Virginia Administrative Code
Title 2 - AGRICULTURE
Agency 5 - DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES
Chapter 585 - RETAIL FOOD ESTABLISHMENT REGULATIONS
Part IV - Equipment, Utensils, and Linens
Article 5 - Maintenance and Operation
Section 2VAC5-585-1700 - Manual and mechanical warewashing equipment, chemical sanitization - temperature, pH, concentration, and hardness

Universal Citation: 2 VA Admin Code 2VAC5-585-1700

Current through Register Vol. 41, No. 3, September 23, 2024

A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subdivision 3 of 2VAC5-585-1900 shall meet the criteria specified under 2VAC5-585-3380, shall be used in accordance with the EPA-registered label use instructions,P and shall be used as follows:

1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart;P

Minimum Concentration

Minimum Temperature

mg/L (ppm)

pH 10 or less°F (°C)

pH 8.0 or less°F (°C)

25-49

120 (49)

120 (49)

50-99

100 (38)

75 (24)

100

55 (13)

55 (13)

2. An iodine solution shall have a:

a. Minimum temperature of 68°F (20°C);P

b. pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective;P and

c. Concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm);P

3. A quaternary ammonium compound solution shall:

a. Have a minimum temperature of 75°F (24°C);P

b. Have a concentration as specified under 2VAC5-585-3380 and as indicated by the manufacturer's use directions included in the labeling;P and

c. Be used only in water with 500 mg/L (ppm) hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions;P

4. If another solution of a chemical specified under subdivisions 1 through 3 of this section is used, the operator shall demonstrate to the department that the solution achieves sanitization and the use of the solution shall be approved;P or

5. If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions;P and

6. If a chemical sanitizer is generated by a device located on site at the food establishment, it shall be used as specified in subdivisions 1 through 4 of this section and shall be produced by a device that:

a. Complies with regulation as specified in §§ 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and Rodenticide Act (7 USC § 136(q)(1) and 7 USC § 136j);P

b. Complies with 40 CFR 152.500 and 40 CFR 156.10;P

c. Displays the EPA device manufacturing facility registration number on the device;Pf and

d. Is operated and maintained in accordance with manufacturer's instructions.Pf

Statutory Authority: § 3.2-5121 of the Code of Virginia.

Disclaimer: These regulations may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.