Virginia Administrative Code
Title 4 - CONSERVATION AND NATURAL RESOURCES
Agency 25 - DEPARTMENT OF ENERGY
Chapter 40 - SAFETY AND HEALTH REGULATIONS FOR MINERAL MINING
Part XV - Safety and Health Regulations-Underground Only
Article 7 - Electricity
Section 4VAC25-40-3955 - Fire precautions in transportation of mining equipment
Current through Register Vol. 41, No. 3, September 23, 2024
A. Prior to moving or transporting any unit of off-track mining equipment in areas of the active workings where energized trolley wires or trolley feeder wires are present:
B. A record shall be kept of the examinations and shall be made available, upon request, to the director.
C. Off-track mining equipment shall be moved or transported in areas of the active workings where energized trolley wires or trolley feeder wires are present only under the direct supervision of a certified person who shall be physically present at all times during moving or transporting such equipment.
D. The frames of off-track mining equipment being moved or transported in accordance with this section shall be covered on the top and on the trolley wire side with fire-resistant material, where appropriate, as determined by the director.
E. Electrical contact shall be maintained between the mine track and the frames of off-track mining equipment being moved in-track and trolley entries, except that rubber-tired equipment need not be grounded to a transporting vehicle if no metal part of such rubber-tired equipment can come into contact with the transporting vehicle.
F. To avoid accidental contact with power lines, the equipment being transported or trammed shall be insulated or assemblage removed, if necessary, if the clearance to the power lines is six inches or less.
G. Sufficient prior notice shall be given the department so that a mine inspector may travel the route of the move before the actual move is made, if he deems it necessary.
H. A minimum vertical clearance of 12 inches shall be maintained between the farthest projection of the unit of equipment which is being moved and the energized trolley wires or trolley feeder wires at all times during the movement or transportation of such equipment. If the height of the seam of minerals does not permit 12 inches of vertical clearance to be so maintained, the following additional precautions shall be taken:
Statutory Authority
§§ 45.1-161.3, 45.1-161.294 and 45.1-161.305 of the Code of Virginia.