Virginia Administrative Code
Title 9 - ENVIRONMENT
Agency 5 - STATE AIR POLLUTION CONTROL BOARD
Chapter 40 - EXISTING STATIONARY SOURCES
Part II - Emission Standards
Article 5 - Emission Standards for Synthesized Pharmaceutical Products ManufacturingOperations (Rule 4-5)
Section 9VAC5-40-450 - Standard for volatile organic compounds
Universal Citation: 9 VA Admin Code 9VAC5-40-450
Current through Register Vol. 41, No. 3, September 23, 2024
A. Reactors, distillation operations, crystallizers, centrifuges and vacuum dryers.
1. No owner or other person shall use or
permit the use of any reactor, distillation operation, crystallizer, centrifuge
or vacuum dryer process unit unless such unit is equipped with a vapor control
system that will remove, destroy or prevent the discharge into the atmosphere
of at least 90% by weight of volatile organic compound emissions.
2. Achievement of the emission standard in
subsection A 1 of this section by use of methods in
9VAC5-40-460 A and E will be
acceptable to the board.
B. Air dryers and production equipment exhaust systems.
1. No owner or other person
shall use or permit the use of any air dryer or production equipment exhaust
system process unit unless such unit is equipped with a vapor control system
that will remove, destroy or prevent the discharge into the atmosphere of at
least 90% by weight of volatile organic compound emissions.
2. Achievement of the emission standard in
subsection B 1 of this section by use of methods in
9VAC5-40-460 B and E will be
acceptable to the board.
C. Filling of storage tanks.
1. No owner or other person shall use or
permit the use of any stationary storage tank of more than 2,000 gallons
capacity for storage of any volatile organic compound unless such tank is
equipped with a vapor control system that will remove, destroy or prevent the
discharge into the atmosphere of at least 90% by weight of volatile organic
compound emissions during the filling of such tank.
2. Achievement of the emission standard in
subsection C 1 of this section by use of the methods in
9VAC5-40-460 C and E will be
acceptable to the board.
3. The
provisions of subsection C of this section shall not be applicable to
facilities using volatile organic compounds with a vapor pressure less than 4.1
pounds per square inch absolute at 68°F.
D. Volatile organic compound storage.
1. No owner or other person shall use or
permit the use of any tank for storage of volatile organic compounds, unless
such tank is equipped with a vapor control system which will remove, destroy or
prevent the discharge into the atmosphere of at least 90% by weight of volatile
organic compound emissions.
2.
Achievement of the emission standard in subsection D 1 of this section by use
of control methods in
9VAC5-40-460 D and E will be
acceptable to the board.
3. The
provisions of subsection D of this section shall not be applicable to
facilities using volatile organic compounds with a vapor pressure less than 1.5
pounds per square inch absolute at 68°F.
Statutory Authority
§§ 10.1-1307 and 10.1-1308 of the Code of Virginia.
Disclaimer: These regulations may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.