(5) HOW DO I DEMONSTRATE INITIAL
COMPLIANCE WITH THE EMISSION LIMITATIONS THAT APPLY TO ME?
(a) You have demonstrated initial compliance
with the emissions limits in s.
NR 463.23(1) (a) if you do the
following, as applicable:
1. For each
electric arc metal melting furnace, electric induction metal melting furnace,
or scrap preheater at an existing iron and steel foundry you demonstrate one of
the following:
a. The average PM
concentration in the exhaust stream, determined according to the performance
test procedures in sub. (3) (a), did not exceed 0.005 gr/dscf.
b. The average total metal HAP concentration
in the exhaust stream, determined according to the performance test procedures
in sub. (3) (b), did not exceed 0.0004 gr/dscf.
2. For each cupola metal melting furnace at
an existing iron and steel foundry you demonstrate one of the following:
a. The average PM concentration in the
exhaust stream, determined according to the performance test procedures in sub.
(3) (a), did not exceed 0.006 gr/dscf.
b. The average total metal HAP concentration
in the exhaust stream, determined according to the performance test procedures
in sub. (3) (b), did not exceed 0.0005 gr/dscf.
3. For each cupola metal melting furnace or
electric arc metal melting furnace at a new iron and steel foundry you
demonstrate one of the following:
a. The
average PM concentration in the exhaust stream, determined according to the
performance test procedures in sub. (3) (a), did not exceed 0.002
gr/dscf.
b. The average total metal
HAP concentration in the exhaust stream, determined according to the
performance test procedures in sub. (3) (b), did not exceed 0.0002
gr/dscf.
4. For each
electric induction metal melting furnace or scrap preheater at a new iron and
steel foundry you demonstrate one of the following:
a. The average PM concentration in the
exhaust stream, determined according to the performance test procedures in sub.
(3) (a), did not exceed 0.001 gr/dscf.
b. The average total metal HAP concentration
in the exhaust stream, determined according to the performance test procedures
in sub. (3) (b), did not exceed 0.00008 gr/dscf.
5. For each pouring station at an existing
iron and steel foundry you demonstrate one of the following:
a. The average PM concentration in the
exhaust stream, measured according to the performance test procedures in sub.
(3) (a), did not exceed 0.010 gr/dscf.
b. The average total metal HAP concentration
in the exhaust stream, determined according to the performance test procedures
in sub. (3) (b), did not exceed 0.0008 gr/dscf.
6. For each pouring area or pouring station
at a new iron and steel foundry you demonstrate one of the following:
a. The average PM concentration in the
exhaust stream, measured according to the performance test procedures in sub.
(3) (a), did not exceed 0.002 gr/dscf.
b. The average total metal HAP concentration
in the exhaust stream, determined according to the performance test procedures
in sub. (3) (b), did not exceed 0.0002 gr/dscf.
7. For each building or structure housing any
emission source at the iron and steel foundry, the opacity of fugitive
emissions discharged to the atmosphere, determined according to the performance
test procedures in sub. (3) (c), did not exceed 20% averaged over 6-minutes,
except for one 6-minute average per hour that did not exceed 27%
opacity.
8. For each cupola metal
melting furnace at a new or existing iron and steel foundry, the average VOHAP
concentration, determined according to the performance test procedures in sub.
(3) (d), did not exceed 20 ppmv corrected to 10% oxygen.
9. For each scrap preheater at an existing
iron and steel foundry that does not meet the work practice standards in s.
NR 463.23(2) (e) 1. or 2., and for each
scrap preheater at a new iron and steel foundry that does not meet the work
practice standard in s.
NR 463.23(2) (f), the average VOHAP
concentration determined according to the performance test procedures in sub.
(3) (d), did not exceed 20 ppmv.
10. For one or more automated conveyor and
pallet cooling lines that use a sand mold system or automated shakeout lines
that use a sand mold system at a new foundry you demonstrate both of the
following:
a. You have reduced the data from
the CEMS to 3-hour averages according to the performance test procedures in
sub. (3) (e).
b. The 3-hour
flow-weighted average VOHAP concentration, measured according to the
performance test procedures in sub. (3) (e), did not exceed 20 ppmv.
11. For each TEA cold box mold or
core making line in a new or existing iron and steel foundry, the average TEA
concentration, determined according to the performance test procedures in sub.
(3) (f) did not exceed 1 ppmv or was reduced by 99%.
(b) You have demonstrated initial compliance
with the operating limits in s.
NR 463.23(1) (b) if you do the
following, as applicable:
1. For each capture
system subject to the operating limit in s.
NR 463.23(1) (b) 1. a., you have
established appropriate site-specific operating limits in your operation and
maintenance plan according to the requirements in s.
NR 463.23(3) (b) and have a record of
the operating parameter data measured during the performance test in accordance
with sub. (4) (a).
2. For each wet
scrubber subject to the operating limits in s.
NR 463.23(1) (b) 2. for pressure drop
and scrubber water flow rate, you have established appropriate site-specific
operating limits and have a record of the pressure drop and scrubber water flow
rate measured during the performance test in accordance with sub. (4)
(b).
3. For each combustion device
subject to the operating limit in s.
NR 463.23(1) (b) 3. for combustion zone
temperature, you have a record of the combustion zone temperature measured
during the performance test in accordance with sub. (3) (d) 4.
4. For each combustion device subject to the
operating limit in s.
NR 463.23(1) (b) 4. for combustion zone
temperature, you have established appropriate site-specific operating limits
and have a record of the combustion zone temperature measured during the
performance test in accordance with sub. (4) (c).
5. For each acid wet scrubber subject to the
operating limits in s.
NR 463.23(1) (b) 5. for scrubbing liquid
flow rate and scrubber blowdown pH, you satisfy both of the following:
a. You have established appropriate
site-specific operating limits for the scrubbing liquid flow rate and have a
record of the scrubbing liquid flow rate measured during the performance test
in accordance with sub. (4) (d).
b.
You have a record of the pH of the scrubbing liquid blowdown measured during
the performance test in accordance with sub. (3) (g) 3.