(a) A spa outlet shall be designed so that the pumping system complies with one of the following:
(i) Two (2) outlets of equal pipe
diameter size designed so that:
(A) Neither
one of the two outlets be cut out of the suction line by a valve; or
(B) By other means which would prevent
entrapment of the bather on the suction orifices.
(ii) One antivortex drain:
(A) The antivortex drain shall not present a
tripping or stubbing hazard to the feet; and
(B) The diameter of the antivortex plate
shall be at least six (6) inches (15cm).
(iii) An open area of one-hundred forty-four
(144) square inches (928 cm²) or larger grate.
(b) All outlet grates, antivortex plates and inlet fittings shall have tamper-proof screws; and
(i) Grates, vortex plates and inlet fittings
shall be in place whenever the spa is in use.
Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.