Wisconsin Administrative Code
Public Service Commission
Chapter PSC 116 - Fuel Cost
Section PSC 116.06 - Deferred account balance calculation

Current through August 26, 2024

(1) A deferred account balance debit shall be calculated using the following formula:

If AAFC is [GREATER THAN EQUAL TO] (AAFCF x (1+FCT))

Then DABD = WJR x [AAFC - (AAFCF x (1 + FCT))]

Where DABD = Deferred account balance debit.

WJR = Wisconsin jurisdictional share of the annual native system requirement.

AAFC = Average annual fuel cost.

AAFCF = Forecast of the average annual fuel cost in the approved fuel cost plan.

FCT = Fuel cost tolerance.

(2) A deferred account balance credit shall be calculated using the following formula:

If AAFC is < (AAFCF x (1-FCT))

Then DABC = WJR x [(AAFCF x (1 - FCT)) - AAFC]

Where DABC = Deferred account balance credit.

WJR = Wisconsin jurisdictional share of the annual native system requirement.

AAFC = Average annual fuel cost.

AAFCF = Forecast of the average annual fuel cost in the approved fuel cost plan.

FCT = Fuel cost tolerance.

(3) A utility's fuel cost tolerance shall be set at plus or minus two percent, unless the commission sets a different percentage when approving a fuel cost plan under s. PSC 116.03(3).

Disclaimer: These regulations may not be the most recent version. Wisconsin may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.