Wisconsin Administrative Code
Department of Natural Resources
NR 200-299 - Environmental Protection Wisconsin Pollutant Discharge Elimination System
Chapter NR 255 - Battery manufacturing
Subchapter IV - Lead Subcategory
Section NR 255.34 - Pretreatment standards for existing sources
Current through August 26, 2024
(1) Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subchapter that introduces pollutants into a POTW shall comply with 40 CFR Part 403 and achieve the following pretreatment standards for existing sources:
Table 72
Open Formation - Dehydrated
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead |
|
used |
||
Copper |
3.19 |
1.68 |
Lead |
0.71 |
0.34 |
Table 73
Open Formation - Wet
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead used |
|
Copper |
0.100 |
0.053 |
Lead |
0.022 |
0.010 |
Table 74
Plate Soak
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead |
|
used |
||
Copper |
0.039 |
0.021 |
Lead |
0.008 |
0.004 |
Table 75
Battery Wash with Detergent
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead used |
|
Copper |
1.71 |
0.90 |
Lead |
0.38 |
0.18 |
Table 76
Direct Chill Lead Casting
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead used |
|
Copper |
0.0004 |
0.0002 |
Lead |
0.00008 |
0.00004 |
Table 77
Mold Release Formulation
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead used |
|
Copper |
0.011 |
0.006 |
Lead |
0.002 |
0.001 |
Table 78
Truck Wash
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units -mg/kg of lead intrucked batteries English units -lb/million lbs of lead in trucked batteries |
||
Copper |
0.026 |
0.014 |
Lead |
0.005 |
0.002 |
Table 79
Laundry
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead |
|
used |
||
Copper |
0.21 |
0.11 |
Lead |
0.05 |
0.02 |
Table 80
Miscellaneous Wastewater Streams
PSES
POLLUTANT OR POLLUTANT PROPERTY |
MAXIMUM FOR ANY 1 DAY |
MAXIMUM FOR MONTHLY AVERAGE |
Metric units - |
mg/kg of lead used |
|
English units - |
lb/million lbs of lead used |
|
Copper |
0.58 |
0.31 |
Lead |
0.13 |
0.06 |
(2) There may be no discharge allowance for process wastewater pollutants from any battery manufacturing operation other than those battery manufacturing operations listed in tables 72 to 80.
(3) In cases where battery employe shower wastewater containing concentrations of lead exceeding 0.20 mg/l is combined with process wastewaters prior to treatment, the control authority may, under and notwithstanding the provisions of s. NR 211.12, exercise its discretion and classify battery employe shower wastewater as an unregulated rather than a dilute (FD) wastestream, for the purpose of applying the combined wastestream formula. Before the control authority may exercise its discretion to classify such a stream as an unregulated stream, the battery manufacturer must provide engineering, production, and sampling and analysis information sufficient to allow a determination by the control authority on how the stream should be classified.