Wyoming Administrative Code
Agency 020 - Environmental Quality, Dept. of
Sub-Agency 0011 - Water Quality
Chapter 27 - UNDERGROUND INJECTION CONTROL PROGRAM CLASS I AND V WELLS
Section 27-8 - Records and Reports

Universal Citation: WY Code of Rules 27-8

Current through September 21, 2024

(a) Monitoring reports required by the permit shall be submitted to the administrator.

(b) Monitoring results shall be reported in the annual reports unless otherwise specified.

(c) The permittee shall submit a written report to the administrator of all remedial work concerning the failure of equipment or operational procedures which resulted in a violation of a permit condition, at the completion of the remedial work.

(d) For any aborted or curtailed operation, in lieu of an annual report, a complete report shall be submitted within thirty (30) days of complete termination of the discharge or associated activity.

(e) Routine periodic reports required by the permit shall be submitted to the administrator within thirty (30) days following the end of the period covered in the report. Reports shall include, if applicable, the following information:

(i) An accounting of the total volume of fluid injected for the period covered by the report, the year to date, and the life of the well to date.

(ii) An analysis of the physical, chemical and other relevant characteristics of the injected fluid.

(iii) A complete description of any event that triggered any alarm or shutdown the well, and the response taken.

(iv) A complete description of any event where maximum annular or injection pressures, as specified in the permit, were exceeded.

(v) The average, maximum and minimum injection pressures for each month.

(vi) Any well workover.

(f) Quarterly and annual reports for hazardous waste wells shall also include a description of any change in the volume of fluid in the casing/tubing annulus of the well, and an explanation of the temperature/volume relationships covering the fluid. Any addition or withdrawal of fluids from the casing/tubing annulus shall be noted.

(g) The results of any mechanical integrity test, or any other testing done on a well, shall be submitted to the administrator within thirty (30) days or with the next quarterly report, whichever comes later, following the completion of the test.

(h) The permittee shall retain all monitoring records required by the permit for a period of three (3) years following facility closure.

Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.