Washington Administrative Code
Title 246 - Health, Department of
RADIATION
Chapter 246-236 - Licenses and radiation safety requirements for irradiators
OPERATION OF IRRADIATORS
Section 246-236-063 - Pool water purity

Universal Citation: WA Admin Code 246-236-063

Current through Register Vol. 24-24, December 15, 2024

(1) The pool water purification system must be run sufficiently to maintain the conductivity of the pool water below twenty microsiemens per centimeter under normal circumstances. If pool water conductivity rises above twenty microsiemens per centimeter, the licensee shall take prompt actions to lower the pool water conductivity and shall take corrective actions to prevent future recurrences.

(2) The licensee shall measure the pool water conductivity frequently enough, but no less than weekly, to assure that the conductivity remains below twenty microsiemens per centimeter. Conductivity meters must be calibrated at least annually.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.