Virginia Administrative Code
Title 4 - CONSERVATION AND NATURAL RESOURCES
Agency 25 - DEPARTMENT OF ENERGY
Chapter 130 - COAL SURFACE MINING RECLAMATION REGULATIONS
Part 817 - Permanent Program Performance Standards-Underground Mining Activities
Section 4VAC25-130-817.43 - Diversions
Universal Citation: 4 VA Admin Code 25-130-817-43
Current through Register Vol. 41, No. 3, September 23, 2024
(a) General requirements.
(1) With the approval of the
division, any flow from mined areas abandoned before May 3, 1978, and any flow
from undisturbed areas or reclaimed areas, after meeting the criteria of
4VAC25-130-817.46 for siltation structure removal, may be diverted from
disturbed areas by means of temporary or permanent diversions. All diversions
shall be designed to minimize adverse impacts to the hydrologic balance within
the permit and adjacent areas, to prevent material damage outside the permit
area and to assure the safety of the public. Diversions shall not be used to
divert water into underground mines without approval of the division in
accordance with 4VAC25-130-817.41(h).
(2) The diversion and its appurtenant
structures shall be designed, located, constructed, and maintained to-
(i) Be stable;
(ii) Provide protection against flooding and
resultant damage to life and property;
(iii) Prevent, to the extent possible using
the best technology currently available, additional contributions of suspended
solids to streamflow outside the permit area; and
(iv) Comply with all applicable local, State,
and Federal laws and regulations.
(3) Temporary diversions shall be removed
when no longer needed to achieve the purpose for which they were authorized.
The land disturbed by the removal process shall be restored in accordance with
this Part. Before diversions are removed, downstream water treatment facilities
previously protected by the diversion shall be modified or removed, as
necessary to prevent overtopping or failure of the facilities. This requirement
shall not relieve the permittee from maintaining water treatment facilities as
otherwise required. A permanent diversion or a stream channel reclaimed after
the removal of a temporary diversion shall be designed and constructed so as to
restore or approximate the premining characteristics of the original stream
channel including the natural riparian vegetation to promote the recovery and
the enhancement of the aquatic habitat.
(4) Diversions which convey water
continuously or frequently shall be designed by a qualified registered
professional engineer and constructed to ensure stability and compliance with
the standards of this Part and any other criteria set by the
division.
(5) Channel side slopes
shall be no steeper than 1.5h:1v in soil.
(6) Adequate freeboard shall be provided to
prevent overtopping. A minimum of 0.3 feet shall be included, with additional
freeboard provided at curves, transitions, and other critical sections as
required.
(7) When rock rip rap
lining is used, consideration shall be given to rip rap size, bedding, and
filter material. Rock used for rip rap shall be non-degradable, and non-acid
forming such as natural sand and gravel, sandstone or limestone. No clay,
shale, or coal shall be used.
(8)
Sediment and other debris shall be removed and the diversion maintained to
provide the design requirements throughout its operation.
(9) The division may specify other criteria
for diversions to meet the requirements of this section.
(b) Diversion of perennial and intermittent streams.
(1) Diversion of perennial and
intermittent streams within the permit area may be approved by the division
after making the finding relating to stream buffer zones called for in
4VAC25-130-817.57 that the diversions will not adversely affect the water
quantity and quality and related environmental resources of the
stream.
(2) The design capacity of
channels for temporary and permanent stream channel diversions shall be at
least equal to the capacity of the unmodified stream channel immediately
upstream and downstream from the diversion.
(3) The requirements of Paragraph (a)(2)(ii)
of this section shall be met when the temporary and permanent diversions for
perennial and intermittent streams are designed so that the combination of
channel, bank and flood-plain configuration is adequate to pass safely the peak
runoff of a 10-year, 6-hour precipitation event for a temporary diversion and a
100-year, 6-hour precipitation event for a permanent diversion.
(4) The design and construction of all stream
channel diversions of perennial and intermittent streams shall be certified by
a qualified registered professional engineer as meeting the standards of this
Part and any other criteria set by the division.
(5) Channels which are constructed in
backfilled material shall be formed during the backfilling and grading of the
area. Unless the backfill material is of sufficiently low permeability, the
channel shall be lined to prevent saturation of the backfill, loss of stream
flow, or degradation of groundwater quality.
(6) Rock rip rap lining shall be placed in
the channels of all diversions of perennial and intermittent streams to the
normal flow depth, including adequate freeboard. Channels constructed in
competent bedrock need not be rip rap lined.
(c) Diversion of miscellaneous flows.
(1) Miscellaneous flows, which consist of all
flows except for perennial and intermittent streams, may be diverted away from
disturbed areas if required or approved by the division. Miscellaneous flows
shall include ground-water discharges and ephemeral streams.
(2) The design, location, construction,
maintenance, and removal of diversions of miscellaneous flows shall meet all of
the performance standards set forth in Paragraph (a) of this section.
(3) The requirements of Paragraph (a)(2)(ii)
of this section shall be met when the temporary and permanent diversions for
miscellaneous flows are designed to pass safely the peak runoff of a 2-year,
6-hour precipitation event for a temporary diversion and a 10-year, 6-hour
precipitation event for a permanent diversion.
(d) Steep slope water conveyances.
(1) A steep slope conveyance, including but
not limited to a rock rip rap flume, concrete flume, or a pipe, shall be used
to convey water down steep slopes to stable natural or constructed drainways.
Steep slope conveyances shall be constructed at locations where concentrated
flows may cause erosion.
(2) The
capacity of the conveyance shall be equal to or greater than the capacity of
the inlet ditch or drainage structure associated with it.
Statutory Authority
§§ 45.1-161.3 and 45.1-230 of the Code of Virginia.
Disclaimer: These regulations may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.