(1) APPLICABILITY
AND DESIGNATION OF AFFECTED FACILITY.
(a) The
affected facility to which the provisions of this section apply is each triple
superphosphate plant having a design capacity of more than 15 tons of
equivalent P2O5 feed per calendar day. For the purpose of this section, the
affected facility includes any combination of: mixers, curing belts or dens,
reactors, granulators, dryers, cookers, screens, mills and facilities which
store run-of-pile triple superphosphate.
(b) Any facility under par. (a) that
commences construction or modification after October 22, 1974, is subject to
the requirements of this section.
(2) DEFINITIONS. As used in this section,
terms not defined in this subsection have the meanings given in s.
NR 440.02.
(a)
"Equivalent P2O5 feed" means the quantity of phosphorus, expressed as
phosphorus pentoxide, fed to the process.
(b) "Run-of-pile triple superphosphate" means
any triple superphosphate that has not been processed in a granulator and is
composed of particles at least 25% by weight of which when not caked will pass
through a 16 mesh screen.
(c)
"Total fluorides" means elemental fluorine and all fluoride compounds as
measured by reference methods specified in sub. (5), or equivalent or
alternative methods.
(d) "Triple
superphosphate plant" means any facility manufacturing triple superphosphate by
reacting phosphate rock with phosphoric acid. A run-of-pile triple
superphosphate plant includes curing and storing.
(3) STANDARD FOR FLUORIDES. On and after the
date on which the performance test required to be conducted by s.
NR 440.08 is
completed, no owner or operator subject to the provisions of this section may
cause to be discharged into the atmosphere from any affected facility any gases
which contain total fluorides in excess of 100 g/Mg of equivalent P2O 5 feed
(0.20 lb/ton).
(4) MONITORING OF
OPERATIONS.
(a) The owner or operator of any
triple superphosphate plant subject to the provisions of this section shall
install, calibrate, maintain and operate a flow monitoring device which can be
used to determine the mass flow of phosphorus-bearing feed material to the
process. The flow monitoring device shall have an accuracy of " 5% over its
operating range.
(b) The owner or
operator of any triple superphosphate plant shall maintain a daily record of
equivalent P2O5 feed by first determining the total mass rate in Mg/hr of
phosphorus-bearing feed using a flow monitoring device meeting the requirements
of par. (a) and then by proceeding according to sub. (5) (b) 3.
(c) The owner or operator of any triple
superphosphate plant subject to the provisions of this section shall install,
calibrate, maintain and operate a monitoring device which continuously measures
and permanently records the total pressure drop across the process scrubbing
system. The monitoring device shall have an accuracy of " 5% over its operating
range.
(5) TEST METHODS
AND PROCEDURES.
(a) In conducting the
performance tests required in s.
NR 440.08, the
owner or operator shall use as reference methods and procedures the test
methods in Appendix A of 40 CFR part 60, incorporated by reference in s.
NR 440.17, or other methods and procedures as specified
in this subsection, except as provided in s.
NR 440.08(2).
(b) The owner or operator shall determine
compliance with the total fluorides standard in sub. (3) as follows:
1. The emission rate (E) of total fluorides
shall be computed for each run using the following equation:
See
PDF for diagram
where:
E is the emission rate of total fluorides, g/Mg (lb/ton)
of equivalent P2O5 feed
Csi is the concentration of total fluorides from emission
point "i", mg/dscm (gr/dscf)
Qsdi is the volumetric flow rate of effluent gas from
emission point "i", dscm/hr (dscf/hr)
N is the number of emission points associated with the
affected facility
P is the equivalent P2O5 feed rate, Mghr (ton/hr)
K is the conversion factor, 1000 mg/g (7000 gr/lb)
2. Method 13A or 13B shall be used
to determine the total fluorides concentration (Csi) and volumetric flow rate
(Qsdi) of the effluent gas from each of the emission points. The sampling shall
be at least 60 minutes and 0.85 dscm (30 dscf).
3. The equivalent P2O5 feed rate (P) shall be
computed for each run using the following equation:
See
PDF for diagram
where:
Mp is the total mass flow rate of phosphorus-bearing feed,
Mg/hr (ton/hr)
Rp is the P2O5 content, decimal fraction
a. The accountability system of sub. (4) (a)
shall be used to determine the mass flow rate (Mp) of the phosphorus-bearing
feed.
b. The Association of
Official Analytical Chemists (AOAC) Method 9, incorporated by reference in s.
NR 440.17, shall be used to determine the P2O5 content
(Rp) of the feed.