Wisconsin Administrative Code
Department of Natural Resources
NR 400-499 - Environmental Protection - Air Pollution Control
Chapter NR 469 - Emission standards for hazardous air pollutants for halogenated solvent cleaning operations
Section NR 469.08 - Alternative standards
Current through August 26, 2024
(1) As an alternative to meeting the requirements in ss. NR 469.04 to 469.07, each owner or operator of a batch vapor or in-line solvent cleaning machine may elect to comply with the requirements of this section. An owner or operator of a solvent cleaning machine who elects to comply with this section shall comply with the requirements specified in par. (a) or (b).
EL = 330 * (Vol)0.6 (Equation 1)
where:
EL is the 3-month rolling average monthly emission limit (kilograms/month)
Vol is the cleaning capacity of the solvent cleaning machine (cubic meters)
Note: Equation 1 requires the use of metric units. Multiply cubic feet by 0.02832 to obtain cubic meters. Multiply kilograms by 2.2046 to obtain pounds.
(2) Each owner or operator of a batch vapor or in-line solvent cleaning machine complying with sub. (1) shall demonstrate compliance with the applicable 3-month rolling average monthly emission limit on a monthly basis as described in s. NR 469.09(2) and (3).
(3) If the applicable 3-month rolling average emission limit is not met, an exceedance has occurred. All exceedances shall be reported as required in s. NR 469.12(7).
(4) As an alternative to meeting the requirements in ss. NR 469.04 to 469.077, each owner or operator of a continuous web cleaning machine may demonstrate an overall cleaning system control efficiency of 70% or greater using the procedures in s. NR 469.09(7). This demonstration may be made for either a single cleaning machine or for a solvent cleaning system that contains one or more cleaning machines and ancillary equipment, such as storage tanks and distillation units. If the demonstration is made for a cleaning system, the facility shall identify any modifications required to the procedures in s. NR 469.09(7) and they shall be approved by the department.
Table 6. Emission Limits for Batch Vapor and In-line Solvent Cleaning Machines With a Solvent/Air Interface
Solvent Cleaning Machine |
3-Month Rolling Average Monthly Emission Limit kg/m2/month (lb/ft2/month) |
Batch vapor solvent cleaning machines |
150 (30.7) |
Existing in-line solvent cleaning machines |
153 (31.4) |
New in-line solvent cleaning machines |
99 (20.2) |
Table 7. Emission Limits for Cleaning Machines Without a Solvent/Air Interface1,2
Cleaning capacity (cubic meters) |
3-Month rolling average monthly emission limit (kilograms/ month) |
Cleaning capacity (cubic meters) |
3-Month rolling average monthly emission limit (kilograms/ month) |
Cleaning capacity (cubic meters) |
3-Month rolling average monthly emission limit (kilograms/ month) |
0.00 |
0 |
1.00 |
330 |
2.00 |
500 |
0.05 |
55 |
1.05 |
340 |
2.05 |
508 |
0.10 |
83 |
1.10 |
349 |
2.10 |
515 |
0.15 |
106 |
1.15 |
359 |
2.15 |
522 |
0.20 |
126 |
1.20 |
368 |
2.20 |
530 |
0.25 |
144 |
1.25 |
377 |
2.25 |
537 |
0.30 |
160 |
1.30 |
386 |
2.30 |
544 |
0.35 |
176 |
1.35 |
395 |
2.35 |
551 |
0.40 |
190 |
1.40 |
404 |
2.40 |
558 |
0.45 |
204 |
1.45 |
412 |
2.45 |
565 |
0.50 |
218 |
1.50 |
421 |
2.50 |
572 |
0.55 |
231 |
1.55 |
429 |
2.55 |
579 |
0.60 |
243 |
1.60 |
438 |
2.60 |
585 |
0.65 |
255 |
1.65 |
446 |
2.65 |
592 |
0.70 |
266 |
1.70 |
454 |
2.70 |
599 |
0.75 |
278 |
1.75 |
462 |
2.75 |
605 |
0.80 |
289 |
1.80 |
470 |
2.80 |
612 |
0.85 |
299 |
1.85 |
477 |
2.85 |
619 |
0.90 |
310 |
1.90 |
485 |
2.90 |
625 |
0.95 |
320 |
1.95 |
493 |
2.95 |
632 |
1 Divide cubic feet by 35.31 to obtain the cleaning capacity in cubic meters.
2 Multiply kilograms/month by 2.2046 to obtain the 3-month rolling average in pounds/month.