Section 296-878-18020 - Move safely on the outside of buildings

Universal Citation: WA Admin Code 296-878-18020

Current through Register Vol. 24-06, March 15, 2024

You must make sure you travel on the outside of the building only when:

(1) You keep at least one window-cleaner's belt terminal attached at all times;

(2) The anchors are not more than forty-eight inches apart.

Note: Anchors can be up to seventy-two inches apart if:

1.The sill or ledge is continuous;

2.The sill or ledge is at least twelve inches wide;

3.The sill or ledge has a slope less than five degrees;

4.There is at least six inches of window sill in front of the mullions.

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 02-22-027, § 296-878-18020, filed 10/28/02, effective 1/1/03.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.