Washington Administrative Code
Title 246 - Health, Department of
FACILITY STANDARDS AND LICENSING
Chapter 246-359 - Temporary worker housing construction standard
Section 246-359-500 - Window construction requirements
Current through Register Vol. 24-18, September 15, 2024
(1) All habitable rooms and spaces must be provided with windows the total area of which must be not less than one-tenth of the floor area.
(2) At least one-half of each required window must be able to open for ventilation purposes.
(3) Every sleeping room must have at least one operable window or door for emergency escape or rescue directly opening to an outside area to provide a clear escape away from the building.
(4) Escape or rescue windows must have:
(5) All operable window openings must be screened with sixteen-mesh material.
Statutory Authority: RCW 70.114A.081. 99-03-065, § 246-359-500, filed 1/18/99, effective 2/18/99.