(1) You must only use eye splice thimbles connected with shackles or cover plates and bolts to join wire suspension ropes together.
(2) You must make sure the load ends of wire suspension ropes are:
(a) Equipped with proper size
thimbles; and
(b) Secured
by eye splicing or an equivalent means.
(3) You must make sure all swaged attachments or spliced eyes on wire suspension rope have been made by either:
(a) The wire rope
manufacturer; or
(b) A
qualified person.
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-054, § 296-874-30018, filed 12/7/04, effective 3/1/05.
Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.