Virginia Administrative Code
Title 4 - CONSERVATION AND NATURAL RESOURCES
Agency 25 - DEPARTMENT OF ENERGY
Chapter 40 - SAFETY AND HEALTH REGULATIONS FOR MINERAL MINING
Part XV - Safety and Health Regulations-Underground Only
Article 7 - Electricity
Section 4VAC25-40-3958 - Use of track as electrical power conductor

Universal Citation: 4 VA Admin Code 4VAC25-40-3958

Current through Register Vol. 41, No. 3, September 23, 2024

The following standards shall apply where track is used as a power conductor:

1. Both rails of main line tracks shall be welded or bonded at every joint, and cross bonds shall be installed at intervals of not more than 200 feet. If the rails are paralleled with a feeder circuit of like polarity, such paralleled feeder shall be bonded to the track rails at intervals of not more than 1,000 feet.

2. At least one rail on secondary track haulage roads shall be welded or bonded at every joint, and cross bonds shall be installed at intervals of not more than 200 feet.

3. Track switches on entries shall be well-bonded.

4. Rails shall not be used as power conductors in rooms.

Statutory Authority

§§ 45.1-161.3, 45.1-161.294 and 45.1-161.305 of the Code of Virginia.

Disclaimer: These regulations may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.