Conforming Products List of Evidential Breath Alcohol Measurement Devices, 71480-71483 [07-6040]

Download as PDF 71480 Federal Register / Vol. 72, No. 241 / Monday, December 17, 2007 / Notices automated collection techniques or other forms of information technology. Issued: December 10, 2007. Ann M. Linnertz, Associate Administrator for Administration. [FR Doc. E7–24422 Filed 12–14–07; 8:45 am] BILLING CODE 4910–57–P DEPARTMENT OF TRANSPORTATION National Highway Traffic Safety Administration Reports, Forms, and Record Keeping Requirements Agency Information Collection Activity Under OMB Review National Highway Traffic Safety Administration, DOT. ACTION: Notice. AGENCY: SUMMARY: In compliance with the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.), this notice announces that the Information Collection Request (ICR) abstracted below has been forwarded to the Office of Management and Budget (OMB) for review and comment. The ICR describes the nature of the information collection and the expected burden. The Federal Register Notice with a 60-day comment period was published on April 27, 2007 (72 FR 21068–21069). DATES: Comments must be submitted on or before January 16, 2008. ADDRESSES: Send comments, within 30 days, to the Office of Information and Regulatory Affairs, Office of Management and Budget, 725–17th Street, NW., Washington, DC 20503, Attention: NHTSA Desk Officer. FOR FURTHER INFORMATION CONTACT: Alan Block at the National Highway Traffic Safety Administration, Office of Behavioral Safety Research (NTI–131), 202–366–6401, 1200 New Jersey Avenue, SE., Washington, DC 20590. SUPPLEMENTARY INFORMATION: ebenthall on PROD1PC69 with NOTICES National Highway Traffic Safety Administration Title: 2008 National Survey of Drinking and Driving Attitudes and Behavior. OMB Number: 2127–New. Type of Request: New information collection requirement. Abstract: The National Survey of Drinking and Driving Attitudes and Behavior is conducted on a periodic basis for the National Highway Traffic Safety Administration to obtain a status report on attitudes, knowledge, and selfreported behavior related to alcoholimpaired driving. It is a national telephone survey administered to a VerDate Aug<31>2005 15:28 Dec 14, 2007 Jkt 214001 randomly selected sample of approximately 6,000 persons age 16 and older. Topics covered by the survey include drinking behavior, drinking and driving behavior, avoidance of drinking and driving, use of a designated driver, preventing others from drinking and driving, perceived risks to drinking and driving, perceptions and attitudes about enforcement of drinking and driving laws, knowledge of legal BAC limits, and perceived effectiveness of intervention strategies. The proposed survey is the eighth in the series, which began in 1991. The 2008 survey will repeat many of the questions included in the preceding surveys in order to monitor change over time. The survey will also include new questions that address emergent issues in the area of drinking and driving. The data will be applied to strategic planning to combat the drinking and driving problem, and provide guidance to current programs. Affected Public: Randomly selected members of the general public aged sixteen and older in telephone households. Estimated Total Annual Burden: 2,006 hours (18 pretest interviews averaging 20 minutes per interview, followed by 6,000 interviews averaging 20 minutes per interview administered to the final survey sample). Comments Are Invited on: Whether the proposed collection of information is necessary for the proper performance of the functions of the Department, including whether the information will have practical utility; the accuracy of the Department’s estimate of the burden of the proposed information collection; ways to enhance the quality, utility and clarity of the information to be collected; and ways to minimize the burden of the collection of information on respondents, including the use of automated collection techniques or other forms of information technology. A Comment to OMB is most effective if OMB receives it within 30 days of publication. Authority: 44 U.S.C. 3506(c)(2)(A). Issued on: December 12, 2007. Marilena Amoni, Associate Administrator, Research and Program Development. [FR Doc. E7–24379 Filed 12–14–07; 8:45 am] BILLING CODE 4910–59–P PO 00000 Frm 00136 Fmt 4703 Sfmt 4703 DEPARTMENT OF TRANSPORTATION National Highway Traffic Safety Administration; Highway Safety Programs [Docket No. NHTSA–2007–0028] Conforming Products List of Evidential Breath Alcohol Measurement Devices National Highway Traffic Safety Administration, DOT. ACTION: Notice. AGENCY: SUMMARY: This notice updates the Conforming Products List (CPL) published in the Federal Register on June 29, 2006 (71 FR 37159) for instruments that conform to the Model Specifications for Evidential Breath Testing Devices (58 FR 48705). DATES: Effective Date: December 17, 2007. For technical issues: Ms. De Carlo Ciccel, Behavioral Research Division, NTI–131, National Highway Traffic Safety Administration, 1200 New Jersey Avenue, SE., Washington, DC 20590; Telephone; (202) 366–1694. For legal issues: Ms. Allison Rusnak, Office of Chief Counsel, NCC–113, National Highway Traffic Safety Administration, 1200 New Jersey Avenue, SE., Washington, DC 20590; Telephone: (202) 366–1834. SUPPLEMENTARY INFORMATION: On November 5, 1973, the National Highway Traffic Safety Administration (NHTSA) published the Standards for Devices to Measure Breath Alcohol (38 FR 30459). A Qualified Products List of Evidential Breath Measurement Devices comprised of instruments that met this standard was first issued on November 21, 1974 (39 FR 41399). On December 14, 1984 (49 FR 48854), NHTSA converted this standard to Model Specifications for Evidential Breath Testing Devices (Model Specifications), and published a Conforming Products List (CPL) of instruments that were found to conform to the Model Specifications as Appendix D to that notice (49 FR 48864). On September 17, 1993, NHTSA published a notice to amend the Model Specifications (58 FR 48705) and update the CPL. That notice changed the alcohol concentration levels at which instruments are evaluated, from 0.000, 0.050, 0.101, and 0.151 BAC, to 0.000, 0.020, 0.040, 0.080, and 0.160 BAC. These devices are identified on the CPL with an asterisk. Additionally, that notice includes a test for the presence of acetone and an expanded definition of FOR FURTHER INFORMATION CONTACT: E:\FR\FM\17DEN1.SGM 17DEN1 71481 Federal Register / Vol. 72, No. 241 / Monday, December 17, 2007 / Notices alcohol to include other low molecular weight alcohols; e.g., methyl or isopropyl. Thereafter, NHTSA has periodically updated the CPL with those breath instruments found to conform to the Model Specifications. The most recent update to the CPL was published June 29, 2006 (71 FR 37159). The CPL published today adds 6 instruments that have been evaluated and found to conform to the Model Specifications, as amended on September 17, 1993, for mobile and non-mobile use. In alphabetical order by company, they are: (1) Intoxilyzer 240 (aka: Lion Alcolmeter 400+, outside U.S.) manufactured by CMI, Inc., Owensboro, Kentucky. This is a handheld device intended for use in stationary or roadside operations. It uses a fuel cell sensor and is powered by 5 ‘‘AA’’ batteries. (2) The ‘‘Alcotest 9510’’ manufactured by Draeger Safety, Inc., Durango, Colorado. This is a bench-top device intended for use in a stationary setting. It is AC-powered and has dual sensors. The Alcotest 9510 uses both a fuel cell sensor and a 9-micron infra-red type sensor to measure mouth alcohol. (3) The ‘‘AlcoQuant 6020’’ manufactured by EnviteC by Honeywell GmbH, Fond du Lac, Wisconsin. This is a handheld device intended for use in stationary or roadside operations. It uses a fuel cell sensor and is powered by 4 ‘‘AA’’ batteries. (4) The ‘‘EC–IR–II (Enhanced with serial numbers above 10,000)’’ manufactured by Intoximeters, Inc., St. Louis, Missouri. This is a bench-top, dual sensor device intended for stationary operations, and it is AC powered. This EC–IR–II uses a fuel cell sensor to determine breath alcohol concentration. The device also uses an infra-red type sensor to screen for mouth alcohol. The original EC–IR–II design was modified to incorporate additional test memory capacity, additional hardware to allow recirculation of a wet bath simulator, and enhanced EMC and RFI immunity. This model with the enhancements has an external and internal printer production option available. (5) The ‘‘Phoenix 6.0’’ manufactured by Lifeloc Technologies, Inc., Wheat Ridge, Colorado. This is a handheld device that uses a fuel cell sensor and is powered by an internal battery. It is intended for stationary or roadside operations. The Phoenix 6.0 has the same core electronics, fuel cell, pump, and algorithms as the Lifeloc EV30. Enhancements of the Phoenix 6.0 include high resolution display, wireless printing, barometric pressure sensor (to assist with dry gas calibrations), and Easy ModeTM software to guide the user through the DOT testing protocol. (6) The ‘‘ALC–PRO II (US)’’, manufactured by Tokai-Denshi, Inc., Tokyo, Japan. This device is a handheld battery-powered breath tester with a fuel cell sensor. The breath tester is connected to a 10.5″ by 7.5″ by 5″ AC powered analytical unit. It is intended for stationary or roadside operations. The CPL has been updated to include the six instruments identified above. In accordance with the foregoing, the CPL is therefore updated, as set forth below CONFORMING PRODUCTS LIST OF EVIDENTIAL BREATH MEASUREMENT DEVICES ebenthall on PROD1PC69 with NOTICES Manufacturer and model Mobile Alcohol Countermeasure Systems Corp, Mississauga, Ontario, Canada: Alert J3AD* ........................................................................................................................................................... Alert J4X.ec .......................................................................................................................................................... PBA3000C ............................................................................................................................................................ BAC Systems, Inc., Ontario, Canada: Breath Analysis Computer* ................................................................................................................................... CAMEC Ltd., North Shields, Tyne and Ware, England: IR Breath Analyzer* .............................................................................................................................................. CMI, Inc., Owensboro, Kentucky: Intoxilyzer Model: 200 ................................................................................................................................................................. 200D .............................................................................................................................................................. 240 (aka: Lion Alcolmeter 400+ outside the U.S.) ........................................................................................ 300 ................................................................................................................................................................. 400 ................................................................................................................................................................. 400PA ............................................................................................................................................................ 1400 ............................................................................................................................................................... 4011* ............................................................................................................................................................. 4011A* ........................................................................................................................................................... 4011AS* ......................................................................................................................................................... 4011AS–A* .................................................................................................................................................... 4011AS–AQ* ................................................................................................................................................. 4011 AW* ...................................................................................................................................................... 4011A27–10100* ........................................................................................................................................... 4011A27–10100 with filter* ............................................................................................................................ 5000 ............................................................................................................................................................... 5000 (w/Cal Vapor Re-Circ.) ......................................................................................................................... 5000 (w/3⁄8’’ ID Hose option) ......................................................................................................................... 5000CD ......................................................................................................................................................... 5000CD/FG5 ................................................................................................................................................. 5000EN .......................................................................................................................................................... 5000 (CAL DOJ) ............................................................................................................................................ 5000VA .......................................................................................................................................................... 8000 ............................................................................................................................................................... PAC 1200* ..................................................................................................................................................... S–D2 .............................................................................................................................................................. S–D5 (aka: Lion Alcolmeter SD–5 outside the U.S.) .................................................................................... Draeger Safety, Inc. (aka: National Draeger) Durango, Colorado: VerDate Aug<31>2005 15:28 Dec 14, 2007 Jkt 214001 PO 00000 Frm 00137 Fmt 4703 Sfmt 4703 E:\FR\FM\17DEN1.SGM 17DEN1 Nonmobile X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 71482 Federal Register / Vol. 72, No. 241 / Monday, December 17, 2007 / Notices CONFORMING PRODUCTS LIST OF EVIDENTIAL BREATH MEASUREMENT DEVICES—Continued ebenthall on PROD1PC69 with NOTICES Manufacturer and model Mobile Alcotest Model: 6510 ............................................................................................................................................................... 6810 ............................................................................................................................................................... 7010* ............................................................................................................................................................. 7110* ............................................................................................................................................................. 7110 MKIII ..................................................................................................................................................... 7110 MKIII–C ................................................................................................................................................ 7410 ............................................................................................................................................................... 7410 Plus ...................................................................................................................................................... 9510 ............................................................................................................................................................... Breathalyzer Model: 900 ................................................................................................................................................................. 900A* ............................................................................................................................................................. 900BG* .......................................................................................................................................................... 7410 ............................................................................................................................................................... 7410–II ........................................................................................................................................................... EnviteC by Honeywell GmbH, Fond du Lac, Wisconsin: AlcoQuant 6020 .................................................................................................................................................... Gall’s Inc, Lexington, Kentucky: Alcohol Detection System-A.D.S. 500 .................................................................................................................. Guth Laboratories, Inc., Harrisburg, Pennsylvania: Alcotector BAC–100 ............................................................................................................................................. Alcotector C2H5OH ............................................................................................................................................... Intoximeters, Inc., St. Louis, Missouri: Photo Electric Intoximeter* ................................................................................................................................... GC Intoximeter MK II* ........................................................................................................................................... GC Intoximeter MK IV* ......................................................................................................................................... Auto Intoximeter* .................................................................................................................................................. Intoximeter Model: 3000 ............................................................................................................................................................... 3000 (rev B1)* ............................................................................................................................................... 3000 (rev B2)* ............................................................................................................................................... 3000 (rev B2A)* ............................................................................................................................................. 3000 (rev B2A) w/FM option* ........................................................................................................................ 3000 (Fuel Cell)* ............................................................................................................................................ 3000 D* .......................................................................................................................................................... 3000 DFC* ..................................................................................................................................................... Alcomonitor .................................................................................................................................................... Alcomonitor CC ............................................................................................................................................. Alco-Sensor III ............................................................................................................................................... Alco-Sensor III (Enhanced with Serial Numbers above 1,200,000) ............................................................. Alco-Sensor IV .............................................................................................................................................. Alco-Sensor IV–XL ........................................................................................................................................ Alco-Sensor AZ ............................................................................................................................................. Alco-Sensor FST ........................................................................................................................................... EC/IR ............................................................................................................................................................. EC/IR II .......................................................................................................................................................... EC/IR II (Enhanced with serial number 10,000 or higher) ........................................................................... Portable EC/IR II ........................................................................................................................................... RBT–AZ ......................................................................................................................................................... RBT–III .......................................................................................................................................................... RBT III–A ....................................................................................................................................................... RBT IV ........................................................................................................................................................... RBT IV with CEM (cell enhancement module) ............................................................................................. Komyo Kitagawa, Kogyo, K.K., Japan: Alcolyzer DPA–2* ................................................................................................................................................. Breath Alcohol Meter PAM 101B* ........................................................................................................................ Lifeloc Technologies, Inc., (formerly Lifeloc, Inc.), Wheat Ridge, Colorado: PBA 3000B ........................................................................................................................................................... PBA 3000–P* ........................................................................................................................................................ PBA 3000C ........................................................................................................................................................... Alcohol Data Sensor ............................................................................................................................................. Phoenix ................................................................................................................................................................. Phoenix 6.0 ........................................................................................................................................................... EV 30 .................................................................................................................................................................... FC 10 .................................................................................................................................................................... FC 20 .................................................................................................................................................................... Lion Laboratories, Ltd., Cardiff, Wales, United Kingdom: Alcolmeter Model: 300 ................................................................................................................................................................. 400 ................................................................................................................................................................. 400+ (aka: Intoxilyzer 240 in the U.S.) ......................................................................................................... VerDate Aug<31>2005 15:28 Dec 14, 2007 Jkt 214001 PO 00000 Frm 00138 Fmt 4703 Sfmt 4703 E:\FR\FM\17DEN1.SGM 17DEN1 Nonmobile X X X X X X X X ...................... X X X X X X X X X X X X X X X X X X X X X X X X X X X ...................... X X X X X X X X X X X X X X X ...................... X X X X X X X X X ...................... X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 71483 Federal Register / Vol. 72, No. 241 / Monday, December 17, 2007 / Notices CONFORMING PRODUCTS LIST OF EVIDENTIAL BREATH MEASUREMENT DEVICES—Continued Manufacturer and model Mobile Nonmobile SD–2* ............................................................................................................................................................ SD–5 (aka: S–D5 in the U.S.) ....................................................................................................................... EBA* .............................................................................................................................................................. Intoxilyzer Model: 200 ................................................................................................................................................................. 200D .............................................................................................................................................................. 1400 ............................................................................................................................................................... 5000 CD/FG5 ................................................................................................................................................ 5000 EN ........................................................................................................................................................ Luckey Laboratories, San Bernardino, California: Alco-Analyzer Model: 1000* ............................................................................................................................................................. 2000* ............................................................................................................................................................. National Patent Analytical Systems, Inc., Mansfield, Ohio: BAC DataMaster (with or without the Delta-1 accessory) BAC Verifier DataMaster (w/ or without the Delta-1 accessory) .................................................................. DataMaster cdm (w/ or without the Delta-1 accessory) ............................................................................... DataMaster DMT ........................................................................................................................................... Omicron Systems, Palo Alto, California: Intoxilyzer Model: 4011* ............................................................................................................................................................. 4011AW* ........................................................................................................................................................ Plus 4 Engineering, Minturn, Colorado: 5000 Plus 4* ......................................................................................................................................................... Seres, Paris, France: Alco Master ........................................................................................................................................................... Alcopro .................................................................................................................................................................. Siemans-Allis, Cherry Hill, New Jersey: Alcomat* ................................................................................................................................................................ Alcomat F* ............................................................................................................................................................ Smith and Wesson Electronics, Springfield, Massachusetts: Breathalyzer Model: 900* ............................................................................................................................................................... 900A* ............................................................................................................................................................. 1000* ............................................................................................................................................................. 2000* ............................................................................................................................................................. 2000 (non-Humidity Sensor)* ........................................................................................................................ Sound-Off, Inc., Hudsonville, Michigan: AlcoData ........................................................................................................................................................ Seres Alco Master ......................................................................................................................................... Seres Alcopro ................................................................................................................................................ Stephenson Corp: Breathalyzer 900* .......................................................................................................................................... Tokai-Denshi Inc., Tokyo, Japan: ALC–PRO II (US) .......................................................................................................................................... U.S. Alcohol Testing, Inc./Protection Devices, Inc., Rancho Cucamonga, California: Alco-Analyzer 1000 .............................................................................................................................................. Alco-Analyzer 2000 .............................................................................................................................................. Alco-Analyzer 2100 .............................................................................................................................................. Verax Systems, Inc., Fairport, New York: BAC Verifier* ......................................................................................................................................................... BAC Verifier Datamaster ...................................................................................................................................... BAC Verifier Datamaster II* .................................................................................................................................. X X X X X X X X X X X X X X X X ...................... ...................... X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ...................... ...................... X X X X X X X X X X *Instruments marked with an asterisk (*) meet the Model Specifications detailed in 49 FR 48854 (December 14, 1984) (i.e., instruments tested at 0.000, 0.050, 0.101, and 0.151 BAC.) Instruments not marked with an asterisk meet the Model Specifications detailed in 58 FR 48705 (September 17, 1993), and were tested at BACs = 0.000, 0.020, 0.040, 0.080, and 0.160. All instruments that meet the Model Specifications currently in effect (dated September 17, 1993) also meet the Model Specifications for Screening Devices to Measure Alcohol in Bodily Fluids. ebenthall on PROD1PC69 with NOTICES (Authority: 23 USC 403; 49 CFR 150; 49 CFR Part 501). Marilena Amoni, Associate Administrator for the Office of Research and Program Development. [FR Doc. 07–6040 Filed 12–14–07; 8:45 am] BILLING CODE 4910–59–P DEPARTMENT OF TRANSPORTATION Surface Transportation Board [STB Docket No. AB–364 (Sub-No. 11X)] Mid-Michigan Railroad, Inc.— Abandonment Exemption—In Kent and Montcalm Counties, MI On November 27, 2007, Mid-Michigan Railroad, Inc. (MMRR or petitioner), VerDate Aug<31>2005 19:20 Dec 14, 2007 Jkt 214001 PO 00000 Frm 00139 Fmt 4703 Sfmt 4703 filed with the Surface Transportation Board a petition under 49 U.S.C. 10502 for exemption from the provisions of 49 U.S.C. 10903 to permit the abandonment of a 24.70-mile rail line located between milepost 103.20 in Lowell and milepost 78.50 in Greenville at the end of the line, in Kent and Montcalm Counties, MI. The line traverses U.S. Postal Service Zip Codes 48809, 48838, 48887, and 49331, and E:\FR\FM\17DEN1.SGM 17DEN1

Agencies

[Federal Register Volume 72, Number 241 (Monday, December 17, 2007)]
[Notices]
[Pages 71480-71483]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 07-6040]


-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

National Highway Traffic Safety Administration; Highway Safety 
Programs

[Docket No. NHTSA-2007-0028]


Conforming Products List of Evidential Breath Alcohol Measurement 
Devices

AGENCY: National Highway Traffic Safety Administration, DOT.

ACTION: Notice.

-----------------------------------------------------------------------

SUMMARY: This notice updates the Conforming Products List (CPL) 
published in the Federal Register on June 29, 2006 (71 FR 37159) for 
instruments that conform to the Model Specifications for Evidential 
Breath Testing Devices (58 FR 48705).

DATES: Effective Date: December 17, 2007.

FOR FURTHER INFORMATION CONTACT: For technical issues: Ms. De Carlo 
Ciccel, Behavioral Research Division, NTI-131, National Highway Traffic 
Safety Administration, 1200 New Jersey Avenue, SE., Washington, DC 
20590; Telephone; (202) 366-1694. For legal issues: Ms. Allison Rusnak, 
Office of Chief Counsel, NCC-113, National Highway Traffic Safety 
Administration, 1200 New Jersey Avenue, SE., Washington, DC 20590; 
Telephone: (202) 366-1834.

SUPPLEMENTARY INFORMATION: On November 5, 1973, the National Highway 
Traffic Safety Administration (NHTSA) published the Standards for 
Devices to Measure Breath Alcohol (38 FR 30459). A Qualified Products 
List of Evidential Breath Measurement Devices comprised of instruments 
that met this standard was first issued on November 21, 1974 (39 FR 
41399).
    On December 14, 1984 (49 FR 48854), NHTSA converted this standard 
to Model Specifications for Evidential Breath Testing Devices (Model 
Specifications), and published a Conforming Products List (CPL) of 
instruments that were found to conform to the Model Specifications as 
Appendix D to that notice (49 FR 48864).
    On September 17, 1993, NHTSA published a notice to amend the Model 
Specifications (58 FR 48705) and update the CPL. That notice changed 
the alcohol concentration levels at which instruments are evaluated, 
from 0.000, 0.050, 0.101, and 0.151 BAC, to 0.000, 0.020, 0.040, 0.080, 
and 0.160 BAC. These devices are identified on the CPL with an 
asterisk. Additionally, that notice includes a test for the presence of 
acetone and an expanded definition of

[[Page 71481]]

alcohol to include other low molecular weight alcohols; e.g., methyl or 
isopropyl. Thereafter, NHTSA has periodically updated the CPL with 
those breath instruments found to conform to the Model Specifications. 
The most recent update to the CPL was published June 29, 2006 (71 FR 
37159).
    The CPL published today adds 6 instruments that have been evaluated 
and found to conform to the Model Specifications, as amended on 
September 17, 1993, for mobile and non-mobile use. In alphabetical 
order by company, they are:
    (1) Intoxilyzer 240 (aka: Lion Alcolmeter 400+, outside U.S.) 
manufactured by CMI, Inc., Owensboro, Kentucky. This is a handheld 
device intended for use in stationary or roadside operations. It uses a 
fuel cell sensor and is powered by 5 ``AA'' batteries.
    (2) The ``Alcotest 9510'' manufactured by Draeger Safety, Inc., 
Durango, Colorado. This is a bench-top device intended for use in a 
stationary setting. It is AC-powered and has dual sensors. The Alcotest 
9510 uses both a fuel cell sensor and a 9-micron infra-red type sensor 
to measure mouth alcohol.
    (3) The ``AlcoQuant 6020'' manufactured by EnviteC by Honeywell 
GmbH, Fond du Lac, Wisconsin. This is a handheld device intended for 
use in stationary or roadside operations. It uses a fuel cell sensor 
and is powered by 4 ``AA'' batteries.
    (4) The ``EC-IR-II (Enhanced with serial numbers above 10,000)'' 
manufactured by Intoximeters, Inc., St. Louis, Missouri. This is a 
bench-top, dual sensor device intended for stationary operations, and 
it is AC powered. This EC-IR-II uses a fuel cell sensor to determine 
breath alcohol concentration. The device also uses an infra-red type 
sensor to screen for mouth alcohol. The original EC-IR-II design was 
modified to incorporate additional test memory capacity, additional 
hardware to allow recirculation of a wet bath simulator, and enhanced 
EMC and RFI immunity. This model with the enhancements has an external 
and internal printer production option available.
    (5) The ``Phoenix 6.0'' manufactured by Lifeloc Technologies, Inc., 
Wheat Ridge, Colorado. This is a handheld device that uses a fuel cell 
sensor and is powered by an internal battery. It is intended for 
stationary or roadside operations. The Phoenix 6.0 has the same core 
electronics, fuel cell, pump, and algorithms as the Lifeloc EV30. 
Enhancements of the Phoenix 6.0 include high resolution display, 
wireless printing, barometric pressure sensor (to assist with dry gas 
calibrations), and Easy ModeTM software to guide the user 
through the DOT testing protocol.
    (6) The ``ALC-PRO II (US)'', manufactured by Tokai-Denshi, Inc., 
Tokyo, Japan. This device is a handheld battery-powered breath tester 
with a fuel cell sensor. The breath tester is connected to a 10.5'' by 
7.5'' by 5'' AC powered analytical unit. It is intended for stationary 
or roadside operations.
    The CPL has been updated to include the six instruments identified 
above.
    In accordance with the foregoing, the CPL is therefore updated, as 
set forth below

    Conforming Products List of Evidential Breath Measurement Devices
------------------------------------------------------------------------
         Manufacturer and model               Mobile         Nonmobile
------------------------------------------------------------------------
Alcohol Countermeasure Systems Corp,
 Mississauga, Ontario, Canada:
    Alert J3AD\*\.......................              X               X
    Alert J4X.ec........................              X               X
    PBA3000C............................              X               X
BAC Systems, Inc., Ontario, Canada:
    Breath Analysis Computer\*\.........              X               X
CAMEC Ltd., North Shields, Tyne and
 Ware, England:
    IR Breath Analyzer\*\...............              X               X
CMI, Inc., Owensboro, Kentucky:
    Intoxilyzer Model:
        200.............................              X               X
        200D............................              X               X
        240 (aka: Lion Alcolmeter 400+                X               X
         outside the U.S.)..............
        300.............................              X               X
        400.............................              X               X
        400PA...........................              X               X
        1400............................              X               X
        4011\*\.........................              X               X
        4011A\*\........................              X               X
        4011AS\*\.......................              X               X
        4011AS-A\*\.....................              X               X
        4011AS-AQ\*\....................              X               X
        4011 AW\*\......................              X               X
        4011A27-10100\*\................              X               X
        4011A27-10100 with filter\*\....              X               X
        5000............................              X               X
        5000 (w/Cal Vapor Re-Circ.).....              X               X
        5000 (w/\3/8\'' ID Hose option).              X               X
        5000CD..........................              X               X
        5000CD/FG5......................              X               X
        5000EN..........................              X               X
        5000 (CAL DOJ)..................              X               X
        5000VA..........................              X               X
        8000............................              X               X
        PAC 1200\*\.....................              X               X
        S-D2............................              X               X
        S-D5 (aka: Lion Alcolmeter SD-5               X               X
         outside the U.S.)..............
Draeger Safety, Inc. (aka: National
 Draeger) Durango, Colorado:

[[Page 71482]]

 
    Alcotest Model:
        6510............................              X               X
        6810............................              X               X
        7010\*\.........................              X               X
        7110\*\.........................              X               X
        7110 MKIII......................              X               X
        7110 MKIII-C....................              X               X
        7410............................              X               X
        7410 Plus.......................              X               X
        9510............................  ..............              X
    Breathalyzer Model:
        900.............................              X               X
        900A\*\.........................              X               X
        900BG\*\........................              X               X
        7410............................              X               X
        7410-II.........................              X               X
EnviteC by Honeywell GmbH, Fond du Lac,
 Wisconsin:
    AlcoQuant 6020......................              X               X
Gall's Inc, Lexington, Kentucky:
    Alcohol Detection System-A.D.S. 500.              X               X
Guth Laboratories, Inc., Harrisburg,
 Pennsylvania:
    Alcotector BAC-100..................              X               X
    Alcotector C2H5OH...................              X               X
Intoximeters, Inc., St. Louis, Missouri:
    Photo Electric Intoximeter\*\.......  ..............              X
    GC Intoximeter MK II\*\.............              X               X
    GC Intoximeter MK IV\*\.............              X               X
    Auto Intoximeter\*\.................              X               X
    Intoximeter Model:
        3000............................              X               X
        3000 (rev B1)\*\................              X               X
        3000 (rev B2)\*\................              X               X
        3000 (rev B2A)\*\...............              X               X
        3000 (rev B2A) w/FM option\*\...              X               X
        3000 (Fuel Cell)\*\.............              X               X
        3000 D\*\.......................              X               X
        3000 DFC\*\.....................              X               X
        Alcomonitor.....................  ..............              X
        Alcomonitor CC..................              X               X
        Alco-Sensor III.................              X               X
        Alco-Sensor III (Enhanced with                X               X
         Serial Numbers above 1,200,000)
        Alco-Sensor IV..................              X               X
        Alco-Sensor IV-XL...............              X               X
        Alco-Sensor AZ..................              X               X
        Alco-Sensor FST.................              X               X
        EC/IR...........................              X               X
        EC/IR II........................              X               X
        EC/IR II (Enhanced with serial    ..............              X
         number 10,000 or higher).......
        Portable EC/IR II...............              X               X
        RBT-AZ..........................              X               X
        RBT-III.........................              X               X
        RBT III-A.......................              X               X
        RBT IV..........................              X               X
        RBT IV with CEM (cell                         X               X
         enhancement module)............
Komyo Kitagawa, Kogyo, K.K., Japan:
    Alcolyzer DPA-2\*\..................              X               X
    Breath Alcohol Meter PAM 101B\*\....              X               X
Lifeloc Technologies, Inc., (formerly
 Lifeloc, Inc.), Wheat Ridge, Colorado:
    PBA 3000B...........................              X               X
    PBA 3000-P\*\.......................              X               X
    PBA 3000C...........................              X               X
    Alcohol Data Sensor.................              X               X
    Phoenix.............................              X               X
    Phoenix 6.0.........................              X               X
    EV 30...............................              X               X
    FC 10...............................              X               X
    FC 20...............................              X               X
Lion Laboratories, Ltd., Cardiff, Wales,
 United Kingdom:
    Alcolmeter Model:
        300.............................              X               X
        400.............................              X               X
        400+ (aka: Intoxilyzer 240 in                 X               X
         the U.S.)......................

[[Page 71483]]

 
        SD-2\*\.........................              X               X
        SD-5 (aka: S-D5 in the U.S.)....              X               X
        EBA\*\..........................              X               X
    Intoxilyzer Model:
        200.............................              X               X
        200D............................              X               X
        1400............................              X               X
        5000 CD/FG5.....................              X               X
        5000 EN.........................              X               X
Luckey Laboratories, San Bernardino,
 California:
    Alco-Analyzer Model:
        1000\*\.........................  ..............              X
        2000\*\.........................  ..............              X
National Patent Analytical Systems,
 Inc., Mansfield, Ohio:
    BAC DataMaster (with or without the
     Delta-1 accessory)
        BAC Verifier DataMaster (w/ or                X               X
         without the Delta-1 accessory).
        DataMaster cdm (w/ or without                 X               X
         the Delta-1 accessory).........
        DataMaster DMT..................              X               X
Omicron Systems, Palo Alto, California:
    Intoxilyzer Model:
        4011\*\.........................              X               X
        4011AW\*\.......................              X               X
Plus 4 Engineering, Minturn, Colorado:
    5000 Plus 4\*\......................              X               X
Seres, Paris, France:
    Alco Master.........................              X               X
    Alcopro.............................              X               X
Siemans-Allis, Cherry Hill, New Jersey:
    Alcomat\*\..........................              X               X
    Alcomat F\*\........................              X               X
Smith and Wesson Electronics,
 Springfield, Massachusetts:
    Breathalyzer Model:
        900\*\..........................              X               X
        900A\*\.........................              X               X
        1000\*\.........................              X               X
        2000\*\.........................              X               X
        2000 (non-Humidity Sensor)\*\...              X               X
Sound-Off, Inc., Hudsonville, Michigan:
        AlcoData........................              X               X
        Seres Alco Master...............              X               X
        Seres Alcopro...................              X               X
Stephenson Corp:
        Breathalyzer 900\*\.............              X               X
Tokai-Denshi Inc., Tokyo, Japan:
        ALC-PRO II (US).................              X               X
U.S. Alcohol Testing, Inc./Protection
 Devices, Inc., Rancho Cucamonga,
 California:
    Alco-Analyzer 1000..................  ..............              X
    Alco-Analyzer 2000..................  ..............              X
    Alco-Analyzer 2100..................              X               X
Verax Systems, Inc., Fairport, New York:
    BAC Verifier\*\.....................              X               X
    BAC Verifier Datamaster.............              X               X
    BAC Verifier Datamaster II\*\.......              X               X
------------------------------------------------------------------------
\*\Instruments marked with an asterisk (\*\) meet the Model
  Specifications detailed in 49 FR 48854 (December 14, 1984) (i.e.,
  instruments tested at 0.000, 0.050, 0.101, and 0.151 BAC.) Instruments
  not marked with an asterisk meet the Model Specifications detailed in
  58 FR 48705 (September 17, 1993), and were tested at BACs = 0.000,
  0.020, 0.040, 0.080, and 0.160. All instruments that meet the Model
  Specifications currently in effect (dated September 17, 1993) also
  meet the Model Specifications for Screening Devices to Measure Alcohol
  in Bodily Fluids.

(Authority: 23 USC 403; 49 CFR 150; 49 CFR Part 501).

Marilena Amoni,
Associate Administrator for the Office of Research and Program 
Development.
[FR Doc. 07-6040 Filed 12-14-07; 8:45 am]
BILLING CODE 4910-59-P
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.