Washington Administrative Code
Title 296 - Labor and Industries, Department of
Chapter 296-874 - Scaffolds
Section 296-874-20022 - Make sure portable, hook-on, and attachable ladders meet these requirements

Universal Citation: WA Admin Code 296-874-20022

Current through Register Vol. 24-06, March 15, 2024

(1) You must position portable, hook-on, and attachable ladders so they do not tip the scaffold.

(2) You must make sure hook-on and attachable ladders meet all of the following:

(a) Specifically designed and used for that type of scaffold;

(b) Have rungs that are:
(i) Uniformly spaced;

(ii) Not more than sixteen and three-quarters inches apart;

(iii) At least eleven and one-half inches (29 cm) long;

(iv) Lined up vertically between rest platforms.

(3) You must position the bottom rung not more than twenty-four inches (61 cm) above the scaffold supporting level.

(4) You must have rest platforms at vertical intervals not greater than twenty-four feet (7.3 m) on supported scaffolds.

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-054, § 296-874-20022, filed 12/7/04, effective 3/1/05.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.