Wisconsin Administrative Code
Department of Natural Resources
NR 400-499 - Environmental Protection - Air Pollution Control
Chapter NR 440 - Standards of performance for new stationary sources
Subchapter II - Standards of Performance
Section NR 440.21 - Incinerators
Current through August 26, 2024
(1) APPLICABILITY AND DESIGNATION OF AFFECTED FACILITY.
(2) DEFINITIONS. As used in this section, terms not defined in this subsection have the meanings given in s. NR 440.02.
(3) STANDARD FOR PARTICULATE MATTER. On and after the date on which the initial performance test is completed or required to be completed under s. NR 440.08, whichever date comes first, no owner or operator subject to the provisions of this section may cause to be discharged into the atmosphere from any affected facility any gases which contain particulate matter in excess of 0.18 g/dscm (0.08 gr/dscf) corrected to 12% CO2.
(4) MONITORING OF OPERATIONS. The owner or operator of any incinerator subject to the provisions of this section shall record the daily charging rates and hours of operation.
(5) TEST METHODS AND PROCEDURES.
C12 = Cs (12/%CO2)
where:
C12 is the concentration of particulate matter corrected to 12% CO2 g/dscm (gr/dscf)
Cs is the concentration of particulate matter, g/dscm (gr/dscf)
%CO2 is the CO2 concentration, percent dry basis
(%CO2)adj, = (%CO2) di (Qdi/Qdo)
where:
(%CO2)adj is the adjusted outlet CO2 concentration, percent dry basis
(%CO2)di is the CO2 concentration measured before the scrubber, percent dry basis
Qdi is the volumetric flow rate of effluent gas before the wet scrubber, dscm/min (dscf/min)
Qdo is the volumetric flow rate of effluent gas after the wet scrubber, dscm/min (dscf/min)
(%CO2)adj = (%CO2) di [(100 + %EAi)/ (100 + %EAo)]
where:
(%CO2)adj is the adjusted outlet CO2 concentration, percent dry basis
(%CO2)di is the CO2 concentration at the inlet of the wet scrubber, percent dry basis
%EAi is the excess air at the inlet of the scrubber, percent
%EAo is the excess air at the outlet of the scrubber, percent