A. The provisions of
9VAC5-40-30 (Emission testing)
apply.
B. The following EPA test
methods shall be used to demonstrate compliance with the heatset web
letterpress printing process dryer control device control requirements in
9VAC5-40-8384 B.
1. Reference Method 1 or 1A,
as appropriate, shall be used to select the sampling sites.
2. Reference Method 2, 2A, 2C, or 2D, as
appropriate, shall be used to determine the velocity and volumetric flow rate
of the exhaust stream.
3. Reference
Method 3 or 3A, as appropriate, shall be used to determine the concentration of
O2 and CO2.
4. Reference Method 4 shall be used to
determine moisture content.
5.
Reference Methods 18, 25, or 25A shall be used to determine the VOC
concentration of the dryer exhaust stream entering and exiting the control
device, unless the alternate limit in 9VAC5-40-8384 B 2 is being met, in which
case only the VOC concentration of the dryer exhaust control device outlet
shall be determined.
6. Reference
Method 25A shall be used to determine the dryer exhaust control device inlet
and outlet VOC concentrations when the control device outlet concentration is
less than 50 parts per million volume (ppmv) VOC as carbon.
7. If the control device is an oxidizer, the
combustion chamber temperature or catalyst bed inlet temperature corresponding
to destruction efficiencies that meet the requirements of 9VAC5-40-8384 B shall
be recorded.
C. The VOC
content of as-applied inks, coatings, and cleaning materials shall be
determined using Reference Method 24.
1. The
analysis of as-supplied materials may be performed by the manufacturer or the
supplier. Formulation information from the manufacturer may be used in lieu of
Reference Method 24 analysis unless the board or the owner has reason to
believe that the formulation information provided by the manufacturer is
inaccurate.
2. The owner may use
VOC content information provided by the manufacturer or supplier, such as the
container label, the product data sheet, or the Safety Data Sheet (SDS) to
document the VOC content of the as-supplied material.
3. If cleaning materials are diluted by the
owner prior to use, a calculation that combines the as-supplied VOC content
information provided by the manufacturer or supplier, the VOC content of the
diluent, and the proportions in which they are mixed may be used to make a
determination of VOC content of the as-applied cleaning material in lieu of
Reference Method 24.
4. The owner
shall conduct Reference Method 24 testing of any as-applied cleaning material
used for letterpress printing operations at any time at the board's request.
The owner shall be prepared to sample as-applied fountain solution or cleaning
materials at all times.
D. The VOC composite partial vapor pressure
of cleaning solutions shall be determined using the formula provided in
9VAC5-40-8382 C or by an appropriate test method approved by the board.
1. The determination VOC composite partial
vapor pressure for as-supplied cleaning solutions may be performed by the
manufacturer or the supplier. The determination of as-applied composite vapor
pressure based upon the manufacturer's instructions for dilution may be
performed by the manufacturer or supplier.
2. The owner may use VOC composite partial
vapor pressure information provided by the manufacturer or supplier, such as
the container label, the product data sheet, or the Safety Data Sheet (SDS) to
document the VOC composite partial vapor pressure of the as-supplied or
as-applied cleaning materials.
3.
The following provisions apply to the determination of VOC composite partial
vapor pressure for cleaning materials that are diluted by the owner prior to
use:
a. If the dilution is made according to
the manufacturer's instructions, the VOC composite partial vapor pressure for
the as-applied cleaning material provided by the manufacturer or supplier may
be used.
b. If a dilution is made
and an as-applied VOC composite partial vapor pressure has not been provided by
the manufacturer or supplier, or if the dilution is not made according to the
manufacturer's instructions, then the owner shall determine the VOC composite
partial vapor pressure using the calculation method provided in 9VAC5-40-8382 C
or by an appropriate test method approved by the board.
4. The owner shall conduct testing of any
as-applied cleaning materials used for letterpress printing operations at any
time at the board's request. The owner shall be prepared to sample as-applied
cleaning materials at all times.
Statutory Authority: § 10.1-1308 of the Code of
Virginia; §§ 110, 111, 123, 129, 171, 172, and 182 of the federal
Clean Air Act (40 CFR Parts 51 and 60).