Washington Administrative Code
Title 246 - Health, Department of
RADIATION
Chapter 246-236 - Licenses and radiation safety requirements for irradiators
OPERATION OF IRRADIATORS
Section 246-236-055 - Personnel monitoring
Current through Register Vol. 24-24, December 15, 2024
(1) Irradiator operators shall wear a personnel dosimeter while operating a panoramic or beam-type irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter must be capable of detecting high energy photons in the normal and accident dose ranges per WAC 246-221-090(3). Each personnel dosimeter must be assigned to and worn by only one individual. Film badges must be replaced at least monthly and other personnel dosimeters that require replacement must be evaluated at least quarterly or promptly after replacement, whichever is more frequent.
(2) Other individuals who enter the radiation room of a panoramic or beam-type irradiator shall wear a dosimeter, which may be a pocket dosimeter. For groups of visitors, only two people who enter the radiation room are required to wear dosimeters. If pocket dosimeters are used to meet the requirements of this subsection, a check of their response to radiation must be done at least annually. Acceptable dosimeters must read within plus or minus 30 percent of the true radiation dose.