A. The provisions of 9VAC5-40-40(Monitoring) apply.
B. Periodic monitoring of offset lithographic printing operations shall be conducted as follows:
1. The alcohol concentration of offset
lithographic printing process fountain solution shall be monitored with a
hydrometer, equipped with temperature correction or with readings adjusted for
temperature, and recorded at least once per shift or once per batch, whichever
is longer. A standard solution shall be used to calibrate the hydrometer for
the type of alcohol used in the fountain.
2. The temperature of refrigerated fountain
solution shall be measured at the recirculating tank at least once per
operating day.
3. The temperature
of a catalytic or thermal oxidation control device shall be monitored at least
once every 15 minutes while the printing process is operating, and that
temperature shall be recorded by an analog or digital recording device.
a. For a catalytic oxidizer, the dryer
exhaust temperature upstream of the catalyst bed shall be monitored and
recorded.
b. For a thermal
oxidizer, the combustion chamber temperature of the oxidizer shall be monitored
and recorded.
4.
Catalyst bed material in a catalytic oxidation control device shall be
inspected annually for general catalyst condition and any signs of potential
catalyst depletion. Sampling and evaluation of the catalyst bed material shall
be conducted whenever the results of the inspection indicate signs of potential
catalyst depletion or poor catalyst condition based on manufacturer's
recommendations, but not less than once per year.
5. If a heatset web offset lithographic
printing process is interlocked to ensure that the control device is operating
and airflow is present when the printing process is operating, then periodic
monitoring of dryer air flow is not required. If no interlock is present, then
the printing process dryer air flow shall be verified and recorded once per
operating day.
Statutory Authority: § 10.1-1308 of the Code of Virginia; §§ 110, 111, 123, 129, 171, 172, and 182 of the federal Clean Air Act (40 CFR Parts 51 and 60).
Disclaimer: These regulations may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.