Washington Administrative Code
Title 296 - Labor and Industries, Department of
Chapter 296-876 - Ladders, portable and fixed
Section 296-876-60075 - Wells

Universal Citation: WA Admin Code 296-876-60075

Current through Register Vol. 24-06, March 15, 2024

(1) You must make sure there is at least twenty-seven inches, but not more than thirty inches, from the centerline of the step or rung to the inside face of the well on the climbing side of the ladder.

(2) You must make sure the inside clear width is at least thirty inches.

(3) You must make sure the well:

(a) Completely encircles the ladder; and

(b) Is free of projections.

(4) You must make sure the bottom of the wall on the access side is at least seven feet, but not more than eight feet, above the point of access to the bottom of the ladder.

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 06-16-020, § 296-876-60075, filed 7/24/06, effective 12/1/06.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.