Wisconsin Administrative Code
Department of Natural Resources
NR 600-699 - Environmental Protection - Hazardous Waste Management
Chapter NR 661 - Hazardous Waste Identification And Listing
Subchapter BB - Air Emission Standards for Equipment Leaks
Section NR 661.1053 - Standards: compressors
Current through August 26, 2024
(1) Each compressor shall be equipped with a seal system that includes a barrier fluid system and that prevents leakage of total organic emissions to the atmosphere, except as provided in subs. (8) and (9).
(2) Each compressor seal system as required under sub. (1) shall meet one of the following conditions:
(3) The barrier fluid may not be a hazardous secondary material with organic concentrations 10 percent or greater by weight.
(4) Each barrier fluid system as described in subs. (1) to (3) shall be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both.
(5)
(6) If the sensor indicates failure of the seal system, the barrier fluid system, or both based on the criterion determined under sub. (5) (b), a leak is detected.
(7)
(8) A compressor is exempt from the requirements under subs. (1) and (2) if it is equipped with a closed-vent system capable of capturing and transporting any leakage from the seal to a control device that complies with the requirements specified in s. NR 661.1060, except as provided in sub. (9).
(9) Any compressor that is designated, as described in s. NR 661.1064(7) (b), for no detectable emissions as indicated by an instrument reading of less than 500 ppm above background is exempt from subs. (1) to (8) if the compressor meets all of the following requirements: