Wyoming Administrative Code
Agency 010 - Agriculture, Dept. of
Sub-Agency 0008 - Public Swimming Pools
Chapter 4 - SANITARY FACILITIES AND CONTROLS
Section 4-13 - Re-Circulation Systems

Universal Citation: WY Code of Rules 4-13

Current through September 21, 2024

(a) A public pool shall:

(i) Have re-circulation and filtration systems with piping, pumps, filters, disinfection and other equipment to maintain the pool water quality as required by these Regulations.

(b) The system of pumps, filters, disinfection facilities and other equipment shall be of adequate size to re-circulate, filter and disinfect the entire volume of pool water in the following maximum time intervals:

Pool Type

Maximum Turnover Time in Hours

General-Use or Limited-Use pool over 2,000 square feet (185.87m²) of surface area

6

Limited-Use pool less than 2,000 square feet (185.87m²) of surface area

8

Wading and plunge pool

2

Spa

1/2

Flotation tank

A minimum of three (3) turnovers between

users.

Bather load = one (1) person per tank

unit.

; and

(i) Overflow water shall not be less than fifty (50) percent of the total re- circulated water.

(c) A flow meter must be installed in all re-circulation systems and shall:

(i) Measure the flow in gallons per minute;

(ii) Be mounted in accordance with the manufacturer's recommendations; and

(iii) Be easily accessible and easy to read.

(d) Pressure gauges must be installed on the inlet and outlet of the filter.

(e) Spa pool recirculation systems shall be separate from adjacent swimming pools.

Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.