(a) The light intensity shall be:
(i) At least 10 foot
candles (108 lux) at a distance of thirty (30) inches (75 cm) above the floor,
in walk-in refrigeration units and dry food storage areas and in other areas
and rooms during periods of cleaning;
(ii) At least 20 foot candles (215 lux):
(A) At a surface where food is provided for
consumer self-service such as buffets and salad bars or where fresh produce or
packaged foods are sold or offered for consumption;
(B) Inside equipment such as reach-in and
under-counter refrigerators;
(C) At
a distance of thirty (30) inches (75 cm) above the floor in areas used for
handwashing, warewashing, and equipment and utensil storage, and in toilet
rooms; and
(iii) At
least fifty (50) foot candles (540 lux) at a surface where a food employee is
working with food or working with utensils or equipment such as knives,
slicers, grinders, or saws where employee safety is a factor; and
(iv) A minimum of fifty (50) foot candles
(540 lux) of shadow free lighting at the inspection surfaces of the head,
viscera, and carcass.
Disclaimer: These regulations may not be the most recent version. Wyoming may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.