Washington Administrative Code
Title 246 - Health, Department of
FACILITY STANDARDS AND LICENSING
Chapter 246-358 - Temporary worker housing
Section 246-358-077 - Tent requirements and maintenances
Universal Citation: WA Admin Code 246-358-077
Current through Register Vol. 24-18, September 15, 2024
(1) Only cherry harvest camps may use tents as TWH.
(2) Each tent must be constructed to sleep no more than 15 occupants.
(3) Tents must provide protection from the elements, insects, and animals.
(4) Structural stability and floors.
(a) Tents and their supporting framework must
be adequately braced and anchored to prevent weather related collapse. The
operator shall provide documentation of the structural stability to the
department of health, if requested.
(b)
(i)
Floors must be smooth, sloped from a raised center towards the lower outer
edges.
(ii) Floors must be without
breaks or holes to provide a hard, stable walking surface.
(iii) Nonridged flooring supported by grass,
dirt, soil, gravel or other uneven surface is not acceptable.
(iv) Floors that are constructed of wood or
concrete must comply with the building code, chapter 19.27 RCW, and this
chapter.
(c) Floor
systems must be designed to prevent the entrance of snakes, rodents, and other
nuisances.
(5) Flame-retardant treatments.
(a) The sidewalls,
drops, and tops of tents must be composed of flame-resistant material or
treated with a flame retardant in an approved manner.
(b) Floor coverings, which are integral to
the tent, and the bunting must be composed of flame-resistant material or
treated with a flame retardant in an approved manner and in accordance with
Uniform Building Code, Standard 31.1.
(c) All tents must have a permanently affixed
label bearing the following information:
(i)
Identification of tent size and fabric or material type;
(ii) For flame-resistant materials, the
necessary information to determine compliance with this section and National
Fire Protection Association Standard 701, Standard Methods of Fire Tests for
Flame Propagation of Textiles and Films;
(iii) For flame retardant materials, the date
that the tent was last treated with an approved flame retardant;
(iv) The trade name and type of flame
retardant used in the flame-retardant treatment; and
(v) The name of the person and firm that
applied the flame re-tardant.
(6) Means of egress.
(a) Tents must have a primary entrance door.
At least one door must lead to the outside of the tent. The door must not be
obstructed in any manner and must remain free of any material or matter where
its presence would obstruct or render the exit hazardous.
(b) If food-handling facilities are provided
in tents, or the tent occupancy capacity is for 10 or more occupants, a window
allowing egress must be located opposite the door and must have a means to open
the window or provide an easily openable space, for example, a zipper which
opens downward to the floor, must be provided.
(7) Floor area. The operator must:
(a) If food-handling facilities are provided
in the tent, provide an additional 20 square feet of floor space;
(b) Provide at least 50 square feet of floor
space for each occupant in rooms used for sleeping purposes.
(8) Ceiling height.
(a) A ceiling height of at least seven feet
is required in 50 percent of the total floor area.
(b) No portion of the tent measuring less
than six feet from the flooring to the ceiling will be included in any
computation of the floor area.
(9) Windows and ventilation.
(a) The operator shall provide a window area
equal to one-tenth of the total floor area in each habitable room which opens
at least halfway or more directly to the outside for cross-ventilation and has
a minimum of 16-mesh screens on all exterior openings.
(b) The windows must have weather-resistant
flaps, which will cover the window area and a means of fastening the flaps to
provide protection from the elements and allow privacy for the
occupants.
(c) The operator shall
instruct occupants to close windows and other outside openings when external
conditions pose a health and safety risk to occupants.
(10) Electrical and lighting. The operator shall ensure that:
(a) Electricity is supplied
to all tents used as habitable room.
(b) All electrical wiring, fixtures and
electrical equipment must comply with the electrical standards of the
department of labor and industries regulations, chapter 19.28 RCW, and local
ordinances, and be maintained in a safe condition.
(c) Each tent used as habitable room has at
least one ceiling-type light fixture and at least one separate floor-type or
wall-type convenience outlet.
(d)
If cooking is provided in the tent, appropriate wiring and electrical equipment
is provided.
Disclaimer: These regulations may not be the most recent version. Washington may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.