complete submission, including the
information you claim to be confidential
business information, to the Chief
Counsel’s office, NHTSA, at the address
given above under FOR FURTHER
INFORMATION CONTACT. In addition, you
should submit two copies, from which
you have deleted the claimed
confidential business information, to the
Docket Management Facility at the
address given above under ADDRESSES.
When you send a comment containing
information claimed to be confidential
business information, you should
include a cover letter setting forth the
information specified in our
confidential business information
regulation. (49 CFR Part 512.)
Will the agency consider late
comments?
We will consider all comments that
the docket receives before the close of
business on the comment closing date
indicated above under DATES. To the
extent possible, we will also consider
comments received after that date. If the
docket receives a comment too late for
us to consider in developing a final rule
(assuming that one is issued), we will
consider that comment as an informal
suggestion for a future rulemaking
action.
How can I read the comments submitted
by other people?
You may read the comments received
by the Docket Management Facility at
the address given above under
ADDRESSES. The hours of the Docket are
indicated above in the same location.
You may also see the comments on the
Internet. To read the comments on the
E:\FR\FM\21NOP2.SGM
21NOP2
69969
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
Internet, go to https://
www.regulations.gov. Follow the online
instructions for accessing the dockets.
Please note that even after the
comment closing date, we will continue
to file relevant information in the docket
as it becomes available. Further, some
people may submit late comments.
Accordingly, we recommend that you
periodically check the docket for new
material.
Anyone is able to search the
electronic form of all comments
received into any of our dockets by the
name of the individual submitting the
comment (or signing the comment, if
submitted on behalf of an association,
business, labor union, etc.). You may
review DOT’s complete Privacy Act
Statement in the Federal Register
published on April 11, 2000 (Volume
65, Number 70; Pages 19477–78).
List of Subjects in 49 CFR Part 572
Motor vehicle safety, Incorporation by
reference.
In consideration of the foregoing,
NHTSA proposes to amend 49 CFR Part
572 as follows:
PART 572—ANTHROPOMORPHIC
TEST DEVICES
1. The authority citation for Part 572
would be amended to read as follows:
■
Authority: 49 U.S.C. 322, 30111, 30115,
30117 and 30166; delegation of authority at
49 CFR 1.95.
2. 49 CFR Part 572 would be amended
by adding a new Subpart W consisting
of 572.210–572.219 to read as follows:
■
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Subpart W—Q3s Three-Year-Old Child Test
Dummy
Secs.
572.210 Incorporation by reference.
572.211 General description.
572.212 Head assembly and test procedure.
572.213 Neck assembly and test procedure.
572.214 Shoulder assembly and test
procedure.
572.215 Thorax with arm assembly and test
procedure.
572.216 Thorax without arm assembly and
test procedure.
572.217 Lumbar spine assembly and test
procedure.
572.218 Pelvis assembly and test procedure.
572.219 Test conditions and
instrumentation.
Appendix—Figures to Subpart W of Part 572
§ 572.210
Incorporation by reference.
(a) Certain material is incorporated by
reference (IBR) into this part with the
approval of the Director of the Federal
Register under 5 U.S.C. 552(a) and 1
CFR part 51. To enforce any edition
other than that specified in this section,
NHTSA must publish notice of change
in the Federal Register and the material
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
must be available to the public. All
approved material is available for
inspection at the Department of
Transportation, Docket Operations,
Room W12–140, telephone 202–366–
9826, and is available from the sources
listed below. The material is available in
electronic format through
Regulations.gov, call 1–877–378–5457
or go to www.regulations.gov. It is also
available for inspection at the National
Archives and Records Administration
(NARA). For information on the
availability of this material at NARA,
call 202–741–6030 or go to https://
www.archives.gov/federal-register/cfr/
ibr-locations.html.
(b) NHTSA Technical Information
Services, 1200 New Jersey Ave. SE.,
Washington, DC 20590, telephone 202–
366–5965.
(1) A parts/drawing list entitled,
‘‘Parts/Drawings List, Part 572 Subpart
W, Q3s Three-Year-Old Child Test
Dummy, May 2012,’’ IBR approved for
§ 572.211.
(2) A drawings and inspection
package entitled, ‘‘Parts List and
Drawings, Part 572 Subpart W, Q3s
Three-Year-Old Child Test Dummy,
May 2012,’’ IBR approved for § 572.211,
including:
(i) Drawing No. 020–0100, Complete
Assembly Q3s, IBR approved for
§§ 572.211, 572.212, 572.213, 572.214,
572.215, 572.216, 572.217, 572.218, and
572.219.
(ii) Drawing No. 020–1200, Head
Assembly, IBR approved for §§ 572.211,
572.212, 572.214, 572.215, 572.216,
572.218, and 572.219.
(iii) Drawing No. 020–2400, Neck
Assembly, IBR approved for §§ 572.211,
572.213, 572.214, 572.215, 572.216,
572.218, and 572.219.
(iv) Drawing No. 020–9050,
Headform, IBR approved for §§ 572.211,
572.213, 572.217 and 572.219.
(v) Drawing No. DL210–200, Neck
Twist Fixture, IBR approved for
§§ 572.211, 572.213, and 572.219.
(vi) Drawing No. 020–4500, Torso
Assembly, IBR approved for §§ 572.211,
572.214, 572.215, 572.216, 572.218 and
572.219.
(vii) Drawing No. 020–6000, Lumbar
Spine Assembly, IBR approved for
§§ 572.211, 572.217 and 572.219.
(viii) Drawing No. 020–7500, Pelvis
Assembly, IBR approved for §§ 572.211,
572.214, 572.215, 572.216, 572.218, and
572.219.
(ix) Drawing No. 020–8001, Q3s Suit,
IBR approved for §§ 572.211, 572.214,
572.215, 572.216, 572.218, and 572.219.
(x) Drawing No. 020–9500, Complete
Leg Assembly—left, IBR approved for
§§ 572.211, 572.214, 572.215, 572.216,
PO 00000
Frm 00027
Fmt 4701
Sfmt 4702
572.218, and 572.219 as part of a
complete dummy assembly.
(xi) Drawing No. 020–9600, Complete
Leg Assembly—right, IBR approved for
§§ 572.211, 572.214, 572.215, 572.216,
572.218, and 572.219 as part of a
complete dummy assembly.
(xii) Drawing No. 020–9700, Complete
Arm Assembly—left, IBR approved for
§§ 572.211, 572.214, 572.215, 572.216,
572.218, and 572.219 as part of a
complete dummy assembly.
(xiii) Drawing No. 020–9800,
Complete Arm Assembly—right, IBR
approved for §§ 572.211, 572.214,
572.215, 572.216, 572.218, and 572.219
as part of a complete dummy assembly.
(3) A procedures manual entitled
‘‘Procedures for Assembly, Disassembly
and Inspection (PADI) of the Q3s Child
Side Impact Crash Test Dummy,
September 2013,’’ IBR approved for
§§ 572.211 and 572.219.
(c) SAE International, 400
Commonwealth Drive, Warrendale, PA
15096, call 1–877–606–7323.
(1) SAE Recommended Practice J211,
Rev. Mar 95, ‘‘Instrumentation for
Impact Tests—Part 1—Electronic
Instrumentation,’’ IBR approved for
§ 572.219;
(2) SAE Information Report J1733 of
1994–12, ‘‘Sign Convention for Vehicle
Crash Testing,’’ IBR approved for
§ 572.219.
§ 572.211
General description.
(a) The Q3s Three-Year-Old Child
Test Dummy is defined by drawings and
specifications containing the following
materials:
(1) The parts enlisted in ‘‘Parts List
and Drawings, Part 572 Subpart W, Q3s
Three-Year-Old Child Test Dummy,
September 2013’’ (incorporated by
reference, see § 572.210).
(2) The engineering drawings and
specifications contained in ‘‘Parts List
and Drawings, Part 572 Subpart W, Q3s
Three-Year-Old Child Test Dummy,
September 2013,’’ which includes the
engineering drawings and specifications
described in Drawing 020–0000, the
titles of which are listed in Table A,
and,
(3) A manual entitled ‘‘Procedures for
Assembly, Disassembly and Inspection
(PADI) of the Q3s Child Side Impact
Crash Test Dummy, September 2013.’’
TABLE A TO § 572.211
Component assembly
(i) Head Assembly .............
(ii) Neck Assembly .............
(iii) Torso Assembly ...........
(iv) Lumbar Spine Assembly.
(v) Pelvis Assembly ...........
E:\FR\FM\21NOP2.SGM
21NOP2
Drawing number
020–1200
020–2400
020–4500
020–6000
020–7500
69970
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
TABLE A TO § 572.211—Continued
Component assembly
(vi) Complete Leg Assembly—left.
(vii) Complete Leg Assembly—right.
(viii) Complete Arm Assembly—left.
(ix) Complete Arm Assembly—right.
Drawing number
020–9500
020–9600
020–9700
020–9800
(b) The structural properties of the
dummy are such that the dummy
conforms to this Subpart in every
respect before use in any test.
tkelley on DSK3SPTVN1PROD with PROPOSALS2
§ 572.212 Head assembly and test
procedure.
(a) The head assembly for this test
consists of the complete head (drawing
020–1200) with head accelerometer
assembly (drawing 020–1013A), and a
half mass simulated upper neck load
cell (drawing 020–1050) (all
incorporated by reference, see
§ 572.210).
(b) When the head assembly is tested
according to the test procedure in
paragraph (c) of this section, it shall
have the following characteristics:
(1) Frontal head qualification test.
When the head assembly is dropped
from a height of 376.0 ± 1.0 mm (14.8
± 0.04 in) in accordance with subsection
(c) of this section, the peak resultant
acceleration at the location of the
accelerometers at the head CG shall
have a value between 250 G and 297 G.
The resultant acceleration vs. time
history curve shall be unimodal;
oscillations occurring after the main
pulse must be less than 10 percent of
the peak resultant acceleration. The
lateral acceleration shall not exceed 15
G (zero to peak).
(2) Lateral head qualification test.
When the head assembly is dropped
from a height of 200.0 ± 1.0 mm (7.87
± 0.04 in) in accordance with subsection
(c) of this section, the peak resultant
acceleration at the location of the
accelerometers at the head CG shall
have a value between 113 G and 140 G.
The resultant acceleration vs. time
history curve shall be unimodal;
oscillations occurring after the main
pulse must be less than 10 percent of
the peak resultant acceleration. The Xcomponent acceleration shall not
exceed 20 G (zero to peak).
(c) Test procedure: The test procedure
for the head assembly is as follows:
(1) Soak the head assembly in a
controlled environment at any
temperature between 18.9 and 25.6 °C
(66 and 78 °F) and a relative humidity
from 10 to 70 percent for at least four
hours prior to a test.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
(2) Prior to the test, clean the impact
surface of the skin and the impact plate
surface with isopropyl alcohol,
trichloroethane, or an equivalent. The
skin of the head and the impact plate
surface must be clean and dry for
testing.
(3)(i) For the frontal head test,
suspend and orient the head assembly
with the forehead facing the impact
surface as shown in Figure W1. The
lowest point on the forehead must be
376.0 ± 1.0 mm (14.8 ± 0.04 in) from the
impact surface. Assure that the head is
horizontal laterally. Adjust the head
angle so that the upper neck load cell
simulator is 28 ± 2 degrees forward from
the vertical while assuring that the head
remains horizontal laterally.
(ii) For the lateral head test, the head
is dropped on the aspect that opposes
the primary load vector of the ensuing
full scale test for which the dummy is
being qualified. A left drop set up that
is used to qualify the dummy for an
ensuing full scale left side impact is
depicted in Figure W2. A right drop setup would be the mirror image of that
shown in Figure W2. Suspend and
orient the head assembly as shown in
Figure W2. The lowest point on the
impact side of the head must be 200.0
± 1.0 mm (7.87 ± 0.04 in) from the
impact surface. Assure that the head is
horizontal in the fore-aft direction.
Adjust the head angle so that the head
base plane measured from the base
surface of the upper neck load cell
simulator is 35 ± 2 degrees forward from
the vertical while assuring that the head
remains horizontal in the fore-aft
direction.
(4) Drop the head assembly from the
specified height by means that ensure a
smooth, instant release onto a rigidly
supported flat horizontal steel plate
which is 50.8 mm (2 in) thick and 610
mm (24 in) square. The impact surface
shall be clean, dry and have a micro
finish of not less than 203.2 × 10¥6 mm
(8 micro inches) (RMS) and not more
than 2,032.0 × 10¥6 mm (80 micro
inches) (RMS).
(5) Allow at least 2 hours between
successive tests on the same head.
§ 572.213 Neck assembly and test
procedure.
(a)(1) The neck and headform
assembly (refer to § 572.210(b)(2)(iii)
and § 572.210(b)(2)(iv)) for the purposes
of the fore-aft neck flexion and lateral
neck flexion qualification tests, as
shown in Figures W3 and W4, consists
of the headform (drawing 020–9050,
sheet 1) with angular rate sensor
installed (drawing SA572–S58), sixchannel neck/lumbar load cell (drawing
SA572–S8), neck assembly (drawing
PO 00000
Frm 00028
Fmt 4701
Sfmt 4702
020–2400), neck/torso interface plate
(drawing 020–9056) and pendulum
interface plate (drawing 020–9051) with
angular rate sensor installed (drawing
SA572–S58) (all incorporated by
reference, see § 572.210).
(2) The neck assembly (refer to
§ 572.210(b)(2)(iii) and
§ 572.210(b)(2)(v)) for the purposes of
the neck torsion qualification test, as
shown in Figure W5, consists of the
neck twist fixture (drawing DL210–200)
with rotary potentiometer installed
(drawing SA572–S51), neck adaptor
plate assembly (drawing DL210–220),
neck assembly (drawing 020–2400), sixchannel neck/lumbar load cell (drawing
SA572–S8), and twist fixture end plate
(drawing DL210–210) (all incorporated
by reference, see § 572.210).
(b) When the neck and headform
assembly as defined in § 572.213(a)(1),
or the neck assembly as defined in
§ 572.213(a)(2), is tested according to
the test procedure in paragraph (c) of
this section, it shall have the following
characteristics:
(1) Fore-aft neck flexion qualification
test.
(i) Plane D, referenced in Figure W3,
shall rotate in the direction of preimpact flight with respect to the
pendulum’s longitudinal centerline
between 70 degrees and 82 degrees,
which shall occur between 55 and 63
ms from time zero. The peak moment,
measured by the neck transducer
(drawing SA572–S8) (incorporated by
reference, see § 572.210) shall have a
value between 41 N-m (30.2 ft-lbf) and
51 N-m (37.6 ft-lbf) occurring between
49 and 62 ms from time zero.
(ii) The decaying headform rotation
vs. time curve shall cross the zero angle
with respect to its initial position at
time of impact relative to the pendulum
centerline between 50 to 54 ms after the
time the peak rotation value is reached.
(iii) All instrumentation data channels
are defined to be zero when the
longitudinal centerline of the neck and
pendulum are parallel.
(iv) The headform rotation shall be
calculated by the following formula
with the integration beginning at time
zero:
Headform rotation (deg) = ∫ [(Headform
Angular Rate)y¥(Pendulum
Angular Rate)y] dt
(v) (Headform Angular Rate)y is the
angular rate about the y-axis in deg/sec
measured on the headform (drawing
020–9050, sheet 1), and (Pendulum
Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the
pendulum interface plate (drawing 020–
9051) (incorporated by reference, see
§ 572.210).
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
(2) Lateral neck flexion qualification
test.
(i) Plane D, referenced in Figure W4,
shall rotate in the direction of preimpact flight with respect to the
pendulum’s longitudinal centerline
between 77 degrees and 88 degrees,
which shall occur between 65 and 72
ms from time zero. The peak moment,
measured by the neck transducer
(drawing SA572–S8) (incorporated by
reference, see § 572.210) shall have a
value between 25 N-m (18.4 ft-lbf) and
32 N-m (23.6 ft-lbf) occurring between
66 and 73 ms from time zero.
(ii) The decaying headform rotation
vs. time curve shall cross the zero angle
with respect to its initial position at
time of impact relative to the pendulum
centerline between 63 to 69 ms after the
time the peak rotation value is reached.
(iii) All instrumentation data channels
are defined to be zero when the
longitudinal centerline of the neck and
pendulum are parallel.
(iv) The headform rotation shall be
calculated by the following formula
with the integration beginning at time
zero:
Headform rotation (deg) = ∫ [(Headform
Angular Rate)y¥(Pendulum
Angular Rate)y] dt
(v) (Headform Angular Rate)y is the
angular rate about the y-axis in deg/sec
measured on the headform (drawing
020–9050, sheet 1), and (Pendulum
Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the
pendulum interface plate (drawing 020–
9051) (incorporated by reference, see
§ 572.210).
(3) Neck torsion qualification test.
(i) The neck twist fixture (drawing
DL210–200), referenced in Figure W5,
shall rotate in the direction of preimpact flight with respect to the
pendulum’s longitudinal centerline
between 75 degrees and 93 degrees, as
measured by the rotary potentiometer
(drawing SA572–S51), and shall occur
between 91 and 113 ms from time zero.
The peak moment, measured by the
neck transducer (drawing SA572–S8)
shall have a value between 8 N-m (5.9
ft-lbf) and 10 N-m (7.4 ft-lbf) occurring
between 85 and 105 ms from time zero)
(all incorporated by reference, see
§ 572.210).
(ii) The decaying neck twist fixture
rotation vs. time curve shall cross the
zero angle with respect to its initial
position at time of impact relative to the
pendulum centerline between 84 to 103
ms after the time the peak rotation value
is reached.
(iii) All instrumentation data channels
are defined to be zero when the zero
pins are installed such that the neck is
not in torsion.
(iv) Time zero is defined as the time
of initial contact between the pendulum
striker plate and the honeycomb
material. All data channels shall be at
the zero level at this time.
(c) Test procedure: The test procedure
for the neck assembly is as follows:
(1) Soak the neck assembly in a
controlled environment at any
temperature between 20.6 and 22.2 °C
(69 and 72 °F) and a relative humidity
between 10 and 70 percent for at least
four hours prior to a test.
(2)(i) For the fore-aft neck flexion test,
mount the neck and headform assembly,
defined in subsection (a)(1) of this
section, on the pendulum described in
Figure 22 of 49 CFR 572 so that the
midsagittal plane of the headform is
vertical and coincides with the plane of
motion of the pendulum, and with the
neck placement such that the front side
of the neck is closest to the honeycomb
material.
(ii) For the lateral neck flexion test,
the test is carried out in the direction
opposing the primary load vector of the
ensuing full scale test for which the
69971
dummy is being qualified. A right
flexion test set-up that is used to qualify
the dummy for an ensuing full scale
right side impact is depicted in Figure
W4. A left flexion test set-up would be
a mirror image of that shown in Figure
W4. Mount the neck and headform
assembly, defined in subsection (a)(1) of
this section, on the pendulum described
in Figure 22 of 49 CFR 572 so that the
midsagittal plane of the headform is
vertical and coincides with the plane of
motion of the pendulum, and with the
neck placement such that the right (or
left) side of the neck is closest to the
honeycomb material.
(iii) For the neck torsion test, the test
is carried out in the direction opposing
the primary load vector of the ensuing
full scale test for which the dummy is
being qualified. A right torsion test setup that is used to qualify the dummy for
an ensuing full scale right side impact
is depicted in Figure W5. A left flexion
test set-up would be a mirror image of
that shown in Figure W5. Mount the
neck assembly, defined in subsection
(a)(2) of this section, on the pendulum
described in Figure 22 of 49 CFR 572,
as shown in Figure W5 of this subpart.
(3)(i) Release the pendulum and allow
it to fall freely from a height to achieve
an impact velocity of 4.7 ± 0.1 m/s (15.6
± 0.3 ft/s) for fore-aft flexion, 3.8 ± 0.05
m/s (12.5 ± 0.2 ft/s) for lateral flexion,
and 3.6 ± 0.1 m/s (11.8 ± 0.3 ft/s) for
torsion, measured by an accelerometer
mounted on the pendulum as shown in
Figure 22 of this Part 572 at time zero.
(ii) Stop the pendulum from the
initial velocity with an acceleration vs.
time pulse that meets the velocity
change as specified in Table B of this
section. Integrate the pendulum
accelerometer data channel to obtain the
velocity vs. time curve beginning at time
zero.
TABLE B TO § 572.213
Fore-aft flexion
Time
(ms)
m/s
tkelley on DSK3SPTVN1PROD with PROPOSALS2
10
20
30
1.1–2.1
2.8–3.8
4.1–5.1
Time
(ms)
ft/s
3.6–6.9
9.2–12.5
13.5–16.7
§ 572.214 Shoulder assembly and test
procedure.
(a) The shoulder assembly for this test
consists of the torso assembly (drawing
020–4500) with string pot assembly
(drawing SA572–S38 or SA572–S39)
installed (incorporated by reference, see
§ 572.210).
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
10
15
20
Lateral flexion
m/s
ft/s
1.7–2.2
2.5–3.0
3.4–3.9
5.6–7.2
8.2–9.8
11.2–12.8
(b) When the center of the shoulder of
a completely assembled dummy
(drawing 020–0100) (incorporated by
reference, see § 572.210) is impacted
laterally by a test probe conforming to
§ 572.219, at 3.6 ± 0.1 m/s (11.8 ± 0.3 ft/
s) according to the test procedure in
paragraph (c) of this section:
PO 00000
Frm 00029
Fmt 4701
Sfmt 4702
Torsion
Time
(ms)
m/s
10
15
20
0.9–1.3
1.4–2.0
2.0–2.6
ft/s
3.0–4.3
4.6–6.6
6.6–8.5
(1) Maximum lateral shoulder
displacement (compression) relative to
the spine, measured with the string pot
assembly (drawing SA572–S38 or
SA572–S39) (incorporated by reference,
see § 572.210), must not be less than 16
mm (0.63 in) and not more than 21 mm
(0.83 in). The peak force, measured by
the impact probe as defined in § 572.219
E:\FR\FM\21NOP2.SGM
21NOP2
tkelley on DSK3SPTVN1PROD with PROPOSALS2
69972
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
and calculated in accordance with
paragraph (b)(2) of this section, shall
have a value between 1.24 kN (279 lbf)
and 1.35 kN (303 lbf).
(2) The force shall be calculated by
the product of the impactor mass and its
measured deceleration.
(c) Test procedure: The test procedure
for the shoulder assembly is as follows:
(1) The dummy is clothed in the Q3s
suit (drawing 020–8001) (incorporated
by reference, see § 572.210). No
additional clothing or shoes are placed
on the dummy.
(2) Soak the dummy in a controlled
environment at any temperature
between 20.6 and 22.2 ßC (69 and 72 ßF)
and a relative humidity from 10 to 70
percent for at least four hours prior to
a test.
(3) The shoulder test is carried out in
the direction opposing the primary load
vector of the ensuing full scale test for
which the dummy is being qualified. A
left shoulder test set-up that is used to
qualify the dummy for an ensuing full
scale left side impact is depicted in
Figure W6. A right shoulder set-up
would be a mirror image of that shown
in Figure W6. Seat the dummy on the
qualification bench described in Figure
V3 of 49 CFR 572.194, the seat pan and
seat back surfaces of which are covered
with thin sheets of PTFE (Teflon)
(nominal stock thickness: 2 to 3 mm) (3/
32- to 1/8-inch) along the impact side of
the bench.
(4) Position the dummy on the bench
as shown in Figure W6, with the ribs
making contact with the seat back
oriented 24.6 degrees relative to vertical,
the legs extended forward along the seat
pan oriented 21.6 degrees relative to
horizontal with the knees spaced 40 mm
(1.57 in) apart, and the arms positioned
so that the upper arms are parallel to the
seat back (± 2 degrees) and the lower
arms are perpendicular to the upper
arms.
(5) The target point of the impact is
a point on the shoulder that is 15 mm
above and perpendicular to the
midpoint of a line connecting the
centers of the bolt heads of the two
lower bolts (part #5000010) that connect
the upper arm assembly (020–9750) to
the shoulder ball retaining ring (020–
3533).
(6) Impact the shoulder with the test
probe so that at the moment of contact
the probe’s longitudinal centerline
should be horizontal (± 1 degrees), and
the centerline of the probe should be
within 2 mm (0.08 in) of the target
point.
(7) Guide the test probe during impact
so that there is no significant lateral,
vertical, or rotational movement.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
(8) No suspension hardware,
suspension cables, or any other
attachments to the probe, including the
velocity vane, shall make contact with
the dummy during the test.
§ 572.215 Thorax with arm assembly and
test procedure.
(a) The thorax assembly for this test
consists of the torso assembly (drawing
020–4500) with IR–TRACC (drawing
SA572–S37) (incorporated by reference,
see § 572.210) installed.
(b) When the thorax of a completely
assembled dummy (drawing 020–0100)
(incorporated by reference, see
§ 572.210) is impacted laterally by a test
probe conforming to § 572.219 at 5.0 ±
0.1 m/s (16.4 ± 0.3 ft/s) according to the
test procedure in paragraph (c) of this
section:
(1) Maximum lateral thorax
displacement (compression) relative to
the spine, measured with the IR–TRACC
(drawing SA572–S37) and processed as
set out in the PADI (all incorporated by
reference, see § 572.210), shall have a
value between 23 mm (0.91 in) and 28
mm (1.10 in). The peak force occurring
after 5 ms, measured by the impact
probe as defined in § 572.219 and
calculated in accordance with paragraph
(b)(2) of this section, shall have a value
between 1.38 kN (310 lbf) and 1.69 kN
(380 lbf).
(2) The force shall be calculated by
the product of the impactor mass and its
measured deceleration.
(3) Time zero is defined as the time
of contact between the impact probe and
the arm. All channels should be at a
zero level at this point.
(c) Test procedure: The test procedure
for the thorax with arm assembly is as
follows:
(1) The dummy is clothed in the Q3s
suit (drawing 020–8001) (incorporated
by reference, see § 572.210). No
additional clothing or shoes are placed
on the dummy.
(2) Soak the dummy in a controlled
environment at any temperature
between 20.6 and 22.2 ßC (69 and 72 ßF)
and a relative humidity from 10 to 70
percent for at least four hours prior to
a test.
(3) The test is carried out in the
direction opposing the primary load
vector of the ensuing full scale test for
which the dummy is being qualified. A
left thorax test set-up that is used to
qualify the dummy for an ensuing full
scale left side impact is depicted in
Figure W7. A right thorax set-up would
be a mirror image of that shown in
Figure W7. Seat the dummy on the
qualification bench described in Figure
V3 of 49 CFR 572.194, the seat pan and
seat back surfaces of which are covered
PO 00000
Frm 00030
Fmt 4701
Sfmt 4702
with thin sheets of PTFE (Teflon)
(nominal stock thickness: 2 to 3 mm (3/
32- to 1/8-inch)) along the impact side
of the bench.
(4) Position the dummy on the bench
as shown in Figure W7, with the ribs
making contact with the seat back
oriented 24.6 degrees relative to vertical,
the legs extended forward along the seat
pan oriented 21.6 degrees relative to
horizontal with the knees spaced 40 mm
(1.57 in) apart. On the non-impact side
of the dummy, the long axis of the
upper arm is positioned parallel to the
seat back (± 2 degrees). On the impact
side, the upper arm is positioned such
that the target point intersects its long
axis as described in (5) below. The long
axis of the upper arm is defined by
section line A–A in drawing 020–9750
(incorporated by reference, see
§ 572.210). Both of the lower arms are
set perpendicular to the upper arms.
(5) The target point of the impact is
the point of intersection on the lateral
aspect of the upper arm and a line
projecting from the thorax of the
dummy. The projecting line is
horizontal, runs parallel to the coronal
plane of the dummy, and passes through
the midpoint of a line connecting the
centers of the bolt heads of the two IR–
TRACC bolts (part #5000646). The
projected line should intersect the
upper arm within 2 mm (0.80 in) of its
long axis.
(6) Impact the arm with the test probe
so that at the moment of contact the
probe’s longitudinal centerline should
be horizontal (± 1 degrees), and the
centerline of the probe should be within
2 mm (0.80 in) of the target point.
(7) Guide the test probe during impact
so that there is no significant lateral,
vertical, or rotational movement.
(8) No suspension hardware,
suspension cables, or any other
attachments to the probe, including the
velocity vane, shall make contact with
the dummy during the test.
§ 572.216 Thorax without arm assembly
and test procedure.
(a) The thorax assembly for this test
consists of the torso assembly (drawing
020–4500) with IR–TRACC (drawing
SA572–S37) (incorporated by reference,
see § 572.210) installed.
(b) When the thorax of a completely
assembled dummy (drawing 020–0100)
with the arm (drawing 020–9700 or
020–9800) on the impacted side
removed is impacted laterally by a test
probe conforming to § 572.219 at 3.3 ±
0.1 m/s (10.8 ± 0.3 ft/s) according to the
test procedure in paragraph (c) of this
section:
(1) Maximum lateral thorax
displacement (compression) relative to
E:\FR\FM\21NOP2.SGM
21NOP2
tkelley on DSK3SPTVN1PROD with PROPOSALS2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
the spine, measured with the IR–TRACC
(drawing SA572–S37) and processed as
set out in the PADI (all incorporated by
reference, see § 572.210), shall have a
value between 24 mm (0.94 in) and 31
mm (1.22 in). The peak force, measured
by the impact probe as defined in
§ 572.219 and calculated in accordance
with paragraph (b)(2) of this section,
shall have a value between 620 N (139
lbf) and 770 N (173 lbf).
(2) The force shall be calculated by
the product of the impactor mass and its
measured deceleration.
(c) Test procedure: The test procedure
for the thorax without arm assembly is
as follows:
(1) The dummy is clothed in the Q3s
suit (drawing 020–8001) (incorporated
by reference, see § 572.210). No
additional clothing or shoes are placed
on the dummy.
(2) Soak the dummy in a controlled
environment at any temperature
between 20.6 and 22.2 °C (69 and 72 °F)
and a relative humidity from 10 to 70
percent for at least four hours prior to
a test.
(3) The test is carried out in the
direction opposing the primary load
vector of the ensuing full scale test for
which the dummy is being qualified. A
left thorax test set-up that is used to
qualify the dummy for an ensuing full
scale left side impact is depicted in
Figure W8. A right thorax set-up would
be a mirror image of that shown in
Figure W8. Seat the dummy on the
qualification bench described in Figure
V3 of 49 CFR 572.194, the seat pan and
seat back surfaces of which are covered
with thin sheets of PTFE (Teflon)
(nominal stock thickness: 2 to 3 mm
(3⁄32- to 1⁄8-inch)) along the impact side
of the bench.
(4) Position the dummy on the bench
as shown in Figure W8, with the ribs
making contact with the seat back
oriented 24.6 degrees relative to vertical,
the legs extended forward along the seat
pan oriented 21.6 degrees relative to
horizontal with the knees spaced 40 mm
(1.57 in) apart, and the arm on the nonimpacted side positioned so that the
upper arm is parallel (± 2 degrees) to the
seat back and the lower arm
perpendicular to the upper arm.
(5) The target point of the impact is
the midpoint of a line between the
centers of the bolt heads of the two IR–
TRACC bolts (part #5000646).
(6) Impact the thorax with the test
probe so that at the moment of contact
the probe’s longitudinal centerline
should be horizontal (± 1 degrees), and
the centerline of the probe should be
within 2 mm (0.08 in) of the target
point.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
(7) Guide the test probe during impact
so that there is no significant lateral,
vertical, or rotational movement.
(8) No suspension hardware,
suspension cables, or any other
attachments to the probe, including the
velocity vane, shall make contact with
the dummy during the test.
§ 572.217 Lumbar spine assembly and test
procedure.
(a) The lumbar spine and headform
assembly (refer to § 572.210(b)(2)(iv)
and § 572.210(a)(2)(vii)) for the purposes
of the fore-aft lumbar flexion and lateral
lumbar flexion qualification tests, as
shown in Figures W9 and W10, consists
of the headform (drawing 020–9050,
sheet 2) with angular rate sensor
installed (drawing SA572–S58), sixchannel neck/lumbar load cell (drawing
SA572–S8), lumbar spine assembly
(drawing 020–6000), lumbar interface
plate (drawing 020–9062) and
pendulum interface plate (drawing 020–
9051) with angular rate sensor installed
(drawing SA572–S58) (all incorporated
by reference, see § 572.210).
(b) When the lumbar spine and
headform assembly is tested according
to the test procedure in paragraph (c) of
this section, it shall have the following
characteristics:
(1) Fore-aft lumbar flexion
qualification test.
(i) Plane D, referenced in Figure W9,
shall rotate in the direction of preimpact flight with respect to the
pendulum’s longitudinal centerline
between 48 degrees and 57 degrees,
which shall occur between 52 and 59
ms from time zero. The peak moment,
measured by the neck/lumbar
transducer (drawing SA572–S8)
(incorporated by reference, see
§ 572.210) shall have a value between 78
N-m (57.5 ft-lbf) and 94 N-m (69.3 ft-lbf)
occurring between 46 and 57 ms from
time zero.
(ii) The decaying headform rotation
vs. time curve shall cross the zero angle
with respect to its initial position at
time of impact relative to the pendulum
centerline between 50 to 56 ms after the
time the peak rotation value is reached.
(iii) All instrumentation data channels
are defined to be zero when the
longitudinal centerline of the lumbar
spine and pendulum are parallel.
(iv) The headform rotation shall be
calculated by the following formula
with the integration beginning at time
zero:
Headform rotation (deg) = ∫ [(Headform
Angular Rate)y ¥ (Pendulum
Angular Rate)y] dt
(v) (Headform Angular Rate)y is the
angular rate about the y-axis in deg/sec
measured on the headform (drawing
PO 00000
Frm 00031
Fmt 4701
Sfmt 4702
69973
020–9050, sheet 2), and (Pendulum
Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the
pendulum interface plate (drawing 020–
9051) (all incorporated by reference, see
§ 572.210).
(2) Lateral lumbar flexion
qualification test.
(i) Plane D, referenced in Figure W10,
shall rotate in the direction of preimpact flight with respect to the
pendulum’s longitudinal centerline
between 47 degrees and 59 degrees,
which shall occur between 50 and 59
ms from time zero. The peak moment,
measured by the neck/lumbar
transducer (drawing SA572–S8)
(incorporated by reference, see
§ 572.210) shall have a value between 78
N-m (57.5 ft-lbf) and 97 N-m (71.5 ft-lbf)
occurring between 46 and 57 ms from
time zero.
(ii) The decaying headform rotation
vs. time curve shall cross the zero angle
with respect to its initial position at
time of impact relative to the pendulum
centerline between 47 to 59 ms after the
time the peak rotation value is reached.
(iii) All instrumentation data channels
are defined to be zero when the
longitudinal centerline of the lumbar
spine and pendulum are parallel.
(iv) The headform rotation shall be
calculated by the following formula
with the integration beginning at time
zero:
Headform rotation (deg) = ∫ [(Headform
Angular Rate)y¥(Pendulum
Angular Rate)y] dt
(v) (Headform Angular Rate)y is the
angular rate about the y-axis in deg/sec
measured on the headform (drawing
020–9050, sheet 2), and (Pendulum
Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the
pendulum interface plate (drawing 020–
9051) (all incorporated by reference, see
§ 572.210).
(c) Test procedure: The test procedure
for the lumbar spine assembly is as
follows:
(1) Soak the lumbar spine assembly in
a controlled environment at any
temperature between 20.6 and 22.2 °C
(69 and 72 °F) and a relative humidity
between 10 and 70 percent for at least
four hours prior to a test.
(2)(i) For the fore-aft lumbar flexion
test, mount the lumbar spine and
headform assembly, defined in
subsection (a) of this section, on the
pendulum described in Figure 22 of 49
CFR 572 so that the midsagittal plane of
the headform is vertical and coincides
with the plane of motion of the
pendulum, and with the lumbar spine
placement such that the front side of the
lumbar spine is closest to the
honeycomb material.
E:\FR\FM\21NOP2.SGM
21NOP2
69974
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
(ii) For the lateral lumbar flexion test,
the test is carried out in the direction
opposing the primary load vector of the
ensuing full scale test for which the
dummy is being qualified. A right
flexion test set-up that is used to qualify
the dummy for an ensuing a full scale
right side impact is depicted in Figure
W10. A left flexion test set-up would be
a mirror image of that shown in Figure
W10. Mount the lumbar spine and
headform assembly, defined in
subsection (a)(1) of this section, on the
pendulum described in Figure 22 of 49
CFR 572 so that the midsagittal plane of
the headform is vertical and coincides
with the plane of motion of the
pendulum, and with the lumbar spine
placement such that the right (or left)
side of the lumbar spine is closest to the
honeycomb material.
(3)(i) Release the pendulum and allow
it to fall freely from a height to achieve
an impact velocity of 4.4 ± 0.1 m/s (14.4
± 0.3 ft/s), measured by an
accelerometer mounted on the
pendulum as shown in Figure 22 of this
Part 572 at time zero.
(ii) Stop the pendulum from the
initial velocity with an acceleration vs.
time pulse that meets the velocity
change as specified in Table C of this
section. Integrate the pendulum
accelerometer data channel to obtain the
velocity vs. time curve beginning at time
zero.
TABLE C TO § 572.217
Fore-aft flexion
Lateral flexion
Time (ms)
m/s
10 .....................................................................................................................................
20 .....................................................................................................................................
30 .....................................................................................................................................
tkelley on DSK3SPTVN1PROD with PROPOSALS2
§ 572.218 Pelvis assembly and test
procedure.
(a) The pelvis assembly (drawing 020–
7500) for this test includes a uniaxial
pubic load cell (drawing SA572–S7)
installed on the non-impact side of the
pelvis (all incorporated by reference, see
§ 572.210).
(b) When the center of the pelvis of a
completely assembled dummy (drawing
020–0100) (incorporated by reference,
see § 572.210) is impacted laterally by a
test probe conforming to § 572.219 at 4.0
± 0.1 m/s (13.1 ± 0.3 ft/s) according to
the test procedure in paragraph (c) of
this section:
(1) Maximum pubic load, measured
with the uniaxial pubic load cell
(drawing SA572–S7) (incorporated by
reference, see § 572.210), shall have a
value between 700 N (157 lbf) and 870
N (196 lbf). The peak force, measured by
the impact probe as defined in § 572.219
and calculated in accordance with
paragraph (b)(2) of this section, shall
have a value between 1.57 kN (353 lbf)
and 1.81 kN (407 lbf).
(2) The force shall be calculated by
the product of the impactor mass and its
measured deceleration.
(c) Test procedure: The test procedure
for the pelvis assembly is as follows:
(1) The dummy is clothed in the Q3s
suit (drawing 020–8001) (incorporated
by reference, see § 572.210). No
additional clothing or shoes are placed
on the dummy.
(2) Soak the dummy in a controlled
environment at any temperature
between 20.6 and 22.2 °C (69 and 72 °F)
and a relative humidity from 10 to 70
percent for at least four hours prior to
a test.
(3) The pelvis test is carried out in the
direction opposing the primary load
vector of the ensuing full scale test for
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
1.3–1.7
2.7–3.7
4.1–4.9
which the dummy is being qualified. A
left pelvis test set-up that is used to
qualify the dummy for an ensuing full
scale left side impact is depicted in
Figure W11. A right pelvis test set-up
would be a mirror image of that shown
in Figure W11. Seat the dummy on the
qualification bench described in Figure
V3 of 49 CFR 572.194, the seat pan and
seat back surfaces of which are covered
with thin sheets of PTFE (Teflon)
(nominal stock thickness: 2 to 3 mm
(3⁄32- to 1⁄8-inch)) along the impact side
of the bench.
(4) Position the dummy on the bench
as shown in Figure W11, with the ribs
making contact with the seat back
oriented 24.6 degrees relative to vertical,
the legs extended forward along the seat
pan oriented 21.6 degrees relative to
horizontal with the knees spaced 40 mm
(1.57 in) apart. The arms should be
positioned so that the arm on the nonimpacted side is parallel to the seat back
with the lower arm perpendicular to the
upper arm, and the arm on the impacted
side is positioned upwards away from
the pelvis.
(5) Establish the impact point at the
center of the pelvis so that the impact
point of the longitudinal centerline of
the probe is located 185 mm (7.28 in)
from the center of the knee pivot screw
(part #020–9008) and centered vertically
on the femur.
(6) Impact the pelvis with the test
probe so that at the moment of contact
the probe’s longitudinal centerline
should be horizontal (± 1 degrees), and
the centerline of the probe should be
within 2 mm (0.08 in) of the center of
the pelvis.
(7) Guide the test probe during impact
so that there is no significant lateral,
vertical, or rotational movement.
PO 00000
Frm 00032
Fmt 4701
Sfmt 4702
ft/s
4.3–5.6
8.9–12.1
13.5–16.1
m/s
1.3–1.7
2.7–3.7
4.0–4.8
ft/s
4.3–5.6
8.9–12.1
13.1–15.7
(8) No suspension hardware,
suspension cables, or any other
attachments to the probe, including the
velocity vane, shall make contact with
the dummy during the test.
§ 572.219 Test conditions and
instrumentation.
(a) The following test equipment and
instrumentation is needed for
qualification as set forth in this subpart:
(1) The test probe for shoulder,
thorax, and pelvis impacts is of rigid
metallic construction, concentric in
shape, and symmetric about its
longitudinal axis. It has a mass of 3.81
± 0.02 kg (8.40 ± 0.04 lb) and a
minimum mass moment of inertia of
560 kg-cm2 (0.407 lbf-in-sec2) in yaw
and pitch about the CG. One-third (1⁄3)
of the weight of the suspension cables
and their attachments to the impact
probe is included in the calculation of
mass, and such components may not
exceed five percent of the total weight
of the test probe. The impacting end of
the probe, perpendicular to and
concentric with the longitudinal axis, is
at least 25.4 mm (1.0 in) long, and has
a flat, continuous, and non-deformable
70.0 ± 0.25 mm (2.76 ± 0.01 in) diameter
face with an edge radius between 6.4–
12.7 mm (0.25 to 0.5 in). The probe’s
end opposite to the impact face has
provisions for mounting of an
accelerometer with its sensitive axis
collinear with the longitudinal axis of
the probe. No concentric portions of the
impact probe may exceed the diameter
of the impact face. The impact probe
shall have a free air resonant frequency
of not less than 1000 Hz, which may be
determined using the procedure listed
in the PADI.
(2) Head accelerometers have
dimensions, response characteristics,
E:\FR\FM\21NOP2.SGM
21NOP2
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
tkelley on DSK3SPTVN1PROD with PROPOSALS2
and sensitive mass locations specified
in drawing SA572–S4 and are mounted
in the head as shown in drawing 020–
0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(3) The upper neck force and moment
transducer has the dimensions, response
characteristics, and sensitive axis
locations specified in drawing SA572–
S8 and is mounted in the head-neck
assembly as shown in drawing 020–
0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(4) The angular rate sensors for the
fore-aft neck flexion and lateral neck
flexion qualification tests have the
dimensions and response characteristics
specified in drawing SA572–S58
(incorporated by reference, see
§ 572.210) and are mounted in the
headform and on the pendulum as
shown in Figures W3, W4 of this
subpart.
(5) The string pot shoulder deflection
transducers have the dimensions and
response characteristics specified in
drawing SA572–S38 or SA572–S39 and
are mounted to the torso assembly as
shown in drawing 020–0100, sheet 2 of
5 (all incorporated by reference, see
§ 572.210).
(6) The IR–TRACC thorax deflection
transducers have the dimensions and
response characteristics specified in
drawing SA572–S37 and are mounted to
the torso assembly as shown in drawing
020–0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(7) The lumbar spine force and
moment transducer has the dimensions,
response characteristics, and sensitive
axis locations specified in drawing
SA572–S8 and is mounted in the torso
assembly as shown in drawing 020–
0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(8) The angular rate sensors for the
fore-aft lumbar flexion and lateral
lumbar flexion qualification tests have
the dimensions and response
characteristics specified in drawing
SA572–S58 (incorporated by reference,
see § 572.210) and are mounted in the
headform and on the pendulum as
shown in Figures W9, W10 of this
subpart.
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
(9) The pubic force transducers have
the dimensions and response
characteristics specified in drawing
SA572–S7 and are mounted in the torso
assembly as shown in drawing 020–
0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(b) The following instrumentation
may be required for installation in the
dummy for compliance testing. If so, it
is installed during qualification
procedures as described in this subpart:
(1) The optional angular rate sensors
for the head have the dimensions and
response characteristics specified in any
of drawings SA572–S55, SA572–S56,
SA572–S57 or SA572–S58 and are
mounted in the head as shown in
drawing 020–0100, sheet 2 of 5 (all
incorporated by reference, see
§ 572.210).
(2) The upper spine accelerometers
have the dimensions, response
characteristics, and sensitive mass
locations specified in drawing SA572–
S4 and are mounted in the torso
assembly as shown in drawing 020–
0100, sheet 2 of 5 (all incorporated by
reference, see § 572.210).
(3) The pelvis accelerometers have the
dimensions, response characteristics,
and sensitive mass locations specified
in drawing SA572–S4 and are mounted
in the torso assembly as shown in
drawing 020–0100, sheet 2 of 5 (all
incorporated by reference, see
§ 572.210).
(4) The T1 accelerometer has the
dimensions, response characteristics,
and sensitive mass location specified in
drawing SA572–S4 and is mounted in
the torso assembly as shown in drawing
020–0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(5) The lower neck force and moment
transducer has the dimensions, response
characteristics, and sensitive axis
locations specified in drawing SA572–
S8 and is mounted to the neck assembly
as shown in drawing 020–0100, sheet 2
of 5 (incorporated by reference, see
§ 572.210).
(6) The tilt sensor has the dimensions
and response characteristics specified in
drawing SA572–S44 and is mounted to
the torso assembly as shown in drawing
PO 00000
Frm 00033
Fmt 4701
Sfmt 4702
69975
020–0100, sheet 2 of 5 (incorporated by
reference, see § 572.210).
(c) The outputs of transducers
installed in the dummy and in the test
equipment specified by this part are to
be recorded in individual data channels
that conform to SAE Recommended
Practice J211 (incorporated by reference,
see § 572.210) except as noted, with
channel frequency classes as follows:
(1) Pendulum acceleration, CFC 180,
(2) Pendulum angular rate, CFC 60,
(3) Neck twist fixture rotation, CFC
60,
(4) Test probe acceleration, CFC 180,
(5) Head accelerations, CFC 1000,
(6) Headform angular rate, CFC 60,
(7) Neck moments, upper and lower,
CFC 600,
(7) Shoulder deflection, CFC 180,
(8) Thorax deflection, CFC 180,
(9) Upper spine accelerations, CFC
180,
(10) T1 acceleration, CFC 180,
(11) Pubic force, CFC 180,
(12) Pelvis accelerations, CFC 1000.
(d) Coordinate signs for
instrumentation polarity are to conform
to SAE Information Report J1733
(incorporated by reference, see
§ 572.210).
(e) The mountings for sensing devices
have no resonant frequency less than 3
times the frequency range of the
applicable channel class.
(f) Limb joints are set at one G, barely
restraining the weight of the limb when
it is extended horizontally. The force
needed to move a limb segment is not
to exceed 2G throughout the range of
limb motion.
(g) Performance tests of the same
component, segment, assembly, or fully
assembled dummy are separated in time
by not less than 30 minutes unless
otherwise noted.
(h) Surfaces of dummy components
may not be painted except as specified
in this subpart or in drawings subtended
by this subpart.
BILLING CODE 4910–59–P
Appendix—Figures to Subpart W of
Part 572
E:\FR\FM\21NOP2.SGM
21NOP2
69976
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
Figure WI
FRONTAL HEAD DROP TEST SET-UP SPECIFICATIONS
QUlCKRELEASE
Z-AXIS OF TIlE HEAD
(PARALLEL TO
SKULL CAP PLANE)
HEAD SUSPENSION
CABLES
HEAD COMPLETE
(020-1200)
WITH HEAD
ACCELEROMETER ASS'Y.
(020-1013A)
376±lmm
~--------------~--~
s=~rnj
MEDIAL-LATERAl
AXIS MUST BE
HORIZONTAL
WITH1N 1°
50.8 x 610mm x 610mm
(2 x 24 x 24 in)
IMPACT SURFACE
FINISH
203 to 2032 ~mm
(8 to 80 RMS ~in)
HALF LOAD CELL
BLANK
(PART #020-1050)
376±lmm
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
PO 00000
~I-------------------
Frm 00034
Fmt 4701
Sfmt 4725
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.002
tkelley on DSK3SPTVN1PROD with PROPOSALS2
L
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
69977
FigureW2
LATERAL HEAD DROP TEST SET-UP SPECIFICATIONS
HEAD SUSPENSION
CABLES
QUICK RELEASE
HALF LOAD CELL
HEAD COMPLETE
(020-1200)
BLANK
(PART #020-1050)
WITH HEAD
ACCELEROMETER ASS'Y.
HEAD BASE
PLANE
(PARALLEL
(020-1013A)
TO THE HALF
LOAD CELL
BLANK)
l
200±1m.m
L_-----"___
STEEL PLATE
50.8 x 61Om.m x 610mm
(2x24x24in)
IMPACT SURFACE
FINISH
203 to 2032 p.mmImm
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
PO 00000
Frm 00035
Fmt 4701
Sfmt 4725
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.003
tkelley on DSK3SPTVN1PROD with PROPOSALS2
(8 to 80 RMS ~in)
69978
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
ANGULAR RATE
SENSOR
(PART #SA:5I2-SS8)
PENDULUM INTERFACE
PLATE
(PART 0020-90:51)
NECK ASSEMBLY
(PART ""~,V-,,"""=
NOTICE
PLACEMENT DIRECTION
(BOLTED iN
REAR
SET OF MOUNTING HOLES)
NECKtTORSO
INTERFACE PLII"TE
NECK/LUMBAR
#020-90:56)
LOADCEtL
(PART #SA:572-S8)
ANGULAR RATE
PE,RPENDICULAR
TO CENTER LINE
OF PENDlJLU~'(
SENSOR
#SA512-S:58)
HEADFORM
ANGULAR RATE
(PART #020-90:50)
SENSOR MOUNT
FigureW4
NECK LATERAL FLEXION TEST SPECIFICATIONS
DIRECTION OF
...
MOTION _ - - - - - .
PART 512 SUBPART E
PENDULUM (FIGURE #22)
ANGULAR RATE
SENSOR
(PART #SA571-s5S) ...."--_ _--'1
PENDULUM INTERFACE
PLATE
(PART #O20·9{}51)
NECKASSRMBLY
(PART 11020-24(0)
NOTICE NECK
PLACEMENT DlRECTION
(BOLTED IN TIm FROm
SET OF MOUNTING HOLES)
NECKITORSO
INTERFACE PLATE
(PART#02O-90S6)
NBCKILUMBAR
LOAD CELL
(PAIlT #SA5n·SS)
ANGULAR RATE
SENSOR
(pART #SA5n-ssS)
DPLANE --PERPENDICULAR
TO CENTER LINE
OF PENDULUM
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
ANGULAR RATE
SENSOR MOUNT
PO 00000
Frm 00036
Fmt 4701
Sfmt 4725
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.004
tkelley on DSK3SPTVN1PROD with PROPOSALS2
HEADFORM
(PART #O20-9{}50)
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
69979
PART 572 SUBPART E
I}ENDULUM (FIGURE
NECK ASSEMBLY
(PART #020-24(0)
ROT/tRY
POTENTIOMETER
{PART #SA572-..~51:
TWIST .FIXTUR.E
BNDPlATE
(PART IIDL210-21O)
NECK TltVI:";T FiXTURE
(PART #DI,21O-1(0)
NECKlL'UMfti\R
LOAD CELL
(P.A1U
•
NECK ADAPTER l'l~ATE
(PART IIDUI0-220)
D
D
W6
SHOULDERTMPACT
If..fPACT PROBE \-lEIGHT = 3J';5 0.02 Kg
INSTRUMENTATION
OF THE CABLE ""'EIGHT
ARMALlGNED
WITH THORAX
CENTER AXIS OF PROBE
IS IN-tiNE WITH
OF SHOULDER .IOlNT
40 mm BETIVEEN
KNEES V,,1TI:1
PARALLEL
-__i _.
_
--
QUALIFICATION BENCH
REF, FIG. V3
CFR 49 572.194
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
PO 00000
Frm 00037
Fmt 4701
Sfmt 4725
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.005
tkelley on DSK3SPTVN1PROD with PROPOSALS2
VlE\V"A"
69980
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
IMPACT liROBE
SUPPORT CABLES
IMPACT PROB.!': WEIGHT = 3,85 ±
Kg
INCLUDING ALL INSTRUMENTATION
AND
OF THE CA.BLE \VEIGHT
ALIGNED
WITH THORA"",\:
VIE\\,' "A"
CENTER AXIS DF PROBE
is CE'I\l'TERED
BETWEEN
KNEES "VITH
LEGS ",'~j"',M,J"'~,I'L,
'THE IR..:rRACC
ATIACIL"vfENT
BOLTS ON
RrBCAGE
4() nun
--~
24,6"
VIEW "A"
QUALifiCATION BENCH
REF, FIG, V3
CFR 49
572.194
LATERAL THORAX IMPACT - WITHOUT ARM
Hv'I.PACT PROBE
SUPPORt' CABU~:S
IMPACT PROBE WEIGHT = 3.85 ±
Kg
INCLUDING ALL INSTRUMENTATION
c\ND
OF THE CABtE WEIGHT
VIEW "A"
40
BET\VEEN KNEES _ _
~
CENTER AXIS OF PROBE
lS CENTERED BETWEEN
THE IR-TRACC
ATIACHMENT
ROLTSON
THE RIBCAGE
WITH LE:GS PARAU.. EL
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
QUALIFICATION BENCH
REF. FIG, '1/3
CFR49
PO 00000
Frm 00038
Fmt 4701
Sfmt 4725
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.006
tkelley on DSK3SPTVN1PROD with PROPOSALS2
VIEW "A"
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
69981
PARI 572 SllBPART E
PfNDUUJM
FI:INDULUM
PLATE
ANGULAR RATE
SENSOR
(PART #020-9(51)
LIJMBAR SPINE ASS.EII,mty
(pART ""'<'J-"'''''''1
- NECKlLlJMBAR
(PART #SA572-S:58)
LOAD CELL
NOTICE
(FART
PLACEME.NT DIRECTION
SET
(BOLTED
THE REAR
MOUNTING HOLES)
PLANE --"-PERPBNDlCULAR
ANGULAR RATE
SENSOR
TO CENTER LINE
Of PENDULUM
#SAS12-SS8)
HEADFORM
ANGULAR IV\'TE
(PART #020-9(50)
SENSOR MOLINT
FigureWlO
LUMBAR LATERAL FLEXION TEST SPECIFICATIONS
DUCTION OF
MOTION
...
NECK\LUMBAR
LOADCBLL
(PART #SASn.sS)
LUMBAR SPINE ASSEMBLY
(pART #020-6000)
NOTICE LUMBAR
ATTACHMENT TO
HBADFORM
(BOLTED IN TIm FRONT
SET OF MOUNTING HOLES)
PENDULUMlNTBRFACE
PLATE
(pART #020-9(51)
DPLANE
PERPENDICULAR
TOCBNTBRLINE
OFPBNDULUM
VerDate Mar<15>2010
17:18 Nov 20, 2013
HBADFORM
(PART #020-9050)
Jkt 232001
PO 00000
Frm 00039
Fmt 4701
Sfmt 4725
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.007
tkelley on DSK3SPTVN1PROD with PROPOSALS2
ANGULAR RATE
SENSOR
(pART ffSA572.s5S)
69982
Federal Register / Vol. 78, No. 225 / Thursday, November 21, 2013 / Proposed Rules
Issued on: November 8, 2013.
Christopher J. Bonanti,
Associate Administrator for Rulemaking.
[FR Doc. 2013–27438 Filed 11–20–13; 8:45 am]
VerDate Mar<15>2010
17:18 Nov 20, 2013
Jkt 232001
PO 00000
Frm 00040
Fmt 4701
Sfmt 9990
E:\FR\FM\21NOP2.SGM
21NOP2
EP21NO13.008
tkelley on DSK3SPTVN1PROD with PROPOSALS2
BILLING CODE 4910–59–C
Agencies
[Federal Register Volume 78, Number 225 (Thursday, November 21, 2013)]
[Proposed Rules]
[Pages 69943-69982]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2013-27438]
[[Page 69943]]
Vol. 78
Thursday,
No. 225
November 21, 2013
Part II
Department of Transportation
-----------------------------------------------------------------------
National Highway Traffic Safety Administration
-----------------------------------------------------------------------
49 CFR Part 572
Anthropomorphic Test Devices; Q3s 3-Year-Old Child Side Impact Test
Dummy, Incorporation by Reference; Proposed Rule
Federal Register / Vol. 78 , No. 225 / Thursday, November 21, 2013 /
Proposed Rules
[[Page 69944]]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
National Highway Traffic Safety Administration
49 CFR Part 572
[Docket No. NHTSA-2013-0118]
RIN 2127-AL04
Anthropomorphic Test Devices; Q3s 3-Year-Old Child Side Impact
Test Dummy, Incorporation by Reference
AGENCY: National Highway Traffic Safety Administration (NHTSA),
Department of Transportation (DOT).
ACTION: Notice of proposed rulemaking (NPRM).
-----------------------------------------------------------------------
SUMMARY: This document proposes to amend our regulations to add
specifications and qualification requirements for an anthropomorphic
test device (ATD) representing a 3-year-old child, called the ``Q3s''
side impact test dummy. The agency plans to use the Q3s to test child
restraint systems to new side impact performance requirements which
NHTSA will propose to adopt into the Federal motor vehicle safety
standard for child restraint systems by way of a separate NPRM.
Adopting side impact protection requirements is consistent with a
statutory provision set forth in the ``Moving Ahead for Progress in the
21st Century Act'' (July 6, 2012), that the agency issue a final rule
to improve the protection of children seated in child restraint systems
during side impacts.
DATES: You should submit your comments early enough to ensure that
Docket Management receives them not later than January 21, 2014.
Proposed effective date: The CFR would be amended on the date 60 days
after date of publication of the final rule.
ADDRESSES: You may submit comments to the docket number identified in
the heading of this document by any of the following methods:
Federal eRulemaking Portal: Go to https://www.regulations.gov. Follow the online instructions for submitting
comments.
Mail: Docket Management Facility, M-30, U.S. Department of
Transportation, West Building, Ground Floor, Rm. W12-140, 1200 New
Jersey Avenue SE., Washington, DC 20590.
Hand Delivery or Courier: West Building Ground Floor, Room
W12-140, 1200 New Jersey Avenue SE., between 9 a.m. and 5 p.m. Eastern
Standard Time, Monday through Friday, except Federal holidays.
Fax: (202) 493-2251.
Regardless of how you submit your comments, you should mention the
docket number of this document.
You may call the Docket at 202-366-9324.
Instructions: For detailed instructions on submitting comments and
additional information on the rulemaking process, see the Public
Participation heading of the Supplementary Information section of this
document. Note that all comments received will be posted without change
to https://www.regulations.gov, including any personal information
provided. Please see the Privacy Act discussion below.
Privacy Act: Anyone is able to search the electronic form of all
comments received into any of our dockets by the name of the individual
submitting the comment (or signing the comment, if submitted on behalf
of an association, business, labor union, etc.). You may review DOT's
complete Privacy Act Statement in the Federal Register published on
April 11, 2000 (65 FR 19477-78).
FOR FURTHER INFORMATION CONTACT: For technical issues: Peter Martin,
NHTSA Office of Crashworthiness Standards (telephone 202-366-5668) (fax
202-493-2990). For legal issues: Deirdre Fujita, NHTSA Office of Chief
Counsel (telephone 202-366-2992) (fax 202-366-3820). Mailing address:
National Highway Traffic Safety Administration, U.S. Department of
Transportation, 1200 New Jersey Avenue SE., West Building, Washington,
DC 20590.
SUPPLEMENTARY INFORMATION:
Table of Contents
I. Introduction
II. Background
a. Evolution of the Dummy
b. Developments
c. Build Level D
III. Description
a. General Construction
b. Instrumentation
IV. Biofidelity
a. Anthropometry
b. Biofidelity Assessment Under Dynamic Loading
V. Repeatability and Reproducibility
a. R&R in Sled Tests
b. R&R in Component Qualification Tests
VI. Qualification Tests
a. Overview of Proposed Corridors
b. Rationale for the Tests
c. New and Modified Part 572 Tests and Equipment
d. Proposed Test Specifications and Performance Requirements
VII. Durability
a. High-Energy Component Tests
b. Q3s Servicing and Maintenance
VIII. Drawings and Patents
IX. Consideration of Alternatives
X. Rulemaking Analyses and Notices
XI. Public Participation
I. Introduction
This document proposes to amend 49 CFR Part 572 to add
specifications and qualification requirements for a test dummy
representing a 3-year-old child, called the ``Q3s'' side impact test
dummy. The Q3s is a modified version of a European side impact dummy.
In accordance with the ``Moving Ahead for Progress in the 21st Century
Act'' (MAP-21) (Pub. L. 112-141), NHTSA will be issuing a proposal,
which we expect to publish shortly, to amend Federal Motor Vehicle
Safety Standard (FMVSS) No. 213, ``Child restraint systems'' (49 CFR
571.213), to adopt side impact protection requirements for child
restraints.\1\ The agency is considering a proposal that incorporates
the Q3s in the side impact compliance test procedure.
---------------------------------------------------------------------------
\1\ Subtitle E of MAP-21, entitled ``Child Safety Standards,''
includes Sec. 31501(a) which states that, not later than 2 years
after the date of enactment of the Act, the Secretary shall issue a
final rule amending Federal Motor Vehicle Safety Standard Number 213
to improve the protection of children seated in child restraint
systems during side impact crashes.
---------------------------------------------------------------------------
This document proposes to incorporate specifications and
qualification requirements for the Q3s into 49 CFR Part 572,
``Anthropomorphic test devices.'' The Q3s would be specified in a new
subpart W. This NPRM proposes incorporating by reference a parts list,
a set of design drawings, and a ``Procedures for Assembly, Disassembly
and Inspection (PADI)'' document, to ensure that all Q3s dummies are
the same in their design and construction.\2\ Subpart W of 49 CFR Part
572 would specify performance tests that serve to assure that the Q3s
responses are within the established qualification corridors and
further assure the uniformity of dummy assembly, structural integrity,
consistency of response, and adequacy of instrumentation. These
specifications ensure the repeatability and reproducibility of the
dummy's impact response in child restraint compliance tests.
---------------------------------------------------------------------------
\2\ Drawings and the PADI for the Q3s are available for
examination in the docket for this NPRM.
---------------------------------------------------------------------------
The agency plans to propose adding a side impact test to FMVSS No.
213, one in which child restraint systems (CRSs) sold for children
weighing up to 18 kilograms (kg) (40 pounds (lb)) must protect the
child occupant in a dynamic sled test simulating a vehicle-to-vehicle
side impact.\3\ We are considering using
[[Page 69945]]
the Q3s to test child restraints recommended for children in a weight
range that includes 10 kg to 18 kg (22 to 40 lb). Among other things,
we are considering a proposal that would require those child restraints
to limit the risk of head and chest injury to children in a side
impact. We are considering using the Q3s to measure the risk of head
injury by way of a head injury criterion (HIC) (computed within a
specified timeframe, e.g., 15 millisecond (ms) (HIC15)), and the risk
of chest injury using thorax deflection as a criterion.
---------------------------------------------------------------------------
\3\ A discussion of NHTSA's research evaluating and developing
the side impact test procedure can be found in Sullivan et al.,
``NHTSA's Evaluation of a Potential Child Side Impact Test
Procedures,'' 22nd International Technical Conference on the
Enhanced Safety of Vehicles, Paper No. 2011-0227 (2011).
---------------------------------------------------------------------------
NHTSA seeks to adopt side impact protection requirements in FMVSS
No. 213 that would be evaluated in a dynamic test simulating an actual
vehicle crash. Our goal has been to use an anthropomorphic test device
(ATD) that has a sound biofidelic response under lateral loading, with
internal instrumentation sufficient to record injurious body loads. We
seek to adopt an ATD that is suitable for use in regulatory tests with
demonstrated repeatability, reproducibility, and durability. Within a
test laboratory, the ATD would be practical to handle and maintain. The
dummy would be available at a reasonable cost.
The Q3s test dummy appears to have all of the above attributes. As
discussed in this NPRM, NHTSA is satisfied with the overall biofidelity
of the Q3s and we have found that it exhibits repeatable and
reproducible performance in CRS side impact sled testing and in
component-level qualification testing. The Q3s demonstrates sufficient
durability in high-energy qualification tests and in CRS side impact
sled testing. The agency has tentatively concluded that the dummy is a
reliable test device that will provide valuable data in assessing the
potential for injury in side impacts and is suitable for incorporation
into Part 572.
II. Background
a. Evolution of the Dummy
The Q3s evolved from predecessor P-series test dummies developed by
the Netherlands Organization for Applied Scientific Research (TNO). The
P-series first was introduced into European CRS standards in 1981 with
the adoption of United Nations Economic Commission for Europe (UNECE)
Regulation No. 44, ``Uniform Provisions Concerning the Approval of
Restraining Devices for Child Occupants of Power-Driven Vehicles (Child
Restraint Systems).'' Initially, the P-series of dummies served only as
CRS loading devices to assure CRS integrity in a frontal dynamic sled
test.
In 1993, the European Commission formed a child dummy working group
to develop a successor series of dummies called the Q-series. It was
envisioned that the Q-series dummies would be used in frontal and side
impact tests, and would be more anthropometrically correct than the P-
series, and instrumented to enable injury assessment for the head,
neck, and chest. The conceptual dummy design was led by TNO, while
working group members as a whole established the anthropometry,
biofidelity, and measurement requirements for the new Q-series. In late
1997, the specifications for the first dummy of the Q-series, the
three-year-old version known as the ``Q3,'' were reported by TNO.
In 1999, a dummy manufacturer then named First Technology Safety
Systems (FTSS) \4\ acquired the dummy development and manufacturing
business of TNO. At that time, testing indicated that the Q3 dummy's
performance was suboptimal in frontal testing and even more so in
lateral.\5\ Around 2001, FTSS initiated the design cycle for the Q3s,
which was an improved side impact version of the Q3.
---------------------------------------------------------------------------
\4\ In 2010, FTSS was merged into a new company, Humanetics
Innovative Solutions (Humanetics). In this preamble, when we discuss
work done by the company prior to 2010, we use the name FTSS. When
we refer to the company's activities after 2010, we will refer to
the name ``Humanetics.''
\5\ The Q3 was assessed in: Berliner et al. (2000), Comparative
evaluation of the Q3 and Hybrid III 3-Year-Old dummies in
biofidelity and static out-of-position airbag tests, Stapp Car Crash
Journal, V44: 25-50. Since the Q3 had yet to show it was suitable
for side impact testing, NHTSA chose to use the HIII-3C in child
restraint side impact testing the agency conducted following on the
Transportation Recall Enhancement, Accountability and Documentation
Act of 2000 (TREAD Act). The testing led up to an advance notice of
proposed rulemaking (ANPRM) which NHTSA published on May 2, 2002, 67
FR 21836.
---------------------------------------------------------------------------
In early 2002, NHTSA tested a prototype version of the Q3s.\6\
NHTSA evaluated this Q3s unit using qualification-style pendulum and
impactor tests to assess functionality, durability, and biofidelity. We
determined that the thorax of the prototype appeared biofidelic and
repeatable, but the shoulder and pelvis were much too stiff. Moreover,
the neck was a single-piece rubber column (i.e., it was not segmented
by aluminum discs as is typical in other dummy necks), and we found its
biofidelity to be marginal in frontal and lateral flexion. In our
tests, we observed that the rubber neck material tended to bunch
together at maximum flexion, which appeared to improperly restrict the
neck bending.
---------------------------------------------------------------------------
\6\ The unit was a modified Q3 that NHTSA had owned.
---------------------------------------------------------------------------
Other organizations acquiring prototype Q3s units included
Transport Canada and Takata Holdings (Takata). Transport Canada
explored the biofidelity of the Q3s through impacts delivered by
pendulums and impactor testing. Takata exercised the dummy by
performing several sets of sled tests with the ATD seated within a
CRS.\7\ Both Transport Canada and Takata found problems with their Q3s
units similar to those found by NHTSA. These problems were conveyed to
FTSS through public critiques, and through committee meetings of the
International Organization for Standardization (ISO) and SAE
International (SAE).\8\
---------------------------------------------------------------------------
\7\ Takata was developing a ``sled-on-sled'' test methodology.
Takata was also involved with the International Organization for
Standardization (ISO) and UNECE Reg. No. 44 committees on CRS sled
test development, and for this purpose Takata also tested the P3,
Q3, and the HIII-3C on its sled system.
\8\ ISO is a worldwide standards-setting organization. The Q3s
dummy was discussed in the meetings of ISO Technical Committee TC
22, Road vehicles, Subcommittee SC 12, Passive safety crash
protection systems. SAE is also a worldwide standards-setting
organization.
---------------------------------------------------------------------------
Meanwhile, SAE developed new biofidelity response targets for
child-sized side impact ATDs, including a three-year-old child dummy,
to support work on side impact protection for children.\9\ The new
child targets were determined by scaling adult biofidelity targets
previously established by ISO.\10\ These targets became a new set of
criteria for FTSS to incorporate into the dummy design, in addition to
solving the functionality and durability problems noted by NHTSA and
the other organizations.
---------------------------------------------------------------------------
\9\ The work of SAE to establish biofidelity targets for child
ATDs was overseen by the Biomechanics and Simulation Standards
Committee. The targets and methodologies are published in Irwin AL,
Mertz HJ, Elhagediab AM, Moss S (2002), Guidelines for Assessing
Biofidelity of Side Impact Dummies of Various Sizes and Ages. Stapp
Car Crash Journal V46: 297-319.
\10\ ISO/TR 9790:1999 Road vehicles--Anthropomorphic side impact
dummy--Lateral impact response requirements to assess the
biofidelity of the dummy.
---------------------------------------------------------------------------
FTSS continued to work on the Q3s and in April 2006, released the
Q3s Build Level A, its first production version of a new, Q3s-specific
design. Within a year, several additional upgrades were incorporated
into the design and by July 2007 Build Level C was released.
b. Developments
In 2007, the Occupant Safety Research Partnership (OSRP),\11\
together with
[[Page 69946]]
Transport Canada (TC), tested Q3s Build Level C units to evaluate the
biofidelity and durability of the dummy, as did NHTSA. Extensive
testing was conducted to evaluate the biofidelity of the head, neck,
shoulder, thorax, and pelvis against the new SAE side impact response
corridors. In addition, the dummy was evaluated against targets for the
response of the neck in flexion and the response of the shoulder under
lateral loading.\12\
---------------------------------------------------------------------------
\11\ OSRP is an organization of the ``United States Council for
Automotive Research (USCAR),'' which is a collaborative technology
organization of Chrysler Group LLC, Ford Motor Company and General
Motors Company.
\12\ The fore-aft neck targets had previously served as design
targets for the Q-series (Irwin, AL and Mertz, HJ (1997),
``Biomechanical Basis for the CRABI and Hybrid III Child Dummies,''
Stapp Car Crash Journal V41: 1-12, SAE International, Warrendale,
PA), while the shoulder targets were newly developed (Bolte, JH et
al., (2003), ``Shoulder impact response and injury due to lateral
and oblique loading,'' Stapp Car Crash Journal, V47, SAE
International, Warrendale, PA). NHTSA's test results were reported
in: Rhule, R (2008), Side impact child dummy development, 2008 SAE
Government/Industry Meeting, Washington DC, May 2008. Download at:
https://www.nhtsa.gov/Research/Public+Meetings/SAE+2008+Government+Industry+Meeting (last accessed March 25, 2013).
OSRP results were reported in ISO committee meetings.
---------------------------------------------------------------------------
As a result of the OSRP/TC and NHTSA evaluations of Build Level C
units, three key deficiencies emerged: (1) The neck did not provide
biofidelic responses in the lateral bending mode; (2) the upper femur
ball could dislodge from the hip socket during sled tests; and (3) the
thorax exhibited cracks near the spine box following typical lateral
impacts.
c. Build Level D
Over the next several years, FTSS (hereinafter ``Humanetics'')
improved the performance of the Q3s as a result of the findings of
OSRP/TC and NHTSA.
Neck and Femur and Hip Redesigns
Although Humanetics had incorporated a redesign of the neck into
Build Level C, the OSRP/TC and NHTSA tests indicated that the neck was
in need of further work. Previously, NHTSA had designed a head and neck
retrofit for side impact applications for the Hybrid III 3-year-old
child dummy (HIII-3C). Tests of this redesigned neck showed that it
provided a more biofidelic response in lateral flexion, and better
limited the amount of axial twist than the neck of the Q3s Build Level
C.\13\ The NHTSA-developed neck specifications \14\ were applied by
Humanetics to the Q3s, and the new neck was incorporated into the Q3s
in 2009, with subsequent revisions by NHTSA to the neck center cable in
2012.
---------------------------------------------------------------------------
\13\ Test results were reported in: Wang, ZJ (2009), Q3s
improvement and Q6s development, 2009 SAE Government/Industry
Meeting, Washington DC, Feb. 2009. Download at: https://www.sae.org/events/gim/presentations/2009/jerrywang.pdf (last accessed March 25,
2013).
\14\ NHTSA's retrofit package included highly detailed
specifications, including engineering drawings for fabrication of
the neck component and response specifications for its dynamic
performance.
---------------------------------------------------------------------------
NHTSA also contributed to the redesign of the femur and hip and
several other minor parts of the dummy. The revisions were undertaken
to resolve the problem of the upper femur ball becoming dislodged from
the pelvis hip cup. This was accomplished by replacing the femur ball
and plastic hip cup with hardened aluminum components. The new pelvis
design was incorporated into the Q3s in 2009.
Thorax Material Selection
The thorax of the Q3s is a one-piece plastic casting. The cracks
near the spine box have been addressed by a change to a new castable
polyurethane resin material known by its trade name, Adiprene.
To assess the durability of the Q3s, NHTSA had established thorax
durability criteria consisting of 100 lateral impacts conducted using
the qualification test parameters (3.8 kg (8.4 lb) impactor at 3.3
meters per second (m/s)) and ten additional high-severity impacts at
4.2 m/s. In 2011, Humanetics incorporated Adiprene into the production
level Q3s. Test dummies with the new thorax material were able to meet
the agency's thorax durability criteria.
Built Level D Retrofit
The above revisions have been incorporated in a production version
of the Q3s dummy that is commercially available from Humanetics.
Humanetics' latest version of the Q3s, Build Level D, was released in
December 2010 and updated in 2011 with the Adiprene thorax, and again
in 2012 with a revision to the neck center cable. The latest revisions
have been retrofitted to the four Q3s units owned by NHTSA. In the
agency's subsequent tests--including CRS sled testing and
qualification-style impact testing--the revised neck was demonstrated
to meet NHTSA's performance criteria, and the revised pelvis and thorax
have shown no signs of failure and no degradation of performance.\15\
---------------------------------------------------------------------------
\15\ NHTSA has prepared and docketed a technical report,
``Evaluation of the Q3s Three Year Old Child Side Impact Dummy:
Repeatability, Reproducibility, and Durability (2012),'' which
includes a section that demonstrates the durability of the Q3s.
---------------------------------------------------------------------------
III. Description
The Q3s weighs 14.5 kg (32.0 lb). The 539 millimeter (mm) seated
height of the dummy is representative of a 50th percentile 3-year-old
child. The cost of an uninstrumented Q3s unit is about $48,750. The
cost of a minimum set of instruments needed for qualification and
compliance testing adds approximately $18,200, for a total cost of
about $66,950.
a. General Construction
With the exception of fasteners, instrument mounting plates, and
stiffeners for the femurs, the Q3s is almost completely devoid of
steel. The Q3s has about half the number of parts as the HIII-3C, which
eases its assembly and disassembly compared to the Hybrid III child
dummies. The main parts of the dummy are described below.\16\
---------------------------------------------------------------------------
\16\ The Q3s leg femur bone is constructed of polyurethane
molded around a steel rod that reinforces the bone. The lower leg
bone is made of polyurethane. Both the upper and lower leg bones are
surrounded by moldings that simulate flesh. The feet have no bone
structure or articulation. The Q3s's arms are a combination of
plastics and metal. The elbow joint can be adjusted and set in a
selected position. Vinyl/foam coverings surround the bones and hands
are part of the lower arm covering.
---------------------------------------------------------------------------
Head
The Q3s head is a fiberglass mold and consists of the skull and a
removable rear skull cap. Both parts are covered with a softer plastic
material that simulates flesh and provides a biofidelic response to
impact. The Q3s has a featureless face. The flesh is bonded directly to
the skull and skull cap to ensure a proper fit and cannot be separated.
The head cavity is large enough to allow use of several instruments,
including linear accelerometers and angular velocity sensors.
Thorax
The thorax of the Q3s consists of a one-piece solid ribcage molded
of polyurethane with a thin layer of polyvinyl chloride (PVC) ``skin''
bonded to the outer aspect. The ribcage is bolted to an aluminum spine.
The molded part is contoured to take the shape of a human. The variable
thickness of the part is purposefully designed so that, together with a
properly selected polyurethane density, the thorax provides a
biofidelic response to impact loading. An internally mounted IR-TRACC
\17\ measures the deflection of the
[[Page 69947]]
lateral aspect of the ribcage relative to the spine. A neoprene suit
fits over the torso, similar to a wetsuit.
---------------------------------------------------------------------------
\17\ The Infra Red Telescoping Rod for Assessment of Chest
Compression (IR-TRACC) was developed by General Motors, and first
presented in: Rouhana SW., Elhagediab AM, Chapp JJ (1998), ``A high-
speed sensor for measuring chest deflection in crash test dummies,''
Proceedings of the 16th International Technical Conference on the
Enhanced Safety of Vehicles, Windsor, Ontario, Canada, May 31-June
4, 1998, Paper Number 98-S9-O-15, 1998.
---------------------------------------------------------------------------
Neck
The Q3s neck is a segmented design that consists of a column of
three natural rubber segments bonded to four aluminum disks. A six-axis
upper neck load cell is mounted at the neck/head interface. The rubber
segments have an oval-like shape with circumferential V-shaped grooves.
A safety cable made from wire rope runs through the center of the neck
and provides axial resistance.
Shoulder
The Q3s shoulder design is molded from natural rubber into a
hollowed, rectangular structure that allows controlled buckling when
the shoulder is struck on the lateral aspect. The shoulder joint itself
consists of a ball and socket in order to simulate the humerus-scapula
joint. The upper arm has urethane flesh covering the entire outer
surface of the arm which helps reduce the inertial peak from a pendulum
impact. A string potentiometer is built into the shoulder assembly to
measure the lateral deflection of the shoulder socket joint relative to
the spine.
Spine
A short interface block connects the lower neck to the upper
thoracic spine. The thoracic spine itself is a rectangular column
machined from aluminum and about 140 mm long. It interfaces with a
rubber cylindrical prism in the upper lumbar region. A short block
connects the rubber lumbar column to the pelvis assembly.
Abdomen
The abdomen is similar to other ATDs in that it consists of a
molded, foam-filled shell with a PVC outer skin. This shell is
uninstrumented and fits between the ribcage and the pelvis.
Pelvis
The pelvis has two parts: A pelvic bone casting made of a zinc
alloy encased snuggly within a molded polyurethane flesh. The pelvis
casting is configured to accept an accelerometer array and a pubic
subassembly accommodating a pubic load cell. The hip cups and femur
heads are hardened aluminum.
Reversibility
The Q3s design incorporates reversibility features to accommodate
the dummy's use for both left and right side impacts. In NHTSA's
proposed upgrade to FMVSS No. 213, the Q3s could be used to test
forward-facing and rear-facing CRSs. The sled system proposed for use
by NHTSA would position the dummy for a left side impact when testing
forward-facing CRSs, and for a right side impact when testing rear-
facing CRSs. The PADI manual describes the steps to convert the
instrumentation from a left to a right side impact.
b. Instrumentation
Table 1 contains a list of instrumentation needed to qualify the
Q3s, i.e., the instrumentation needed for the dummy to meet the
qualification requirements included in the proposed subpart W. Note
that the FMVSS No. 213 side impact test that NHTSA is considering
focuses on measuring head acceleration, using the three uni-axial
accelerometers at the head center of gravity (C.G.), and chest
deflection, using the IR-TRACC in the thorax. Nonetheless, the other
instrumentation listed in the table would be needed for the
qualification test to assess the performance of significant parts of
the dummy and to ensure the soundness of the dummy as a whole. The Q3s
accepts additional instrumentation other than that listed below, such
as angular rate sensors in the dummy's head.
Table 1--Required Instrumentation To Qualify the Q3s Dummy Under Part 572
----------------------------------------------------------------------------------------------------------------
Location Measurement Instrument
----------------------------------------------------------------------------------------------------------------
Q3s head C.G......................... Acceleration............ Accelerometer (3 req.).
Q3s upper neck....................... Forces and moments...... Load cell.
Q3s thorax........................... Deflection.............. IR-TRACC.
Q3s shoulder......................... Deflection.............. String potentiometer.
Q3s lumbar spine..................... Forces and moments...... Load cell.
Q3s pubic symphysis.................. Force................... Load cell.
Qualification test equipment......... Neck, lumbar rotation... Angular rate sensor (2 req.).
----------------------------------------------------------------------------------------------------------------
IV. Biofidelity
a. Anthropometry
The anthropometry and dummy segment mass properties of the Q3s were
defined in the early design stage of the original Q3 based on TNO's
data in its Child Anthropometric Database (CANDAT).\18\ For the most
part, the same anthropometry and mass distributions have been retained
all the way through to the Build Level D production version of the Q3s.
The Q3s represents a 50th percentile three-year-old child, based on the
data derived from CANDAT.
---------------------------------------------------------------------------
\18\ According to TNO publications (Beusenberg et al., 1993; Van
Ratingen, et al., 1997), CANDAT is built upon various anthropometry
surveys conducted in the United States, the Netherlands, Germany,
and Japan from 1970-1993 of external dimensions and overall mass of
children from birth up to 18 years old. Each survey source examined
a different age group, and each had its own set of unique collection
parameters. To handle gaps and inconsistencies within the source
data, TNO applied regression routines and interpolation techniques
to derive the anthropometry of a particular body segment size as a
function of age or total body mass. Regression was based on the
assumption that growth is a smooth and continuous process. The
anthropometry surveys identified by TNO as the basis of CANDAT were
performed by organizations other than TNO. CANDAT is the property of
TNO and Humanetics.
---------------------------------------------------------------------------
Biofidelity targets for a particular dummy are a function of its
anthropometry and mass. Our assessment of the Q3s made use of
biofidelity targets derived by SAE. These response targets were derived
specifically for side impact dummies that have the same characteristic
dimensions and masses as the Hybrid III family of dummies. Unlike the
TNO studies used for the Q3s, the anthropometric basis of the Hybrid
III three-year-old child dummy was derived by SAE using survey data of
children in the United States only (Irwin and Mertz, 1997).\19\ SAE
also used slightly different assumptions to specify the body segment
mass properties. Nonetheless, the SAE specifications for the
anthropometry and mass of a three-year-old are very similar to those
based on CANDAT. The Q3s generally matches up with SAE specifications
as well as it does with CANDAT specifications.
---------------------------------------------------------------------------
\19\ Irwin and Mertz (1997). Biomechanical Basis for the CRABI
and Hybrid III Child Dummies. Stapp Car Crash Journal V41: 1-12, SAE
International, Warrendale, PA.
---------------------------------------------------------------------------
[[Page 69948]]
There are small differences in body segment mass properties between
the two ATDs due to differences in the manner in which TNO and SAE
apportioned the segments. For instance, the TNO torso does not include
parts of the thighs, whereas the SAE target does (the HIII-3C's thighs
are included in a sitting form pelvis consistent with other Hybrid III
dummies, which are built with a one-piece vinyl covering that fits
around the pelvis and extends mid-thigh). Since the Q3s is not
constructed in this way, its torso mass is lower than the SAE target
because it includes only the torso, not part of the thighs. Conversely,
the Q3s thigh mass is higher than the SAE target, since it includes
more of the thigh segment.
The total body mass of the Q3s matches that of the HIII-3C, and is
very close to the most recent Centers for Disease Control (CDC) growth
charts.\20\
---------------------------------------------------------------------------
\20\ CDC growth charts for year 2000 are reported by Kuczmarski
RJ, et al. (2002), 2000 CDC growth charts for the United States:
Methods and development. National Center for Health Statistics.Vital
Health Stat 11(246), 2002.
---------------------------------------------------------------------------
Table 2, below, provides the anthropometry and mass of various body
segments for the Q3s along with the reference specifications of both
CANDAT (TNO) and SAE. For reference, CDC data for height and total mass
are footnoted in the table. (Note that, unlike the erect posture of CDC
subjects, the reference posture of the Q3s is reclined and the pelvis
angle reflects a child's seating position in a CRS. Also, the neck of
the Q3s is angled such that the head is leveled when the dummy is
seated. Thus, the Q3s height measurement is an approximation only
because the dummy cannot be positioned in the same fully erect posture
taken by children when their height is measured.)
The TNO and SAE specifications for anthropometry appear essentially
the same. The anthropometry of the Q3s is also close to these
specifications, with the exception of the chest depth and the waist
circumference (both larger in the Q3s). As compared to a human, the Q3s
torso is more rounded in order to provide greater internal space for
the installation of the IR-TRACC. When struck laterally, the rounded
torso also helps to give the dummy a biofidelic response in terms of
the force needed to achieve proper chest deflection. For the waist, the
difference reflects the seated reference posture of the Q3s as compared
to the standing posture of children represented in CANDAT.
When comparing mass, Table 2 shows that the Q3s head is close to
the TNO target, but it is light in comparison to the SAE target. For
the neck, the Q3s also is aligned with the TNO target, but is light in
comparison to the SAE. As discussed in the section below, these
differences in anthropometry specifications are not significant in
terms of the biofidelity of the Q3s under impact loading.
The other body segment masses shown in Table 2 (in italics) do not
reflect a one-to-one comparison because of differences in apportioning.
We note also that the mass of the upper extremities is lighter than the
SAE value to compensate for the cumulative excess mass of the other
dummy segments, to enable the total mass of the Q3s to be on target.
Table 2--Q3s Anthropometry and Mass Compared to TNO and SAE Targets
----------------------------------------------------------------------------------------------------------------
% Difference,
ANTHROPOMETRY (mm) TNO SAE Q3s Q3s vs. SAE
----------------------------------------------------------------------------------------------------------------
Standing height*................................ 954 953 986 +3
Sitting height.................................. 551 546 556 +2
Shoulder height, sitting........................ 340 334 340 +2
Shoulder breadth (max).......................... 246 246 247 0
Hip breadth (seated)............................ 194 193 202 +5
Head depth...................................... 177 177 180 +2
Head breadth.................................... 134 135 138 +2
Head circumference.............................. 500 498 502 +1
Chest breadth................................... 161 173 174 +1
Chest depth..................................... 122 122 151 +24
Chest circumference, axilla..................... 508 505 523 +4
Waist circumference............................. 475 480 521 +9
Thigh height, sitting........................... 78 84 86 +2
Buttock-knee length............................. 293 284 305 +7
Shoulder-elbow distance......................... 190 193 186 -4
Elbow to tip of finger.......................... 250 254 240 -6
----------------------------------------------------------------------------------------------------------------
MASS (kg)
----------------------------------------------------------------------------------------------------------------
Total mass**.................................... 14.5 14.5 14.26 -2
----------------------------------------------------------------------------------------------------------------
Head............................................ 2.90 3.05 2.81 -8
Neck............................................ 0.30 0.40 0.31 -23
Torso assembly.................................. 6.20 6.61 5.78 -13
Upper extremities............................... 3.50 1.82 1.41 -22
Lower extremities............................... 1.50 2.63 3.55 +35
----------------------------------------------------------------------------------------------------------------
* Comparable reference: CDC 2000, 50th percentile three-year-old, standing fully erect:
boys: height=950 mm; total mass=14.3 kg
girls: height=940 mm; total mass=13.8 kg
**Total mass of Q3s includes its body suit, 0.40 kg.
[[Page 69949]]
b. Biofidelity Assessment Under Dynamic Loading
Our assessment of the Q3s is based primarily on biofidelity targets
established by SAE \21\ for the head, neck, shoulder, thorax, and
pelvis of a three-year-old. (A biofidelity target is the desired
performance that a dummy should attain to be considered replicating the
biomechanical response of a human.) In addition, we assessed the Q3s
against additional shoulder targets based on tests carried out at Ohio
State University (Bolte, 2003),\22\ and against abdominal targets
formulated by TNO.\23\ For the most part, the biofidelity targets are
based on pendulum impacts to body segments using cylindrical test
probes suspended by wire.
---------------------------------------------------------------------------
\21\ NHTSA has evaluated the SAE targets and is satisfied with
the technical bases underlying them. The SAE targets were derived
systematically using a defined process. The scaling theories as well
as the underlying anthropometric and biomechanical test data have
all been vetted and released to the public domain. SAE methods have
been used by NHTSA to assess the biofidelity of the majority of Part
572 ATDs and we find them to be sound, data-driven, and well-founded
scientifically.
\22\ The test procedure and biofidelity targets are described
in: Bolte JH, Hines NH, Herriot RG, Donnelly BR, McFadden JD (2003).
Shoulder impact response and injury due to lateral and oblique
loading, Stapp Car Crash Journal, V47, SAE International,
Warrendale, PA.
\23\ We have used this TNO biofidelity target because there is
none for the Q3s abdomen developed by the SAE. We have not used the
TNO biofidelity targets for the head, neck, shoulder, thorax, and
pelvis because they are derived from assumptions and underlying data
within CANDAT, some of which have not been made fully accessible to
the public. Thus, due to the transparency and reliability of the SAE
targets and because the TNO targets cannot be fully judged to the
same degree that SAE targets can be, we have decided to use
primarily the SAE targets in assessing the biofidelity of the Q3s.
---------------------------------------------------------------------------
Scaling of Adult Human Response Data
Biofidelity targets are based on observed human responses to impact
loading. Generally, to assess a dummy's biofidelity, the human's
response characteristics must be known. To assess adult dummies, adult
post mortem human subjects (PMHS) are exposed to controlled forces,
loads, and impacts and their responses are measured. However,
biomechanical response data on children under impact loading is
nonexistent or very limited, so other means must be used to estimate
the human child's response characteristics.
Scaling adult PMHS data to the child's size using mass,
anthropometry, and stiffness ratios represents the best available
method of estimating the human child's response characteristics (see
Irwin and Mertz, 1997 and Irwin, 2002, for details on the scaling
theory and assumptions applied by SAE). Thus, scaling techniques were
used to derive a set of biomechanical targets for the Q3s whereby adult
PMHS data were scaled to a three-year-old child. The targets were
determined by scaling the biomechanical responses observed for various
body segments of the midsize adult male down to a three-year-old.
Given the lack of pediatric biomechanical data and the many
assumptions made in the scaling process, there is greater uncertainty
associated with child biofidelity targets compared to the adult targets
from which they were derived. Therefore, NHTSA does not consider the
biofidelity targets applied herein to be strict prerequisites to accept
the dummy. Although biofidelity targets are central to evaluating the
dummy, we have had to carefully analyze the findings to assess the
biofidelity of the child ATD, judging, among other factors, the extent
to which the child ATD met or missed the scaled target, and whether
this would affect the usefulness of the ATD in its intended
application.
Q3s Biofidelity Assessment
The agency has prepared a supporting document, ``Biofidelity
Assessment of the Q3s Three-Year-Old Child Side Impact Dummy (July
2012),'' which provides a detailed discussion of the agency's
biofidelity assessment, which is summarized below. A copy of the report
has been placed in the docket for this NPRM. The report discusses the
performance of the Q3s relative to the biofidelity targets.
A body part-by-body part synopsis of the biofidelity performance of
the Q3s under dynamic loading is given below. For pendulum impacts,
biofidelity is generally assessed as ``external'' or ``internal.''
External biofidelity is related to the force generated on the face of a
pendulum impact probe upon striking a subject. In other words, probe
forces generated by dummies are compared against probe forces generated
by PMHS. Internal biofidelity is related to a measurement on or within
the subject itself, such as shoulder deflection or spine acceleration,
for which corresponding measurements are made on both the PMHS and the
dummy.
Head
Given that the use of the Q3s in the FMVSS No. 213 side impact test
under consideration would be to measure risk of head injury (using a
linear acceleration-based head injury criterion, HIC), we consider head
biofidelity to be highly important for the ATD. For the Q3s, we
assessed head biofidelity in both frontal (Irwin and Mertz, 1997) and
lateral (Irwin, 2002) orientations using Part 572-style head drop
procedures. The responses of the Q3s head are well within the SAE
corridors for both frontal and lateral drops, i.e., the responses
wholly met the biofidelity target for the head.
Neck
The behavior of the neck in lateral flexion affects the overall
motion of the head. We tested the Q3s neck to lateral flexion according
to the SAE protocol (Irwin, et al., 2002), which uses a standard Part
572 neck pendulum to observe the moment-angle relationship. The Q3s
neck response is entirely within the SAE corridors, completely meeting
the biofidelity target.
We also assessed the biofidelity of the Q3s neck in frontal flexion
(Irwin and Mertz, 1997). In the frontal flexion assessment, we found
that the Q3s neck data generally follows the shape of the corridor of
the biofidelity target, although the curve is not completely contained
within the corridor. Given that neck flexion occurs mainly in the
lateral direction under the intended use of the dummy, a slight
nonconformity in frontal flexion is not disconcerting. On balance, we
find the biofidelity of the Q3s neck to be satisfactory for use in our
CRS side impact safety standard under consideration.
Shoulder
Although there is no shoulder IARV being contemplated for the Q3s,
the shoulder does interact with the CRS during the test procedure under
consideration for FMVSS No. 213. In view of this, NHTSA evaluated the
biofidelity of the Q3s shoulder in component testing under the loading
of a pendulum.
The unpadded test involved the SAE protocol (Irwin, 2002), which
uses a rigid pendulum in a pure lateral direction. Response criteria
included corridors for lateral shoulder displacement and for probe
force. The Q3s shoulder showed high stiffness with respect to lateral
shoulder displacement and probe force under this test protocol.
Next we reexamined shoulder biofidelity under conditions that
correspond more closely to the intended use of the Q3s in the FMVSS No.
213 test procedure being contemplated: Those of the Ohio State protocol
(Bolte et al., 2003), which uses the same impactor mass and speed as
the SAE test but with foam padding attached to the impactor face. The
latter condition was considered because the FMVSS No. 213 impact being
contemplated exposes the Q3s to the padded side structure
[[Page 69950]]
(``wing'') of the child restraint in the test.
Under the Ohio State protocol, test results also indicate that the
shoulder of the Q3s is stiff when assessed for biofidelity as measured
by its internal deflection. However, the force response of the padded
probe (external biofidelity) nearly matches the target. As such, the
Q3s shoulder appears to be biofidelic in the manner in which it would
exert force on the child restraint system. This loading of the child
restraint, which would affect the overall motion of the dummy's upper
torso and head (through which the FMVSS No. 213 injury criteria under
consideration would be measured), appears representative of an actual
human.
Thorax
The biofidelity of the thorax under lateral loading is an important
performance target for the Q3s since the agency is considering a
proposal to adopt thorax deflection as an injury assessment reference
value (IARV) in the FMVSS No. 213 side impact test. Thorax biofidelity
is assessed via high (6.0 m/s) and low (4.3 m/s) speed pendulum impacts
prescribed by SAE. Pendulum force corridors are used to assess the
external biofidelity of the dummy, and upper torso (T1) acceleration is
used to assess internal biofidelity. (SAE did not develop a biofidelity
target based on thorax deflection because PMHS in the underlying tests
were not instrumented as such.)
Test results indicate that the pendulum forces generated by the Q3s
are within the corridors for both high and low speed tests. The
magnitude of the internal T1 acceleration is also on target, though it
is slightly out of phase with the biofidelity corridor (i.e., the peak
magnitude is within the limit afforded by the corridor, but it occurs
about 10 ms too early). We believe this phase difference, which is
related to the mechanics of human thoracic tissues vs. the Q3s polymer
thorax, is an acceptable compromise in producing a dummy that is
affordable, durable, and otherwise practicable for use as a regulatory
tool.
Abdomen
We assessed the biofidelity of the abdomen in an oblique pendulum
impact using probe force targets established by TNO. This assessment
was carried out with the probe striking the antero-lateral aspect of
the dummy rather than the full lateral aspect because neither TNO nor
SAE had established biofidelity targets for the latter. Furthermore,
abdominal biofidelity is important mostly in frontal impacts in
relation to lap belt loading. Since the Q3s would primarily be used in
side impacts to test CRSs having an internal harness, abdominal loads
are not expected to be excessive. Nonetheless, the loading to the
abdomen in the FMVSS No. 213 testing under consideration may have some
frontal component, with the resultant loading being oblique. Therefore,
the biofidelity assessment was performed with an oblique impact. The
Q3s performed very favorably when examined against the TNO established
targets.\24\
---------------------------------------------------------------------------
\24\ The TNO targets are based on a scaling of adult PMHS data
in which subjects were struck in the abdomen by a pendulum aligned
30 degrees from lateral (i.e., an oblique impact). The PMHS data is
from a test series where subjects initially underwent thoracic
impacts and then were re-used for abdominal impacts. The thoracic
impact data were used to establish thorax corridors in the ISO 9790
Technical Report, the underlying source document upon which the SAE
three-year-old targets have been derived. The repeat abdominal
tests, however, were not used by ISO and thus no SAE targets are
provided for abdominal biofidelity subjected to pendulum impacts.
---------------------------------------------------------------------------
Moreover, noting that an assumption was made by TNO that the child
abdomen is stiffer than the adult, NHTSA re-formulated the corridor by
assuming that abdomen stiffness is a function of the elastic modulus of
soft tissue, and that child and adult moduli are the same. (This
assumption was also employed in developing the SAE corridors for other
body regions.) When compared against the re-formulated corridor, the
Q3s performs a little less favorably, but still follows along the upper
bound of the corridor. Details of this comparison are provided in our
supporting document, ``Biofidelity Assessment of the Q3s Three-Year-Old
Child Side Impact Dummy,'' supra at p. 17.
Pelvis
The external biofidelity of the pelvis was assessed using an SAE
pendulum impact protocol (lateral impact of 2.27 kg rigid impact probe
at 4.5 m/s) and pendulum force limits. The test results indicate that
the Q3s pelvis appears stiff relative to a child. The dummy had been
redesigned with hardened aluminum hips replacing plastic ones to
improve its durability, and this change may have resulted in a greater
force response. Nonetheless, in our repeatability and reproducibility
testing with Cozy Cline CRSs (discussed later), the wide scatter in
pelvis response did not seem to have any effect on HIC15 and chest
deflection. Further, the tradeoff in biofidelity for improved
durability may be necessary for use of the dummy in a regulatory
environment.
Summary
Our biofidelity assessment of the Q3s is based on head drops and
pendulum tests, which have demonstrated the biofidelity of the test
dummy. Our test results indicate that the biofidelity of the Q3s is
most satisfactory for the head, thorax, and neck. It is in these three
body segments where proper biofidelity is most critical for the
intended use of the dummy in the FMVSS No. 213 test procedure under
consideration.
Relative to humans, the dummy appears to be stiff in the shoulder
and pelvis. For a CRS under test, the shoulder and pelvis could
conceivably act as load paths such that the thorax deflection in the
Q3s may be unrealistically low relative to a human. However, it may not
be feasible to engineer a biofidelic design into the shoulder and
pelvis at this time without sacrificing some other critical performance
features, such as durability. While a child test dummy with a more
biofidelic shoulder and pelvis may be developed in the future, the
agency tentatively concludes that the Q3s is a suitable and valuable
test device for use in child restraint side impact testing at this
time. On balance, the agency is satisfied with the overall biofidelity
of the Q3s.
V. Repeatability and Reproducibility
A test dummy's repeatability and reproducibility (R&R) is
demonstrated in sled tests and component tests. Sled tests establish
the consistency of the dummy's kinematics, its impact response as an
assembly, and the integrity of the dummy's structure and
instrumentation under controlled and representative crash environment
test conditions. In component tests, the impact input as well as the
test equipment is carefully controlled to minimize external effects on
the dummy's responses. NHTSA has assessed the repeatability and
reproducibility of the Q3s in CRS side impact sled tests and in
component tests.
Repeatability is defined as the similarity of responses from a
single dummy when subjected to multiple repeats of a given test
condition. Reproducibility is defined as the similarity of test
responses from multiple dummies when subjected to multiple repeats of a
given test condition. A quantitative assessment of R&R is achieved
using a statistical analysis of variance. The percent coefficient of
variation (%CV) is a measure of variability expressed as a percentage
of the mean. The %CV is calculated as follows:
[[Page 69951]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.000
Where [sigma] = standard deviation of responses \25\
\25\ Standard deviations are based on a sample and calculated
using the ``n-1'' method.
---------------------------------------------------------------------------
X = mean of responses
We have used a %CV scale shown in Table 3 to assess the quality of
repeatability and reproducibility of the Q3s. This approach was first
introduced by NHTSA as a means of evaluating dummy repeatability when
the original subpart B Hybrid II 50th percentile male ATD was proposed
(40 FR 33466, August 8, 1975). Since then, the agency has used this
approach for other 49 CFR Part 572 rulemakings, including those to
adopt side impact dummies such as the ES-2re midsize adult male side
impact dummy (subpart U, 71 FR 75304, December 14, 2006) and the SID-
IIs 5th percentile adult female side impact dummy (subpart V, 71 FR
75342, December 14, 2006).
Table 3--%CV Score Categorization for Repeatability and Reproducibility
------------------------------------------------------------------------
Reproducibility %
Repeatability % CV Score CV Score Assessment
------------------------------------------------------------------------
%CV <= 5...................... %CV <= 6......... EXCELLENT.
5 < %CV <= 8.................. 6 < %CV <= 11.... GOOD.
8 < %CV <= 10................. 11 < %CV <= 15... MARGINAL.
%CV > 10...................... %CV > 15......... POOR.
------------------------------------------------------------------------
For repeatability and reproducibility assessments, acceptable
limits are ``MARGINAL'' and above. For repeatability, the MARGINAL
limit is set at a %CV value of 10 percent. For MARGINAL
reproducibility, a slightly greater %CV of 15 percent is used since
multiple dummies produce a wider dispersion of response measurement
than in testing a single dummy for repeatability. These limits were
most recently used in adopting the HIII-10C 10-year-old child dummy
into 49 CFR Part 572 (subpart T, 77 FR 11651, February 27, 2012). All
R&R values in the ``POOR'' category were investigated to assess the
cause of the high variance. If needed, corrective measures were made to
the dummy.
a. R&R in Sled Tests
In the sled tests, a CRS was mounted on a generic bench seat which
was allowed to slide into a padded wall, generating lateral impact
loading on the CRS and the Q3s dummy. The deceleration pulse of the
sliding bench seat was controlled by the crush of aluminum honeycomb.
The peak lateral acceleration of the test buck was approximately 25.4 g
and the peak velocity was 31.4 km/h (19.5 mph).\26\ The configuration
and sled pulse generally corresponded to the procedure under
consideration for the FMVSS No. 213 side impact test, except the
loadwall had a uniform surface.
---------------------------------------------------------------------------
\26\ The acceleration of the test buck is intended to mimic the
impulse experienced by a CRS installed in the rear seat of a small
passenger vehicle subjected to a side impact by a moving deformable
barrier as specified in FMVSS No. 214, ``Side impact protection.''
---------------------------------------------------------------------------
To assess the R&R of the Q3s in sled tests, two dummies were each
tested five times using the sliding seat sled buck. The simulated wall
padding was replaced after each test. Two sets of seat padding for the
sliding bench were alternated after each test. The locations of
multiple dummy landmarks were measured before each test to minimize
test-to-test variation in the dummy's seated position.
All tests were performed with identical forward-facing Graco Cozy
Cline child restraints, with a new child restraint used for each test.
These child restraints were sold for children weighing 9 to 18 kg (20
to 40 lb). In CRS tests performed in support of NHTSA's proposed
rulemaking to add a side impact test to FMVSS No. 213, the Cozy Cline
child restraint produced Q3s metrics that were generally high relative
to those produced by other CRSs. Thus, we chose to evaluate the R&R of
the Q3s with the Cozy Cline child restraint because the data indicated
that these child restraints more vigorously exercised the dummy's
assessment of the injury criteria of interest compared to other CRSs we
have tested.
The sled test results indicated ``GOOD'' to ``EXCELLENT''
repeatability and reproducibility.\27\ The statistical analysis of
select measurements in all tests for each dummy and both dummies
combined is summarized in Table 4. NHTSA has prepared and docketed a
technical report, ``Evaluation of the Q3s Three Year Old Child Side
Impact Dummy: Repeatability, Reproducibility, and Durability (2012),''
which discusses the test procedures and results in greater detail. The
report also provides references for the location of the test data
including sensor signals and videography.
---------------------------------------------------------------------------
\27\ Qualification tests were performed on each dummy before and
after the sled test series to evaluate the Q3s's durability. The
dummies met all of the preliminary qualification response
requirements, both before and after the sled series.
Table 4--Summary of Sled Test Responses for Select Channels
--------------------------------------------------------------------------------------------------------------------------------------------------------
Dummy S/N 006 Dummy S/N 007 Combined Data
Used for: Parameter --------------------------------------------------------------------------------
Avg Std dev % CV Avg Std dev % CV Avg Std dev % CV
--------------------------------------------------------------------------------------------------------------------------------------------------------
FMVSS \1\................................ HIC15....................... 700 14.8 2 708 19.4 3 704 16.8 2
P572 \2\ & FMVSS \1\..................... Thorax Y-Disp, mm........... 34 0.8 2 33 2.8 9 34 2.0 6
Part 572 \2\............................. Head Res-Accel, g........... 97 2.1 2 96 2.0 2 96 2.0 2
R&D \3\.................................. Neck Y-force, N............. 744 56.5 8 687 57.3 8 716 61.4 9
Part 572 \2\............................. Neck X-Moment, Nm........... 31 3.8 12 28 2.3 8 29 3.4 12
Part 572 \2\............................. Shoulder Y-Disp, mm......... 24 1.0 4 24 0.8 3 24 0.8 4
R&D \3\.................................. Up spine Res-Accel, g....... 65 3.3 5 65 8.2 13 65 5.9 9
R&D \3\.................................. Lumbar Y-Force, N........... 324 20.7 6 343 38.8 11 333 31.0 9
R&D \3\.................................. Pelvis Res-Accel, g......... 101 15.8 16 106 22.9 22 104 18.7 18
[[Page 69952]]
Part 572 \2\............................. Pubic Y-Force, N............ 388 43.4 11 324 75.5 23 356 67.1 19
--------------------------------------------------------------------------------------------------------------------------------------------------------
\1\ CRS requirement under consideration for a FMVSS No. 213 side impact test.
\2\ Qualification for proposed Part 572.
\3\ Injury assessment for research and development (R&D) only.
The following discusses the sled test results that relate to
responses of primary importance to the dummy's use in side impact,
i.e., primarily measurements under consideration for use in the FMVSS
No. 213 side impact test, and measurements that would serve as Part 572
qualification targets. Other measurements commonly examined in research
efforts are also discussed below.
Head Acceleration and HIC15
As seen in Table 4, head acceleration and HIC15 both displayed
``EXCELLENT'' repeatability and reproducibility. Since these responses
are being considered as injury criteria for our CRS side impact
requirements, we believe it is very important for these responses to
exhibit a high degree of repeatability. It is notable that the average
HIC15 value was 704. This value exceeds the IARVs under consideration
for our CRS requirements, thus demonstrating that the dummy has very
good R&R up to and beyond the expected pass/fail limit.
Thorax Deflection
Thorax deflection (labeled ``Thorax Y-Disp'' in Table 4), as
measured by the IR-TRACC, also displayed ``EXCELLENT'' reproducibility
when the responses of both dummies were combined. The average
measurement of 34 mm exceeds the IARVs under consideration for our CRS
requirements, which attests to the reliable performance of the dummy at
pass/fail limits.
We note that for dummy serial number 007, the thorax y-displacement
is only ``MARGINAL.'' Closer inspection of the lateral thorax
displacement data indicates that the response for one of the tests was
quite different than that of the previous four tests. Our review of the
pre-test positioning data revealed that in test 5, the dummy's elbow
location relative to other body landmarks was farthest away from the
average location. We believe that the elbow position relative to the
dummy's torso played a critical role in the amount of subsequent
lateral thorax displacement. Because these data show an apparent
sensitivity to elbow positioning, the agency has developed a procedure
to position the elbow at a specific angle relative to the thorax.
Neck Y-Force and X-Moment
Neck Y-force and X-moment responses exhibited ``GOOD'' and
``MARGINAL'' reproducibility, respectively. A closer inspection of the
data indicates that the peak neck force in one of the tests for dummy
serial number 006 was about 40 percent lower than the other four tests,
for reasons that could not be determined by the test technicians. If
test 3 were removed from the dataset, the repeatability of dummy 006
for neck X-moment becomes ``EXCELLENT'' and the overall reproducibility
becomes ``GOOD.''
Shoulder Y-Displacement
The shoulder displacement, as measured by the Q3s's internal string
potentiometer, also displayed ``EXCELLENT'' repeatability in both
dummies as well as in its overall reproducibility when the responses of
both dummies are combined. Although there is no IARV associated with
shoulder displacement, the average measurement of 24 mm is fairly high
in comparison to the values obtained in research tests from other
tested CRSs. Again, this attests to the good performance of the dummy
in conditions beyond those to which the ATD will typically be exposed
in an FMVSS No. 213 compliance test.
Upper Spine Acceleration
The overall reproducibility of both dummies combined was ``GOOD,''
although the upper spine resultant acceleration for dummy 007 displayed
``POOR'' repeatability. However, as with the lateral thorax
displacement responses, the upper spine acceleration for test 5 of
dummy 007 was anomalous as compared to the previous four tests. We
believe that this result is related to the issue of arm position. We
note that if test 5 were removed from the dataset, the ``POOR''
repeatability of dummy 007 for upper spine acceleration becomes
``EXCELLENT'' and the overall reproducibility also becomes
``EXCELLENT.''
Pelvis Resultant-Acceleration, Lumbar Y-Force, and Pubic Y-Force
Poor repeatability was observed in the pelvic and lumbar responses.
Pelvis resultant acceleration response curves revealed a sharp spike in
the data around 90 ms. These spikes obscured the true data peaks, which
occurred around 85 ms, and therefore present a negative effect on the
repeatability analysis. A similar spike, of lesser magnitude, was
evident in the lumbar Y-force responses, also around the 90 ms mark of
the event.
The source of the data spikes were subsequently determined by NHTSA
to emanate from ``knee knock.'' The dummy's knees are hard plastic
components, and they contacted each other precisely at the instant that
the spikes occurred in the pelvis acceleration and lumbar Y-force
channels. This condition has since been mitigated in the final Q3s
design which incorporates a padded covering over the medial aspect of
the knees to dampen the force of impact.
The repeatability of the pubic Y-force measurement was also shown
to be ``POOR.'' This rating is not attributed to the knee knock
condition. Rather, pubic Y-force appears to be a measurement that is
highly sensitive to any variation in the test conditions. Nonetheless,
variations in pubic Y-force do not appear to affect the dummy's head
acceleration and thorax Y-displacement (the IARVs we are exploring for
the FMVSS No. 213 side impact test under consideration), which
exhibited low variability despite the scatter in pubic force.
Supplemental Tests
In consideration of the ``MARGINAL'' performance observed for some
of the responses in the previous sled test series, we ran another
series of Cozy Cline tests with the final version of the Q3s. The final
Q3s incorporated the aforementioned pads on the medial surfaces of the
knees as well as a simplified design of the neck center cable. The
older cable design was
[[Page 69953]]
thought to contribute to the non-uniformity observed in the earlier
sled tests. Additionally, we added a padded door panel and positioned
the arm at 25 degrees to be more consistent with what is under
consideration for the proposed side impact test protocol.
The results for this supplemental test series are shown in Table 5.
As compared to the previous set of tests shown in Table 4, the
supplemental series demonstrate improved repeatability in measurements
of shoulder and thorax deflection, neck loads, and pelvis acceleration.
These improvements are directly related to a new arm positioning
protocol, the revised neck center cable, and the elimination of knee
knock, respectively.
Pubic force repeatability was again rated as ``POOR.'' Since the
revisions to the dummy and test protocol were not aimed at improving
this measure, the ``POOR'' rating was not unexpected.
Table 5--Summary of Supplemental Sled Test Responses for Select Channels
----------------------------------------------------------------------------------------------------------------
Dummy S/N 004
Used for: Parameter ----------------------------------------
Avg Std dev % CV
----------------------------------------------------------------------------------------------------------------
FMVSS \1\................................ HIC15....................... 795 22.2 3
P572 \2\ & FMVSS \1\..................... Thorax Y-Disp, mm........... 17.8 0.7 4
Part 572 \2\............................. Head Res-Accel, g........... 110 3.6 3
R&D \3\.................................. Neck Y-force, N............. 630 42 7
Part 572 \2\............................. Neck X-Moment, Nm........... 28.0 1.9 7
Part 572 \2\............................. Shoulder Y-Disp, mm......... 24.3 0.5 2
R&D \3\.................................. Up spine Res-Accel, g....... 129 6.8 5
R&D \3\.................................. Lumbar Y-Force, N........... 765 69 9
R&D \3\.................................. Pelvis Res-Accel, g......... 97.1 8.5 9
Part 572 \2\............................. Pubic Y-Force, N............ 557 118 21
----------------------------------------------------------------------------------------------------------------
\1\ CRS requirement under consideration for a FMVSS No. 213 side impact test.
\2\ Qualification for proposed Part 572.
\3\ Injury assessment for research and development (R&D) only.
b. R&R in Component Qualification Tests
Test dummies specified in 49 CFR Part 572 are subjected to a series
of qualification tests to ensure that their components are functioning
properly. The qualification tests proposed for the Q3s are discussed
further in a later section. We have proposed qualification tests for
the dummy's head, neck, shoulder, thorax, lumbar, and pelvis, assessing
35 response mechanisms for the dummy.
We tested NHTSA's four Q3s units to the proposed qualification
tests, assessing among other matters the performance of the units when
tested to the qualification tests, and the repeatability and
reproducibility of the dummies. The findings are discussed in the
technical report, ``Evaluation of the Q3s Three Year-Old Child Side
Impact Dummy: Repeatability, Reproducibility, and Durability,'' supra.
R&R in the component qualification tests were assessed by testing
the four Q3s dummies, all conforming to the latest available revision
level. Tests were run for both right and left side impacts. Average,
standard deviation, and coefficient of variation were computed for each
required measurement parameter of each qualification procedure. We used
the same guidelines to rate R&R as was used previously in our R&R
evaluation using sled tests (see Table 3, supra).
Head Drop Tests
Head qualification consisted of two test components: Frontal and
lateral head drops. The frontal head drop was conducted from a height
of 376 mm, while the lateral head drop was conducted at 200 mm.
Four Q3s dummy heads were each subjected to six frontal head drops,
five left-side lateral drops, and five right-side lateral drops. The
responses are summarized in Table 6 for frontal drops and in Table 7
with left- and right-side tests combined. Each individual head was
rated as having ``EXCELLENT'' repeatability in both the frontal and
lateral modes. When combining the responses, the reproducibility of all
four heads was also rated as ``EXCELLENT'' in both the frontal and
lateral test modes.
Table 6--Summary of Frontal Head Drop Responses
------------------------------------------------------------------------
Resultant
Dummy S/N accel (g)
------------------------------------------------------------------------
004............................... avg................... 273.0
stdev................. 3.86
%CV................... 1.41
006............................... avg................... 276.5
stdev................. 2.48
%CV................... 0.90
007............................... avg................... 282.0
stdev................. 4.35
%CV................... 1.54
008............................... avg................... 263.5
stdev................. 5.12
%CV................... 1.94
All............................... avg................... 273.8
stdev................. 7.68
%CV................... 2.80
------------------------------------------------------------------------
Table 7--Summary of Lateral Head Drop Responses
------------------------------------------------------------------------
Resultant
Dummy S/N Orientation L&R accel (g)
------------------------------------------------------------------------
004............................... Avg................... 131.3
Stdev................. 3.50
%CV................... 2.67
006............................... Avg................... 124.7
Stdev................. 3.64
%CV................... 2.92
007............................... Avg................... 127.1
Stdev................. 3.92
%CV................... 3.08
008............................... avg................... 123.2
stdev................. 4.08
%CV................... 3.31
All............................... avg................... 126.6
stdev................. 4.78
%CV................... 3.78
------------------------------------------------------------------------
Neck Pendulum Tests
Flexion Tests. The two flexion tests utilized the Part 572 neck
pendulum and a headform designed to mimic the inertial properties of
the head (Part 572, Subpart E, Figure 22). The frontal flexion test was
at a 4.7 m/s impact speed and the lateral test was at a 3.8 m/s speed.
Both tests prescribed a deceleration pulse. For the frontal
[[Page 69954]]
flexion tests, four Q3s dummy necks were subjected to five tests. For
lateral flexion, each of the four necks was subjected to five left-side
tests and five right-side tests.
The responses are summarized in Table 8 (frontal flexion) and Table
9 (lateral flexion). For the frontal flexion and lateral flexion tests,
each individual neck provided ``EXCELLENT'' repeatability for all
criteria considered. Reproducibility was also ``EXCELLENT'' for all
four necks combined.
Neck Torsion. During CRS testing, the Q3s neck may flex with
varying degrees of neck twist. We have therefore developed a procedure
to assure that the neck is repeatable under twist. The new neck torsion
test uses a special test fixture attached to the Part 572 pendulum,
which imparts a pure torsion moment to the isolated neck. The test
specifies a 3.6 m/s impact speed with a defined deceleration pulse.
Each of the four Q3s dummy necks was subjected to five left-side tests
and five right-side tests. The responses are summarized in Table 10
with left- and right-side tests combined. Each individual neck provided
``EXCELLENT'' repeatability for all criteria considered.
Reproducibility was also ``EXCELLENT'' for all four necks combined.
Table 8--Summary of Frontal Flexion Neck Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Max angle Peak Y-moment
Dummy S/N ---------------------------------------------------------------- Head rotation
angle deg time ms moment N-m time ms decay time, ms
--------------------------------------------------------------------------------------------------------------------------------------------------------
004....................................... Avg......................... 77.1 58.5 47.1 54.3 52.2
stdev....................... 0.42 0.62 0.63 1.02 0.10
%CV......................... 0.55 1.06 1.35 1.88 0.20
006....................................... Avg......................... 77.5 59.3 46.0 56.1 52.2
stdev....................... 0.74 0.84 1.10 1.89 0.20
%CV......................... 0.96 1.42 2.40 3.38 0.38
007....................................... Avg......................... 74.3 58.3 46.8 55.7 51.3
stdev....................... 0.79 0.70 0.71 1.47 0.17
%CV......................... 1.07 1.20 1.51 2.64 0.34
008....................................... Avg......................... 74.8 57.9 46.9 54.2 51.2
stdev....................... 0.69 0.65 1.90 1.10 0.23
%CV......................... 0.92 1.12 4.04 2.03 0.45
All....................................... Avg......................... 76.1 58.7 46.4 55.5 51.7
stdev....................... 1.77 1.12 1.50 2.00 0.48
%CV......................... 2.33 1.90 3.23 3.61 0.93
--------------------------------------------------------------------------------------------------------------------------------------------------------
Table 9--Summary of Lateral Flexion Neck Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Max angle Peak X-moment
Dummy S/N Orientation L&R ---------------------------------------------------------------- Head rotation
angle deg time ms moment N-m time ms decay time, ms
--------------------------------------------------------------------------------------------------------------------------------------------------------
004....................................... avg......................... 83.3 68.8 28.4 69.5 66.6
stdev....................... 0.53 0.60 1.48 0.78 0.53
%CV......................... 0.63 0.87 5.23 1.13 0.79
006....................................... avg......................... 85.2 69.9 28.8 70.6 66.8
stdev....................... 0.32 0.64 0.82 0.55 0.68
%CV......................... 0.37 0.91 2.84 0.77 1.01
007....................................... avg......................... 81.0 68.0 27.7 69.4 65.5
stdev....................... 0.44 0.79 0.59 0.90 0.60
%CV......................... 0.55 1.16 2.14 1.29 0.92
008....................................... avg......................... 81.7 67.7 27.9 68.8 65.8
stdev....................... 0.73 0.56 0.71 0.70 0.87
%CV......................... 0.89 0.82 2.53 1.02 1.32
All....................................... avg......................... 82.8 68.6 28.2 69.6 66.2
stdev....................... 1.69 1.08 1.05 0.98 0.86
%CV......................... 2.04 1.57 3.72 1.41 1.30
--------------------------------------------------------------------------------------------------------------------------------------------------------
Table 10--Summary of Torsional Neck Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Max angle Peak Z-moment
Dummy S/N Orientation L&R ---------------------------------------------------------------- Head rotation
angle deg time ms moment N-m time ms decay time, ms
--------------------------------------------------------------------------------------------------------------------------------------------------------
004....................................... avg......................... 84.9 102.3 9.0 96.2 93.8
stdev....................... 0.39 0.51 0.03 0.82 0.64
%CV......................... 0.46 0.50 0.28 0.85 0.68
006....................................... avg......................... 89.7 108.4 8.3 102.1 99.0
stdev....................... 0.53 0.52 0.07 2.03 0.51
%CV......................... 0.59 0.48 0.84 1.99 0.52
007....................................... avg......................... 80.7 98.7 9.2 90.8 89.8
stdev....................... 1.22 0.60 0.31 1.39 1.05
%CV......................... 1.51 0.61 3.35 1.53 1.17
[[Page 69955]]
008....................................... avg......................... 81.3 99.3 9.0 91.9 90.9
stdev....................... 1.50 0.72 0.08 0.78 0.77
%CV......................... 1.85 0.72 0.84 0.85 0.84
All....................................... avg......................... 84.2 102.2 8.9 95.2 93.4
stdev....................... 3.71 3.89 0.37 4.64 3.62
%CV......................... 4.40 3.80 4.21 4.87 3.88
--------------------------------------------------------------------------------------------------------------------------------------------------------
Shoulder Impact
This test assures that the shoulder acts uniformly in the way it
deforms under load and distributes the load under a direct lateral
impact, thus helping to assure that whole-body kinematics of the ATD
are consistent.
Shoulder tests consisted of a lateral impact to the shoulder using
a 3.8 kg probe at an impact speed of 3.6 m/s. Each of the four Q3s
dummies was impacted five times on both their left and right shoulders.
The responses are summarized in Table 11 with left- and right-side
tests combined. The shoulder responses for each individual dummy were
rated as having ``EXCELLENT'' repeatability. The reproducibility of
shoulder responses for all four dummies combined was also rated as
``EXCELLENT.''
Table 11--Summary of Shoulder Test Responses
----------------------------------------------------------------------------------------------------------------
Shoulder
Dummy S/N Orientation L&R displacement Probe force
(mm) (N)
----------------------------------------------------------------------------------------------------------------
004........................................... Avg............................. 18.4 1281.5
Stdev........................... 0.47 27.99
%CV............................. 2.57 2.18
006........................................... Avg............................. 19.0 1270.3
Stdev........................... 0.35 12.91
%CV............................. 1.84 1.02
007........................................... Avg............................. 18.8 1295.0
Stdev........................... 0.46 13.55
%CV............................. 2.46 1.05
008........................................... Avg............................. 18.6 1280.1
Stdev........................... 0.83 10.75
%CV............................. 4.48 0.84
All........................................... Avg............................. 18.7 1281.7
Stdev........................... 0.58 19.16
%CV............................. 3.12 1.50
----------------------------------------------------------------------------------------------------------------
Thorax Impacts
The thorax qualification tests were conducted two ways: Without arm
interaction (as in the SAE test) and with the arm attached and down
such that the impact probe strikes the upper arm. Both tests utilized a
lateral impact with a 3.8 kg probe.
In the ``thorax without arm'' test, the arm was completely removed
from the dummy. The 3.8 kg test probe was aligned with the thorax
displacement IR-TRACC and impacted the thorax laterally at a speed of
3.3 m/s. Each of the agency's four dummies was impacted five times on
both the left and right sides. Table 12 below provides a summary of the
responses with left- and right-side tests combined.
Table 12--Summary of Thorax Without Arm Qualification Test Responses
----------------------------------------------------------------------------------------------------------------
Thorax
Dummy S/N Orientation L&R displacement Probe force
(mm) (N)
----------------------------------------------------------------------------------------------------------------
004........................................... avg............................. 27.3 705.2
stdev........................... 0.45 15.52
%CV............................. 1.66 2.20
006........................................... avg............................. 28.6 665.1
stdev........................... 0.77 27.83
%CV............................. 2.69 4.18
007........................................... avg............................. 28.1 692.1
stdev........................... 0.19 22.92
%CV............................. 0.67 3.31
008........................................... avg............................. 26.3 710.9
stdev........................... 0.19 19.51
%CV............................. 0.70 2.74
All........................................... avg............................. 27.6 693.3
[[Page 69956]]
stdev........................... 1.00 27.63
%CV............................. 3.63 3.99
----------------------------------------------------------------------------------------------------------------
For the ``arm attached'' test, the upper arm was positioned
vertically and aligned with the dummy's thorax. The lower arm was
positioned to make a 90 degree angle with the upper arm. The impact
speed of the probe was 5.0 m/s.
Each of the four test dummies was impacted five times on both the
left and right sides. Table 13 provides a summary of the test results
with left- and right-side tests combined.
Table 13--Summary of Thorax With Arm Attached Qualification Test Responses
----------------------------------------------------------------------------------------------------------------
Thorax Peak probe
Dummy S/N Orientation L&R displacement force after 5
(mm) ms (N)
----------------------------------------------------------------------------------------------------------------
004........................................... avg............................. 26.0 1527.5
stdev........................... 0.63 28.58
%CV............................. 2.41 1.87
006........................................... avg............................. 26.3 1567.1
stdev........................... 0.55 46.47
%CV............................. 2.09 2.97
007........................................... avg............................. 25.9 1512.7
stdev........................... 0.37 60.32
%CV............................. 1.44 3.99
008........................................... avg............................. 25.2 1542.3
stdev........................... 0.48 45.96
%CV............................. 1.92 2.98
All........................................... avg............................. 25.9 1537.4
stdev........................... 0.64 49.28
%CV............................. 2.46 3.21
----------------------------------------------------------------------------------------------------------------
For thorax impacts both with and without the arm, each dummy was
rated as having ``EXCELLENT'' repeatability. Furthermore, the responses
of all four dummies combined produced a rating of ``EXCELLENT''
reproducibility.
Note that the peak probe force was taken after 5 ms to separate the
probe's initial inertial response during arm contact from the probe's
response due to its interaction with the thorax. The typical probe
force response curve exhibited dual peaks of nearly equal magnitude,
with the first peak occurring upon initial impact of the probe with the
arm and the second peak occurring as the arm loaded the thorax (see
Figure 1 below). Analysis of the response curves indicated that the
first peak typically occurred before 5 ms, and the second peak occurred
after 5 ms. Because the second peak is more closely related to the
resistive force of the thorax, we concluded that the first peak was not
determinative.
[[Page 69957]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.001
Lumbar Pendulum Tests
Lumbar testing consisted of two types of pendulum tests: A frontal
test and a lateral test. For both tests, the lumbar spine element
containing the flexible column was removed from the dummy similar to
the neck qualification tests. Lumbar tests were conducted using the
same Part 572 neck pendulum and the headform device utilized in the
neck qualification tests. Frontal and lateral tests were conducted at
an impact speed of 4.4 m/s.
Five frontal tests were carried out on lumbar elements from each of
the four test dummies. For the lateral tests, five were conducted on
the left side and five on the right side. The results are summarized in
Table 14 (frontal) and Table 15 (lateral) with left- and right-side
tests combined. The repeatability of each lumbar element was rated as
either ``EXCELLENT'' or ``GOOD'' for all test measurements. The
reproducibility of responses of all four lumbar elements combined was
``EXCELLENT'' for all measurements.
Table 14--Summary of Frontal Lumbar Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Max angle Peak Y-moment
Dummy S/N ---------------------------------------------------------------- Head rotation
angle deg time ms moment N-m time ms decay time, ms
--------------------------------------------------------------------------------------------------------------------------------------------------------
004....................................... avg......................... 52.8 55.1 84.2 51.2 53.8
stdev....................... 1.05 0.89 1.46 3.75 0.34
%CV......................... 1.99 1.61 1.74 7.31 0.63
006....................................... avg......................... 52.5 54.8 87.1 51.4 52.7
stdev....................... 1.79 0.81 0.85 2.81 0.61
%CV......................... 3.40 1.48 0.97 5.48 1.15
007....................................... avg......................... 53.4 56.1 84.2 51.4 53.9
stdev....................... 1.41 0.89 1.38 3.02 0.68
%CV......................... 2.65 1.58 1.64 5.88 1.26
008....................................... avg......................... 51.4 54.4 88.5 50.8 52.3
stdev....................... 1.13 0.71 2.21 2.06 0.27
%CV......................... 2.19 1.31 2.49 4.06 0.52
All....................................... avg......................... 52.5 55.1 86.0 51.2 53.2
stdev....................... 1.47 0.99 2.39 2.74 0.85
%CV......................... 2.79 1.79 2.78 5.35 1.60
--------------------------------------------------------------------------------------------------------------------------------------------------------
[[Page 69958]]
Table 15--Summary of Lateral Lumbar Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Max angle Peak X-moment
Dummy S/N Orientation L&R ---------------------------------------------------------------- Head rotation
angle deg time ms moment N-m time ms decay time, ms
--------------------------------------------------------------------------------------------------------------------------------------------------------
004....................................... avg......................... 52.7 54.3 86.2 50.2 53.4
stdev....................... 1.58 1.47 2.23 3.75 0.88
%CV......................... 3.01 2.71 2.59 7.47 1.66
006....................................... avg......................... 53.5 54.6 89.2 51.1 52.8
stdev....................... 2.05 1.30 3.01 2.38 0.83
%CV......................... 3.82 2.38 3.38 4.67 1.56
007....................................... avg......................... 51.7 54.5 88.4 52.7 54.8
stdev....................... 1.75 1.13 2.57 2.74 2.17
%CV......................... 3.39 2.07 2.91 5.20 3.96
008....................................... avg......................... 54.2 55.6 86.7 51.2 51.6
stdev....................... 1.51 1.04 3.26 2.29 2.07
%CV......................... 2.79 1.88 3.76 4.47 4.01
All....................................... avg......................... 53.0 54.7 87.6 51.3 53.1
stdev....................... 1.93 1.29 2.96 2.89 1.94
%CV......................... 3.63 2.36 3.38 5.63 3.66
--------------------------------------------------------------------------------------------------------------------------------------------------------
Pelvis Impact
A lateral impact with the 3.8 kg probe at 4.0 m/s was used to test
the pelvis. Repeat tests were conducted according to the test
procedures described in the technical report, ``Qualification
Procedures for the Q3s Child Side Impact Crash Test Dummy,'' supra. For
each dummy in the evaluation, NHTSA conducted five impacts to both the
left and right side of the pelvis. A summary of the test results can be
found in Table 16 with left- and right-side tests combined.
The repeatability of each individual dummy's response was rated as
``EXCELLENT'' except for the peak pubic force response of dummy serial
number 006, which was rated as ``GOOD.'' For this particular dummy, the
pubic force was about 75 N higher for right side impacts than left side
impacts. For the other three dummies, the difference was only 50-60 N.
Despite the differences, repeatability--when assessed by combining
right and left impacts--only fell out of the ``EXCELLENT'' category for
dummy serial number 006. When left and right impacts for all dummies
were combined, reproducibility was rated as ``EXCELLENT'' for both the
peak pubic force and the peak probe force.
Table 16--Summary of Pelvis Qualification Test Responses
----------------------------------------------------------------------------------------------------------------
Pubic force Probe force
Dummy S/N Orientation L&R (N) (N)
----------------------------------------------------------------------------------------------------------------
004........................................... avg............................. 745.3 1651.0
stdev........................... 31.33 22.78
%CV............................. 4.20 1.38
006........................................... avg............................. 782.3 1698.9
stdev........................... 41.07 20.68
%CV............................. 5.25 1.22
007........................................... avg............................. 801.0 1679.1
stdev........................... 29.31 25.59
%CV............................. 3.66 1.52
008........................................... avg............................. 822.3 1738.1
stdev........................... 27.02 20.69
%CV............................. 3.29 1.19
All........................................... avg............................. 787.7 1691.8
stdev........................... 42.48 38.71
%CV............................. 5.39 2.29
----------------------------------------------------------------------------------------------------------------
VI. Qualification Tests
This NPRM proposes a set of qualification tests for the Q3s. In
general, Part 572 qualification tests assess the components that play a
key role in the dummy's performance in the intended regulatory
application. The tests qualify the dummy as an objective and suitable
test device for the assessment of occupant safety in compliance tests
specified in Federal motor vehicle safety standards, and for other
testing purposes. Performance within these corridors assures that the
dummy is capable of responding properly in a compliance or research
test, while performance outside of these corridors indicates the need
for adjustment, repair or replacement.
a. Overview of Proposed Corridors
Proposed qualification requirements for the Q3s are shown in Table
16. NHTSA has published a technical document, ``Qualification
Procedures for the Q3s Child Side Impact Crash Test Dummy (NHTSA,
2013),'' describing the equipment, test set-ups and procedures. A copy
of the report has been placed in the docket.
[[Page 69959]]
Table 17--Proposed Q3s Qualification Requirements
----------------------------------------------------------------------------------------------------------------
Test Measurement Units Corridor
----------------------------------------------------------------------------------------------------------------
Head--Frontal........................ Resultant acceleration. G 250-297
Head--Lateral........................ Resultant acceleration. G 113-140
Neck--Flexion........................ Maximum rotation....... deg 70-82
Time of max rotation... msec 55-63
Peak moment (My)....... N-m 41-51
Time of peak My........ msec 49-62
Decay time to 0 from msec 50-54
peak angle.
Neck--Lateral........................ Maximum rotation....... deg 77-88
Time of max rotation... msec 65-72
Peak moment (Mx)....... N-m 25-32
Time of peak Mx........ msec 66-73
Decay time to 0 from msec 63-69
peak angle.
Neck--Torsion........................ Maximum rotation....... deg 75-93
Time of max rotation... msec 91-113
Peak moment (Mz)....... N-m 8-10
Time of peak Mz........ msec 85-105
Decay time to 0 from msec 84-103
peak angle.
Shoulder............................. Lateral displacement... mm 16-21
Peak probe force....... kN 1.24-1.35
Thorax with Arm...................... Lateral displacement... mm 23-28
Peak probe force....... kN 1.38-1.69
Thorax without Arm................... Lateral displacement... mm 24-31
Peak probe force....... N 620-770
Lumbar--Flexion...................... Maximum rotation....... deg 48-57
Time of max rotation... msec 52-59
Peak moment (My)....... N-m 78-94
Time of peak My........ msec 46-57
Decay time to 0 from msec 50-56
peak angle.
Lumbar--Lateral...................... Maximum rotation....... deg 47-59
Time of max rotation... msec 50-59
Peak moment (Mx)....... N-m 78-97
Time of peak Mx........ msec 46-57
Decay time to 0 from msec 47-59
peak angle.
Pelvis............................... Peak pubic load........ N 700-870
Peak probe force....... kN 1.57-1.81
----------------------------------------------------------------------------------------------------------------
The bounds we have proposed for the qualification targets (the
corridors) are wide enough to account for normal variations in dummy
and laboratory differences, and narrow enough to assure consistent and
repeatable measurements in compliance testing. Our proposed bounds are
based on tests conducted at a single laboratory, NHTSA's Vehicle
Research and Test Center (VRTC). The data were collected using four Q3s
units. For each measurement, performance targets were derived using
either 3 standard deviations from the mean or 10 percent
from the mean, whichever is narrower. Upper and lower bounds were
rounded to the next whole number away from the mean using three
significant digits.
We recognize that from a probabilistic standpoint, three standard
deviations is an unusually wide bound. A bound of 10 percent around a
target is typical of most Part 572 ATD qualifications. Our reason for
initially setting the bounds to be wide for this NPRM stem from a
current lack of test data for the Q3s.\28\ Given that all Q3s
qualification data were collected from a single laboratory (VRTC), we
could not factor into account unknown variability associated with
different labs, operators, dummies, and other allowable variances such
as temperature and humidity that may not be present in our dataset. We
will continue to collect qualification data, and we will examine all
qualification data provided to us by commenters. We anticipate that
when new qualification data are combined with our current set of data,
in a final rule our bounds will be narrowed as reasonably possible and
may be no greater than two standard deviations.
---------------------------------------------------------------------------
\28\ For other Part 572 ATDs, we set qualification bounds by
examining data from multiple test labs, several dummies, and dummies
built by different dummy manufacturers. For example, the
qualification bounds for the HIII-10C (the most recent test dummy to
be incorporated into part 572) were derived from tests on about 30
different dummies, with data supplied from about 10 different
laboratories. On average, the bound widths for the HIII-10C are
about 10% of the mean, with a low of 7.4% and a high of 16.3%.
---------------------------------------------------------------------------
b. Rationale for the Tests
The technical document cited earlier in this preamble, ``Evaluation
of the Q3s Three Year-Old Child Side Impact Dummy, Repeatability,
Reproducibility, and Durability,'' discusses how the agency's four Q3s
units conform to the qualification requirements. This report also
discusses our rationale for the tests and proposed response
requirements needed to qualify the Q3s. For each test, the impact
energy level and the selection of the targeted measurements were chosen
by balancing multiple criteria, as described below.
Dummy Functionality
For each test, certain dummy sensors and signal characteristics
(such as the magnitude and timing) have been specified as qualification
targets. By monitoring these sensors, the qualification tests assure
that the dummy is functioning properly. Loose or damaged dummy hardware
is often manifested in a signal that does not conform to the
qualification requirements, thus alerting test technicians that dummy
maintenance may be needed. Conformity also assures that the sensors
themselves are working properly.
Test protocols are also designed to properly demonstrate dummy
functionality by mirroring dummy loading patterns seen in CRS sled
tests
[[Page 69960]]
conducted in support of the FMVSS No. 213 side impact test under
consideration. For example, we have observed the Q3s undergoing
asymmetric motion as the dummy simultaneously moves forward and
laterally. In doing so, the motion of the dummy is such that it may
twist itself around the edge of the CRS so that the head may strike the
door panel near its forehead. The degree to which the dummy wraps
around the seat can vary widely depending upon the design of the CRS.
Thus, we have included separate frontal and lateral qualification
requirements for the head.
We have also included separate requirements for the neck and lumbar
spine elements of the dummy, which are flexible rubber components that
experience both frontal and lateral flexion during a CRS test.
Additionally, a torsion test is prescribed for the neck since the
neck also twists along its long axis to some degree.
For the shoulder, thorax, and pelvis, we believe that only pure
lateral qualification requirements are needed, since almost all loads
pass through their lateral aspects even in cases where the dummy twists
within the CRS during testing.
Assure Biofidelity
Many of the qualification test protocols are very similar to the
dynamic tests used to assess biofidelity. This helps to assure that a
qualified dummy is also a biofidelic dummy.
Sufficient Energy
The impact speeds and probe masses have been selected to
demonstrate that the various body segments of the Q3s are working
properly at energy levels at or near those associated with injury
thresholds. These include pass/fail thresholds that we are considering
for the FMVSS No. 213 side impact test. For measurements not associated
with IARVs, such as the neck torsion requirement, the energy levels are
chosen to be consistent with high-end responses observed in CRS
testing. In general, the energy level is chosen to exercise the dummy
but without causing damage.
Proven Soundness of Part 572
To the extent possible, we have based the proposed test protocols
and devices on qualification tests set forth for other test dummies in
Part 572. The qualification tests have been proven reliable and sound
in qualifying NHTSA's other test dummies. Moreover, using the same
basic tests minimizes the amount of new qualification equipment needed
by test laboratories that may already have such equipment in place for
qualifying other ATDs.
c. New and Modified Part 572 Tests and Equipment
This NPRM proposes only one new test not found elsewhere in Part
572, a method to assure the functionality of the Q3s neck under
torsion. This is a fairly simple procedure added to assure that the
neck is repeatable under twist. The test involves the use of a special
test fixture attached to the Part 572 pendulum which imparts a pure
torsion moment to the isolated neck.
Additionally, a few minor changes to established Part 572 protocol
and equipment have been introduced to improve the ease and consistency
of the qualification tests. The pendulum probe used to qualify the Q3s
is specified to be 3.81 kg, which is about twice as large as the 1.70
kg probe used for the HIII-3C, Subpart P qualifications (Hybrid III 3-
year-old child test dummy used for frontal testing). This probe was
chosen to enable the same probe to be used for all Q3s qualification
tests that use a probe. The heavier probe allows a range of reasonable
test speeds to be used to attain the desired response level. Tests
speeds range from 3.6 m/s (shoulder impact) up to 5.0 m/s (thorax with
arm). In contrast, the test speed for the thorax test of the HIII-3C
with the lighter probe is 6.0 m/s.
We have also proposed a new test instrument for the flexion tests
of the neck and the lumbar spine. These tests measure relative rotation
by means of two angular rate sensors (ARSs). The ARSs that we specify
represent a relatively new technology. For similar tests with all other
Part 572 dummies, relative rotation is measured using a system of
rotary potentiometers and a linking rod. Because the potentiometer
system is mounted off-axis, it creates an asymmetry that can create
problems with a small dummy like the Q3s. We are concerned that the
added mass and inertia of a potentiometer system can introduce twisting
of the head simulator, which may affect the accuracy of the
measurements.
ARS units, on the other hand, are lightweight and compact. They do
not require a connecting rod and they can be mounted very near to the
headform's axis of symmetry so that their propensity to twist during a
test due to the added mass is greatly reduced. Furthermore, throughout
our testing of the Q3s the angular rate sensors have been observed to
produce very accurate measures of rotation. We tentatively conclude
that use of the ARS units in this application would be an improvement
over potentiometers.
d. Proposed Test Specifications and Performance Requirements
NHTSA proposes the following performance specifications for the
head in drop tests, and for the neck, shoulder, thorax, lumbar spine,
and pelvis in pendulum tests. Performance requirements in the lateral
direction must be met by carrying out the tests in the direction
opposing the primary load vector of the ensuing full scale test for
which the dummy is being qualified. For example, if the dummy is to be
used in an impact to the left side of a CRS, qualification tests on the
left aspect of the dummy's head, neck, shoulder, thorax, lumber spine,
and pelvis are carried out. The fore-aft performance requirements for
the head, neck, and lumbar spine must be met for all impact tests. That
is, in addition to the lateral tests, the fore-aft tests are conducted
on the ATD regardless of which side of the CRS is tested.
Head Drop Tests
The correct kinematic response of the head-neck system is of
substantial importance to quantify the protection offered by CRSs in
terms of head motion and acceleration during an impact. This test
serves to assure the uniformity of the impact response. Head
qualification consists of two test components: Frontal and lateral head
drops. The frontal head drop is conducted from a height of 376 mm,
while the lateral head drop is conducted at 200 mm.
The head must respond with peak resultant acceleration between: 250
g and 297 g when dropped from 376 mm height such that the forehead
lands onto a flat rigid surface; and between 113 g and 140 g when
dropped from a 200 mm height such that the side of the head lands onto
a flat rigid surface.
Neck Pendulum Test
We believe that a repeatable kinematic response of the head-neck
system is important to quantify the protection offered by CRSs in terms
of limiting head excursion and head acceleration in both a head impact
and a non-impact situation. Under the CRS test protocol under
consideration by the agency, the primary kinematic motion of the head
is in the lateral direction, but the head also twists and turns in
other directions to a lesser extent. Given the importance of head
motion, we believe a full set of neck qualification requirements is
warranted to assure uniformity. Therefore, our proposed neck
qualification consists of three test components: Frontal flexion,
lateral
[[Page 69961]]
flexion, and torsion neck pendulum tests.
The neck would have to allow the headform to articulate in pendulum
tests at:
4.7 m/s in frontal flexion, at between 70 degrees and 82
degrees occurring between 55 ms and 63 ms from time zero and decaying
back to the zero angle between 50 ms and 54 ms after the peak rotation;
the value of the maximum moment must be between 41 N-m and 51 N-m
occurring between 49 ms and 62 ms from time zero,
3.8 m/s in lateral flexion, at between 77 degrees and 88
degrees occurring between 65 ms and 72 ms from time zero and decaying
back to the zero angle between 63 ms and 69 ms after the peak rotation;
the value of the maximum moment must be between 25 N-m and 32 N-m
occurring between 66 ms and 73 ms from time zero, and
3.6 m/s in torsion, at between 75 degrees and 93 degrees
occurring between 91 ms and 113 ms from time zero and decaying back to
the zero angle between 84 ms and 103 ms after the peak rotation; the
value of the maximum moment must be between 8 N-m and 10 N-m occurring
between 84 ms and 103 ms from time zero.
Shoulder Impact Test
Though injury assessment is not generally associated with the
shoulder, the way the shoulder absorbs energy can affect the overall
kinematics of the dummy. This test assures that the shoulder acts
uniformly in the way it distributes the load under a direct lateral
impact.
The shoulder exposed to a pendulum impact at 3.6 m/s is to exhibit
a peak shoulder deflection between 16 mm and 21 mm, and a peak
resistance force between 1,240 N and 1,350 N.
Thorax Impact Tests
The thorax qualification tests are very similar to the SAE test
used to assess lateral thorax biofidelity. For qualification, however,
the test is conducted two ways: Without arm interaction (as in the SAE
test) and with the arm attached such that the impact probe strikes the
upper arm. Both tests utilize a lateral impact with a 3.8 kg probe.
The thorax ``without arm'' test assures uniformity of the thorax
structure, including its mount to the spine, and its response to a
direct impact in terms of rib deflection. The arm is completely removed
from the dummy. The 3.8 kg test probe is aligned with the thorax
displacement IR-TRACC and impacts the thorax laterally at a speed of
3.3 m/s.
For the ``arm attached'' test, the upper arm is positioned
vertically and aligned with the dummy's thorax. The lower arm is
positioned to make a 90 degree angle with the upper arm. The loading of
the ribcage goes through the arm. The impact speed of the probe is 5.0
m/s. This test assures uniformity of the arm in the way it absorbs
energy and interacts with the thorax under a direct lateral impact.
The thorax exposed to a pendulum impact:
At 3.3 m/s, without arm, is to exhibit a peak thorax
deflection between 24 mm and 31 mm, and a peak resistance force between
620 N and 770 N; and,
at 5.0 m/s, with arm attached, is to exhibit a peak thorax
deflection between 23 mm and 28 mm, and a peak resistance force between
1,380 N and 1,690 N occurring after 5 ms from time zero.
As explained previously, the peak probe force is taken after 5 ms
to separate the probe's initial inertial response during arm contact
from its response due to its interaction with the thorax. The net
effect of recording the peak probe force after 5 ms is the elimination
of the first peak.
Lumbar Tests
The rubber lumbar column bends to some extent during a CRS side
impact test. This bending might affect the overall kinematics of the
dummy, including the excursion of the head. It could also affect
lateral loads and the deflection of the thorax. We believe that this
rubber element can be a source of variability, so we have included a
qualification test to assure the uniformity and integrity of this
component.
Lumbar testing would consist of two types of pendulum tests: A
frontal test and a lateral test. For both tests, the lumbar spine
element containing the flexible column is removed from the dummy,
similar to the neck qualification tests. Lumbar tests are conducted
using the same Part 572 neck pendulum and headform device utilized in
the neck qualification tests. In the case of lumbar qualification, the
headform is not intended to represent the inertial properties of any
particular body region, but merely provides an apparatus that helps to
ensure a repeatable test condition. The frontal and lateral pendulum
tests are conducted at the same impact speed of 4.4 m/s and specify the
same pendulum impulse.
We propose that the lumbar spine must allow the headform to
articulate:
In frontal flexion, at not less than between 48 degrees
and 57 degrees occurring between 52 ms and 59 ms from time zero and
decaying back to zero angle between 50 ms and 56 ms after the peak
rotation; the value of the maximum moment must be between 78 N-m and 94
N-m occurring between 46 ms and 57 ms from time zero; and,
in lateral flexion, at not less than between 47 degrees
and 59 degrees occurring between 50 ms and 59 ms from time zero and
decaying back to zero angle between 47 ms and 59 ms after the peak
rotation; the value of the maximum moment must be between 78 N-m and 97
N-m occurring between 46 ms and 57 ms from time zero.
Pelvis Impact
A lateral impact with the 3.8 kg probe at 4.0 m/s is used to test
the pelvis. This test protocol is very similar to the SAE biofidelity
test. The pelvis exposed to a pendulum impact at 4.0 m/s is to exhibit
a peak pubic load between 700 N and 870 N, and a peak force measured by
the pendulum between 1570 N and 1810 N.
Other
We have not included a qualification test aimed specifically at the
Q3s abdomen. We tentatively believe that any non-uniformity in
stiffness due to the absence of a qualification requirement for the
abdomen would have an insignificant effect on the overall kinematics of
the dummy in a side impact test. Also, the abdomen of the Q3s is
uninstrumented and is thus not generally used to assess injury
potential in a side impact.
Nevertheless, comments are requested on the need for a
qualification test for the abdomen. The abdomen is made of a high
density, compressible foam material, whose compressive characteristics
can vary from one abdomen to another and whose properties can change
with aging and other factors. We request comments on an abdominal test
protocol similar to that which we used to assess the biofidelity of the
Q3s abdomen.
VII. Durability
No durability problems arose with the Q3s dummies in any of the
sled tests or component tests.
a. High-Energy Component Tests
We also conducted high-energy component tests to assess durability
and no durability problems arose in those. In these tests, we raised
the kinetic energy of the impact to levels that exposed the dummy to
loading conditions slightly greater than those that might be
[[Page 69962]]
expected in the dummy's regulatory application. High-energy tests were
conducted for the head, neck, shoulder, thorax (with and without arm),
lumbar, and pelvis. As discussed below, we found no damage to the
dummy's structural components or instrumentation.
High-Energy Head Drop Tests
We performed frontal and lateral head drop tests using the
qualification test setup procedures, except the drop heights were
increased to achieve kinetic energy increases of 10 percent, 20
percent, and 30 percent, as compared to the standard qualification
test.
Frontal head drop responses are summarized in Table 18. The peak
resultant head acceleration at 30 percent increased energy was 318.5 g.
This impact resulted in a HIC15 value of 1732.5, which is well above
the proposed injury criterion limit of 700 and demonstrates the
severity of the test. Post-test inspection of the head revealed no
structural damage to the synthetic skull material or to the vinyl skin.
Lateral head drop responses are summarized in Table 19. For the
most severe condition, the peak resultant head acceleration was 146.6
g. No structural damage of the head was observed in the post-test
inspection of the head assembly.
Table 18--High-Energy Frontal Head Drop Test Responses
----------------------------------------------------------------------------------------------------------------
Energy
increase Drop height Peak
Test No. (nominal) (mm) resultant
(percent) accel (g)
----------------------------------------------------------------------------------------------------------------
Baseline........................................................ 0 376 265.5
1............................................................... 10 414 284.6
2............................................................... 20 451 304.4
3............................................................... 30 489 318.5
----------------------------------------------------------------------------------------------------------------
Table 19--High-Energy Lateral Head Drop Test Responses
----------------------------------------------------------------------------------------------------------------
Energy
increase Drop height Peak
Test No. (nominal) (mm) resultant
(percent) accel (g)
----------------------------------------------------------------------------------------------------------------
Baseline........................................................ 0 200 121.5
1............................................................... 10 220 127.3
2............................................................... 20 240 141.6
3............................................................... 30 260 146.6
----------------------------------------------------------------------------------------------------------------
High-Energy Neck Pendulum Tests
We conducted frontal, lateral, and torsional neck pendulum tests at
the increased impact speeds. Tests were conducted according to the
qualification procedures, except for the increase in impact speeds.
Frontal Flexion Tests. The results of the high-energy frontal neck
flexion tests are summarized in Table 20. Three repeat tests were run
at 5.5 m/s. This speed represents a 34 percent increase in energy over
the qualification speed. We chose this condition because it is
consistent with the test protocol used to qualify the HIII-3C (a
frontal impact dummy). We found no signs of damage or unusual wear to
the Q3s neck or neck cable at the elevated speed. The response curves
were smooth, indicating that no unusual contact occurred during the
tests. The tests also demonstrate that the Q3s neck would be repeatable
if the dummy were used in a frontal impact mode.
Lateral Flexion Tests. The results of the high-energy lateral neck
flexion tests are summarized in Table 21. Incremental tests were run at
impact speeds needed to achieve increases in kinetic energy of 10
percent, 20 percent, and 30 percent. In all cases, the response signals
were smooth with no indication of damage.
Torsion Tests. The high-energy neck torsion tests were also run at
impact speeds needed to achieve energy increases of 10 percent, 20
percent, and 30 percent. The responses are summarized in Table 22. In
all cases, the response signals were smooth with no indication of
damage.
Table 20--Frontal Flexion Neck Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Energy Max angle Peak Y-moment
increase Impact speed, ---------------------------------------------------------------- Head rotation
Test No. (nominal) m/s decay time,
(percent) angle deg time ms moment N-m time ms m/s
--------------------------------------------------------------------------------------------------------------------------------------------------------
Baseline................................ 0 4.7 74.0 58.2 44.9 54.1 51.5
1....................................... 34 5.5 78.8 55.9 62.3 53.0 48.0
2....................................... 34 5.5 80.1 55.4 66.0 52.7 47.7
3....................................... 34 5.5 79.4 57.0 63.2 53.2 47.6
--------------------------------------------------------------------------------------------------------------------------------------------------------
[[Page 69963]]
Table 21--Lateral Flexion Neck Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Energy Max angle Peak Y-moment
increase Impact speed, ---------------------------------------------------------------- Head rotation
Test No. (nominal) m/s decay time,
(percent) angle deg time ms moment N-m time ms m/s
--------------------------------------------------------------------------------------------------------------------------------------------------------
baseline................................ 0 3.8 80.9 68.7 26.9 70.2 64.8
1....................................... 10 4.0 82.3 68.9 27.1 70.1 65.5
2....................................... 20 4.2 85.1 67.2 31.9 66.8 63.2
3....................................... 30 4.3 86.8 66.8 34.3 66.3 62.3
--------------------------------------------------------------------------------------------------------------------------------------------------------
Table 22--Neck Torsion Pendulum Test Responses
--------------------------------------------------------------------------------------------------------------------------------------------------------
Impact Max angle Peak Z-Moment Head
Energy speed ---------------------------------------------------- rotation
Test No. increase ------------- angle time moment time decay time
(nominal) ----------------------------------------------------------------
(percent) m/s Deg Ms N-m ms ms
--------------------------------------------------------------------------------------------------------------------------------------------------------
baseline..................................................... 0 3.6 80.9 99.5 9.35 92.1 88.7
1............................................................ 10 3.8 83.3 102.9 9.35 95.5 91.7
2............................................................ 20 3.9 83.8 101.5 9.40 95.0 91.2
3............................................................ 30 4.1 87.4 103.1 9.73 96.9 91.0
--------------------------------------------------------------------------------------------------------------------------------------------------------
High-Energy Shoulder Impact Tests
The agency conducted shoulder impacts according to the
qualification test setup procedures, except the impact speeds were
increased to achieve increases in kinetic energy of approximately 10
percent, 20 percent, and 30 percent as compared to the qualification
test. Table 23 provides a summary of the responses for the high-energy
shoulder impact tests. At the 30 percent increased energy level, the
peak lateral shoulder deflection was 20.4 mm and the response curve was
smooth, indicating that the shoulder string pot did not reach its
maximum allowable stroke. The peak probe force was 1450 N. Post-test
inspections revealed no structural damage to the dummy or
instrumentation.
Table 23--High-Energy Shoulder Impact Test Responses
----------------------------------------------------------------------------------------------------------------
Energy increase Shoulder
Test No. (nominal) Impact speed (m/ displacement Probe force (N)
(percent) s) (mm)
----------------------------------------------------------------------------------------------------------------
baseline................................ 0.0 3.6 17.6 1269
1....................................... 10 3.8 19.7 1348
2....................................... 20 4.0 20.1 1443
3....................................... 30 4.1 20.4 1450
----------------------------------------------------------------------------------------------------------------
High-Energy Thorax Impact Tests
We conducted high-energy thorax impact tests with and without the
arm. We followed the set-up procedures used in the qualification tests,
except we increased the probe impact speeds to supply a corresponding
increase in the kinetic energy.
For the ``with arm'' tests, we conducted one impact at 20 percent
increased kinetic energy and two at a 30 percent increase. Table 24
summarizes the responses for the high-energy thorax with arm impacts.
The highest lateral thorax displacement was 28.7 mm and the response
curve was smooth. Post-test inspections demonstrated that no damage
occurred to any portion of the dummy's torso.
For the thorax ``without arm'' test condition (Table 25), because
thorax durability was a concern with earlier versions of the Q3s, we
conducted tests at higher severity levels to provide a rigorous
assessment of the durability of the thorax. For the thorax ``without
arm'' test condition, we conducted an impact at 50 percent increased
kinetic energy and another impact at a 70 percent increase. No
structural damage was observed during post-test inspections of the
dummy's thorax and IR-TRACC displacement transducer.
In addition, for the thorax ``without arm'' test condition, we
conducted tests at increased severity levels to assess further the
durability of the IR-TRACC device. The maximum allowable lateral thorax
displacement before damage occurs to the IR-TRACC displacement
measurement device is approximately 40 mm. Considering this physical
limitation, we increased the probe impact speed until the lateral
displacement approached 38 mm. We found that the impact speed
corresponding to roughly 38 mm of displacement was 4.4 m/s
(approximately an 80 percent increase in kinetic energy). Accordingly,
we conducted two additional impact tests at that speed. For the three
tests conducted at 80 percent increased kinetic energy, the lateral
thorax displacement ranged from 37.1-37.9 mm and the response curves
were smooth, indicating that the transducer did not exceed its maximum
allowable stroke. No structural damage was observed during post-test
inspections of the dummy's thorax and IR-TRACC displacement transducer.
[[Page 69964]]
Table 24--High-Energy Thorax With Arm Impact Test Responses
----------------------------------------------------------------------------------------------------------------
Energy increase Thorax
Test No. (nominal) Impact speed (m/ displacement Probe force (N)
(percent) s) (mm)
----------------------------------------------------------------------------------------------------------------
baseline................................ 0 5.0 25.0 1526
1....................................... 20 5.5 27.0 1663
2....................................... 30 5.7 28.3 1625
3....................................... ................ ................ 28.7 1652
----------------------------------------------------------------------------------------------------------------
Table 25--High-Energy Thorax Without Arm Impact Test Responses
----------------------------------------------------------------------------------------------------------------
Energy increase Thorax
Test No. (nominal) Impact speed (m/ displacement Probe force (N)
(percent) s) (mm)
----------------------------------------------------------------------------------------------------------------
baseline................................ 0 3.3 26.0 732
1....................................... 50 4.0 32.8 784
2....................................... 70 4.3 36.2 772
3....................................... 80 4.4 37.9 799
4....................................... ................ ................ 37.3 814
5....................................... ................ ................ 37.1 815
----------------------------------------------------------------------------------------------------------------
High-Energy Lumbar Pendulum Tests
We conducted high-energy frontal and lateral lumbar pendulum tests
according to the qualification test set-up procedures, except the
impact speeds were increased. For frontal pendulum tests, the impact
energy was increased up to approximately 30 percent greater than the
qualification test, while lateral tests were increased up to
approximately 40 percent greater than the qualification test.
The frontal test results are summarized in Table 26 and the lateral
results are summarized in Table 27. The lumbar moment and rotation
responses did not indicate any unusual issues with the lumbar spine
element or load cell in either of the test conditions. No damage or
delamination was observed in post-test inspections of the lumbar
components.
Table 26--High-Energy Frontal Lumbar Pendulum Test Responses
----------------------------------------------------------------------------------------------------------------
Energy Max angle Peak Y-moment
increase Impact ------------------------------------- Head rotation
Test No. (nominal) speed, m/s Angle Moment N- decay time, ms
(percent) deg Time ms m Time ms
----------------------------------------------------------------------------------------------------------------
Baseline......................... 0 4.4 53.3 56.6 85.7 53.9 54.2
1................................ 20 4.8 57.5 56.8 88.6 51.9 55.0
2................................ 30 5.0 60.3 57.5 95.6 53.5 55.0
----------------------------------------------------------------------------------------------------------------
Table 27--High-Energy Lateral Lumbar Pendulum Test Responses
----------------------------------------------------------------------------------------------------------------
Energy Max angle Peak Y-moment
increase Impact ------------------------------------- Head rotation
Test No. (nominal) speed, m/s Angle Moment N- decay time, ms
(percent) deg Time ms m Time ms
----------------------------------------------------------------------------------------------------------------
Baseline......................... 0 4.4 53.9 56.0 83.5 50.3 49.2
1................................ 20 4.8 59.0 57.3 95.7 54.0 54.0
2................................ 30 5.0 60.7 57.4 100.8 54.0 54.0
3................................ 40 5.2 62.9 56.6 107.7 53.3 53.3
----------------------------------------------------------------------------------------------------------------
High-Energy Pelvis Impact Tests
We conducted high-energy pelvis impacts in accordance with the
qualification test set-up procedures, except we increased impact speeds
to achieve increases in kinetic energy of approximately 15 percent, 40
percent, and 55 percent. The responses for the high-energy pelvis
impact tests are summarized in Table 28. At the highest energy level,
the lateral pubic load was 1057 N (well beyond the 450 N maximum
observed in the Cozy Cline R&R series) and the probe force was 2357 N.
Analysis of the lateral pubic load response revealed a smooth curve,
indicating no unusual contact internal to the dummy. No damage to the
pelvis region was observed during post-test inspections.
[[Page 69965]]
Table 28--High-Energy Pelvis Impact Test Responses
------------------------------------------------------------------------
Energy
Increase Impact Pubic Probe
Test No. (nominal) speed force force
(percent) (m/s) (N) (N)
------------------------------------------------------------------------
baseline....................... 0.0 4.0 796 1712
1.............................. 15 4.3 843 1896
2.............................. 40 4.7 1001 2209
3.............................. 55 5.0 1057 2357
------------------------------------------------------------------------
b. Q3s Servicing and Maintenance
In our experience with other Part 572 ATDs, deformable parts
typically have the shortest service lives. The two most often replaced
parts are the ribcage and the molded neck. For example, we have found
the typical service life for HIII-10C rib sets and neck assemblies to
be about thirty sled tests. Vinyl flesh materials--particularly the
chest flesh--are also replaced on a recurring basis as they become
aged, abraded, or torn.
NHTSA owns four Q3s units of the final Build Level D version, which
include the updated parts to improve the durability of the thorax,
neck, and pelvis. There have been no durability problems with the ATDs
since they have been upgraded to the latest build level. Given the
record of low maintenance to our own Q3s units, we consider the dummy
to be highly suitable for proposed use in FMVSS No. 213 in terms of its
durability. Our records indicate that we have had relatively few
instances of Q3s part replacements of any sort.
VIII. Drawings and Patents
Throughout the notice and comment period of this Part 572
rulemaking, the Q3s dummy will be available from Humanetics. The Q3s
engineering drawings used to fabricate the dummy are available in the
docket for public review and comment. The Q3s engineering drawings are
a proprietary product owned by Humanetics,\29\ with the exceptions
noted in this section. Thus, during the comment period most drawings
will display the Humanetics name in the title block and will have the
following restrictive note:
---------------------------------------------------------------------------
\29\ FTSS/Humanetics' development of the Q3s dummy was not
performed directly under a government research and development
contract. NHTSA procured its Q3s units under a standard purchase
order in which the FTSS/Humanetics products were listed within a
catalog with a price schedule. Using this same purchase mechanism,
our units were periodically sent back to FTSS/Humanetics for
warranty maintenance and upgrades. As we performed subsequent tests
on our Q3s units, we routinely shared our results with FTSS/
Humanetics, and concurrently reported them in public and in SAE and
ISO committee meetings, providing test results, identifying
problems, and suggesting ways to correct problems. FTSS/Humanetics
produced parts based on this information, and periodically provided
new components to NHTSA for evaluation.
This drawing is the sole property of Humanetics Innovative
Solutions, Inc. and is being provided to NHTSA and other related
organizations for evaluation and comment related to NHTSA's
rulemaking process. Except for commenting purposes pursuant to this
process, the drawing shall not be copied or used for any other
purpose without the written consent of Humanetics Innovative
---------------------------------------------------------------------------
Solutions, Inc.
For the final rule, the note will be removed and the dummy drawings
and designs will be free from any restrictions. This includes their use
in fabrication and in building computer simulation models of the dummy.
During this comment period, some drawings will not have the
Humanetics name in the title block and will not have the restrictive
note on them. In these cases, NHTSA contracted with Humanetics to
provide the part or expressly contributed to the design of the part. As
described earlier in this preamble, Humanetics fabricated the Build
Level D neck using detailed specifications provided by NHTSA. These
specifications included detailed engineering drawings and a prototype
of the neck itself. In addition, NHTSA also contributed to the design
of the femur, hip, and several other minor parts of the dummy.
The list of drawings related to those agency's efforts is shown in
Table 29. On these drawings, the NHTSA name appears in the title block
and the restrictive note does not appear. These drawings are available
to the public for use during this NPRM stage without restriction.
NHTSA is aware that Humanetics has filed a patent application with
the United States Patent and Trademark Office covering certain parts of
the Q3s dummy. Prior to the publication of any final rule, NHTSA plans
to meet with Humanetics and come to some agreement that ensures the
continued availability of the Q3s dummy to the general public at a
reasonable price. Notwithstanding the intellectual property issues
identified in this section, NHTSA emphasizes that readers should take
this opportunity to review the information provided in this NPRM and
provide responses on the substantive aspects of the proposal.
Table 29--List of Q3s Drawings for Which No Restrictive Note Appears
----------------------------------------------------------------------------------------------------------------
Drawing No. Description Used on
----------------------------------------------------------------------------------------------------------------
020-2400................................. Neck assembly, Q3s.......... 020-2400
020-2401................................. Molded neck, Q3s............ 020-2400
020-2402................................. Neck plate, top Q3s......... 020-2400
020-2403................................. Neck plate, middle, Q3s..... 020-2400
020-2404................................. Neck plate, bottom, Q3s..... 020-2400
020-2405................................. Retaining ring, Q3s neck.... 020-2400
020-2406................................. Square crimp, Q3s neck...... 020-2400
020-2407................................. Bottom crimp, Q3s neck cable 020-2400
020-2408................................. Neck cable assembly, Q3s.... 020-2400
020-2409................................. Retaining nut, Q3s neck..... 020-2400
020-9611................................. Femur, Right................ 020-9616
020-9511................................. Femur, Left................. 020-9516
020-9607................................. Femur reinforcement, Right.. 020-9616
[[Page 69966]]
020-9507................................. Femur reinforcement, Left... 020-9516
020-3537................................. Ball shoulder............... 020-9616, 020-9516
020-9903................................. End stop.................... 020-9616, 020-9516
020-7116................................. Hip joint assembly, Right... 020-7116
020-7113................................. Hip joint assembly, Left.... 020-7113
020-7115................................. Hip cup assembly, Right..... 020-7116, 020-7113
020-7114................................. Hip cup assembly, Left...... 020-7116, 020-7113
020-7117................................. Hip cup, upper.............. 020-7116, 020-7113
020-7118................................. Hip cup, lower.............. 020-7116, 020-7113
020-7103................................. Detent peg.................. 020-7116, 020-7113
020-7104................................. Spring retainer plate....... 020-7116, 020-7113
020-9000................................. Q3s positioning tool........ 020-9000
020-9001................................. Indicator arm............... 020-9000
020-9002................................. Extension bracket........... 020-9000
020-9003................................. Cross beam.................. 020-9000
020-9004................................. Knee spacer................. 020-9000
020-9005................................. Pivot screw................. 020-9000
----------------------------------------------------------------------------------------------------------------
IX. Consideration of Alternatives
We considered the merits of alternative test dummies for use in the
side impact test under consideration for FMVSS No. 213. The closest
viable alternatives were the modified Hybrid III 3-year-old child test
dummy (HIII-3C) and the Q3.
Consideration of the Modified HIII-3C (``3Cs'')
The HIII-3C was originally developed in 1992. It is used in FMVSS
No. 208, ``Occupant crash protection,'' to evaluate air bag
aggressiveness or air bag suppression when a child is close to a
deploying air bag, and in FMVSS No. 213's frontal sled test for the
evaluation of child restraint performance. The HIII-3C was not designed
for lateral impacts. Under lateral loading, the shoulder and torso
exhibit highly stiff behavior and do not fully replicate a child's
kinematics. NHTSA considered using the HIII-3C in the 2002 FMVSS No.
213 ANPRM published in response to the TREAD Act (see footnote 4,
supra), but concluded that the ATD was not acceptable for use in side
impact testing.
After the agency assessed the HIII-3C in side impacts, NHTSA
developed a retrofit package for the dummy to install a new head and
neck with better lateral biofidelity. The retrofitted dummy is referred
to as the ``3Cs.''
NHTSA evaluated the 3Cs and the Q3s concurrently. Based on our
biofidelity evaluations, the 3Cs did not achieve nearly as good a
ranking as the Q3s. The technical report, ``Biofidelity Assessment of
the Q3s Three-Year-Old Child Side Impact Dummy,'' supra, discusses the
performance of the two ATDs. The Q3s outperformed or is equivalent to
the 3Cs in every aspect of biofidelity related to a dummy's response in
a side impact. Given the superior biofidelity of the Q3s, we believe
that it more accurately represents the response expected of a human
child.
In addition, the Q3s has thorax deflection instrumentation, which
the 3Cs does not. We tentatively conclude that the Q3s is a better
dummy than the 3Cs to measure injury assessment values in side impacts
and is a preferable ATD for use in the proposed side impact upgrade to
FMVSS No. 213.
Consideration of the Q3
As discussed in section II of this preamble, the design of the Q3s
was derived from the original Q3 dummy developed by the European
community. The Q3 is intended for use in frontal, side, and rear
impacts.
Around the same time Humanetics was working to bring the Q3s up to
production level, the Q3 underwent a significant design revision.
Starting in 2003, a ``new'' Q3 took shape. Many of the new design
concepts included in the Q3s were also built into the Q3 as Humanetics
worked concurrently on both dummies (e.g., thorax string potentiometers
were replaced by IR-TRACCs in both dummies). Still, as reported by the
European Enhanced Vehicle-Safety Committee (Wismans, et al., 2008), the
new Q3 does not respond well in lateral biofidelity tests. Furthermore,
the thorax of the new Q3 has become even less biofidelic than the
original. Therefore, NHTSA does not consider the Q3 preferable to the
Q3s.
Conclusion
The agency tentatively concludes that the improved biofidelity and
additional injury assessment capability of the Q3s compared to the
other commercially available child side impact test dummies supports a
decision to adopt the Q3s into 49 CFR Part 572. The Q3s dummy is a
state-of-the-art device that would allow for a better assessment of the
risk of injury to child occupants than the alternative test dummies.
The availability of Q3s's injury measuring capability also is important
to the design, development and evaluation of the side impact protection
of child restraint systems. The Q3s test dummy is available today, and
has been thoroughly evaluated for suitable reproducibility and
repeatability of results.
X. Rulemaking Analyses and Notices
Executive Order (E.O.) 12866 and E.O. 13563, and DOT Regulatory
Policies and Procedures
NHTSA has considered the impacts of this regulatory action under
E.O. 12866 and E.O. 13563. This rulemaking action was not reviewed by
the Office of Management and Budget under E.O. 12866. The rulemaking
has also been determined to be non-significant under DOT's regulatory
policies and procedures.
This document would amend 49 CFR Part 572 by adding design and
performance specifications for a test dummy representative of a 3-year-
old child that the agency would possibly use in FMVSS No. 213 side
impact compliance tests and possibly for research purposes. This Part
572 proposed rule would not impose any requirements on anyone.
Businesses are affected only if they choose to manufacture or test with
the dummy. Because the economic impacts of this proposed rule are
minimal, no further regulatory evaluation is necessary.
There are benefits associated with this rulemaking but they cannot
be quantified. The incorporation of the test dummy into 49 CFR Part 572
would
[[Page 69967]]
enable NHTSA to use the ATD in a new dynamic side impact test that we
are considering adopting into FMVSS No. 213. Adoption of side impact
protection requirements in FMVSS No. 213 enhances child passenger
safety and accords with MAP-21. In addition, the availability of this
dummy in a regulated format would be beneficial by providing a
suitable, stabilized, and objective test tool to the safety community
for use in better protecting children in side impacts.
The cost of an uninstrumented Q3s dummy is approximately $48,750.
The minimum set of instrumentation needed for qualification and
compliance type testing includes three uni-axial accelerometers (part
no. SA572-S4), one neck/spine load cell (SA572-S8), one shoulder
potentiometer set (SA572-S38 and S39), one single axis IR-TRACC (SA572-
S37), and one pubic load cell (SA572-S7). The cost of this
instrumentation adds approximately $18,200 for a total cost of about
$66,950.
We have not estimated the costs of the equipment needed to perform
the qualification tests other than the instrumentation needed (two
angular rate sensors, $1,230 apiece; one test probe accelerometer,
$500; one rotary potentiometer, $500.) With the exception of the neck
torsion fixture, the angular rate sensors, and the 3.8 kg test probe,
all fixtures and instruments are common with those used to qualify
other Part 572 dummies.
We recognize that dummy refurbishments and part replacements are an
inherent part of ATD testing. Various parts will likely have to be
refurbished or replaced, but we do not know which parts are likely to
be worked on the most. However, since the dummies are designed to be
reusable, costs of the dummies and of parts can be amortized over a
number of tests.
Regulatory Flexibility Act
Pursuant to the Regulatory Flexibility Act (5 U.S.C. 601 et seq.,
as amended by the Small Business Regulatory Enforcement Fairness Act
(SBREFA) of 1996), whenever an agency is required to publish a proposed
or final rule, it must prepare and make available for public comment a
regulatory flexibility analysis that describes the effect of the rule
on small entities (i.e., small businesses, small organizations, and
small governmental jurisdictions), unless the head of the agency
certifies the rule will not have a significant economic impact on a
substantial number of small entities. The Small Business
Administration's regulations at 13 CFR Part 121 define a small
business, in part, as a business entity ``which operates primarily
within the United States.'' (13 CFR 121.105(a)).
We have considered the effects of this rulemaking under the
Regulatory Flexibility Act. I hereby certify that this rulemaking
action would not have a significant economic impact on a substantial
number of small entities. This action would not have a significant
economic impact on a substantial number of small entities because the
addition of the test dummy to Part 572 would not impose any
requirements on anyone. NHTSA would use the ATD in agency testing but
would not require anyone to manufacture the dummy or to test motor
vehicles or motor vehicle equipment with it.
National Environmental Policy Act
NHTSA has analyzed this proposed rule for the purposes of the
National Environmental Policy Act and determined that it would not have
any significant impact on the quality of the human environment.
Executive Order 13045 and 13132 (Federalism)
Executive Order 13045 (62 FR 19885, April 23, 1997) applies to any
rule that: (1) Is determined to be ``economically significant'' as
defined under E.O. 12866, and (2) concerns an environmental, health, or
safety risk that NHTSA has reason to believe may have a
disproportionate effect on children. If the regulatory action meets
both criteria, we must evaluate the environmental health or safety
effects of the planned rule on children, and explain why the planned
regulation is preferable to other potentially effective and reasonably
feasible alternatives considered by us.
This proposed rule is not subject to the Executive Order because it
is not economically significant as defined in E.O. 12866.
NHTSA has examined today's proposed rule pursuant to Executive
Order 13132 (64 FR 43255, August 10, 1999) and concluded that no
additional consultation with States, local governments or their
representatives is mandated beyond the rulemaking process. The agency
has concluded that the proposed rule would not have federalism
implications because the proposed rule would not have ``substantial
direct effects on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government.'' This
proposed rule would not impose any requirements on anyone. Businesses
will be affected only if they choose to manufacture or test with the
dummy.
Further, no consultation is needed to discuss the preemptive effect
of today's proposed rule. NHTSA's safety standards can have preemptive
effect in two ways. This proposed rule would amend 49 CFR Part 572 and
is not a safety standard.\30\ This Part 572 proposed rule would not
impose any requirements on anyone.
---------------------------------------------------------------------------
\30\ With respect to the safety standards, the National Traffic
and Motor Vehicle Safety Act contains an express preemptive
provision: ``When a motor vehicle safety standard is in effect under
this chapter, a State or a political subdivision of a State may
prescribe or continue in effect a standard applicable to the same
aspect of performance of a motor vehicle or motor vehicle equipment
only if the standard is identical to the standard prescribed under
this chapter.'' 49 U.S.C. 30103(b)(1). Second, the Supreme Court has
recognized the possibility of implied preemption: State requirements
imposed on motor vehicle manufacturers, including sanctions imposed
by State tort law, can stand as an obstacle to the accomplishment
and execution of a NHTSA safety standard. When such a conflict
exists, the Supremacy Clause of the Constitution makes the State
requirements unenforceable. See Geier v. American Honda Motor Co.,
529 U.S. 861 (2000).
---------------------------------------------------------------------------
Civil Justice Reform
With respect to the review of the promulgation of a new regulation,
section 3(b) of Executive Order 12988, ``Civil Justice Reform'' (61 FR
4729, February 7, 1996) requires that Executive agencies make every
reasonable effort to ensure that the regulation: (1) Clearly specifies
the preemptive effect; (2) clearly specifies the effect on existing
Federal law or regulation; (3) provides a clear legal standard for
affected conduct, while promoting simplification and burden reduction;
(4) clearly specifies the retroactive effect, if any; (5) adequately
defines key terms; and (6) addresses other important issues affecting
clarity and general draftsmanship under any guidelines issued by the
Attorney General. This document is consistent with that requirement.
Pursuant to this Order, NHTSA notes as follows.
The issue of preemption is discussed above in connection with E.O.
13132. NHTSA notes further that there is no requirement that
individuals submit a petition for reconsideration or pursue other
administrative proceeding before they may file suit in court.
Paperwork Reduction Act
Under the Paperwork Reduction Act of 1995, a person is not required
to respond to a collection of information by a Federal agency unless
the collection displays a valid control number from the Office of
Management and Budget (OMB). This proposed rule would not have any
requirements that are considered to be information
[[Page 69968]]
collection requirements as defined by the OMB in 5 CFR Part 1320.
National Technology Transfer and Advancement Act
Section 12(d) of the National Technology Transfer and Advancement
Act of 1995 (NTTAA), Public Law 104-113, section 12(d) (15 U.S.C. 272)
directs NHTSA to use voluntary consensus standards in its regulatory
activities unless doing so would be inconsistent with applicable law or
otherwise impractical. Voluntary consensus standards are technical
standards (e.g., materials specifications, test methods, sampling
procedures, and business practices) that are developed or adopted by
voluntary consensus standards bodies. The NTTAA directs NHTSA to
provide Congress, through OMB, explanations when the agency decides not
to use available and applicable voluntary consensus standards.
The following voluntary consensus standards have been used in
developing the Q3s:
SAE Recommended Practice J211, Rev. Mar 95,
``Instrumentation for Impact Tests--Part 1--Electronic
Instrumentation''; and,
SAE J1733 of 1994-12 ``Sign Convention for Vehicle Crash
Testing.''
Unfunded Mandates Reform Act
Section 202 of the Unfunded Mandates Reform Act of 1995 (UMRA),
Public Law 104-4, requires Federal agencies to prepare a written
assessment of the costs, benefits, and other effects of proposed or
final rules that include a Federal mandate likely to result in the
expenditure by State, local, or tribal governments, in the aggregate,
or by the private sector, of more than $100 million annually (adjusted
for inflation with base year of 1995). Before promulgating a NHTSA rule
for which a written statement is needed, section 205 of the UMRA
generally requires the agency to identify and consider a reasonable
number of regulatory alternatives and adopt the least costly, most
cost-effective, or least burdensome alternative that achieves the
objectives of the rule.
This proposed rule would not impose any unfunded mandates under the
UMRA. This proposed rule does not meet the definition of a Federal
mandate because it does not impose requirements on anyone. It amends 49
CFR Part 572 by adding design and performance specifications for a 3-
year-old child side impact test dummy that the agency could use in
FMVSS No. 213 and for research purposes. This proposed rule would
affect only those businesses that choose to manufacture or test with
the dummy. It would not result in costs of $100 million or more to
either State, local, or tribal governments, in the aggregate, or to the
private sector.
Plain Language
Executive Order 12866 requires each agency to write all rules in
plain language. Application of the principles of plain language
includes consideration of the following questions:
Has the agency organized the material to suit the public's needs?
Are the requirements in the rule clearly stated?
Does the rule contain technical language or jargon that is not
clear?
Would a different format (grouping and order of sections, use of
headings, paragraphing) make the rule easier to understand?
Would more (but shorter) sections be better?
Could the agency improve clarity by adding tables, lists, or
diagrams?
What else could the agency do to make this rulemaking easier to
understand?
If you have any responses to these questions, please send them to
NHTSA.
Regulation Identifier Number
The Department of Transportation assigns a regulation identifier
number (RIN) to each regulatory action listed in the Unified Agenda of
Federal Regulations. The Regulatory Information Service Center
publishes the Unified Agenda in April and October of each year. You may
use the RIN contained in the heading at the beginning of this document
to find this action in the Unified Agenda.
XI. Public Participation
How do I prepare and submit comments?
Your comments must be written and in English. To ensure better that
your comments are correctly filed in the Docket, please include the
docket number of this document in your comments.
Your comments must not be more than 15 pages long. (49 CFR 553.21).
We established this limit to encourage you to write your primary
comments in a concise fashion. However, you may attach necessary
additional documents to your comments. There is no limit on the length
of the attachments.
Comments may also be submitted to the docket electronically by
logging into https://www.regulations.gov. Follow the online instructions
for submitting comments.
Please note that pursuant to the Data Quality Act, in order for
substantive data to be relied upon and used by the agency, it must meet
the information quality standards set forth in the OMB and DOT Data
Quality Act guidelines. Accordingly, we encourage you to consult the
guidelines in preparing your comments. OMB's guidelines may be accessed
at https://www.whitehouse.gov/omb/fedreg/reproducible.html.
How can I be sure that my comments were received?
If you wish the Docket Management Facility to notify you upon its
receipt of your comments, enclose a self-addressed, stamped postcard in
the envelope containing your comments. Upon receiving your comments,
the Docket Management Facility will return the postcard by mail.
How do I submit confidential business information?
If you wish to submit any information under a claim of
confidentiality, you should submit three copies of your complete
submission, including the information you claim to be confidential
business information, to the Chief Counsel's office, NHTSA, at the
address given above under FOR FURTHER INFORMATION CONTACT. In addition,
you should submit two copies, from which you have deleted the claimed
confidential business information, to the Docket Management Facility at
the address given above under ADDRESSES. When you send a comment
containing information claimed to be confidential business information,
you should include a cover letter setting forth the information
specified in our confidential business information regulation. (49 CFR
Part 512.)
Will the agency consider late comments?
We will consider all comments that the docket receives before the
close of business on the comment closing date indicated above under
DATES. To the extent possible, we will also consider comments received
after that date. If the docket receives a comment too late for us to
consider in developing a final rule (assuming that one is issued), we
will consider that comment as an informal suggestion for a future
rulemaking action.
How can I read the comments submitted by other people?
You may read the comments received by the Docket Management
Facility at the address given above under ADDRESSES. The hours of the
Docket are indicated above in the same location. You may also see the
comments on the Internet. To read the comments on the
[[Page 69969]]
Internet, go to https://www.regulations.gov. Follow the online
instructions for accessing the dockets.
Please note that even after the comment closing date, we will
continue to file relevant information in the docket as it becomes
available. Further, some people may submit late comments. Accordingly,
we recommend that you periodically check the docket for new material.
Anyone is able to search the electronic form of all comments
received into any of our dockets by the name of the individual
submitting the comment (or signing the comment, if submitted on behalf
of an association, business, labor union, etc.). You may review DOT's
complete Privacy Act Statement in the Federal Register published on
April 11, 2000 (Volume 65, Number 70; Pages 19477-78).
List of Subjects in 49 CFR Part 572
Motor vehicle safety, Incorporation by reference.
In consideration of the foregoing, NHTSA proposes to amend 49 CFR
Part 572 as follows:
PART 572--ANTHROPOMORPHIC TEST DEVICES
0
1. The authority citation for Part 572 would be amended to read as
follows:
Authority: 49 U.S.C. 322, 30111, 30115, 30117 and 30166;
delegation of authority at 49 CFR 1.95.
0
2. 49 CFR Part 572 would be amended by adding a new Subpart W
consisting of 572.210-572.219 to read as follows:
Subpart W--Q3s Three-Year-Old Child Test Dummy
Secs.
572.210 Incorporation by reference.
572.211 General description.
572.212 Head assembly and test procedure.
572.213 Neck assembly and test procedure.
572.214 Shoulder assembly and test procedure.
572.215 Thorax with arm assembly and test procedure.
572.216 Thorax without arm assembly and test procedure.
572.217 Lumbar spine assembly and test procedure.
572.218 Pelvis assembly and test procedure.
572.219 Test conditions and instrumentation.
Appendix--Figures to Subpart W of Part 572
Sec. 572.210 Incorporation by reference.
(a) Certain material is incorporated by reference (IBR) into this
part with the approval of the Director of the Federal Register under 5
U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that
specified in this section, NHTSA must publish notice of change in the
Federal Register and the material must be available to the public. All
approved material is available for inspection at the Department of
Transportation, Docket Operations, Room W12-140, telephone 202-366-
9826, and is available from the sources listed below. The material is
available in electronic format through Regulations.gov, call 1-877-378-
5457 or go to www.regulations.gov. It is also available for inspection
at the National Archives and Records Administration (NARA). For
information on the availability of this material at NARA, call 202-741-
6030 or go to https://www.archives.gov/federal-register/cfr/ibr-locations.html.
(b) NHTSA Technical Information Services, 1200 New Jersey Ave. SE.,
Washington, DC 20590, telephone 202-366-5965.
(1) A parts/drawing list entitled, ``Parts/Drawings List, Part 572
Subpart W, Q3s Three-Year-Old Child Test Dummy, May 2012,'' IBR
approved for Sec. 572.211.
(2) A drawings and inspection package entitled, ``Parts List and
Drawings, Part 572 Subpart W, Q3s Three-Year-Old Child Test Dummy, May
2012,'' IBR approved for Sec. 572.211, including:
(i) Drawing No. 020-0100, Complete Assembly Q3s, IBR approved for
Sec. Sec. 572.211, 572.212, 572.213, 572.214, 572.215, 572.216,
572.217, 572.218, and 572.219.
(ii) Drawing No. 020-1200, Head Assembly, IBR approved for
Sec. Sec. 572.211, 572.212, 572.214, 572.215, 572.216, 572.218, and
572.219.
(iii) Drawing No. 020-2400, Neck Assembly, IBR approved for
Sec. Sec. 572.211, 572.213, 572.214, 572.215, 572.216, 572.218, and
572.219.
(iv) Drawing No. 020-9050, Headform, IBR approved for Sec. Sec.
572.211, 572.213, 572.217 and 572.219.
(v) Drawing No. DL210-200, Neck Twist Fixture, IBR approved for
Sec. Sec. 572.211, 572.213, and 572.219.
(vi) Drawing No. 020-4500, Torso Assembly, IBR approved for
Sec. Sec. 572.211, 572.214, 572.215, 572.216, 572.218 and 572.219.
(vii) Drawing No. 020-6000, Lumbar Spine Assembly, IBR approved for
Sec. Sec. 572.211, 572.217 and 572.219.
(viii) Drawing No. 020-7500, Pelvis Assembly, IBR approved for
Sec. Sec. 572.211, 572.214, 572.215, 572.216, 572.218, and 572.219.
(ix) Drawing No. 020-8001, Q3s Suit, IBR approved for Sec. Sec.
572.211, 572.214, 572.215, 572.216, 572.218, and 572.219.
(x) Drawing No. 020-9500, Complete Leg Assembly--left, IBR approved
for Sec. Sec. 572.211, 572.214, 572.215, 572.216, 572.218, and 572.219
as part of a complete dummy assembly.
(xi) Drawing No. 020-9600, Complete Leg Assembly--right, IBR
approved for Sec. Sec. 572.211, 572.214, 572.215, 572.216, 572.218,
and 572.219 as part of a complete dummy assembly.
(xii) Drawing No. 020-9700, Complete Arm Assembly--left, IBR
approved for Sec. Sec. 572.211, 572.214, 572.215, 572.216, 572.218,
and 572.219 as part of a complete dummy assembly.
(xiii) Drawing No. 020-9800, Complete Arm Assembly--right, IBR
approved for Sec. Sec. 572.211, 572.214, 572.215, 572.216, 572.218,
and 572.219 as part of a complete dummy assembly.
(3) A procedures manual entitled ``Procedures for Assembly,
Disassembly and Inspection (PADI) of the Q3s Child Side Impact Crash
Test Dummy, September 2013,'' IBR approved for Sec. Sec. 572.211 and
572.219.
(c) SAE International, 400 Commonwealth Drive, Warrendale, PA
15096, call 1-877-606-7323.
(1) SAE Recommended Practice J211, Rev. Mar 95, ``Instrumentation
for Impact Tests--Part 1--Electronic Instrumentation,'' IBR approved
for Sec. 572.219;
(2) SAE Information Report J1733 of 1994-12, ``Sign Convention for
Vehicle Crash Testing,'' IBR approved for Sec. 572.219.
Sec. 572.211 General description.
(a) The Q3s Three-Year-Old Child Test Dummy is defined by drawings
and specifications containing the following materials:
(1) The parts enlisted in ``Parts List and Drawings, Part 572
Subpart W, Q3s Three-Year-Old Child Test Dummy, September 2013''
(incorporated by reference, see Sec. 572.210).
(2) The engineering drawings and specifications contained in
``Parts List and Drawings, Part 572 Subpart W, Q3s Three-Year-Old Child
Test Dummy, September 2013,'' which includes the engineering drawings
and specifications described in Drawing 020-0000, the titles of which
are listed in Table A, and,
(3) A manual entitled ``Procedures for Assembly, Disassembly and
Inspection (PADI) of the Q3s Child Side Impact Crash Test Dummy,
September 2013.''
Table A to Sec. 572.211
------------------------------------------------------------------------
Component assembly Drawing number
------------------------------------------------------------------------
(i) Head Assembly...................... 020-1200
(ii) Neck Assembly..................... 020-2400
(iii) Torso Assembly................... 020-4500
(iv) Lumbar Spine Assembly............. 020-6000
(v) Pelvis Assembly.................... 020-7500
[[Page 69970]]
(vi) Complete Leg Assembly--left....... 020-9500
(vii) Complete Leg Assembly--right..... 020-9600
(viii) Complete Arm Assembly--left..... 020-9700
(ix) Complete Arm Assembly--right...... 020-9800
------------------------------------------------------------------------
(b) The structural properties of the dummy are such that the dummy
conforms to this Subpart in every respect before use in any test.
Sec. 572.212 Head assembly and test procedure.
(a) The head assembly for this test consists of the complete head
(drawing 020-1200) with head accelerometer assembly (drawing 020-
1013A), and a half mass simulated upper neck load cell (drawing 020-
1050) (all incorporated by reference, see Sec. 572.210).
(b) When the head assembly is tested according to the test
procedure in paragraph (c) of this section, it shall have the following
characteristics:
(1) Frontal head qualification test. When the head assembly is
dropped from a height of 376.0 1.0 mm (14.8
0.04 in) in accordance with subsection (c) of this section, the peak
resultant acceleration at the location of the accelerometers at the
head CG shall have a value between 250 G and 297 G. The resultant
acceleration vs. time history curve shall be unimodal; oscillations
occurring after the main pulse must be less than 10 percent of the peak
resultant acceleration. The lateral acceleration shall not exceed 15 G
(zero to peak).
(2) Lateral head qualification test. When the head assembly is
dropped from a height of 200.0 1.0 mm (7.87
0.04 in) in accordance with subsection (c) of this section, the peak
resultant acceleration at the location of the accelerometers at the
head CG shall have a value between 113 G and 140 G. The resultant
acceleration vs. time history curve shall be unimodal; oscillations
occurring after the main pulse must be less than 10 percent of the peak
resultant acceleration. The X-component acceleration shall not exceed
20 G (zero to peak).
(c) Test procedure: The test procedure for the head assembly is as
follows:
(1) Soak the head assembly in a controlled environment at any
temperature between 18.9 and 25.6 [deg]C (66 and 78 [deg]F) and a
relative humidity from 10 to 70 percent for at least four hours prior
to a test.
(2) Prior to the test, clean the impact surface of the skin and the
impact plate surface with isopropyl alcohol, trichloroethane, or an
equivalent. The skin of the head and the impact plate surface must be
clean and dry for testing.
(3)(i) For the frontal head test, suspend and orient the head
assembly with the forehead facing the impact surface as shown in Figure
W1. The lowest point on the forehead must be 376.0 1.0 mm
(14.8 0.04 in) from the impact surface. Assure that the
head is horizontal laterally. Adjust the head angle so that the upper
neck load cell simulator is 28 2 degrees forward from the
vertical while assuring that the head remains horizontal laterally.
(ii) For the lateral head test, the head is dropped on the aspect
that opposes the primary load vector of the ensuing full scale test for
which the dummy is being qualified. A left drop set up that is used to
qualify the dummy for an ensuing full scale left side impact is
depicted in Figure W2. A right drop set-up would be the mirror image of
that shown in Figure W2. Suspend and orient the head assembly as shown
in Figure W2. The lowest point on the impact side of the head must be
200.0 1.0 mm (7.87 0.04 in) from the impact
surface. Assure that the head is horizontal in the fore-aft direction.
Adjust the head angle so that the head base plane measured from the
base surface of the upper neck load cell simulator is 35 2
degrees forward from the vertical while assuring that the head remains
horizontal in the fore-aft direction.
(4) Drop the head assembly from the specified height by means that
ensure a smooth, instant release onto a rigidly supported flat
horizontal steel plate which is 50.8 mm (2 in) thick and 610 mm (24 in)
square. The impact surface shall be clean, dry and have a micro finish
of not less than 203.2 x 10-6 mm (8 micro inches) (RMS) and
not more than 2,032.0 x 10-6 mm (80 micro inches) (RMS).
(5) Allow at least 2 hours between successive tests on the same
head.
Sec. 572.213 Neck assembly and test procedure.
(a)(1) The neck and headform assembly (refer to Sec.
572.210(b)(2)(iii) and Sec. 572.210(b)(2)(iv)) for the purposes of the
fore-aft neck flexion and lateral neck flexion qualification tests, as
shown in Figures W3 and W4, consists of the headform (drawing 020-9050,
sheet 1) with angular rate sensor installed (drawing SA572-S58), six-
channel neck/lumbar load cell (drawing SA572-S8), neck assembly
(drawing 020-2400), neck/torso interface plate (drawing 020-9056) and
pendulum interface plate (drawing 020-9051) with angular rate sensor
installed (drawing SA572-S58) (all incorporated by reference, see Sec.
572.210).
(2) The neck assembly (refer to Sec. 572.210(b)(2)(iii) and Sec.
572.210(b)(2)(v)) for the purposes of the neck torsion qualification
test, as shown in Figure W5, consists of the neck twist fixture
(drawing DL210-200) with rotary potentiometer installed (drawing SA572-
S51), neck adaptor plate assembly (drawing DL210-220), neck assembly
(drawing 020-2400), six-channel neck/lumbar load cell (drawing SA572-
S8), and twist fixture end plate (drawing DL210-210) (all incorporated
by reference, see Sec. 572.210).
(b) When the neck and headform assembly as defined in Sec.
572.213(a)(1), or the neck assembly as defined in Sec. 572.213(a)(2),
is tested according to the test procedure in paragraph (c) of this
section, it shall have the following characteristics:
(1) Fore-aft neck flexion qualification test.
(i) Plane D, referenced in Figure W3, shall rotate in the direction
of pre-impact flight with respect to the pendulum's longitudinal
centerline between 70 degrees and 82 degrees, which shall occur between
55 and 63 ms from time zero. The peak moment, measured by the neck
transducer (drawing SA572-S8) (incorporated by reference, see Sec.
572.210) shall have a value between 41 N-m (30.2 ft-lbf) and 51 N-m
(37.6 ft-lbf) occurring between 49 and 62 ms from time zero.
(ii) The decaying headform rotation vs. time curve shall cross the
zero angle with respect to its initial position at time of impact
relative to the pendulum centerline between 50 to 54 ms after the time
the peak rotation value is reached.
(iii) All instrumentation data channels are defined to be zero when
the longitudinal centerline of the neck and pendulum are parallel.
(iv) The headform rotation shall be calculated by the following
formula with the integration beginning at time zero:
Headform rotation (deg) = [int] [(Headform Angular Rate)y-
(Pendulum Angular Rate)y] dt
(v) (Headform Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the headform (drawing 020-9050, sheet
1), and (Pendulum Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the pendulum interface plate (drawing
020-9051) (incorporated by reference, see Sec. 572.210).
[[Page 69971]]
(2) Lateral neck flexion qualification test.
(i) Plane D, referenced in Figure W4, shall rotate in the direction
of pre-impact flight with respect to the pendulum's longitudinal
centerline between 77 degrees and 88 degrees, which shall occur between
65 and 72 ms from time zero. The peak moment, measured by the neck
transducer (drawing SA572-S8) (incorporated by reference, see Sec.
572.210) shall have a value between 25 N-m (18.4 ft-lbf) and 32 N-m
(23.6 ft-lbf) occurring between 66 and 73 ms from time zero.
(ii) The decaying headform rotation vs. time curve shall cross the
zero angle with respect to its initial position at time of impact
relative to the pendulum centerline between 63 to 69 ms after the time
the peak rotation value is reached.
(iii) All instrumentation data channels are defined to be zero when
the longitudinal centerline of the neck and pendulum are parallel.
(iv) The headform rotation shall be calculated by the following
formula with the integration beginning at time zero:
Headform rotation (deg) = [int] [(Headform Angular Rate)y-
(Pendulum Angular Rate)y] dt
(v) (Headform Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the headform (drawing 020-9050, sheet
1), and (Pendulum Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the pendulum interface plate (drawing
020-9051) (incorporated by reference, see Sec. 572.210).
(3) Neck torsion qualification test.
(i) The neck twist fixture (drawing DL210-200), referenced in
Figure W5, shall rotate in the direction of pre-impact flight with
respect to the pendulum's longitudinal centerline between 75 degrees
and 93 degrees, as measured by the rotary potentiometer (drawing SA572-
S51), and shall occur between 91 and 113 ms from time zero. The peak
moment, measured by the neck transducer (drawing SA572-S8) shall have a
value between 8 N-m (5.9 ft-lbf) and 10 N-m (7.4 ft-lbf) occurring
between 85 and 105 ms from time zero) (all incorporated by reference,
see Sec. 572.210).
(ii) The decaying neck twist fixture rotation vs. time curve shall
cross the zero angle with respect to its initial position at time of
impact relative to the pendulum centerline between 84 to 103 ms after
the time the peak rotation value is reached.
(iii) All instrumentation data channels are defined to be zero when
the zero pins are installed such that the neck is not in torsion.
(iv) Time zero is defined as the time of initial contact between
the pendulum striker plate and the honeycomb material. All data
channels shall be at the zero level at this time.
(c) Test procedure: The test procedure for the neck assembly is as
follows:
(1) Soak the neck assembly in a controlled environment at any
temperature between 20.6 and 22.2 [deg]C (69 and 72 [deg]F) and a
relative humidity between 10 and 70 percent for at least four hours
prior to a test.
(2)(i) For the fore-aft neck flexion test, mount the neck and
headform assembly, defined in subsection (a)(1) of this section, on the
pendulum described in Figure 22 of 49 CFR 572 so that the midsagittal
plane of the headform is vertical and coincides with the plane of
motion of the pendulum, and with the neck placement such that the front
side of the neck is closest to the honeycomb material.
(ii) For the lateral neck flexion test, the test is carried out in
the direction opposing the primary load vector of the ensuing full
scale test for which the dummy is being qualified. A right flexion test
set-up that is used to qualify the dummy for an ensuing full scale
right side impact is depicted in Figure W4. A left flexion test set-up
would be a mirror image of that shown in Figure W4. Mount the neck and
headform assembly, defined in subsection (a)(1) of this section, on the
pendulum described in Figure 22 of 49 CFR 572 so that the midsagittal
plane of the headform is vertical and coincides with the plane of
motion of the pendulum, and with the neck placement such that the right
(or left) side of the neck is closest to the honeycomb material.
(iii) For the neck torsion test, the test is carried out in the
direction opposing the primary load vector of the ensuing full scale
test for which the dummy is being qualified. A right torsion test set-
up that is used to qualify the dummy for an ensuing full scale right
side impact is depicted in Figure W5. A left flexion test set-up would
be a mirror image of that shown in Figure W5. Mount the neck assembly,
defined in subsection (a)(2) of this section, on the pendulum described
in Figure 22 of 49 CFR 572, as shown in Figure W5 of this subpart.
(3)(i) Release the pendulum and allow it to fall freely from a
height to achieve an impact velocity of 4.7 0.1 m/s (15.6
0.3 ft/s) for fore-aft flexion, 3.8 0.05 m/s
(12.5 0.2 ft/s) for lateral flexion, and 3.6
0.1 m/s (11.8 0.3 ft/s) for torsion, measured by an
accelerometer mounted on the pendulum as shown in Figure 22 of this
Part 572 at time zero.
(ii) Stop the pendulum from the initial velocity with an
acceleration vs. time pulse that meets the velocity change as specified
in Table B of this section. Integrate the pendulum accelerometer data
channel to obtain the velocity vs. time curve beginning at time zero.
Table B to Sec. 572.213
----------------------------------------------------------------------------------------------------------------
Fore-aft flexion Lateral flexion Torsion
Time ---------------------------- Time ---------------------------- Time ---------------------------
(ms) m/s ft/s (ms) m/s ft/s (ms) m/s ft/s
----------------------------------------------------------------------------------------------------------------
10 1.1-2.1 3.6-6.9 10 1.7-2.2 5.6-7.2 10 0.9-1.3 3.0-4.3
20 2.8-3.8 9.2-12.5 15 2.5-3.0 8.2-9.8 15 1.4-2.0 4.6-6.6
30 4.1-5.1 13.5-16.7 20 3.4-3.9 11.2-12.8 20 2.0-2.6 6.6-8.5
----------------------------------------------------------------------------------------------------------------
Sec. 572.214 Shoulder assembly and test procedure.
(a) The shoulder assembly for this test consists of the torso
assembly (drawing 020-4500) with string pot assembly (drawing SA572-S38
or SA572-S39) installed (incorporated by reference, see Sec. 572.210).
(b) When the center of the shoulder of a completely assembled dummy
(drawing 020-0100) (incorporated by reference, see Sec. 572.210) is
impacted laterally by a test probe conforming to Sec. 572.219, at 3.6
0.1 m/s (11.8 0.3 ft/s) according to the test
procedure in paragraph (c) of this section:
(1) Maximum lateral shoulder displacement (compression) relative to
the spine, measured with the string pot assembly (drawing SA572-S38 or
SA572-S39) (incorporated by reference, see Sec. 572.210), must not be
less than 16 mm (0.63 in) and not more than 21 mm (0.83 in). The peak
force, measured by the impact probe as defined in Sec. 572.219
[[Page 69972]]
and calculated in accordance with paragraph (b)(2) of this section,
shall have a value between 1.24 kN (279 lbf) and 1.35 kN (303 lbf).
(2) The force shall be calculated by the product of the impactor
mass and its measured deceleration.
(c) Test procedure: The test procedure for the shoulder assembly is
as follows:
(1) The dummy is clothed in the Q3s suit (drawing 020-8001)
(incorporated by reference, see Sec. 572.210). No additional clothing
or shoes are placed on the dummy.
(2) Soak the dummy in a controlled environment at any temperature
between 20.6 and 22.2 [ordm]C (69 and 72 [ordm]F) and a relative
humidity from 10 to 70 percent for at least four hours prior to a test.
(3) The shoulder test is carried out in the direction opposing the
primary load vector of the ensuing full scale test for which the dummy
is being qualified. A left shoulder test set-up that is used to qualify
the dummy for an ensuing full scale left side impact is depicted in
Figure W6. A right shoulder set-up would be a mirror image of that
shown in Figure W6. Seat the dummy on the qualification bench described
in Figure V3 of 49 CFR 572.194, the seat pan and seat back surfaces of
which are covered with thin sheets of PTFE (Teflon) (nominal stock
thickness: 2 to 3 mm) (3/32- to 1/8-inch) along the impact side of the
bench.
(4) Position the dummy on the bench as shown in Figure W6, with the
ribs making contact with the seat back oriented 24.6 degrees relative
to vertical, the legs extended forward along the seat pan oriented 21.6
degrees relative to horizontal with the knees spaced 40 mm (1.57 in)
apart, and the arms positioned so that the upper arms are parallel to
the seat back ( 2 degrees) and the lower arms are
perpendicular to the upper arms.
(5) The target point of the impact is a point on the shoulder that
is 15 mm above and perpendicular to the midpoint of a line connecting
the centers of the bolt heads of the two lower bolts (part
5000010) that connect the upper arm assembly (020-9750) to the
shoulder ball retaining ring (020-3533).
(6) Impact the shoulder with the test probe so that at the moment
of contact the probe's longitudinal centerline should be horizontal
( 1 degrees), and the centerline of the probe should be
within 2 mm (0.08 in) of the target point.
(7) Guide the test probe during impact so that there is no
significant lateral, vertical, or rotational movement.
(8) No suspension hardware, suspension cables, or any other
attachments to the probe, including the velocity vane, shall make
contact with the dummy during the test.
Sec. 572.215 Thorax with arm assembly and test procedure.
(a) The thorax assembly for this test consists of the torso
assembly (drawing 020-4500) with IR-TRACC (drawing SA572-S37)
(incorporated by reference, see Sec. 572.210) installed.
(b) When the thorax of a completely assembled dummy (drawing 020-
0100) (incorporated by reference, see Sec. 572.210) is impacted
laterally by a test probe conforming to Sec. 572.219 at 5.0 0.1 m/s (16.4 0.3 ft/s) according to the test
procedure in paragraph (c) of this section:
(1) Maximum lateral thorax displacement (compression) relative to
the spine, measured with the IR-TRACC (drawing SA572-S37) and processed
as set out in the PADI (all incorporated by reference, see Sec.
572.210), shall have a value between 23 mm (0.91 in) and 28 mm (1.10
in). The peak force occurring after 5 ms, measured by the impact probe
as defined in Sec. 572.219 and calculated in accordance with paragraph
(b)(2) of this section, shall have a value between 1.38 kN (310 lbf)
and 1.69 kN (380 lbf).
(2) The force shall be calculated by the product of the impactor
mass and its measured deceleration.
(3) Time zero is defined as the time of contact between the impact
probe and the arm. All channels should be at a zero level at this
point.
(c) Test procedure: The test procedure for the thorax with arm
assembly is as follows:
(1) The dummy is clothed in the Q3s suit (drawing 020-8001)
(incorporated by reference, see Sec. 572.210). No additional clothing
or shoes are placed on the dummy.
(2) Soak the dummy in a controlled environment at any temperature
between 20.6 and 22.2 [ordm]C (69 and 72 [ordm]F) and a relative
humidity from 10 to 70 percent for at least four hours prior to a test.
(3) The test is carried out in the direction opposing the primary
load vector of the ensuing full scale test for which the dummy is being
qualified. A left thorax test set-up that is used to qualify the dummy
for an ensuing full scale left side impact is depicted in Figure W7. A
right thorax set-up would be a mirror image of that shown in Figure W7.
Seat the dummy on the qualification bench described in Figure V3 of 49
CFR 572.194, the seat pan and seat back surfaces of which are covered
with thin sheets of PTFE (Teflon) (nominal stock thickness: 2 to 3 mm
(3/32- to 1/8-inch)) along the impact side of the bench.
(4) Position the dummy on the bench as shown in Figure W7, with the
ribs making contact with the seat back oriented 24.6 degrees relative
to vertical, the legs extended forward along the seat pan oriented 21.6
degrees relative to horizontal with the knees spaced 40 mm (1.57 in)
apart. On the non-impact side of the dummy, the long axis of the upper
arm is positioned parallel to the seat back ( 2 degrees).
On the impact side, the upper arm is positioned such that the target
point intersects its long axis as described in (5) below. The long axis
of the upper arm is defined by section line A-A in drawing 020-9750
(incorporated by reference, see Sec. 572.210). Both of the lower arms
are set perpendicular to the upper arms.
(5) The target point of the impact is the point of intersection on
the lateral aspect of the upper arm and a line projecting from the
thorax of the dummy. The projecting line is horizontal, runs parallel
to the coronal plane of the dummy, and passes through the midpoint of a
line connecting the centers of the bolt heads of the two IR-TRACC bolts
(part 5000646). The projected line should intersect the upper
arm within 2 mm (0.80 in) of its long axis.
(6) Impact the arm with the test probe so that at the moment of
contact the probe's longitudinal centerline should be horizontal
( 1 degrees), and the centerline of the probe should be
within 2 mm (0.80 in) of the target point.
(7) Guide the test probe during impact so that there is no
significant lateral, vertical, or rotational movement.
(8) No suspension hardware, suspension cables, or any other
attachments to the probe, including the velocity vane, shall make
contact with the dummy during the test.
Sec. 572.216 Thorax without arm assembly and test procedure.
(a) The thorax assembly for this test consists of the torso
assembly (drawing 020-4500) with IR-TRACC (drawing SA572-S37)
(incorporated by reference, see Sec. 572.210) installed.
(b) When the thorax of a completely assembled dummy (drawing 020-
0100) with the arm (drawing 020-9700 or 020-9800) on the impacted side
removed is impacted laterally by a test probe conforming to Sec.
572.219 at 3.3 0.1 m/s (10.8 0.3 ft/s)
according to the test procedure in paragraph (c) of this section:
(1) Maximum lateral thorax displacement (compression) relative to
[[Page 69973]]
the spine, measured with the IR-TRACC (drawing SA572-S37) and processed
as set out in the PADI (all incorporated by reference, see Sec.
572.210), shall have a value between 24 mm (0.94 in) and 31 mm (1.22
in). The peak force, measured by the impact probe as defined in Sec.
572.219 and calculated in accordance with paragraph (b)(2) of this
section, shall have a value between 620 N (139 lbf) and 770 N (173
lbf).
(2) The force shall be calculated by the product of the impactor
mass and its measured deceleration.
(c) Test procedure: The test procedure for the thorax without arm
assembly is as follows:
(1) The dummy is clothed in the Q3s suit (drawing 020-8001)
(incorporated by reference, see Sec. 572.210). No additional clothing
or shoes are placed on the dummy.
(2) Soak the dummy in a controlled environment at any temperature
between 20.6 and 22.2 [deg]C (69 and 72 [deg]F) and a relative humidity
from 10 to 70 percent for at least four hours prior to a test.
(3) The test is carried out in the direction opposing the primary
load vector of the ensuing full scale test for which the dummy is being
qualified. A left thorax test set-up that is used to qualify the dummy
for an ensuing full scale left side impact is depicted in Figure W8. A
right thorax set-up would be a mirror image of that shown in Figure W8.
Seat the dummy on the qualification bench described in Figure V3 of 49
CFR 572.194, the seat pan and seat back surfaces of which are covered
with thin sheets of PTFE (Teflon) (nominal stock thickness: 2 to 3 mm
(\3/32\- to \1/8\-inch)) along the impact side of the bench.
(4) Position the dummy on the bench as shown in Figure W8, with the
ribs making contact with the seat back oriented 24.6 degrees relative
to vertical, the legs extended forward along the seat pan oriented 21.6
degrees relative to horizontal with the knees spaced 40 mm (1.57 in)
apart, and the arm on the non-impacted side positioned so that the
upper arm is parallel ( 2 degrees) to the seat back and the
lower arm perpendicular to the upper arm.
(5) The target point of the impact is the midpoint of a line
between the centers of the bolt heads of the two IR-TRACC bolts (part
5000646).
(6) Impact the thorax with the test probe so that at the moment of
contact the probe's longitudinal centerline should be horizontal
( 1 degrees), and the centerline of the probe should be
within 2 mm (0.08 in) of the target point.
(7) Guide the test probe during impact so that there is no
significant lateral, vertical, or rotational movement.
(8) No suspension hardware, suspension cables, or any other
attachments to the probe, including the velocity vane, shall make
contact with the dummy during the test.
Sec. 572.217 Lumbar spine assembly and test procedure.
(a) The lumbar spine and headform assembly (refer to Sec.
572.210(b)(2)(iv) and Sec. 572.210(a)(2)(vii)) for the purposes of the
fore-aft lumbar flexion and lateral lumbar flexion qualification tests,
as shown in Figures W9 and W10, consists of the headform (drawing 020-
9050, sheet 2) with angular rate sensor installed (drawing SA572-S58),
six-channel neck/lumbar load cell (drawing SA572-S8), lumbar spine
assembly (drawing 020-6000), lumbar interface plate (drawing 020-9062)
and pendulum interface plate (drawing 020-9051) with angular rate
sensor installed (drawing SA572-S58) (all incorporated by reference,
see Sec. 572.210).
(b) When the lumbar spine and headform assembly is tested according
to the test procedure in paragraph (c) of this section, it shall have
the following characteristics:
(1) Fore-aft lumbar flexion qualification test.
(i) Plane D, referenced in Figure W9, shall rotate in the direction
of pre-impact flight with respect to the pendulum's longitudinal
centerline between 48 degrees and 57 degrees, which shall occur between
52 and 59 ms from time zero. The peak moment, measured by the neck/
lumbar transducer (drawing SA572-S8) (incorporated by reference, see
Sec. 572.210) shall have a value between 78 N-m (57.5 ft-lbf) and 94
N-m (69.3 ft-lbf) occurring between 46 and 57 ms from time zero.
(ii) The decaying headform rotation vs. time curve shall cross the
zero angle with respect to its initial position at time of impact
relative to the pendulum centerline between 50 to 56 ms after the time
the peak rotation value is reached.
(iii) All instrumentation data channels are defined to be zero when
the longitudinal centerline of the lumbar spine and pendulum are
parallel.
(iv) The headform rotation shall be calculated by the following
formula with the integration beginning at time zero:
Headform rotation (deg) = [int] [(Headform Angular Rate)y -
(Pendulum Angular Rate)y] dt
(v) (Headform Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the headform (drawing 020-9050, sheet
2), and (Pendulum Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the pendulum interface plate (drawing
020-9051) (all incorporated by reference, see Sec. 572.210).
(2) Lateral lumbar flexion qualification test.
(i) Plane D, referenced in Figure W10, shall rotate in the
direction of pre-impact flight with respect to the pendulum's
longitudinal centerline between 47 degrees and 59 degrees, which shall
occur between 50 and 59 ms from time zero. The peak moment, measured by
the neck/lumbar transducer (drawing SA572-S8) (incorporated by
reference, see Sec. 572.210) shall have a value between 78 N-m (57.5
ft-lbf) and 97 N-m (71.5 ft-lbf) occurring between 46 and 57 ms from
time zero.
(ii) The decaying headform rotation vs. time curve shall cross the
zero angle with respect to its initial position at time of impact
relative to the pendulum centerline between 47 to 59 ms after the time
the peak rotation value is reached.
(iii) All instrumentation data channels are defined to be zero when
the longitudinal centerline of the lumbar spine and pendulum are
parallel.
(iv) The headform rotation shall be calculated by the following
formula with the integration beginning at time zero:
Headform rotation (deg) = [int] [(Headform Angular Rate)y-
(Pendulum Angular Rate)y] dt
(v) (Headform Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the headform (drawing 020-9050, sheet
2), and (Pendulum Angular Rate)y is the angular rate about
the y-axis in deg/sec measured on the pendulum interface plate (drawing
020-9051) (all incorporated by reference, see Sec. 572.210).
(c) Test procedure: The test procedure for the lumbar spine
assembly is as follows:
(1) Soak the lumbar spine assembly in a controlled environment at
any temperature between 20.6 and 22.2 [deg]C (69 and 72 [deg]F) and a
relative humidity between 10 and 70 percent for at least four hours
prior to a test.
(2)(i) For the fore-aft lumbar flexion test, mount the lumbar spine
and headform assembly, defined in subsection (a) of this section, on
the pendulum described in Figure 22 of 49 CFR 572 so that the
midsagittal plane of the headform is vertical and coincides with the
plane of motion of the pendulum, and with the lumbar spine placement
such that the front side of the lumbar spine is closest to the
honeycomb material.
[[Page 69974]]
(ii) For the lateral lumbar flexion test, the test is carried out
in the direction opposing the primary load vector of the ensuing full
scale test for which the dummy is being qualified. A right flexion test
set-up that is used to qualify the dummy for an ensuing a full scale
right side impact is depicted in Figure W10. A left flexion test set-up
would be a mirror image of that shown in Figure W10. Mount the lumbar
spine and headform assembly, defined in subsection (a)(1) of this
section, on the pendulum described in Figure 22 of 49 CFR 572 so that
the midsagittal plane of the headform is vertical and coincides with
the plane of motion of the pendulum, and with the lumbar spine
placement such that the right (or left) side of the lumbar spine is
closest to the honeycomb material.
(3)(i) Release the pendulum and allow it to fall freely from a
height to achieve an impact velocity of 4.4 0.1 m/s (14.4
0.3 ft/s), measured by an accelerometer mounted on the
pendulum as shown in Figure 22 of this Part 572 at time zero.
(ii) Stop the pendulum from the initial velocity with an
acceleration vs. time pulse that meets the velocity change as specified
in Table C of this section. Integrate the pendulum accelerometer data
channel to obtain the velocity vs. time curve beginning at time zero.
Table C to Sec. 572.217
----------------------------------------------------------------------------------------------------------------
Fore-aft flexion Lateral flexion
Time (ms) ---------------------------------------------------
m/s ft/s m/s ft/s
----------------------------------------------------------------------------------------------------------------
10.......................................................... 1.3-1.7 4.3-5.6 1.3-1.7 4.3-5.6
20.......................................................... 2.7-3.7 8.9-12.1 2.7-3.7 8.9-12.1
30.......................................................... 4.1-4.9 13.5-16.1 4.0-4.8 13.1-15.7
----------------------------------------------------------------------------------------------------------------
Sec. 572.218 Pelvis assembly and test procedure.
(a) The pelvis assembly (drawing 020-7500) for this test includes a
uniaxial pubic load cell (drawing SA572-S7) installed on the non-impact
side of the pelvis (all incorporated by reference, see Sec. 572.210).
(b) When the center of the pelvis of a completely assembled dummy
(drawing 020-0100) (incorporated by reference, see Sec. 572.210) is
impacted laterally by a test probe conforming to Sec. 572.219 at 4.0
0.1 m/s (13.1 0.3 ft/s) according to the test
procedure in paragraph (c) of this section:
(1) Maximum pubic load, measured with the uniaxial pubic load cell
(drawing SA572-S7) (incorporated by reference, see Sec. 572.210),
shall have a value between 700 N (157 lbf) and 870 N (196 lbf). The
peak force, measured by the impact probe as defined in Sec. 572.219
and calculated in accordance with paragraph (b)(2) of this section,
shall have a value between 1.57 kN (353 lbf) and 1.81 kN (407 lbf).
(2) The force shall be calculated by the product of the impactor
mass and its measured deceleration.
(c) Test procedure: The test procedure for the pelvis assembly is
as follows:
(1) The dummy is clothed in the Q3s suit (drawing 020-8001)
(incorporated by reference, see Sec. 572.210). No additional clothing
or shoes are placed on the dummy.
(2) Soak the dummy in a controlled environment at any temperature
between 20.6 and 22.2 [deg]C (69 and 72 [deg]F) and a relative humidity
from 10 to 70 percent for at least four hours prior to a test.
(3) The pelvis test is carried out in the direction opposing the
primary load vector of the ensuing full scale test for which the dummy
is being qualified. A left pelvis test set-up that is used to qualify
the dummy for an ensuing full scale left side impact is depicted in
Figure W11. A right pelvis test set-up would be a mirror image of that
shown in Figure W11. Seat the dummy on the qualification bench
described in Figure V3 of 49 CFR 572.194, the seat pan and seat back
surfaces of which are covered with thin sheets of PTFE (Teflon)
(nominal stock thickness: 2 to 3 mm (\3/32\- to \1/8\-inch)) along the
impact side of the bench.
(4) Position the dummy on the bench as shown in Figure W11, with
the ribs making contact with the seat back oriented 24.6 degrees
relative to vertical, the legs extended forward along the seat pan
oriented 21.6 degrees relative to horizontal with the knees spaced 40
mm (1.57 in) apart. The arms should be positioned so that the arm on
the non-impacted side is parallel to the seat back with the lower arm
perpendicular to the upper arm, and the arm on the impacted side is
positioned upwards away from the pelvis.
(5) Establish the impact point at the center of the pelvis so that
the impact point of the longitudinal centerline of the probe is located
185 mm (7.28 in) from the center of the knee pivot screw (part
020-9008) and centered vertically on the femur.
(6) Impact the pelvis with the test probe so that at the moment of
contact the probe's longitudinal centerline should be horizontal
( 1 degrees), and the centerline of the probe should be
within 2 mm (0.08 in) of the center of the pelvis.
(7) Guide the test probe during impact so that there is no
significant lateral, vertical, or rotational movement.
(8) No suspension hardware, suspension cables, or any other
attachments to the probe, including the velocity vane, shall make
contact with the dummy during the test.
Sec. 572.219 Test conditions and instrumentation.
(a) The following test equipment and instrumentation is needed for
qualification as set forth in this subpart:
(1) The test probe for shoulder, thorax, and pelvis impacts is of
rigid metallic construction, concentric in shape, and symmetric about
its longitudinal axis. It has a mass of 3.81 0.02 kg (8.40
0.04 lb) and a minimum mass moment of inertia of 560 kg-
cm\2\ (0.407 lbf-in-sec\2\) in yaw and pitch about the CG. One-third
(\1/3\) of the weight of the suspension cables and their attachments to
the impact probe is included in the calculation of mass, and such
components may not exceed five percent of the total weight of the test
probe. The impacting end of the probe, perpendicular to and concentric
with the longitudinal axis, is at least 25.4 mm (1.0 in) long, and has
a flat, continuous, and non-deformable 70.0 0.25 mm (2.76
0.01 in) diameter face with an edge radius between 6.4-
12.7 mm (0.25 to 0.5 in). The probe's end opposite to the impact face
has provisions for mounting of an accelerometer with its sensitive axis
collinear with the longitudinal axis of the probe. No concentric
portions of the impact probe may exceed the diameter of the impact
face. The impact probe shall have a free air resonant frequency of not
less than 1000 Hz, which may be determined using the procedure listed
in the PADI.
(2) Head accelerometers have dimensions, response characteristics,
[[Page 69975]]
and sensitive mass locations specified in drawing SA572-S4 and are
mounted in the head as shown in drawing 020-0100, sheet 2 of 5
(incorporated by reference, see Sec. 572.210).
(3) The upper neck force and moment transducer has the dimensions,
response characteristics, and sensitive axis locations specified in
drawing SA572-S8 and is mounted in the head-neck assembly as shown in
drawing 020-0100, sheet 2 of 5 (incorporated by reference, see Sec.
572.210).
(4) The angular rate sensors for the fore-aft neck flexion and
lateral neck flexion qualification tests have the dimensions and
response characteristics specified in drawing SA572-S58 (incorporated
by reference, see Sec. 572.210) and are mounted in the headform and on
the pendulum as shown in Figures W3, W4 of this subpart.
(5) The string pot shoulder deflection transducers have the
dimensions and response characteristics specified in drawing SA572-S38
or SA572-S39 and are mounted to the torso assembly as shown in drawing
020-0100, sheet 2 of 5 (all incorporated by reference, see Sec.
572.210).
(6) The IR-TRACC thorax deflection transducers have the dimensions
and response characteristics specified in drawing SA572-S37 and are
mounted to the torso assembly as shown in drawing 020-0100, sheet 2 of
5 (incorporated by reference, see Sec. 572.210).
(7) The lumbar spine force and moment transducer has the
dimensions, response characteristics, and sensitive axis locations
specified in drawing SA572-S8 and is mounted in the torso assembly as
shown in drawing 020-0100, sheet 2 of 5 (incorporated by reference, see
Sec. 572.210).
(8) The angular rate sensors for the fore-aft lumbar flexion and
lateral lumbar flexion qualification tests have the dimensions and
response characteristics specified in drawing SA572-S58 (incorporated
by reference, see Sec. 572.210) and are mounted in the headform and on
the pendulum as shown in Figures W9, W10 of this subpart.
(9) The pubic force transducers have the dimensions and response
characteristics specified in drawing SA572-S7 and are mounted in the
torso assembly as shown in drawing 020-0100, sheet 2 of 5 (incorporated
by reference, see Sec. 572.210).
(b) The following instrumentation may be required for installation
in the dummy for compliance testing. If so, it is installed during
qualification procedures as described in this subpart:
(1) The optional angular rate sensors for the head have the
dimensions and response characteristics specified in any of drawings
SA572-S55, SA572-S56, SA572-S57 or SA572-S58 and are mounted in the
head as shown in drawing 020-0100, sheet 2 of 5 (all incorporated by
reference, see Sec. 572.210).
(2) The upper spine accelerometers have the dimensions, response
characteristics, and sensitive mass locations specified in drawing
SA572-S4 and are mounted in the torso assembly as shown in drawing 020-
0100, sheet 2 of 5 (all incorporated by reference, see Sec. 572.210).
(3) The pelvis accelerometers have the dimensions, response
characteristics, and sensitive mass locations specified in drawing
SA572-S4 and are mounted in the torso assembly as shown in drawing 020-
0100, sheet 2 of 5 (all incorporated by reference, see Sec. 572.210).
(4) The T1 accelerometer has the dimensions, response
characteristics, and sensitive mass location specified in drawing
SA572-S4 and is mounted in the torso assembly as shown in drawing 020-
0100, sheet 2 of 5 (incorporated by reference, see Sec. 572.210).
(5) The lower neck force and moment transducer has the dimensions,
response characteristics, and sensitive axis locations specified in
drawing SA572-S8 and is mounted to the neck assembly as shown in
drawing 020-0100, sheet 2 of 5 (incorporated by reference, see Sec.
572.210).
(6) The tilt sensor has the dimensions and response characteristics
specified in drawing SA572-S44 and is mounted to the torso assembly as
shown in drawing 020-0100, sheet 2 of 5 (incorporated by reference, see
Sec. 572.210).
(c) The outputs of transducers installed in the dummy and in the
test equipment specified by this part are to be recorded in individual
data channels that conform to SAE Recommended Practice J211
(incorporated by reference, see Sec. 572.210) except as noted, with
channel frequency classes as follows:
(1) Pendulum acceleration, CFC 180,
(2) Pendulum angular rate, CFC 60,
(3) Neck twist fixture rotation, CFC 60,
(4) Test probe acceleration, CFC 180,
(5) Head accelerations, CFC 1000,
(6) Headform angular rate, CFC 60,
(7) Neck moments, upper and lower, CFC 600,
(7) Shoulder deflection, CFC 180,
(8) Thorax deflection, CFC 180,
(9) Upper spine accelerations, CFC 180,
(10) T1 acceleration, CFC 180,
(11) Pubic force, CFC 180,
(12) Pelvis accelerations, CFC 1000.
(d) Coordinate signs for instrumentation polarity are to conform to
SAE Information Report J1733 (incorporated by reference, see Sec.
572.210).
(e) The mountings for sensing devices have no resonant frequency
less than 3 times the frequency range of the applicable channel class.
(f) Limb joints are set at one G, barely restraining the weight of
the limb when it is extended horizontally. The force needed to move a
limb segment is not to exceed 2G throughout the range of limb motion.
(g) Performance tests of the same component, segment, assembly, or
fully assembled dummy are separated in time by not less than 30 minutes
unless otherwise noted.
(h) Surfaces of dummy components may not be painted except as
specified in this subpart or in drawings subtended by this subpart.
BILLING CODE 4910-59-P
Appendix--Figures to Subpart W of Part 572
[[Page 69976]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.002
[[Page 69977]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.003
[[Page 69978]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.004
[[Page 69979]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.005
[[Page 69980]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.006
[[Page 69981]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.007
[[Page 69982]]
[GRAPHIC] [TIFF OMITTED] TP21NO13.008
Issued on: November 8, 2013.