Washington Administrative Code
Title 296 - Labor and Industries, Department of
Chapter 296-874 - Scaffolds
Section 296-874-20006 - Maintain structural integrity when intermixing scaffold components

Universal Citation: WA Admin Code 296-874-20006

Current through Register Vol. 24-06, March 15, 2024

(1) You must make sure intermixed scaffold components:

(a) Fit together without force; and

(b) Maintain the scaffold's structural integrity.

(2) You must make sure a qualified person determines that modifying components in order to intermix them will result in a structurally sound scaffold.

(3) You must make sure scaffold components made of different metals are not used together.

EXEMPTION:

Different types of metals may be used together if a competent person determines that galvanic action will not reduce the strength of any component to less than the minimum strength required.

Reference:

The minimum strength requirements are found in the following sections:

1. Suspended scaffolds, WAC 296-874-30002;

2. Supported scaffolds, WAC 296-874-40002.

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-054, § 296-874-20006, filed 12/7/04, effective 3/1/05.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.