Section NR 667.0197 - What are the requirements for ancillary equipment?

Current through August 26, 2024

Provide ancillary equipment with secondary containment (for example, trench, jacketing double-walled piping) that meets the requirements of s. NR 667.0195, except for:

(1) Above ground piping (exclusive of flanges, joints, valves, and other connections) that are visually inspected for leaks on a daily basis.

(2) Welded flanges, welded joints, and welded connections that are visually inspected for leaks on a daily basis.

(3) Seal less or magnetic coupling pumps and seal less valves, that are visually inspected for leaks on a daily basis.

(4) Pressurized above ground piping systems with automatic shut-off devices (for example, excess flow check valves, flow metering shutdown devices, loss of pressure actuated shut-off devices) that are visually inspected for leaks on a daily basis.

Disclaimer: These regulations may not be the most recent version. Wisconsin may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.