Wisconsin Administrative Code
Department of Natural Resources
NR 400-499 - Environmental Protection - Air Pollution Control
Chapter NR 466 - National emission standards for hazardous air pollutants for printing and flexible substrate surface coating processes
Subchapter I - Printing and Publishing
Section NR 466.10 - Monitoring requirements
Current through August 26, 2024
Following the date on which the initial performance test of a control device is completed, to demonstrate continuing compliance with the standard, the owner or operator shall monitor and inspect each control device required to comply with s. NR 466.06 or 466.07 to ensure proper operation and maintenance by implementing the applicable requirements in this section. Any excursion from the required operating parameters which are monitored in accordance with this section, unless otherwise excused, shall be considered a violation of the emission standard.
(1) Owners or operators of product and packaging rotogravure or wide-web flexographic presses with intermittently-controllable work stations shall implement one of the following procedures for each dryer associated with a work station:
(2) All continuous emission monitors shall comply with performance specifications (PS) 8 or 9 in 40 CFR Part 60, Appendix B, incorporated by reference in s. NR 484.04. The requirements of 40 CFR Part 60, Appendix F, incorporated by reference in s. NR 484.04, shall also be followed. In conducting the quarterly audits required by Appendix F, owners or operators shall challenge the monitors with compounds representative of the gaseous emission stream being controlled.
(3) All temperature monitoring equipment shall be installed, calibrated, maintained and operated according to manufacturer's specifications. The calibration of the chart recorder, data logger or temperature indicator shall be verified every 3 months. The owner or operator shall replace the chart recorder, data logger or temperature indicator if either the owner or operator chooses not to perform the calibration, or the equipment cannot be calibrated properly.
(4) An owner or operator complying with s. NR 466.06 or 466.07 through continuous emission monitoring of a control device shall install, calibrate, operate and maintain continuous emission monitors to measure the total organic volatile matter concentration at both the control device inlet and outlet.
(5) An owner or operator complying with the requirements of s. NR 466.06 or 466.07 through the use of an oxidizer and demonstrating continuous compliance through monitoring of an oxidizer operating parameter shall do the following as appropriate:
(6) An owner or operator, complying with the requirements of s. NR 466.06 or 466.07 through the use of a control device and demonstrating continuous compliance by monitoring an operating parameter to ensure that the capture efficiency measured during the initial compliance test is maintained, shall do all of the following: