Wisconsin Administrative Code
Department of Natural Resources
NR 100-199 - Environmental Protection General
Chapter NR 140 - Groundwater Quality
Subchapter III - Evaluation and Response Procedures
Section NR 140.20 - Indicator parameter groundwater standards

Universal Citation: WI Admin Code ยง NR 140.20

Current through August 26, 2024

(1) ESTABLISHING BACKGROUND WATER QUALITY. Background water quality at a facility, practice or activity at which monitoring is required shall be established by sampling one or more monitoring points at locations and depths sufficient to yield groundwater samples that are representative of background water quality at or near the facility, practice or activity. Background water quality shall be determined for indicator parameters specified by the department. Background water quality for indicator parameters shall be established by averaging a minimum of 8 sample results from each well. The department may exclude any sample result which is nonrepresentative of background water quality. In making the calculations required in this section, the department may use as many representative sample points as are available.

(2) ESTABLISHING PREVENTIVE ACTION LIMITS FOR INDICATOR PARAMETERS. For each indicator parameter, except total coliform bacteria, for which groundwater monitoring is required by the department, the preventive action limit shall be established based upon a change of water quality with respect to background water quality according to the methodology specified in any of the following:

(a) For field pH, the preventive action limit shall be one pH unit above or below the pH of the background water quality.

(b) For field temperature, the preventive action limit shall be 3 standard deviations or 10ºF (5.6ºC), whichever is greater, above or below the temperature of the background water quality.

(c) For all other indicator parameters, the preventive action limit shall be the background water quality for that parameter plus 3 standard deviations or the background water quality plus the increase of that parameter listed in Table 3, whichever is greater.

Note: The standard deviation for a group of samples is equal to the square root of: the value of the sum of the squares of the difference between each sample in the sample group and the mean for that sample group divided by the number of samples in the sample group where the sample group has 30 or more samples and by one less than the number of samples in the sample group where the sample group has less than 30 samples.

(3) TOTAL COLIFORM BACTERIA INDICATOR PARAMETER. The preventive action limit for total coliform bacteria is 0. If the source of total coliform bacteria is determined to be from a regulated facility, practice, or activity, response actions under s. NR 140.24 may be required.

Table 3

Methodology for Establishing Preventive Action Limit for Indicator Parameters

Parameter

Minimum Increase (mg/ l)

Alkalinity

100

Biochemical oxygen demand

25

(BOD5)

Calcium

25

Chemical oxygen demand (COD)

25

Magnesium

25

Nitrogen series

Organic nitrogen

2

Total nitrogen

5

Potassium

5

Sodium

10

Field specific conductance

200 microSiemens/cm

Total dissolved solids (TDS)

200

Total hardness

100

Total organic carbon (TOC)

1

Total organic halogen (TOX)

0.25

Disclaimer: These regulations may not be the most recent version. Wisconsin may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.