(a) In Class 1, 2AB and 2A waters, radiological limits of 5 pCi/L for combined radium-226 and radium-228, 15 pCi/L for gross alpha particle activity (excluding radon and uranium), 30 µg/L for uranium and 4 millirems per year (mrem/year) for beta particle and photon radioactivity shall not be exceeded.

(b) In Class 2B, 2C, 2D, 3 and 4 waters, the total radium-226 concentration shall not exceed 60 pCi/L.

(c) In all Wyoming surface waters, radioactive materials attributable or influenced by the activities of man shall not be present in the water or in the sediments in amounts which could cause harmful accumulations of radioactivity in plant, wildlife, livestock or aquatic life.

Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.