Section 246-359-740 - Drain connector to factory assembled structures (FAS)

Universal Citation: WA Admin Code 246-359-740

Current through Register Vol. 24-18, September 15, 2024

(1) A FAS containing plumbing fixtures must be connected to the drain inlet by a drain connector:

(a)Approved by the department of health;

(b) Consisting of pipe not less than Schedule 40 with appropriate fittings and connectors; and

(c)Not less in size than the FAS outlet.

(2) The fitting connected to the drain inlet must be a directional fitting to discharge the flow into the drain inlet.

(3)A drain connector must be:

(a) Installed and maintained with a grade not less than one-fourth inch per foot;

(b)Gas-tight and no longer than necessary to make the direct connection between the mobile home outlet and drain inlet at the site.

(4)Each drain inlet must be maintained gas-tight when not in use.

Statutory Authority: RCW 70.114A.081. 99-03-065, § 246-359-740, filed 1/18/99, effective 2/18/99.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.