Section 4VAC25-40-5120 - Installation of main fans
Current through Register Vol. 41, No. 3, September 23, 2024
Main fans shall be:
1. Installed on the surface;
2. Powered electrically from a circuit independent of the mine power circuit. Internal combustion engines shall be used only for standby power or where electrical power is not available;
3. Installed in fireproof housing provided with fireproof air ducts;
4. Offset not less than 15 feet from the nearest side of the mine opening and equipped with ample means of pressure relief unless:
5. Installed to permit prompt reversal of airflow; and
6. Attended constantly or provided with automatic devices to give alarm when the fans slow down to stop. Such devices shall be placed so they will be seen or heard by responsible persons.