Washington Administrative Code
Title 296 - Labor and Industries, Department of
Chapter 296-874 - Scaffolds
Section 296-874-20020 - Provide safe access to scaffolds

Universal Citation: WA Admin Code 296-874-20020

Current through Register Vol. 24-06, March 15, 2024

(1) You must provide scaffold platforms more than two feet (0.6 m) above or below a point of access with at least one of the following means of access:

(a) Portable, hook-on, or attachable ladder;

(b) Stairway-type ladder;

(c) Ladder stand;

(d) Stair tower (scaffold stairway or tower);

(e) Ramp;

(f) Walkway;

(g) Integral prefabricated scaffold access;

(h) Direct access from another scaffold, structure, personnel hoist, or similar surface.

(2) You must make sure crossbraces are not used as a means of access.

Reference:

For requirements about integral prefabricated scaffold access, go to WAC 296-874-40020.

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-054, § 296-874-20020, filed 12/7/04, effective 3/1/05.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.