Washington Administrative Code
Title 173 - Ecology, Department of (See also Titles 197, 317, 372, and 508)
Chapter 173-219 - RECLAIMED WATER
Section 173-219-380 - General use-based requirements
Current through Register Vol. 24-06, March 15, 2024
(1) Site evaluation. The lead agency may include reclaimed water permit conditions for additional use area requirements in sensitive or critical areas, or where deemed that additional measures are needed or the lead agency may determine use in a proposed area is infeasible, and not approve it. The generator, responsible person or persons must:
(2) Signage or advisory notification. The generator, distributor, or user must notify the public and employees at the use site of the reclaimed water in all use areas by the posting of advisory signs, distribution of written advisory notices, or both.
(3) Use confined to site. The generator, distributor, and user must confine Class B reclaimed water, including runoff and spray, to the use area in the permit and/or the use agreement.
(4) Restrict operation. The generator, distributor, and user must limit operation of all reclaimed water valves and outlets to authorized personnel. They must control or restrict access to hose bibs on reclaimed water lines.
(5) Labeling and design. The labeling, pipeline separation, and other design requirements of WAC 173-219-360, apply to all uses unless otherwise specified by the lead agency.