(1) FINISHING
MATERIALS. The owner or operator of an affected source subject to the
provisions of s.
NR 465.04(1) (a) or (2) (a) shall
demonstrate initial compliance according to the following procedures as
appropriate:
(a) If complying by using the
methods in s.
NR 465.06(1) (a)
1. or (2) (a) 1., submit the results of the
averaging calculation using Equation 1 in s.
NR 465.06(1) (a)
1. for the first month with the initial
compliance status report required by s.
NR 465.105(2). The first month's
calculation shall include data for the entire month in which the compliance
date falls.
(b) If complying by
using the methods s.
NR 465.06(1) (a)
2. or (2) (a) 2., state in the initial
compliance status report under s.
NR 465.105(2) that compliant stains,
washcoats, sealers, topcoats, basecoats, enamels and thinners, as applicable,
are being used by the affected source.
(c) If complying by using the methods in s.
NR 465.06(1) (a)
2. or (2) (a) 2. and applying coatings using
continuous coaters, do one of the following:
1. State in the initial compliance status
report under s.
NR 465.105(2) that compliant coatings,
as determined by the VHAP content of the coating in the reservoir and the VHAP
content as calculated from records, and compliant thinners are being
used.
2. State in the initial
compliance status report under s.
NR 465.105(2) that compliant coatings,
as determined by the VHAP content of the coating in the reservoir, are being
used; the viscosity of the coating in the reservoir is being monitored; and
compliant thinners are being used. The owner or operator shall also submit data
that demonstrate that viscosity is an appropriate parameter for demonstrating
compliance.
(d) If
complying by using the methods in s.
NR 465.06(1) (a)
3. or (2) (a) 3., do all of the following:
1. Submit a monitoring plan that identifies
each operating parameter to be monitored for the capture device and discusses
why each parameter is appropriate for demonstrating continuous
compliance.
2. Conduct an initial
performance test as required under s.
NR 460.06 using the procedures and test methods listed in
ss.
NR 460.06 and and 465.09(3) (4).
3. Calculate the overall control efficiency
(R) following the procedures in s.
NR 465.09(4).
4. Determine those operating conditions
critical to determining compliance and establish one or more operating
parameters that will ensure compliance with the standard. Operating parameters
shall include the following:
a. For a thermal
incinerator, minimum combustion temperature shall be the operating
parameter.
b. For a catalytic
incinerator equipped with a fixed catalyst bed, the minimum gas temperature
both upstream and downstream of the catalyst bed shall be the operating
parameters.
c. For a catalytic
incinerator equipped with a fluidized catalyst bed, the minimum gas temperature
upstream of the catalyst bed and the pressure drop across the catalyst bed
shall be the operating parameters.
d. For a carbon adsorber, the total
regeneration mass stream flow for each regeneration cycle and the carbon bed
temperature after each regeneration, or the concentration level of organic
compounds exiting the adsorber, shall be the operating parameters, unless the
owner or operator requests and receives approval from the administrator to
establish other operating parameters.
e. For a control device not listed in this
subdivision, one or more operating parameter values shall be established as
follows: The owner or operator shall submit, for the administrator's approval,
a description of the device, test data verifying the performance of the device,
and appropriate site-specific operating parameters that will be monitored to
demonstrate continuous compliance with the standard.
(e) The value for each
site-specific operating parameter in par. (d) 4. shall be calculated as the
arithmetic average of the maximum or minimum operating parameter values, as
appropriate, that demonstrate compliance with the standards, during the 3 test
runs required by s.
NR 465.09(3)
(a).
(2) CONTACT ADHESIVES. The owner or operator
of an affected source subject to the provisions of s.
NR 465.04(1) (b) or (2) (b) shall
demonstrate initial compliance according to the following procedures as
appropriate:
(a) If complying by using the
methods in s.
NR 465.06(1)
(b), (c) 1. or (2) (b) 1., state in the
initial compliance status report under s.
NR 465.105(2) that compliant contact
adhesives are being used by the affected source.
(b) If complying by using the methods in s.
NR 465.06(1) (c)
2. or (2) (b) 2., do all of the following:
1. Submit a monitoring plan that identifies
each operating parameter to be monitored for the capture device and discusses
why each parameter is appropriate for demonstrating continuous
compliance.
2. Conduct an initial
performance test as required under s.
NR 460.06 using the procedures and test methods listed in
ss.
NR 460.06 and and 465.09(3) (4).
3. Calculate the overall control efficiency
(R) following the procedures in s.
NR 465.09(4).
4. Determine those operating conditions
critical to determining compliance and establish one or more operating
parameters that will ensure compliance with the standard. Operating parameters
shall include the following:
a. For a thermal
incinerator, minimum combustion temperature shall be the operating
parameter.
b. For a catalytic
incinerator equipped with a fixed catalyst bed, the minimum gas temperature
both upstream and downstream of the catalyst shall be the operating
parameters.
c. For a catalytic
incinerator equipped with a fluidized catalyst bed, the minimum gas temperature
upstream of the catalyst bed and the pressure drop across the catalyst bed
shall be the operating parameters.
(c) The value for each site-specific
operating parameter in par. (b) 4. shall be calculated as the arithmetic
average of the maximum or minimum operating values, as appropriate, that
demonstrate compliance with the standards, during the 3 test runs required by
s.
NR 465.09(3)
(a).
(3) STRIPPABLE SPRAY BOOTH COATINGS. The
owner or operator of an affected source subject to the provisions s.
NR 465.04(1) (c) or (2) (c) shall
demonstrate initial compliance by stating in the initial compliance status
report under s.
NR 465.105(2) that compliant strippable
spray booth coatings are being used.
(4) WORK PRACTICE STANDARDS. The owner or
operator of an affected source subject to the work practice standards in s.
NR 465.05
shall demonstrate initial compliance by stating in the initial compliance
status report under s.
NR 465.105(2) that the work practice
implementation plan has been developed and procedures have been established for
implementing the provisions of the plan.