Section NR 661.1058 - Standards: pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other connectors

Current through August 26, 2024

(1) Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other connectors shall be monitored within 5 days by the method specified in s. NR 661.1063(2) if evidence of a potential leak is found by visual, audible, olfactory, or any other detection method.

(2) If an instrument reading of 10,000 ppm or greater is measured, a leak is detected.

(3)

(a) When a leak is detected, it shall be repaired as soon as practicable, but not later than 15 calendar days after it is detected, except as provided in s. NR 661.1059.

(b) The first attempt at repair shall be made no later than 5 calendar days after each leak is detected.

(4) First attempts at repair include the best practices described under s. NR 661.1057(5).

(5) Any connector that is inaccessible or is ceramic or ceramic-lined, such as porcelain, glass, or glass-lined, is exempt from the monitoring requirements under sub. (1) and from the recordkeeping requirements specified in s. NR 661.1064.

Disclaimer: These regulations may not be the most recent version. Wisconsin may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.