Wisconsin Administrative Code
Department of Natural Resources
NR 200-299 - Environmental Protection Wisconsin Pollutant Discharge Elimination System
Chapter NR 237 - Pharmaceutical manufacturing
Section NR 237.08 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available
Current through August 26, 2024
(1) EXISTING SOURCE. Except as provided in 40 CFR 125.30 to 125.32, any existing source subject to this chapter shall achieve the effluent limitations set forth in subs. (2), (3) and (4) representing the degree of effluent reduction attainable by the application of BPT.
(2) BIOLOGICAL OXYGEN DEMAND AND CHEMICAL OXYGEN DEMAND.
Table 1
Pharmaceutical Manufacturing
BPT Effluent Limitations |
||
Pollutant or pollutant property |
Variability factor |
Required fractional reduction |
BOD5 |
3.0 |
0.9 |
COD |
2.2 |
0.74 |
(3) TOTAL SUSPENDED SOLIDS. The TSS BPT effluent limitation shall be calculated by multiplying the BOD5 limitation, as calculated in sub. (2), by 1.7.
(4) CYANIDE AND PH. The following limitations for cyanide and pH apply:
Table 2
Pharmaceutical Manufacturing
BPT Effluent Limitations |
||
milligrams per liter |
||
Pollutant or pollutant property |
Maximum for any 1 day |
Average of daily values for 30 consecutive days |
Cyanide (1) |
33.5 |
9.4 |
pH |
(2) |
(2) |