You must make sure toeboards, when used, are:

(1) At least three and one-half inches (9 cm) high from the top edge of the toeboard to the platform;

(2) Securely fastened along the outer edge of the platform;

(3) Installed for enough distance along the platform to protect employees below;

(4) Installed so the gap between the bottom of the toeboard and the platform is one-quarter inch (0.7 cm) or less;

(5) Solid or with openings that are one inch (2.5 cm) or less in the largest dimension;

(6) Able to withstand, without failing, a force of at least fifty pounds (222 n) applied in a downward or horizontal direction anywhere along the toeboard.

EXEMPTION:

On float (ship) scaffolds, an edging of three-quarters by one and one-half inch (2 x 4 cm) wood or the equivalent may be used instead of a toeboard.

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-054, § 296-874-20070, filed 12/7/04, effective 3/1/05.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.