(a) Specific requirements
(i) A check valve shall
be placed in the discharge line as near the well bore as possible.
(ii) All blending equipment used in
fracturing operations with flammable and/or combustible fluids shall be
grounded to a conductive rod driven Into the ground and all sand hauling
equipment unloading sand into blender hopper shall be "electrically bonded" to
the blender.
(iii) All supercharged
suction hoses shall be covered with hose covers to deflect fluids when pumping
flammable an /or combustible fluids.
(iv) A pretreatment pressure test on pump
discharge lines shall be made at 1,000 psi over the maximum expected treating
pressure specified by the customer for his well equipment.
(v) All valves in discharge lines shall be
checked to see that they are open before orders are given to pump.
(vi) During operations each employee
designated to handle the pumping shall remain constantly at his designated
position while the pump is in operation, unless relieved by an authorized
employee as directed by the services supervisor on that job.
(vii) All acidizing, fracturing, and hot oil
trucks and tanks shall be at least seventy-five (75) from the well bore.
(A) All special servicing equipment that
could produce a source of ignition shall not be permitted within seventy-five
(75) of any tank containing a flammable and/or combustible material.
(viii) Unauthorized persons shall
remain at least seventy-five (75) from all pumping operations and pressure
testing operations.
(ix) All
flammable and/or combustible fluid spilled on location shall be covered with
dirt before pumping operations start.
(x) The fire truck, when on location, shall
be spotted upwind of the operation when possible.
(xi) Treating pressure shall not exceed
equipment maximum safe working pressure.
(xii) If pumping a flammable and/or
combustible fluid, all electrical or internal combustion equipment, and all
fires, within seventy-five (75) of the well bore, not used for performance of
the job, shall be shut down or off during treatment.
(xiii) Flammable and/or combustible fluids
shall not be bled back into open measuring tanks on equipment designed for
pumping.
(xiv) All spilled oil or
acid shall be covered or properly disposed of after breakout with adequate
precautions taken for personnel to prevent contact with such
material.
Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.