Chapter 246-359 - Temporary worker housing construction standard
Section 246-359-430 - Floors for concrete masonry units (CMU)

Universal Citation: WA Admin Code 246-359-430

Current through Register Vol. 24-18, September 15, 2024

(1) Floors must be concrete slab on grade and not less than three and one-half inches thick reinforced with "6 x 6 10/10 welded wire mesh (wwm)," and be constructed with not less than four sacks of cement per cubic yard.

(2) When concrete is used as the finished floor it must be sealed or finished according to WAC 246-359-530, interior finishes.

Statutory Authority: RCW 70.114A.081. 99-03-065, § 246-359-430, filed 1/18/99, effective 2/18/99.

Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.