(1)Except as otherwise provided in s. NR 664.0001, owners and operators of tanks, surface impoundments or containers that use air emission controls according to subch. CC shall provide all of the following additional information:
(a) Documentation for each floating roof
cover installed on a tank subject to s.
NR 664.1084(4) (a) or
(b) that includes information prepared by the
owner or operator or provided by the cover manufacturer or vendor describing
the cover design, and certification by the owner or operator that the cover
meets the applicable design specifications as listed in s.
NR 664.1084(5) (a) or (6)
(a).
(b) Identification of each container area
subject to subch. CC and certification by the owner or operator that the
requirements of this subchapter are met.
(c) Documentation for each enclosure used to
control air pollutant emissions from tanks or containers according to s.
NR 664.1084(4)
(e) or
664.1086(5) (a) 2.
that includes records for the most recent set of calculations and measurements
performed by the owner or operator to verify that the enclosure meets the
criteria of a permanent total enclosure as specified in "Procedure T-Criteria
for and Verification of a Permanent or Temporary Total Enclosure" under, appendix B.
(d) Documentation for
each floating membrane cover installed on a surface impoundment according to s.
NR 664.1085(3) that includes information
prepared by the owner or operator or provided by the cover manufacturer or
vendor describing the cover design, and certification by the owner or operator
that the cover meets the specifications listed in s.
NR 664.1085(3)
(a).
(e) Documentation for each closed-vent system
and control device installed according to s.
NR 664.1087 that includes design and performance
information as specified in s.
NR 670.024(3) and (4).
(f) An emission monitoring plan for both
Method 21 in, appendix A, incorporated by reference in s.
NR 660.11, and control device monitoring methods. This
plan shall include the following information: monitoring points, monitoring
methods for control devices, monitoring frequency, procedures for documenting
exceedances and procedures for mitigating noncompliances.
(g) When an owner or operator of a facility
subject to subch. CC cannot comply with subch. CC by the date of license
issuance, the schedule of implementation required under s.
NR 665.1082.
Disclaimer: These regulations may not be the most recent version. Wisconsin may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.