Wyoming Administrative Code
Agency 020 - Environmental Quality, Dept. of
Sub-Agency 0011 - Water Quality
Chapter 25 - SEPTIC TANKS, SOIL ABSORPTION SYSTEMS, AND OTHER SMALL WASTEWATER SYSTEMS
Section 25-12 - Standard Soil Absorption Systems

Universal Citation: WY Code of Rules 25-12

Current through September 21, 2024

(a) General Design Requirements:

(i) All soil absorption systems shall be designed in such a manner that the effluent is effectively filtered and retained below the ground surface. The absorption surface accepts, treats, and disperses wastewater as it percolates through the soil.

(ii) Soil absorption systems shall not be excavated when the soil is wet enough to smear or compact easily. Open soil absorption system excavations shall be protected from surface runoff to prevent the entrance of silt and debris. All smeared or compacted surfaces shall be raked to a depth of one (1) inch, and loose material removed before filter or filler material is placed in the soil absorption system excavation.

(iii) Soil absorption systems shall be designed to approximately follow the ground surface contours so that variation in excavation depths will be minimized. The trenches may be installed at different elevations, but the bottom of each individual trench shall be level throughout its length.

(iv) Shallow soil absorption system depths are encouraged to promote treatment and evapotranspiration. The minimum soil cover depth over the soil absorption system is one (1) foot. The maximum depth to the bottom absorption surface of a soil absorption system is five (5) feet. Finished grading shall prevent ponding and promote surface water runoff.

(v) Pipes, chambers or other products shall be bedded on firm, stable material. Heavy equipment shall not be driven in or over soil absorption systems during construction or backfilling.

(vi) Standard trenches refer to perforated pipe embedded in aggregate-filled trenches that shall conform to the following:
(A) The perforated pipe shall have a minimum diameter of 4 inches. Suitable pipe materials include: ASTM D-2729-11 PVC, ASTM D-3034-08 PVC, Schedule 40 PVC ASTM d1784-11, and ASTM F810-07 PE.

(B) The aggregate shall be crushed rock, gravel or other acceptable, durable and inert material that is free of fines, and has an effective diameter between 1/2 inch and 2- 1/2 inches.

(C) Prior to backfilling, the aggregate shall be covered throughout with a woven/non-woven geotextile material or a three (3) inch layer of straw.

(D) Aggregate shall extend the full width and length of the soil absorption system to a depth of at least twelve (12) inches with at least six (6) inches of drain gravel under the distribution pipe and at least two (2) inches over the distribution pipe.

(E) Maximum width of trench excavation is three (3) feet.

(F) Minimum spacing of trenches (wall to wall) is three (3) feet. Trench spacing shall be increased to nine (9) feet when the area between each trench is considered as reserve area. For clay loam soils that have percolation rates greater than 60 min/in., the nine (9) foot spacing shall also be required but it is not considered as reserve area.

(vii) Standard beds shall conform to the same pipe and aggregate requirements for trenches as found in subparagraphs (vi)(A through D) of this section. Standard beds shall also conform to the following:
(A) The soils shall have percolation rates less than 60 minutes per inch (5-60 mpi). The bottom of the bed must be level, therefore the site shall be relatively flat, sloping no more than one (1) foot from the highest to the lowest point in the installation area.

(B) Distribution laterals within a bed must be spaced on not greater than six (6) feet centers. Sidewalls shall not be more than three (3) feet from a distribution lateral.

(C) Beds must not be wider than twenty-five (25) feet if gravity distribution is used. Multiple beds must be spaced at one-half the bed width.

(D) Rubber tired vehicles must not be driven on the bottom surface of any bed excavation.

(viii) Chambered trenches, when used in lieu of perforated pipe and aggregate, shall be installed in conformance with the manufacturer recommendations. No cracked, weakened, modified, or otherwise damaged chamber units shall be used in any installation.
(A) All chambers shall be an open, arch-shaped structure of durable, non-degradable design, suitable for distribution of effluent without filter material.

(B) All chamber endplates shall be designed so that the bottom elevation of the inlet pipe is at least six (6) inches from the bottom of the chamber.

(C) Inlet and outlet effluent sewer pipes shall enter and exit the chamber endplates. Inspection ports shall be installed at all outlet effluent sewer pipes.

(D) All chambers shall have a splash plate under the inlet pipe or another design feature to avoid unnecessary channeling into the trench bottom.

(E) The maximum width of the bottom absorption surface for a chambered trench is three (3) feet. The excavation to install a chambered trench may exceed three (3) feet.

(F) Minimum spacing of trenches (wall to wall) is three (3) feet. Trench spacing shall be increased to nine (9) feet when the area between each trench is considered as reserve area. For clay loam soils that have percolation rates greater than 60 min/in., the nine (9) foot spacing shall also be required but it is not considered as reserve area.

(ix) Chambered beds shall conform to the same requirements for chambered trenches as found in subparagraphs (viii)(A through D) of this section. Aggregate, as specified in subparagraph (vi)(B) of this section, or native soil shall be used to fill the space between the chambers.

(x) Serial Sidehill Trench:
(A) A minimum of six (6) feet of undisturbed soil shall be maintained between adjacent trench or bed side walls.

(B) The bottom of each serial trench or bed system shall be level.

(C) The overflow pipe between serial soil absorption systems shall be set no higher than the mid-point of the upstream distribution pipe. The overflow pipe shall not be perforated.

(b) A design package for standard soil absorption systems is provided online at the Division's website to assist the applicant in submitting a completed application for coverage under the general permit for small wastewater systems. The worksheet and calculations were prepared by a registered professional engineer employed by the Wyoming Department of Environmental Quality, Water Quality Division. The general design requirements stated in this section are incorporated into the worksheets such that by properly completing the forms and installing the components, the system will comply with these requirements.

Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.