Current through August 26, 2024
(1) APPLICABILITY AND DESIGNATION OF AFFECTED
FACILITY.
(a) The affected facility to which
the provisions of this section apply is each granular triple superphosphate
storage facility. For the purpose of this section, the affected facility
includes any combination of: storage or curing piles, conveyors, elevators,
screens and mills.
(b) Any facility
under par. (a) that commences construction or modification after October 22,
1974, is subject to the requirements of this section.
(2) DEFINITIONS. As used in this section,
terms not defined in this subsection have the meanings given in s.
NR 440.02.
(a)
"Equivalent P2O5 stored" means the quantity of phosphorus, expressed as
phosphorus pentoxide, being cured or stored in the affected facility.
(b) "Fresh granular triple superphosphate"
means granular triple superphosphate produced within the preceding 72
hours.
(c) "Granular triple
superphosphate storage facility" means any facility curing or storing fresh
granular triple superphosphate.
(d)
"Total fluorides" means elemental fluorine and all fluoride compounds as
measured by reference methods specified in sub. (5), or equivalent or
alternative methods.
(3)
STANDARD FOR FLUORIDES.
(a) On and after the
date on which the performance test required to be conducted by s.
NR 440.08 is
completed, no owner or operator subject to the provisions of this section may
cause to be discharged into the atmosphere from any affected facility any gases
which contain total fluorides in excess of 0.25 g/hr/Mg of equivalent P2O 5
stored (5.0 Ã- 10-4 lb/hr/ton of equivalent P2O5 stored).
(b) No owner or operator subject to the
provisions of this section shall ship fresh granular triple superphospate from
an affected facility.
(4) MONITORING OF OPERATIONS.
(a) The owner or operator of any granular
triple superphosphate storage facility subject to the provisions of this
section shall maintain an accurate account of triple superphosphate in storage
to permit the determination of the amount of equivalent P2O5 stored.
(b) The owner or operator of any granular
triple superphosphate storage facility subject to the provisions of this
section shall maintain a daily record of total equivalent P2O 5 stored by
multiplying the percentage P2O5 content, as determined by sub. (5) (c) 3.,
times the total mass of granular triple superphosphate stored.
(c) The owner or operator of any granular
triple superphosphate storage facility subject to the provisions of this
section shall install, calibrate, maintain and operate a monitoring device
which continuously measures and permanently records the total pressure drop
across any process scrubbing system. The monitoring device shall have an
accuracy of "5% over its operating range.
(d) The owner or operator of any granular
triple superphosphate storage facility subject to the provisions of this
section shall develop for approval by the department a site-specific
methodology including sufficient recordkeeping for the purposes of
demonstrating compliance with sub. (3) (b).
(5) TEST METHODS AND PROCEDURES.
(a) The owner or operator shall conduct
performance tests required in s.
NR 440.08 only
when the following quantities of products are being cured or stored in the
facility.
1. Total granular triple
superphosphate is at least 10% of the building capacity and
2. Fresh granular triple superphosphate is at
least 6% of the total amount of triple superphosphate, or
3. If the provision in subd. 2. exceeds
production capabilities for fresh granular triple superphosphate, fresh
granular triple superphosphate is equal to at least 5 days maximum
production.
(b) In
conducting the performance tests required in s.
NR 440.08, the
owner or operator shall use as reference methods and procedures the test
methods in Appendix A of 40 CFR part 60, incorporated by reference in s.
NR 440.17, or other methods and procedures as specified
in this subsection, except as provided in s.
NR 440.08(2).
(c) The owner or operator shall determine
compliance with the total fluorides standard in sub. (3) as follows:
1. The emission rate (E) of total fluorides
shall be computed for each run using the following equation:
See
PDF for diagram
where:
E is the emission rate of total fluorides, g/Mg (lb/ton)
of equivalent P2O5 stored
Csi is the concentration of total fluorides from emission
point "i", mg/dscm (gr/dscf)
Qsdi is the volumetric flow rate of effluent gas from
emission point "i", dscm/hr (dscf/hr)
N is the number of emission points associated with the
affected facility
P is the equivalent P2O5 stored, Mg/hr (ton/hr)
K is the conversion factor, 1000 mg/g (7000 gr/lb)
2. Method 13A or 13B shall be used
to determine the total fluorides concentration (Csi) and volumetric flow rate
(Qsdi) of the effluent gas from each of the emission points. The sampling shall
be at least 60 minutes and 0.85 dscm (30 dscf).
3. The equivalent P2O5 feed rate (P) shall be
computed for each run using the following equation:
See
PDF for diagram
where:
Mp is the amount of product in storage, Mg (ton)
Rp is the P2O5 content of product in storage, weight
fraction
a. The accountability system
of sub. (4) (a) shall be used to determine the amount of product (Mp) in
storage.
b. The Association of
Official Analytical Chemists (AOAC) Method 9, incorporated by reference in s.
NR 440.17, shall be used to determine the P2O5 content
(Rp) of the product in storage.