Section 246-358-080 - Carbon monoxide alarms, smoke detectors, and fire extinguishers
Universal Citation: WA Admin Code 246-358-080
Current through Register Vol. 24-18, September 15, 2024
(1) An operator shall provide and maintain working carbon monoxide alarms that are:
(a)Located in each dwelling unit with a
sleeping area; and
(b)Installed in
accordance with the manufacturer's recommendations and in compliance with the
building code, WAC
51-51-0315.
(2) An operator shall provide and maintain working smoke detectors that:
(a)Are located
in each sleeping area;
(b) Are
located on each level of dwelling units with a sleeping area;
(c)Are located in each cooking facility
area;
(d)Emits a signal when the
batteries are low;
(e)Are placed on
the ceiling or wall, but not on the wall above any door; and
(f) Are in compliance with the manufacturer's
recommendations and the building code, WAC
51-51-0314.
(3) An operator shall provide properly working fire extinguishers in dwelling units where occupants sleep if the dwelling unit does not have a second means of emergency egress. Fire extinguishers must be:
(a)A minimum
2A:10BC;
(b)Installed and
maintained according to the manufacturer's instructions;
(c)Installed in accordance with local
ordinances, codes, and regulations when applicable.
Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.